Advertisement for orthosearch.org.uk
Results 1 - 20 of 205
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 137 - 142
1 Mar 2024
van Veghel MHW van der Koelen RE Hannink G Schreurs BW Rijnen WHC

Aims. The aim of this study was to report the long-term follow-up of cemented short Exeter femoral components when used in primary total hip arthroplasty (THA). Methods. We included all primary 394 THAs with a cemented short Exeter femoral component (≤ 125 mm) used in our tertiary referral centre between October 1993 and December 2021. A total of 83 patients (21%) were male. The median age of the patients at the time of surgery was 42 years (interquartile range (IQR) 30 to 55). The main indication for THA was a childhood hip disease (202; 51%). The median follow-up was 6.7 years (IQR 3.1 to 11.0). Kaplan-Meier survival analyses were performed to determine the rates of survival with femoral revision for any indication, for septic loosening, for fracture of the femoral component and for aseptic loosening as endpoints. The indications for revision were evaluated. Fractures of the femoral component were described in detail. Results. The 20-year rate of survival was 85.4% (95% confidence interval (CI) 73.9 to 92.0) with revision for any indication, 96.2% (95% CI 90.5 to 98.5) with revision for septic loosening and 92.7% (95% CI 78.5 to 97.6) with revision for fracture of the femoral component. No femoral components were revised for aseptic loosening. There were 21 revisions of the femoral component; most (seven) as part of a two-stage management of infection. Fracture of the femoral component occurred in four THAs (1.0%) at 6.6, 11.6, 16.5, and 18.2 years of follow-up, respectively. Three of these were transverse fractures and occurred at the level of the lesser trochanter. In one THA, there was a fracture of the neck of the component. Conclusion. THAs using cemented short Exeter femoral components showed acceptable rates of survival of the femoral component at long-term follow-up, in this young cohort of patients. Although fracture is a rare complication of these components, surgeons should be aware of their incidence and possible risk factors. Cite this article: Bone Joint J 2024;106-B(3 Supple A):137–142


Bone & Joint Open
Vol. 3, Issue 6 | Pages 470 - 474
7 Jun 2022
Baek J Lee SC Ryu S Kim J Nam CH

Aims. The purpose of this study was to compare the clinical outcomes, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with or without hepatitis B virus (HBV) infection over at least ten years of follow-up. Methods. From January 2008 to December 2010, 266 TKAs were performed in 169 patients with HBV (HBV group). A total of 169 propensity score–matched patients without HBV were chosen for the control group in a one-to-one ratio. Then, the clinical outcomes, mortalities, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 11.7 years (10.5 to 13.4) in the HBV group and 11.8 years (11.5 to 12.4) in the control group. Results. The mean Knee Society scores in the HBV and control groups improved from 37.1 (SD 5.6) and 38.4 (SD 5.4) points preoperatively to 78.1 (SD 10.8) and 81.7 (SD 10.2) points at final follow-up (p = 0.314), while the mean function scores in the HBV and control groups improved from 36.2 and 37.3 points preoperatively to 77.8 and 83.2 points at final follow-up (p = 0.137). Nine knees in the HBV group required revision surgery, including seven due to septic loosening and two due to aseptic loosening. Four knees in the control group required revision surgery, including three due to septic loosening and one due to aseptic loosening. Kaplan–Meier survivorship analysis with the revision of either component as an endpoint in the HBV and control groups estimated 96.6% and 98.5% chances of survival for ten years, respectively (p = 0.160). Conclusion. TKA in patients with HBV infection resulted in good clinical outcomes and survivorship. However, there was a higher revision rate over a minimum ten-year follow-up period compared to TKA in patients without HBV infection. Cite this article: Bone Jt Open 2022;3(6):470–474


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1201 - 1209
1 Sep 2011
Peng K Hsu W Shih H Hsieh C Huang T Hsu RW Chang P

In this study of 41 patients, we used proteomic, Western blot and immunohistochemical analyses to show that several reactive oxygen species scavenging enzymes are expressed differentially in patients with primary osteoarthritis and those with non-loosening and aseptic loosening after total hip replacement (THR). The patients were grouped as A (n = 16, primary THR), B (n = 10, fixed THR but requiring revision for polyethylene wear) and C (n = 15, requiring revision due to aseptic loosening) to verify the involvement of the identified targets in aseptic loosening. When compared with Groups A and B, Group C patients exhibited significant up-regulation of transthyretin and superoxide dismutase 3, but down-regulation of glutathione peroxidase 2 in their hip synovial fluids. Also, higher levels of superoxide dismutase 2 and peroxiredoxin 2, but not superoxide dismutase 1, catalase and glutathione perioxidase 1, were consistently detected in the hip capsules of Group C patients.

We propose that dysregulated reactive oxygen species-related enzymes may play an important role in the pathogenesis and progression of aseptic loosening after THR.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 472 - 478
1 Apr 2022
Maccario C Paoli T Romano F D’Ambrosi R Indino C Federico UG

Aims. This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years. Methods. We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up. Results. A total of 86 patients were evaluated at a mean follow-up of 65.4 months (60 to 90). At five-year follow-up, statistically significant improvements (p < 0.001) were found in the mean American Orthopaedic Foot & Ankle Society Ankle Hindfoot Score (from 33.8 (SD 14.3) to 86.1 (SD 8.8)), visual analogue scale for pain (from 8.5 (SD 1.7) to 1.5 (SD 1.2)), Short Form-12 Physical and Mental Component Scores (from 29.9 (SD 6.7) and 43.3 (SD 8.6) to 47.3 (SD 7.5) and 52.2 (SD 8.0), respectively), and mean ankle dorsiflexion and plantarflexion (from 6.2° (SD 5.5°) and 9.6° (SD 5.8°) to 23.9° (SD 7.7°) and 16.9° (SD 7.2°), respectively). Radiologically, the implants maintained neutral alignment without subsidence. Tibial or talar radiolucency was found in eight patients, but none of these patients was symptomatic. At five-year follow up, 97.7% of implants (95% confidence interval 91.2 to 99.4) were free from revision or removal with 84 implants at risk. We recorded two cases (2.3%) of failure for septic loosening. Conclusion. Transfibular TAA is safe and effective with a high survival rate at mid-term follow-up and satisfactory clinical and radiological results. Further studies are required to determine the long-term performance of these implants. Cite this article: Bone Joint J 2022;104-B(4):472–478


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 17 - 17
23 Jun 2023
Schreurs BW van Veghel MH van der Koelen RE Hannink G Rijnen WH
Full Access

Although data on uncemented short stems are available, studies on cemented short-stemmed THAs are limited. These cemented short stems may have inferior long-term outcomes and higher femoral component fracture rates. Hence, we examined the long-term follow-up of cemented short Exeter stems used in primary THA. Within the Exeter stem range, 7 stems have a stem length of 125 mm or less. These stems are often used in small patients, in young patients with a narrow femoral canal or patients with anatomical abnormalities. Based on our local database, we included 394 consecutive cemented stems used in primary THA (n=333 patients) with a stem length ≤125 mm implanted in our tertiary referral center between 1993 and December 2021. We used the Dutch Arthroplasty Registry (LROI) to complete and cross-check the data. Kaplan-Meier survival analyses were performed to determine 20-year survival rates with stem revision for any reason, for septic loosening, for aseptic loosening and for femoral component fracture as endpoints. The proportion of male patients was 21% (n=83). Median age at surgery was 42 years (interquartile range: 30–55). The main indication for primary THA was childhood hip diseases (51%). The 20-year stem survival rate of the short stem was 85.4% (95% CI: 73.9–92.0) for revision for any reason and 96.2% (95%CI: 90.5–98.5) for revision for septic loosening. No stems were revised for aseptic femoral loosening. However, there were 4 stem fractures at 6.6, 11.6, 16.5 and 18.2 years of follow-up. The stem survival with femoral component fracture as endpoint was 92.7% (CI: 78.5–97.6) at 20 years. Cemented short Exeter stems in primary THA show acceptable survival rates at long-term follow-up. Although femoral component fracture is a rare complication of a cemented short Exeter stem, orthopaedic surgeons should be aware of its incidence and possible risk factors


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1489 - 1497
1 Dec 2019
Wang J Ma H Chou TA Tsai S Chen C Wu P Chen W

Aims. The aim of this meta-analysis was to compare the outcome of total elbow arthroplasty (TEA) undertaken for rheumatoid arthritis (RA) with TEA performed for post-traumatic conditions with regard to implant failure, functional outcome, and perioperative complications. Materials and Methods. We completed a comprehensive literature search on PubMed, Web of Science, Embase, and the Cochrane Library and conducted a systematic review and meta-analysis. Nine cohort studies investigated the outcome of TEA between RA and post-traumatic conditions. The preferred reporting items for systematic reviews and meta-analysis (Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)) guidelines and Newcastle-Ottawa scale were applied to assess the quality of the included studies. We assessed three major outcome domains: implant failures (including aseptic loosening, septic loosening, bushing wear, axle failure, component disassembly, or component fracture); functional outcomes (including arc of range of movement, Mayo Elbow Performance Score (MEPS), and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), and perioperative complications (including deep infection, intraoperative fracture, postoperative fracture, and ulnar neuropathy). Results. This study included a total of 679 TEAs for RA (n = 482) or post-traumatic conditions (n = 197). After exclusion, all of the TEAs included in this meta-analysis were cemented with linked components. Our analysis demonstrated that the RA group was associated with a higher risk of septic loosening after TEA (odds ratio (OR) 3.96, 95% confidence interval (CI) 1.11 to 14.12), while there was an increased risk of bushing wear, axle failure, component disassembly, or component fracture in the post-traumatic group (OR 4.72, 95% CI 2.37 to 9.35). A higher MEPS (standardized mean difference 0.634, 95% CI 0.379 to 0.890) was found in the RA group. There were no significant differences in arc of range of movement, DASH questionnaire, and risk of aseptic loosening, deep infection, perioperative fracture, or ulnar neuropathy. Conclusion. The aetiology of TEA surgery appears to have an impact on the outcome in terms of specific modes of implant failures. RA patients might have a better functional outcome after TEA surgery. Cite this article: Bone Joint J 2019;101-B:1489–1497


Bone & Joint Open
Vol. 4, Issue 2 | Pages 79 - 86
10 Feb 2023
McLaughlin JR Johnson MA Lee KR

Aims. The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA). Methods. The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four. Results. Seven femoral components (18%) required revision, and none for septic loosening. Four well fixed stems were removed during acetabular revision and three were revised for late infection. One femoral component (3%) was loose by radiological criteria. The mean Harris Hip Score improved from 47 points (SD 4.62) preoperatively to 83 points (SD 9.27) at final follow-up. With revision for any reason as the endpoint, survival of the femoral component was 80% (95% confidence interval (CI) 61% to 90%) at 32 years. With revision for aseptic loosing femoral component, survival was 99% (95% CI 93% to 99%). Conclusion. With regards to aseptic loosening, the Taperloc femoral component provides excellent fixation at a mean follow-up of 32 years. Cite this article: Bone Jt Open 2023;4(2):79–86


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 52 - 52
23 Feb 2023
Full Access

THA in patients with acetabular bone defects is associated with a high risk of dislocation. Dual mobility (DM) cups are known to prevent and treat chronic instability. The aim of this study was to evaluate the dislocation rate and survival of jumbo DM cups. This was a retrospective, continuous, multicenter study of all the cases of jumbo DM cup implantation between 2010 and 2017 in patients with acetabular bone loss (Paprosky 2A: 46%, 2B: 32%, 2C: 15% and 3A: 6%). The indications for implantation were revisions for aseptic loosening of the cup (n=45), aseptic loosening of the femoral stem (n=3), bipolar loosening (n=11), septic loosening (n=10), periprosthetic fracture (n=5), chronic dislocation (n=4), intraprosthetic dislocation (n=2), cup impingement (n=1), primary posttraumatic arthroplasty (n=8), and acetabular dysplasia (n=4). The jumbo cups used were COPTOS TH (SERF), which combines press-fit fixation with supplemental fixation (acetabular hook, two superior flanges with one to four screws, two acetabular pegs). A bone graft was added in 74 cases (80%). The clinical assessment consisted of the Harris hip score. The primary endpoint was surgical revision for aseptic acetabular loosening or the occurrence of a dislocation episode. In all, 93 patients were reviewed at a mean follow-up of 5.3 ± 2.3 years [0, 10]. As of the last follow-up, the acetabular cup had been changed in five cases: three due to aseptic loosening (3.2%) and two due to infection (2.1%). The survivorship free of aseptic loosening was 96.8%. Three patients (3%) suffered a dislocation. At the last follow-up visit, the mean HSS scores were 72.15, (p < 0.05). Use of a jumbo DM cup in cases of acetabular bone defects leads to satisfactory medium-term results with low dislocation and loosening rates


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 10 - 10
1 Dec 2022
Rizkallah M Ferguson P Basile G Werier JM Kim P Wilson D Turcotte R
Full Access

The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17–86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 96 - 96
1 Dec 2022
Rizkallah M Ferguson P Basile G Werier JM Kim P Wilson D Turcotte R
Full Access

The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17-86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 360 - 360
1 Jul 2011
Ovrenovits M Pakos E Vartholomatos G Mitsionis G
Full Access

The aim of the study to analyze the circulating white blood cells including the intensity expression of surface receptors and cytoplasmic molecules in patients underwent total hip replacement, with either aseptic or septic loosening of hip prostheses in order to identify cell-surface and cytoplasmic markers that could be indicative of early loosening. Flow cytometry was performed in whole peripheral blood samples of 20 patients with loosening (10 septic and 10 aseptic). Ten healthy individuals served a control group. The CD62L, CD18, CD11a, CD11b and CD11c expressions were evaluated. The mean fluorescence intensity (MFI) of CD 18 was decreased on all leukocytes subsets compared to control group. For patients with aseptic loosening we demonstrated an increase of MFI for CD11b in granulocytes and for CD11c in monocytes and granulocytes compared to control group. In patients with septic loosening an increase of MFI for CD 11c was observed in monocytes compared to control group. The comparison between aseptic and septic loosening showed a statistically significant lower CD18 MFI value in granulocytes for aseptic loosening. A trend towards lower MFI values of CD 62L in lymphocytes and granulocytes were observed in aseptic but not in septic loosening patients compared to control group. The present study is the first study in published literature to demonstrate cell surface and cytoplasmic markers in peripheral blood indicative of loosening of THAs by means of flow cytometry


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 910 - 914
1 Aug 2019
Kiran M Donnelly TD Armstrong C Kapoor B Kumar G Peter V

Aims. Prosthetic joint infection (PJI) and aseptic loosening in total hip arthroplasty (THA) can present with pain and osteolysis. The Musculoskeletal Infection Society (MSIS) has provided criteria for the diagnosis of PJI. The aim of our study was to analyze the utility of F18-fluorodeoxyglucose (FDG) positron emission tomography (PET) CT scan in the preoperative diagnosis of septic loosening in THA, based on the current MSIS definition of prosthetic joint infection. Patients and Methods. A total of 130 painful unilateral cemented THAs with a mean follow-up of 5.17 years (. sd. 1.12) were included in this prospective study. The mean patient age was 67.5 years (. sd. 4.85). Preoperative evaluation with inflammatory markers, aspiration, and an F18 FDG PET scan were performed. Diagnostic utility tests were also performed, based on the MSIS criteria for PJI and three samples positive on culture alone. Results. The mean erythrocyte sedimentation rate, C-reactive protein, and white cell count were 47.83 mm/hr, 25.21 mg/l, and 11.05 × 10. 9. /l, respectively. The sensitivity, specificity, accuracy, negative predictive value, and false-positive rate of FDG PET compared with MSIS criteria were 94.87%, 38.46 %, 56.38%, 94.59 %, and 60.21%, respectively. The false-positive rate of FDG PET compared with culture alone was 77.4%. Conclusion. FDG PET has a definitive role in the preoperative evaluation of suspected PJI. This the first study to evaluate its utility based on MSIS criteria and compare it with microbiology results alone. However, FDG PET has a high false-positive rate. Therefore, we suggest that F18 FDG PET is useful in confirming the absence of infection, but if positive, may not be confirmatory of PJI. Cite this article: Bone Joint J 2019;101-B:910–914


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 331 - 331
1 Jul 2011
Bjerkan G Bergh K Witso E
Full Access

Aims: The symptoms of aseptic and septic prosthetic joint loosening may be similar, and identification of low-grade prosthetic infection based only on clinical history and physical examination has a reported low sensitivity. In a prospective study we explored to what extent a thorough examination of the patient’s history of sickness and a standardized preoperative clinical examination could help the surgeon to identify cases of septic loosening. Methods: We included 54 patients undergoing revision surgery due to loosening of a total hip or knee prosthesis. Preoperatively a standardized form which included data regarding the patient’s history of sickness was obtained and a physical examination was performed. Postoperatively a final diagnose was made based on microbiological testing, which in addition to routine culture, included sonication of the prosthesis and nucleic acid based diagnostics (PCR). Data from the preoperative examination was evaluated in relation to the final diagnose (chi-square test and Student’s t-test), and the sensitivity and specificity for diagnosing a septic loosening was calculated for each preoperative finding. Results: According to the final diagnose, 21 patients had a septic loosening and 33 patients had an aseptic loosening. In the septic group and aseptic group the following anamnestic data was registered: Pain during rest: 16/21 vs. 7/33 (p < 0.001). Prior history of soft tissue debridement: 11/21 vs. 4/33 (p = 0.001). Prior prosthetic revision surgery: 13/21 vs. 8/33 (p = 0.006). Time from index operation to revision: 45 (5 – 144) moths vs. 159 (22–390) moths, (p = 0.02). Time from index operation to debut of prosthetic assosiated dyscomfort: 10 (0–110) moths vs. 120 (0–240) moths, (p < 0.001). The calculated sensitivity (se) and spesifisity (sp) for the pre-operative findings were: Existence of prosthetic related pain during rest: 79% se, 79% sp; history of soft tissue revision in the affected joint 52% se, 88% sp; history of prior exchange prosthetic revision in the affected joint 62% se, 76% sp, respectively. Conclusion: We advise a carefully obtained history from every patient presenting with loosening of implanted prosthetic components for identification of a potential low grade infection. In particular, pain during rest has a notable sensitivity and specificity. A prior history of soft tissue revision also strongly indicates a septic prosthetic loosening


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 25 - 25
1 Mar 2013
Bruni D Iacono F Presti ML Sharma B Raspugli G Marcacci M
Full Access

INTRODUCTION. Conventional surgical exposures are usually inadequate for 2-stage revision knee replacement ofinfected implants. Reduced range of motion, extensor mechanism stiffness, peripatellar contracture and soft tissue scarring make patellar eversion difficult and forced eversion places the integrity of the extensor mechanism at risk. On the contrary, a wide exposure is fundamental to allow complete cement spacer removal, soft tissue balancing, management of bone loss and reimplantation without damaging periarticular soft tissues. OBJECTIVES. To compare the long-term clinical, functional and radiographic results and the reinfection rate of the quadriceps snip approach and the tibial tubercle osteotomy in 2-stage revision knee replacement performed for septic loosening of the primary implant. METHODS. In our department, 87 patients had a 2 stage revision knee replacement for septic loosening of the primary implant between 1996 and 2008. In all patients, first stage consisted of primary implant removal, extensive soft tissue debridement and positioning of a static antibiotic loaded cement spacer. The timing for reimplantation was decided basing on negative clinical and laboratory (ESR, CRP) signs and negative Leukoscan results. For reimplantation, a quadriceps snip was used in patients with an intraoperative flexion >90° (Group A) while a tibial tubercle osteotomy (Group B) was used in patients with an intraoperative flexion <90°. RESULTS. At observation point, 4 patients died for reasons unrelated to surgery, leaving 42 patients in Group A and 41 in Group B. We had a total amount of 10 recurrent infections (11%) after reimplantation, 7 patients in Group A and 3 patients in Group B (p<0.005). Patients with a reinfection in Group A were treated with a knee fusion in 4 cases, a rerevision in 2 cases and an amputation above the knee in 1 case, while all those with a reinfection in Group B had a knee fusion. According to HSS score, 11 patients were rated as Excelent/Good in Group A and 9 patients in Group B (p=n.s.). Three patients had a major complication in Group A and 0 patients in Group B (p=0.005). No differences were found between the two groups regarding range of motion and subjective satisfaction. CONCLUSION. Tibial tubercle osteotomy is a safe procedure to obtain a wide exposure in 2-stage revision knee replacement performed for septic loosening of the primary implant and it is effective in reducing reinfection rate without compromising clinical results and range of motion


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 107 - 107
1 Jan 2016
Kindsfater K Sherman C Bureau C
Full Access

Introduction. Revision TKA can be a difficult and complex procedure. Bone quality is commonly compromised and stem fixation is required in many cases to provide stability of the prosthetic construct. However, utilization of diaphyseal engaging stems adds complexity to the case and can present technical challenges to the surgeon. Press fit metaphyseal sleeves can provide stable fixation of the construct without the need for stems and allows for biologic ingrowth of the prosthesis. Metaphyseal sleeves simplify the revision procedure by avoiding the need to prepare the diaphysis for stems, alleviating the need for offset stems and decreasing the risk of intra-operative complications. The ability to obtain biologic fixation in the young patient is also appealing. This study reports on the author's mid-term experience with this novel technique. Methods. Between May 2007 and June 2009 the author performed 17 revisions TKA that utilized press-fit metaphyseal sleeves without stems on either the tibial side of the joint, the femoral side of the joint or both. Twenty six sleeves were implanted altogether (13 tibial, 13 femoral). Patients were limited to touch down weight bearing for 6 weeks post-operatively. The patients were followed prospectively with clinical and radiographic follow-up at routine intervals. Results. Average clinical and radiographic F/U for the cohort was 57 months (range 30 – 77). Fourteen of seventeen patients had a minimum of 4 years F/U. Average age at the time of surgery was 58 years (range 46–72) and average BMI was 32.4. Indications for the index revision included nine knees with aseptic loosening and / or osteolysis, two knees for septic loosening, two knees for instability and 4 knees for pain / stiffness or other causes. ROM at pre-op and latest F/U averaged 2–108 deg and 0–117 deg respectively. Knee Society Scores at pre-op and latest F/U averaged 35 and 86 respectively (range 57–100). Survivorship analysis revealed 25 of 26 sleeves (96%) to still be in situ at latest F/U. One tibial sleeve was revised at 30 months for septic loosening. Radiographic analysis revealed 22 of the remaining 25 sleeves (88%) to be ingrown. Two tibial sleeves and one femoral sleeve exhibit stable fibrous fixation and are asymptomatic. Conclusions. Press-fit metaphyseal sleeves utilized without stems appear to provide excellent stability of the revision TKA construct at mid-term F/U. Biologic fixation appears to be present in the majority of cases. This ability to obtain reliable osseointegration of the revision construct is appealing, especially in the younger revision patient. The sleeves have proven easy to use and there have been no intra-operative complications. This technique appears to provide a simple, but robust alternative when compared to revision TKA with stems in appropriate cases. Further F/U of this cohort is necessary to evaluate long term results


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1148 - 1153
1 Sep 2009
Schreurs BW Keurentjes JC Gardeniers JWM Verdonschot N Slooff TJJH Veth RPH

We present an update of the clinical and radiological results of 62 consecutive acetabular revisions using impacted morsellised cancellous bone grafts and a cemented acetabular component in 58 patients, at a mean follow-up of 22.2 years (20 to 25). The Kaplan-Meier survivorship for the acetabular component with revision for any reason as the endpoint was 75% at 20 years (95% confidence interval (CI) 62 to 88) when 16 hips were at risk. Excluding two revisions for septic loosening at three and six years, the survivorship at 20 years was 79% (95% CI 67 to 93). With further exclusions of one revision of a well-fixed acetabular component after 12 years during a femoral revision and two after 17 years for wear of the acetabular component, the survivorship for aseptic loosening was 87% at 20 years (95% CI 76 to 97). At the final review 14 of the 16 surviving hips had radiographs available. There was one additional case of radiological loosening and four acetabular reconstructions showed progressive radiolucent lines in one or two zones. Acetabular revision using impacted large morsellised bone chips (0.5 cm to 1 cm in diameter) and a cemented acetabular component remains a reliable technique for reconstruction, even when assessed at more than 20 years after surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1417 - 1421
1 Nov 2008
de Kam DCJ Klarenbeek RLWA Gardeniers JWM Veth RPH Schreurs BW

We evaluated the outcome of 104 consecutive primary cemented Exeter femoral components in 78 patients (34 men, 44 women) under the age of 40 years who underwent total hip replacement between October 1993 and May 2004. The mean age at operation was 31 years (16 to 39). No hip was lost to follow-up, but three patients (four hips) died. None of the deaths were related to the surgery. At a mean follow-up of 6.2 years (2 to 13), three femoral components had been revised for septic loosening. Using Kaplan-Meier survival analysis, the seven-year survival of the component with revision for any reason as the endpoint was 95.8% (95% confidence interval 86.67 to 98.7). The seven-year survival with aseptic femoral loosening as the endpoint was 100% (95% confidence interval 100). The cemented Exeter femoral component in patients under the age of 40 shows promising medium-term results. As it is available in a wide range of sizes and offsets, we could address all types of anatomical variation in this series without the need for custom-made components


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1073 - 1076
1 Aug 2005
Cross MJ Parish EN

We prospectively reviewed 1000 consecutive patients who underwent a cementless, hydroxyapatite-coated, stemless, total knee replacement over a period of nine years. Regular post-operative clinical follow-up was performed using the Knee Society score. The mean pre-operative score was 96, improving to 182 and 180 at five and ten years, respectively. To date, there have been seven (0.5%) cases which required revision, primarily for septic loosening (four cases), with low rates of other post-operative complications. The cumulative survival at ten years with revision as the end-point, was 99.14% (95% confidence interval 92.5 to 99.8). These results support the use of hydroxyapatite in a cementless total knee replacement since it can give reliable fixation with an excellent clinical and functional outcome


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 575 - 575
1 Oct 2010
Salama A Nicoletti S Stanley D
Full Access

At our institution between 1994 and 2003 a total of 36 revision total elbow Arthroplasties were performed in 34 patients. We clinically reviewed 25 patients and reviewed the notes and x-rays of all of them. Of eleven who were not reviewed clinically seven had died from an unrelated cause and four were unable to attend because of illness but we were able to include them as sufficient data were available in the notes. There were 24 female and 12 male, Average age was 67 years and twelve had elbow Arthroplasty in a non-dominant side. The average follow up was 6 years (range 5–13 years). The mean period between the primary and revision surgery was sixty three months (range 3–240 months). The indication for surgery was mainly for aseptic loosening in 15 cases, followed by septic loosening in twelve. All cases of septic loosening had two stage revisions. Other reasons for revision in this series include unstable elbows, implant fracture and peri-prosthetic fractures. Twelve of these revisions had a further revision for a variety of reasons at an average period of twenty eight months. Seven patients had thirteen complications in this series, two radial nerve palsies (one recovered), one distal humeral fracture, five cortical perforations and five triceps weakness. Most of the patients are satisfied with their elbows. The mean Mayo elbow Performance Score was 79 points. We conclude that revision Elbow Arthroplasty is a specialized surgery which is technically demanding, with high risk of complications and high re-revision rate and therefore, should be done in a specialised centres


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 164 - 165
1 Mar 2008
Fravisini M Pellacani A Stagni C Veronesi M Dallari D Giunti A
Full Access

Girdlestone’s arthroplasty is often used to treat septic loosening of hip prostheses. Although this operation provides goodresults with regards to pain and loosening, it causes instability and in the hip and limb shortening that force the patient to use walking aids. From 1990 to 1999 we treated ten cases of revisionhip arthroplasty after Girdlestone’s arthroplasty. Girdleston e’sarthroplasty was carried out in all cases due to sepsis in the previousimplant. Preoperatively all patients underwent granulocyte-labeledscintigraphy. For clinical evaluation we used the Merle D’Aubignè score. From 1990 to 1999 we treated ten cases of revisionhip arthroplasty after Girdlestone’s arthroplasty. Girdleston e’sarthroplasty was carried out in all cases due to sepsis in the previousimplant. Preoperatively all patients underwent granulocyte-labeledscintigraphy. For clinical evaluation we used the Merle D’Aubignè score. Girdlestone’s arthroplasty is very effective for treating septic loosening of hip prostheses, but it causes severe walking impediment. Revision surgery restores limb length and walking. Patients that undergo this treatment should be checked for residual sepsis, which may jeopardize the operation. Currently we are experimenting with spacers with antibiotics and our initial results are promising