Objective. To describe demographic data, clinical outcome and short-term survival after
We used an inverted
Objective. To compare regional body composition, bone mineral density (BMD), and clinical outcome in patients with two different
This clinical study analyzes the long-term outcomes and potential complications of the Grammont's reverse prosthesis in case of trauma in elderly population. Between January 1993 and May 2010, thirty-seven consecutive patients with 26 three- and four-part fractures and 11 fracture-dislocations, mean age 75 (58 to 92) were evaluated with a mean follow-up of 7.3 years. Eight complications occurred: 2 complex sympathetic dystrophies, 3 dislocations, 2 deep infections and one aseptic loosening of the base-plate leading to 3 re-operations and 2 prosthesis revisions. The mean Constant's score dropped from 55 at two year follow-up to 52 (20 to 84) at last revision because of an augmentation of the pain and a diminution of the strength which represented 67% of the mean score for the injured side. Mean modified Constant's score was 68. Only 58% were satisfied or very satisfied because of poor internal and external rotations avoiding nourishment with utensils, dressing and personal hygiene when the dominant side was involved. Two complete glenoid borders, fourteen stable inferior spurs, twenty-one inferior scapular notches including ten of them with medial proximal humeral bone loss or radio lucent lines between the bone and the cement were observed. Notches were more important in size when the follow-up was longer. 62% of the patients had worrying images. The crossing of the clinical and radiological data showed a degradation of the mean Constant's score (41) for pain and strength in cases of notches with troubling proximal humeral images. In spite of only one case of aseptic loosening at 12 year follow-up, results are disappointing and complications and revisions rates important. The functional result is never equal to the pre-broken state. New developments in design, bearing surfaces and surgical technique and a more long term results will refine the role of the reverse concept for fracture.
Aims. There is no consensus on the treatment of proximal humeral fractures. Hemiarthroplasty has been widely used in patients when non-surgical treatment is not possible. There is, despite extensive use, limited information about the long-term outcome. Our primary aim was to report ten-year patient-reported outcome after hemiarthroplasty for acute proximal humeral fractures. The secondary aims were to report the cumulative revision rate and risk factors for an inferior patient-reported outcome. Methods. We obtained data on 1,371 hemiarthroplasties for acute proximal humeral fractures from the Danish
Objectives. The PROximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial has recently demonstrated that surgery is non-superior to non-operative treatment in the management of displaced proximal humeral fractures. The objective of this study was to assess current surgical practice in the context of the PROFHER trial in terms of patient demographics, injury characteristics and the nature of the surgical treatment. Methods. A total of ten consecutive patients undergoing surgery for the treatment of a proximal humeral fracture from each of 11 United Kingdom hospitals were retrospectively identified over a 15 month period between January 2014 and March 2015. Data gathered for the 110 patients included patient demographics, injury characteristics, mode of surgical fixation, the grade of operating surgeon and the cost of the surgical implants. Results. A majority of the patients were female (66%, 73 of 110). The mean patient age was 62 years (range 18 to 89). A majority of patients met the inclusion criteria for the PROFHER trial (75%, 83 of 110). Plate fixation was the most common mode of surgery (68%, 75 patients), followed by intramedullary fixation (12%, 13 patients), reverse
Over the last decade stemless
Proximal humeral fractures (PHFs) are common. There is increasing evidence that most of these fractures should be treated conservatively. However, recent studies have shown an increase in use of operative treatment. The aim of this study was to identify the trends in the incidence and methods of treatment of PHFs in Finland. The study included all Finnish inhabitants aged ≥ 16 years between 1997 and 2019. All records, including diagnostic codes for PHFs and all surgical procedure codes for these fractures, were identified from two national registers. Data exclusion criteria were implemented in order to identify only acute PHFs, and the operations performed to treat them.Aims
Methods
Introduction. Reverse
It is imperative to understand the risks of operating on urgent cases during the COVID-19 (SARS-Cov-2 virus) pandemic for clinical decision-making and medical resource planning. The primary aim was to determine the mortality risk and associated variables when operating on urgent cases during the COVID-19 pandemic. The secondary objective was to assess differences in the outcome of patients treated between sites treating COVID-19 and a separate surgical site. The primary outcome measure was 30-day mortality. Secondary measures included complications of surgery, COVID-19 infection, and length of stay. Multiple variables were assessed for their contribution to the 30-day mortality. In total, 433 patients were included with a mean age of 65 years; 45% were male, and 90% were Caucasian.Aims
Methods
Introduction. Massive rotator cuff tears in the patient who is too young for a reverse
The aims of this study were to investigate the mortality following a proximal humeral fracture. Data from a large population-based fracture register were used to quantify 30-day, 90-day, and one-year mortality rates after a proximal humeral fracture. Associations between the risk of mortality and the type of fracture and its treatment were assessed, and mortality rates were compared between patients who sustained a fracture and the general population. All patients with a proximal humeral fracture recorded in the Swedish Fracture Register between 2011 and 2017 were included in the study. Those who died during follow-up were identified via linkage with the Swedish Tax Agency population register. Age- and sex-adjusted controls were retrieved from Statistics Sweden and standardized mortality ratios (SMRs) were calculated.Aims
Methods
Purpose. to analyze the survivorship of the RSA with a minimum 10 years follow up. Patients and Methods. Between 1992 and 1999, 145 Delta (DePuy) RSAs have been implanted in 138 patients. It was a mulicentric study. Initial etiologies were gathered as following: group A (92 cases) Cuff tear arthropaties (CTA), osteoarthritis (OA) with at least 2 involved cuff tendons, and massive cuff tear with pseudoparalysis (MCT); group B (39 cases) -failed hemiarthroplasties (HA), failed total shoulder arthroplasties (TSA), and fracture sequelae; and group C (14 cases) rheumatoid arthritis, fractures, tumor, and instability. Survival curves were established with the Kaplan-Meier technique. Two end-points were retained: -implant revision, defined by glenoid or humeral replacement or removal, or conversion to HA; - a poor clinical outcome defined by an absolute Constant score of less than 30. Results. At the time of review, 47 patients had died with their prosthesis in place and 30 were lost to follow-up. There were 12 revisions, 6 for infections, 3 for glenoid loosening, 1 for dislocation, 1 for glenoid dissociation (by unscrewing), and 1 for humeral loosening. The survival curve to prosthetic removal showed an overall survivorship of 92% at 10 years. Segmentation according to etiology showed a 97% survivorship for group A and 88% for group B This difference was not significant. No patients of group C had a minimum follow up of ten years because there were died or lost to follow up. The survival curve to a Constant score of less than 30 showed an overall survivorship of 90% at 10 years. Segmentation according to etiology showed a significant difference at 10 years in favor of group A (92%) compared to group B (86%) with a break of the curve after 9 years for group B. Discussion. Our results show that the overall survivorship of the reverse shoulder prosthesis to removal is good even 10 years after implantation, in particular if it had been implanted for CTA, OA, or MCT. However, functional results did deteriorate progressively after 9 years in particular if it had been implanted for revision (HA or TSA). Therefore, extreme caution must be observed in relation to the indications for reverse
Introduction. Insufficient arthroscopic cuff tear reconstruction leading to massive osteoarthritis and irreparable rotator cuff tears might be salvaged by implantation of an inverted total shoulder prosthesis Delta in the elderly. However, despite the generally high success rate and satisfying clinical results of inverted total shoulder arthroplasty, this treatment option has potential complications. Therefore, the objective of this study was a prospective evaluation of the clinical and radiological outcome after a minimum of 2 years follow-up of patients undergoing inverted
We evaluated the results of Cementless Surface Replacement Arthroplasty (CSRA) of the shoulder in 67 patients with advanced glenohumeral destruction who have an intact rotator cuff. Between november 2002 and december 2008, 70 CSRA (32 Copeland/ Biomet and 38 SMRR/ Lima) were implanted in 67 patients. A deltopectoral approach was used in 34 cases and an anterosuperior approach in 36 cases. Patients were assessed using Constant score, a patient satisfaction score and a detailed radiographic analysis. The mean follow up was 3.4 years (range 1 to 7.5 years). The mean Constant score improved preoperatively from 17.6 points (range 2–55) to an average postoperative score of 66.1 (range 13–91). The pain score improved from 1.13 points (range 0–6) to 12.3 points (range 3–15). The forward flexion and external rotation improved from 71° (range 20 to 140) and 0° (range −40 to +45) to 143° (range 60 to180) and 34.4° (range −20 to +60) respectively. Complications included: 1 subscapularis detachment, 5 secondary rotator cuff tear, 1sepsis, 3 patients with shoulder stiffness. No shift in implant position was observed. 11 humeral components developed radiolucencies at the prosthesis-bone interface. The radiographic analysis involved a system of dividing the prosthesis/bone interface into 5 zones. The best clinical results were significantly achieved in patients with necrosis compared with osteoarthritis (Constant Score, ant. elevation, ext. Rotation). Using regression analysis we found that changes in the head-shaft angle position of the implant (valgus/varus placement of the CSRA) significantly predicted the age and sex adjusted Constant score. When the inclination angle of the humeral head decreases, the adjusted Constant score increases. In the same model, we also found that the lateral offset of the humerus significantly predicted the adjusted Constant score. When the lateral offset of the humerus decreases, the adjusted Constant score increases. The medialization of the glenoid significantly and negatively predicted the Constant score. Conclusion. CSRA of the shoulder outcomes have been comparable with those of stemmed arthroplasties. Radiolucent lines occur with follow up and most of the time located in the S1 area. Glenoid wear and humeral head lateralization negatively impact the clinical score. Cementless Shoulder resurfacing is a viable alternative to conventional
Gunshot injuries to the shoulder are rare and
difficult to manage. We present a case series of seven patients
who sustained a severe shoulder injury to the non-dominant side
as a result of a self-inflicted gunshot wound. We describe the injury
as ‘suicide shoulder’ caused by upward and outward movement of the
gun barrel as the trigger is pulled. All patients were male, with
a mean age of 32 years (21 to 48). All were treated at the time
of injury with initial repeated debridement, and within four weeks
either by hemiarthroplasty (four patients) or arthrodesis (three patients).
The hemiarthroplasty failed in one patient after 20 years due to
infection and an arthrodesis was attempted, which also failed due
to infection. Overall follow-up was for a mean of 26 months (12
to 44). All four hemiarthroplasty implants were removed with no
feasible reconstruction ultimately possible, resulting in a poor functional
outcome and no return to work. In contrast, all three primary arthrodeses
eventually united, with two patients requiring revision plating
and grafting. These patients returned to work with a good functional
outcome. We recommend arthrodesis rather than replacement as the
treatment of choice for this challenging injury. Cite this article:
Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) ( This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.