Advertisement for orthosearch.org.uk
Results 1 - 20 of 46
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 46 - 52
1 Jan 2019
León SA Mei XY Safir OA Gross AE Kuzyk PR

Aims. The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function. Patients and Methods. We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score. Results. A total of 14 grafts (23.3%) failed at a mean of 8.6 years (1.4 to 20.1). Graft survivorship was 87.3% (95% confidence interval (CI) 79.0 to 96.6), 85.0% (95% CI 75.8 to 95.3), 74.8% (95% CI 62.2 to 90.0), 65.2% (95% CI 49.9 to 85.2), and 59.8% (95% CI 43.5 to 82.1) at five, ten, 15, 20, and 25 years, respectively. A total of 23 patients (38.3%) developed complications, and 26 (43.3%) had a further operation. Persistent postoperative malalignment occurred more frequently in failed grafts (28.6% vs 4.3%; p = 0.023), and was a risk factor for graft failure (hazard ratio 6.55; 95% CI 1.61 27.71; p = 0.009). The mean mHSS score improved from 74.1 (40 to 91) preoperatively to 89.0 (66 to 100) at final follow-up (p < 0.001). Conclusion. Femoral condylar FOCA with concomitant realignment osteotomy provides excellent long-term graft survival and reliable functional improvement. Persistent malalignment may increase the risk for graft failure


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 43 - 43
1 Jul 2022
Bailey M Dewan V Al-Hourani K Metcalfe A Hing C
Full Access

Abstract. Introduction. The paediatric population present unique challenges to the knee surgeon, particularly when treating recurrent patellofemoral instability(PFI), the management of which is poorly standardised. Through the EPPIC BASK National Trainee Collaborative, we aimed to identify which procedures (and in which combination) are being used to surgically manage recurrent PFI in skeletally immature patients across the UK. Methods. A retrospective national service evaluation via a trainee collaborative analysing local trust data between 1st January 2014 and 31st December 2019. Data from institutions registered for EPPIC was compiled and compared to the national guidelines for adults. Results. A total of 333 patients were classified as skeletally immature(radiologically open physes) across 28 hospitals. Mean age was 14.1 years(+/- 4.5) with 64.9% being female. Mean number of procedures performed was 11.9 (+/-16.4). Isolated medial patellofemoral ligament reconstruction (MPFLR) was the most common procedure, performed in 65.8% of patients. Combined MPFLR and TTO was undertaken in 13.2% of patients. Proximal realignment surgery was performed in 5.1% of patients. Lateral releases were performed in 18.3% of patients with 8.4% performed in isolation. Conclusion. This study highlights the national variation in surgical treatment of PFI in skeletally immature patients. The guidance for adults cannot be applied universally to the skeletally immature, and it not always acceptable to delay treatment until physes close. This lack of standardisation within the UK in the management of recurrent PFI in skeletally immature patients highlights the need for a national consensus in appropriate surgical management of this patient population


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 727 - 735
1 Jun 2020
Burger JA Dooley MS Kleeblad LJ Zuiderbaan HA Pearle AD

Aims. It remains controversial whether patellofemoral joint pathology is a contraindication to lateral unicompartmental knee arthroplasty (UKA). This study aimed to evaluate the effect of preoperative radiological degenerative changes and alignment on patient-reported outcome scores (PROMs) after lateral UKA. Secondarily, the influence of lateral UKA on the alignment of the patellofemoral joint was studied. Methods. A consecutive series of patients who underwent robotic arm-assisted fixed-bearing lateral UKA with at least two-year follow-up were retrospectively reviewed. Radiological evaluation was conducted to obtain a Kellgren Lawrence (KL) grade, an Altman score, and alignment measurements for each knee. Postoperative PROMs were assessed using the Kujala (Anterior Knee Pain Scale) score, Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), and satisfaction levels. Results. A total of 140 knees (130 patients) were identified for analysis. At mean 4.1 years (2.0 to 8.5) follow-up, good to excellent Kujala scores were reported. The presence of mild to moderate preoperative patellofemoral joint osteoarthritis had no impact on these scores (KL grade 0 vs 1 to 3, p = 0.203; grade 0 to 1 vs 2 to 3, p = 0.674). Comparable scores were reported by patients with osteoarthritis (Altman score of ≥ 2) evident on either the medial or lateral patellofemoral joint facet (medial, p = 0.600 and lateral, p = 0.950). Patients with abnormal patellar congruence and tilt angles (≥ 17° and ≥ 14°, respectively) reported good to excellent Kujala scores. Furthermore, lateral UKA resulted in improvements to patellofemoral alignment. Conclusion. This is the first study demonstrating that mild to moderate preoperative radiological degenerative changes and malalignment of the patellofemoral joint are not associated with poor patient-reported outcomes at mid-term follow-up after lateral fixed-bearing UKA. Our data suggest that this may be explained by realignment of the patella and thereby redistribution of loads across the patellofemoral joint. Cite this article: Bone Joint J 2020;102-B(6):727–735


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 26 - 26
1 Oct 2020
Gustke KA
Full Access

Introduction. The purpose of this study was to determine if better outcomes occur with use of robotic-arm assistance by comparing consecutive series of non-robotic assisted (NR-TKA) and robotic-arm assisted (NR-TKA) total knee arthroplasties with the same implant. Methods. 80 NR-TKAs and then 101 RA-TKAs were performed consecutively. 70 knees in each group that had a minimum two-year follow-up were retrospectively reviewed. Range of motion, Knee Society (KS) scores, and forgotten joint scores (FJS) were compared using Mann-Whitney U tests. Tourniquets, used for all cases, had their inflation time recorded. Component realignment to minimize soft tissue releases was used in both groups with the goal to stay within a mechanical alignment of 3° of varus to 2° of valgus. The use of soft tissue releases for balance were compared. Results. There were no statistical differences in baseline characteristics including pre-operative Knee Society scores between cohorts. The two-year NR-TKA and RA-TKA median KS knee and functional scores were 99.0 and 90.0 and 100.0 and 100.0 respectively. Mann-Whitney U test indicated a statistically significant difference in KS-KS (p<.00001) and near statistically significant difference in KS-FS (p=0.075). The 10-point higher KS-FS is considered a minimal clinically important difference. The median FJS at two years for the NR-TKA was 61.5 and the RA-TKA was 75.0. Although not statistically significant (p=0.1556), the 13.5-point increase in the RA-TKA cohort also represents a minimal clinically important difference. RA-TKA patients had statistically significant 5° higher knee flexion (p<.00001). Desired post-operative coronal alignment was present in 92.9% of NR-TKAs and 94.3% of RA-TKAs. 28.6% more of the RA-TKA cases were able to be balanced without a soft tissue release. Median tourniquet time was only 3.9 minutes longer for the robotic-arm assisted cohort. Conclusion. This comparison study demonstrates potential benefits in use of robotic-arm assistance over manual instrumentation in TKA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 48 - 48
1 Mar 2012
van Niekerk L Papapalexandris S Dogiparthi K
Full Access

Purpose. To assess the midterm functional results after Medial Patellofemoral Ligament (MPFL) reconstruction with single semitendinosis autograft in patients with patellofemoral instability. Methods - Results. Forty six knees (45 patients) with patellofemoral instability were treated with surgical stabilisation of the patella with a single semitendinosis autograft and followed up for a minimum of 24 months. The average follow-up was 33.5 months (range 24-54 months). Clinical evidence of patellar instability and radiological (MRI) evidence of MPFL rupture or deficiency was documented prior to surgery. The average post injury interval was 22.3 months. Ipsilateral joint co-morbidities included previous lateral release or distal realignment (n=10), patellofemoral joint (PFJ) dysplasia (n=14) and concurrent ACL, PCL and/or MCL rupture (n=6). Knee function was assessed preoperatively and postoperatively with the use of Kujala, Tegner, Lysholm and International Knee Documentation Committee (IKDC) scores. There were 34 male and 11 female patients with a mean age of 32.5 years (range 17 - 60 years). All measured knee function scores improved postoperatively. Kujala score improved from 58 to 77 (95%CI +/− 9.71). Tegner score improved from 3 to 5 (95%CI+/− 0.65). IKDC score improved from 51 to 75 (95%CI +/− 5.27) and Lysholm score improved from 59 to 79 (95%CI +/− 6.5). Conclusions. MPFL reconstruction with semitendinosis autograft is an effective treatment at a minimum of 24 months (midterm) follow-up in patients with patellofemoral instability even in the presence of heterogeneous knee co-morbidities such as PFJ dysplasia, previous lateral release and failed realignment surgery


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 657 - 662
1 Jun 2022
Barlow T Coco V Shivji F Grassi A Asplin L Thompson P Metcalfe A Zaffagnini S Spalding T

Aims

Meniscal allograft transplantation (MAT) for patients with symptomatic meniscal loss has demonstrated good clinical results and survivorship. Factors that affect both functional outcome and survivorship have been reported in the literature. These are typically single-centre case series with relatively small numbers and conflicting results. Our aim was to describe an international, two-centre case series, and identify factors that affect both functional outcome and survival.

Methods

We report factors that affect outcome on 526 patients undergoing MAT across two sites (one in the UK and one in Italy). Outcomes of interest were the Knee injury and Osteoarthritis Outcome Score four (KOOS4) at two years and failure rates. We performed multiple regression analysis to examine for factors affecting KOOS, and Cox proportional hazards models for survivorship.


Bone & Joint Open
Vol. 4, Issue 12 | Pages 948 - 956
15 Dec 2023
Vella-Baldacchino M Webb J Selvarajah B Chatha S Davies A Cobb JP Liddle AD

Aims

With up to 40% of patients having patellofemoral joint osteoarthritis (PFJ OA), the two arthroplasty options are to replace solely the patellofemoral joint via patellofemoral arthroplasty (PFA), or the entire knee via total knee arthroplasty (TKA). The aim of this study was to assess postoperative success of second-generation PFAs compared to TKAs for patients treated for PFJ OA using patient-reported outcome measures (PROMs) and domains deemed important by patients following a patient and public involvement meeting.

Methods

MEDLINE, EMBASE via OVID, CINAHL, and EBSCO were searched from inception to January 2022. Any study addressing surgical treatment of primary patellofemoral joint OA using second generation PFA and TKA in patients aged above 18 years with follow-up data of 30 days were included. Studies relating to OA secondary to trauma were excluded. ROB-2 and ROBINS-I bias tools were used.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 240 - 248
1 Mar 2024
Kim SE Kwak J Ro DH Lee MC Han H

Aims

The aim of this study was to evaluate whether achieving medial joint opening, as measured by the change in the joint line convergence angle (∆JLCA), is a better predictor of clinical outcomes after high tibial osteotomy (HTO) compared with the mechanical axis deviation, and to find individualized targets for the redistribution of load that reflect bony alignment, joint laxity, and surgical technique.

Methods

This retrospective study analyzed 121 knees in 101 patients. Patient-reported outcome measures (PROMs) were collected preoperatively and one year postoperatively, and were analyzed according to the surgical technique (opening or closing wedge), postoperative mechanical axis deviation (deviations above and below 10% from the target), and achievement of medial joint opening (∆JLCA > 1°). Radiological parameters, including JLCA, mechanical axis deviation, and the difference in JLCA between preoperative standing and supine radiographs (JLCAPD), an indicator of medial soft-tissue laxity, were measured. Cut-off points for parameters related to achieving medial joint opening were calculated from receiver operating characteristic (ROC) curves.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 109 - 116
8 Feb 2024
Corban LE van de Graaf VA Chen DB Wood JA Diwan AD MacDessi SJ

Aims

While mechanical alignment (MA) is the traditional technique in total knee arthroplasty (TKA), its potential for altering constitutional alignment remains poorly understood. This study aimed to quantify unintentional changes to constitutional coronal alignment and joint line obliquity (JLO) resulting from MA.

Methods

A retrospective cohort study was undertaken of 700 primary MA TKAs (643 patients) performed between 2014 and 2017. Lateral distal femoral and medial proximal tibial angles were measured pre- and postoperatively to calculate the arithmetic hip-knee-ankle angle (aHKA), JLO, and Coronal Plane Alignment of the Knee (CPAK) phenotypes. The primary outcome was the magnitude and direction of aHKA, JLO, and CPAK alterations.


Bone & Joint Open
Vol. 4, Issue 4 | Pages 262 - 272
11 Apr 2023
Batailler C Naaim A Daxhelet J Lustig S Ollivier M Parratte S

Aims

The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients.

Methods

All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m2 (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA), femoral bowing angle (FBow), the distance between the knee centre and the top of the FBow (DK), and the angle representing the FBow impact on the knee (C’KS angle).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 25 - 25
1 Oct 2018
Geller JA Sarpong NO Grosso M Lakra A Jennings E Heller MS Shah RP Cooper HJ
Full Access

Introduction. The success of total knee arthroplasty (TKA) necessitates precise osteotomies and soft tissue balancing to realign the lower extremity to a neutral mechanical axis. While technological advances have facilitated precise osteotomies, soft tissue balancing has traditionally relied mostly on surgeons’ subjective and variable tactile feedback. As soft tissue imbalance accounts for 35% of early TKA revisions in North America, we aimed to compare outcomes when TKA was balanced free-hand versus a sensor-guided balancing device (VERASENSE, OrthoSensor, Inc (Dania, FL)). Methods. In a randomized-controlled fashion, patients underwent primary TKA soft tissue balancing either free-hand or with VERASENSE (Orthosensor Inc, Dania FL) at our institution beginning January 2018. With VERASENSE, soft-tissue balancing is considered when the pressure difference between the medial and lateral knee compartments was less than 15 pounds. Data regarding patient-reported outcomes, knee range of motion (ROM), pain level, opioid consumption, inpatient ambulation distance, length of stay (LOS), and incidence of arthrofibrosis was collected and analyzed in a two-year minimum follow-up and target patient goal of 120 patients. Results. The study cohort thus far consists of 53 patients, average age 72.4 ± 8.8 years. Soft-tissue balance was conducted freehand in 23 patients and the VERASENSE was used in 30 patients. In the free-hand cohort, preoperative patient-reported outcomes for SF-12 Physical, Mental, WOMAC (pain, stiffness, function) parameters, and knee society function score (KSFS) were 39.3, 45.8, 47.7, 37.5, 48.1, and 50.0, respectively and post-operative at 3 months were 45.0, 53.0, 79.5, 72.5, 81.0, and 72.5, respectively; difference between preoperative and post-operative ROM was +8.4 degrees; average VAS pain score in the first 3 post-operative days was 2.9 ± 2.3; average opioid consumption was 100.7 ± 103.3 mg morphine equivalents; average inpatient ambulation per day was 267.9 ± 187.4 feet; average LOS was 2.3 days. In the VERASENSE cohort, patient reported outcomes for SF-12 Physical, Mental, WOMAC (pain, stiffness, function) parameters, and knee society function score (KSFS) were 38.2, 48.6, 40.1, 30.3, 40.0, and 48.7, respectively and post-operative at 3 months were 41.9, 47.6, 67.2, 59.7, 69.1, and 56.7; difference between preoperative and post-operative ROM was +3.9 degrees; average VAS pain score in the first 3 post-operative days was 2.9 ± 2.3; average opioid consumption was 105.8 ± 86.7 mg morphine equivalents; average inpatient ambulation was 384.6 ± 316.1 feet; average LOS was 2.1 days. There was no incidence of arthrofibrosis and subsequent manipulation under anesthesia in the trial. Conclusion. Short-term follow up of this randomized-controlled trial demonstrates equivalent patient-reported and clinical outcomes when soft-tissue balancing in TKA is performed free-hand versus utilization of VERASENSE, though we hypothesize a difference in the long-term


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 628 - 633
1 May 2016
Heijens E Kornherr P Meister C

Aims. In patients undergoing medial opening wedge high tibial osteotomy (MOWHTO), soft tissue opening on the medial side of the knee is difficult to predict. When the load bearing axis is corrected beyond a certain point, the knee joint tilts open on the medial side. We therefore hypothesised that there is a tipping point and defined this as the coronal hypomochlion. Patients and Methods. In this prospective study of 150 navigated MOWHTOs (144 consecutive patients), data were collected before surgery and at three months post-operatively. In order to calculate the hypomochlion, we compared the respective changes to the joint line convergence angle (JLCA) with the post-operative axis of the leg. The change to the medial proximal tibial angle accounts for only about 80% of the change to the femorotibial angle; 20% of the correction can therefore be attributed to non-osseous, soft-tissue changes. Results. We were able to demonstrate a linear change of JLCA in a range of 0° to 5° of valgus which started when the post-operative long-leg axis was corrected beyond 2° of valgus. Conclusion. We found that the coronal hypomochlion occurs at 2° of valgus. Take home message: It is recommended to plan realignment for medial open wedge high tibial osteotomy at a maximum of 2° valgus. Cite this article: Bone Joint J 2016;98-B:628–33


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 19 - 19
1 Jul 2012
Yasen S Melton J Wilson A
Full Access

Background. The management of chondral lesions in the knee, especially in young fit patients, remains an area of considerable controversy. Articular cartilage repair or reconstruction techniques may offer these patients alternatives to arthroplasty or realignment osteotomy. The TruFit plug (Smith & Nephew, London, UK) is a synthetic biphasic polymer scaffold that is designed for implantation at the site of a focal chondral defect. It is intended to resorb and allow tissue ingrowth 6-9 months following implantation and may be placed either arthroscopically or via an open approach depending on the site of the lesion. Methods. 11 patients with focal chondral defects in the knee underwent TruFit plug implantation. Postoperative management entailed a period of 6 weeks of restricted weight bearing or restricted knee flexion according to implantation site. Radiological evaluation with MRI or CT arthrogram (or both) was conducted at various time points postoperatively according to clinical indication. Functional scoring with the Oxford knee score (OKS), Tegner activity scale and Lysholm score were completed. Results. 35 TruFit plugs were implanted in 12 knees of 11 patients (4 men, 7 women) between June 2007 and December 2009. Mean age at time of surgery 46.9 years (range32-72years). Mean change in OKS 1.33 (range -13 to 29), Lysholm 13.8 (range -19 to 61), Tegner 0.33 (range -2 to 2 levels). Imaging characteristics on MRI and CT arthrogram show delayed incorporation of the grafts in all patients with no osseous integration at up to 24 months follow up. Conclusions. Early results from the TruFit plug show variable functional outcome scores which appear independent of patient age, number of plugs used and site of implantation. All show delayed tissue integration. Our group is currently not implanting any further TruFit plugs pending longer term outcomes from larger case series


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 45 - 45
1 Mar 2012
Newman J
Full Access

Introduction. Trochlear dysplasia (TD) is still poorly recognised, generally considered uncommon and to present purely as persistent patella dislocation. Diagnosis. 87 patients diagnosed as having TD by a true lateral X-ray, MRI scan or at surgery were sent a questionnaire about their initial symptoms. 60% had suffered adolescent anterior knee pain. Lack of trust, wobbling, stair problems, giving way and catching were also common symptoms. Only 66% had ever suffered a dislocation, their troubles had started at 12 years of age. Most had undergone unsuccessful realignment procedures and many had developed premature lateral patello-femoral arthritis. Natural History. 13 cases presented with late stage disease, in which the extensor mechanism is chronically dislocated and the PFJ arthritic. These were treated by isolated PFR. In a further 5 cases end stage disease had developed. In these the chronically dislocated extensor mechanism had lead to an associate valgus knee with lateral compartment arthritis. These were treated by a TKR. Results. 16 of the 18 cases had a satisfactory result, though in two this followed secondary surgery to stabilise the extensor mechanism. Some flexion was lost but the average ROM post operatively was 110°. Two end stage cases, treated early in the series, had a persistent problem with valgus instability. Since this problem tends to occur with end stage disease subsequent similar cases were treated with a rotatating hinge, with much improved results. Conclusion. TD can present in a variety of ways. If untreated the condition can lead to symptomatic PFOA, often with complete loss of cartilage in the lateral patello femoral joint before the age of 50. In severe cases chronic extensor mechanism dislocation can result and ultimately lateral compartment arthritis may follow


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1261 - 1269
1 Jul 2021
Burger JA Zuiderbaan HA Sierevelt IN van Steenbergen L Nolte PA Pearle AD Kerkhoffs GMMJ

Aims

Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs.

Methods

A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed.


Bone & Joint Open
Vol. 1, Issue 8 | Pages 465 - 473
1 Aug 2020
Aspinall SK Wheeler PC Godsiff SP Hignett SM Fong DTP

Aims

This study aims to evaluate a new home medical stretching device called the Self Treatment Assisted Knee (STAK) tool to treat knee arthrofibrosis.

Methods

35 patients post-major knee surgery with arthrofibrosis and mean range of movement (ROM) of 68° were recruited. Both the STAK intervention and control group received standard physiotherapy for eight weeks, with the intervention group additionally using the STAK at home. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Oxford Knee Scores (OKS) were collected at all timepoints. An acceptability and home exercise questionnaire capturing adherence was recorded after each of the interventions.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 915 - 921
1 Aug 2019
Beckers L Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims

Altered alignment and biomechanics are thought to contribute to the progression of osteoarthritis (OA) in the native compartments after medial unicompartmental knee arthroplasty (UKA). The aim of this study was to evaluate the bone activity and remodelling in the lateral tibiofemoral and patellofemoral compartment after medial mobile-bearing UKA.

Patients and Methods

In total, 24 patients (nine female, 15 male) with 25 medial Oxford UKAs (13 left, 12 right) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively and at one and two years postoperatively, along with standard radiographs and clinical outcome scores. The mean patient age was 62 years (40 to 78) and the mean body mass index (BMI) was 29.7 kg/m2 (23.6 to 42.2). Mean osteoblastic activity was evaluated using a tracer localization scheme with volumes of interest (VOIs). Normalized mean tracer values were calculated as the ratio between the mean tracer activity in a VOI and background activity in the femoral diaphysis.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 204 - 210
1 Feb 2017
Xu J Jia Y Kang Q Chai Y

Aims

To present our experience of using a combination of intra-articular osteotomy and external fixation to treat different deformities of the knee.

Patients and Methods

A total of six patients with a mean age of 26.5 years (15 to 50) with an abnormal hemi-joint line convergence angle (HJLCA) and mechanical axis deviation (MAD) were included. Elevation of a tibial hemiplateau or femoral condylar advancement was performed and limb lengthening with correction of residual deformity using a circular or monolateral Ilizarov frame.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 912 - 916
1 Jul 2017
Vandeputte F Vandenneucker H

Aims

The aim of this study was to compare the outcome of revision total knee arthroplasty (TKA) with and without proximalisation of the tibial tubercle in patients with a failed primary TKA who have pseudo patella baja.

Patients and Methods

All revision TKAs, performed between January 2008 and November 2013 at a tertiary referral University Orthopaedic Department were retrospectively reviewed. Pseudo patella baja was defined using the modified Insall-Salvati and the Blackburne-Peel ratios. A proximalisation of the tibial tubercle was performed in 13 patients with pseudo patella baja who were matched with a control group of 13 patients for gender, age, height, weight, body mass index, length of surgery and Blackburne-Peel ratio. Outcome was assessed two years post-operatively using the Knee Society Score (KSS).


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 59 - 65
1 Jan 2017
Krause F Barandun A Klammer G Zderic I Gueorguiev B Schmid T

Aims

To assess the effect of high tibial and distal femoral osteotomies (HTO and DFO) on the pressure characteristics of the ankle joint.

Materials and Methods

Varus and valgus malalignment of the knee was simulated in human cadaver full-length legs. Testing included four measurements: baseline malalignment, 5° and 10° re-aligning osteotomy, and control baseline malalignment. For HTO, testing was rerun with the subtalar joint fixed. In order to represent half body weight, a 300 N force was applied onto the femoral head. Intra-articular sensors captured ankle pressure.