Two stage revision for infection is considered the gold standard with a success rate of 80–90%. Overall functional outcomes of these patients are commonly overlooked. There is a trend towards single stage revision to improve functional outcomes. We examined the functional scores of 2 stage
Introduction. Metal on metal hip resurfacing (MMHR) has been advocated for the younger patient for several reasons including for the preservation of bone stock and ease of
A lack of supporting clinical studies have been published to determine the ideal length of intramedullary nail in fixation of trochanteric fractures of the hip. Nevertheless, there has been a trend to use shorter intramedullary nails for the internal fixation of trochanteric hip fractures. Our aim was to determine if the length of nail affected the outcome. We randomized 229 patients with a trochanteric hip fracture between two implants: a ‘standard’ nail of 220 mm and a shorter nail of 175 mm, which had decreased proximal angulation (4° vs 7°) and a reduced diameter at the level of the lesser trochanter. Patients were followed up for one year by a nurse blinded to the type of implant used to determine if there were differences in mobility and pain with two nail designs. Pain was assessed on a scale of 1 (none) to 8 (severe and constant) and mobility on a scale of 1 (full mobility) to 9 (immobile).Aims
Methods
This study describes and compares the operative management and outcomes in a consecutive case series of patients with dislocated hemiarthroplasties of the hip, and compares outcomes with those of patients not sustaining a dislocation. Of 3326 consecutive patients treated with hemiarthroplasty for fractured neck of femur, 46 (1.4%) sustained dislocations. Of the 46 dislocations, there were 37 female patients (80.4%) and nine male patients (19.6%) with a mean age of 83.8 years (66 to 100). Operative intervention for each, and subsequent dislocations, were recorded. The following outcome measures were recorded: dislocation; mortality up to one-year post-injury; additional surgery; residential status; mobility; and pain score at one year.Aims
Patients and Methods
The aim of this study was to compare the functional and radiological
outcomes in patients with a displaced fracture of the hip who were
treated with a cemented or a cementless femoral stem. A four-year follow-up of a randomized controlled study included
141 patients who underwent surgery for a displaced femoral neck
fracture. Patients were randomized to receive either a cemented
(n = 67) or a cementless (n = 74) stem at hemiarthroplasty (HA;
n = 83) or total hip arthroplasty (THA; n = 58).Aims
Patients and Methods
We compared a new fixation system, the Targon
Femoral Neck (TFN) hip screw, with the current standard treatment of
cannulated screw fixation. This was a single-centre, participant-blinded,
randomised controlled trial. Patients aged 65 years and over with
either a displaced or undisplaced intracapsular fracture of the
hip were eligible. The primary outcome was the risk of revision
surgery within one year of fixation. A total of 174 participants were included in the trial. The absolute
reduction in risk of revision was of 4.7% (95% CI 14.2 to 22.5)
in favour of the TFN hip screw (chi-squared test, p = 0.741), which
was less than the pre-specified level of minimum clinically important
difference. There were no significant differences in any of the
secondary outcome measures. We found no evidence of a clinical difference in the risk of
revision surgery between the TFN hip screw and cannulated screw
fixation for patients with an intracapsular fracture of the hip. Cite this article:
United Kingdom National Institute for Health
and Clinical Excellence guidelines recommend the use of total hip replacement
(THR) for displaced intracapsular fractures of the femoral neck
in cognitively intact patients, who were independently mobile prior
to the injury. This study aimed to analyse the risk factors associated
with revision of the implant and mortality following THR, and to
quantify risk. National Joint Registry data recording a THR performed
for acute fracture of the femoral neck between 2003 and 2010 were
analysed. Cox proportional hazards models were used to investigate
the extent to which risk of revision was related to specific covariates.
Multivariable logistic regression was used to analyse factors affecting
peri-operative mortality (<
90 days). A total of 4323 procedures
were studied. There were 80 patients who had undergone revision
surgery at the time of censoring (five-year revision rate 3.25%, 95%
confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients
died within 90 days. After adjusting for patient and surgeon characteristics,
an increased risk of revision was associated with the use of cementless
prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021).
Revision was independent of bearing surface and head size. The risk
of mortality within 90 days was significantly increased with higher
American Society of Anesthesiologists (ASA) grade (grade 3: odds
ratio (OR) 4.04, p <
0.001; grade 4/5: OR 20.26, p <
0.001;
both compared with grades 1/2) and older age (≥ 75 years: OR 1.65,
p = 0.025), but reduced over the study period (9% relative risk reduction
per year). THR is a good option in patients aged <
75 years and with
ASA 1/2. Cementation of the femoral component does not adversely
affect peri-operative mortality but improves survival of the implant
in the mid-term when compared with cementless femoral components.
There are no benefits of using head sizes >
28 mm or bearings other
than metal-on-polyethylene. More research is required to determine
the benefits of THR over hemiarthroplasty in older patients and
those with ASA grades >
2.
We undertook a prospective randomised controlled trial involving 400 patients with a displaced intracapsular fracture of the hip to determine whether there was any difference in outcome between treatment with a cemented Thompson hemiarthroplasty and an uncemented Austin-Moore prosthesis. The surviving patients were followed up for between two and five years by a nurse blinded to the type of prosthesis used. The mean age of the patients was 83 years (61 to 104) and 308 (77%) were women. The degree of residual pain was less in those treated with a cemented prosthesis (p <
0.0001) three months after surgery. Regaining mobility was better in those treated with a cemented implant (p = 0.005) at six months after operation. No statistically significant difference was found between the two groups with regard to mortality, implant-related complications, re-operations or post-operative medical complications. The use of a cemented Thompson hemiarthroplasty resulted in less pain and less deterioration in mobility than an uncemented Austin-Moore prosthesis with no increase in complications.
We aimed to identify variables associated with clinical and radiological outcome following fractures of the acetabulum associated with posterior dislocation of the hip. Using a prospective database of 1076 such fractures, we identified 109 patients with this combined injury managed operatively within three weeks and followed up for two or more years. The patients had a mean age of 42 years (15 to 79), 78 (72%) were male, and 84 (77%) had been involved in motor vehicle accidents. Using multivariate analysis the quality of reduction of the fracture was identified as the only significant predictor of radiological grade, clinical function and the development of post-traumatic arthritis (p <
0.001). All patients lacking anatomical reduction developed arthritis whereas only 25.5% (24 patients) with an anatomical reduction did so (p = 0.05). The quality of the reduction of the fracture is the most important variable in forecasting the outcome for patients with this injury. The interval to reduction of the dislocation of the hip may be less important than previously described.
We studied 217 patients with an unstable trochanteric or subtrochanteric fracture who had been randomly allocated to treatment by either internal fixation with a standard Gamma nail (SGN) or a Medoff sliding plate (MSP, biaxial dynamisation mode). Their mean age was 84 years (65 to 99) and they were reviewed at four and 12 months after surgery. Assessments of outcome included general complications, technical failures, revision surgery, activities of daily living (ADL), hip function (Charnley score) and the health-related quality of life (HRQOL, EQ-5D). The rate of technical failure in patients with unstable trochanteric fractures was 6.5% (6/93) (including intra-operative femoral fractures) in the SGN group and 5.2% (5/96) in the MSP group. In patients with subtrochanteric fractures, there were no failures in the SGN group (n = 16) and two in the MSP group (n = 12). In the SGN group, there were intra-operative femoral fractures in 2.8% (3/109) and no post-operative fractures. There was a reduced need for revision surgery in the SGN group compared with the MSP group (8.3%; 9/108; p = 0.072). The SGN group also showed a lower incidence of severe general complications (p <
0.05) and a trend towards a lower incidence of wound infections (p = 0.05). There were no differences between the groups regarding the outcome of ADL, hip function or the HRQOL. The reduction in the HRQOL (EQ-5Dindexscore) was significant in both groups compared with that before the fracture (p <
0.005). Our findings indicate that the SGN showed good results in both trochanteric and subtrochanteric fractures. The limited number of intra-operative femoral fractures did not influence the outcome or the need for revision surgery. Moreover, the SGN group had a reduced number of serious general complications and wound infections compared with the MSP group. The MSP in the biaxial dynamisation mode had a low rate of failure in trochanteric fractures but an unacceptably high rate when used in the biaxial dynamisation mode in subtrochanteric fractures. The negative influence of an unstable trochanteric or subtrochanteric fracture on the quality of life was significant regardless of the surgical method.