Advertisement for orthosearch.org.uk
Results 1 - 20 of 831
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 610 - 621
1 Jun 2023
Prodromidis AD Chloros GD Thivaios GC Sutton PM Pandit H Giannoudis PV Charalambous CP

Aims. Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening. Methods. A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken. Results. Of 263 studies, 12 were included with a total of 3,861 TKAs. Meta-analysis of ten studies showed high rates of overall tibial or femoral RLLs for the cemented original design of the ATTUNE TKA. The overall rate was 21.4% (95% confidence interval (CI) 12.7% to 33.7%) for all types of design but was higher for certain subgroups: 27.4% (95% CI 13.4% to 47.9%) for the cruciate-retaining type, and 29.9% (95% CI 15.6% to 49.6%) for the fixed-bearing type. Meta-analysis of five studies comparing the ATTUNE TKA with other implants showed a significantly higher risk of overall tibial or femoral RLLs (odds ratio (OR) 2.841 (95% CI 1.219 to 6.623); p = 0.016) for the ATTUNE. The rates of loosening or revision for loosening were lower, at 1.2% and 0.9% respectively, but the rates varied from 0% to 16.3%. The registry data did not report specifically on the original ATTUNE TKA or on revision due to loosening, but ‘all-cause’ five-year revision rates for the cemented ATTUNE varied from 2.6% to 5.9%. Conclusion. The original cemented ATTUNE TKA has high rates of RLLs, but their clinical significance is uncertain given the overall low associated rates of loosening and revision. However, in view of the high rates of RLLs and the variation in the rates of loosening and revision between studies and registries, close surveillance of patients who have undergone TKA with the original ATTUNE system is recommended. Cite this article: Bone Joint J 2023;105-B(6):610–621


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 24 - 26
1 Jan 1999
Vyskocil P Gerber C Bamert P

The radiolucent lines and the stability of the components of 66 knee arthroplasties were assessed by six orthopaedic surgeons on conventional anteroposterior and lateral radiographs and on fluoroscopic views which had been taken on the same day. The examiners were blinded as to the patients and clinical results. The interpretation of the radiographs was repeated after five months. On fluoroscopically-assisted radiographs four of the six examiners identified significantly more radiolucent lines for the femoral component (p < 0.05) and one significantly more for the tibial implant. Five examiners rated more femoral components as radiologically loose on fluoroscopically-assisted radiographs (p = 0.0008 to 0.0154), but none did so for the tibial components. The mean intra- and interobserver kappa values were higher for fluoroscopically-assisted radiographs for both components. We have shown that fluoroscopically-assisted radiographs allow more reproducible, and therefore reliable, detection of radiolucent lines in total knee arthroplasty. Assessment of the stability of the components is significantly influenced by the radiological technique used. Conventional radiographs are not adequate for evaluation of the stability of total knee arthroplasty and should be replaced by fluoroscopically-assisted films


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 38 - 38
1 Mar 2009
Torrens C Martinez-Diaz S Abad R Gelber P Caceres E
Full Access

Introduction: Prostheses radiolucent lines are currently used to evaluate the components fixation. The objective of this study is to determine concordance and reproducibility of humeral stem radiolucent lines evaluation. Material and method: Five observers evaluated 64 x-ray belonging to 32 pairs (1 antero-posterior view and 1 outlet view) obtained from 16 shoulder prostheses. 16 x-ray pairs were obtained immediately after surgery and 16 one year after surgery. Evaluation in four degrees of radiolucent width for each of the 7 zones that the humeral component was divided for. Evaluation of the component-cement interface and the cement-bone interface. Each observer made two evaluations of the 64 x-ray separated in 6 weeks. Statistics : index kappa with quadratic weighting. Results: Intra-observer results: mean kappa index for component-cement interface: 0,3274. mean kappa index for cement-bone interface: 0,5269. Inter-observer results: mean kappa index for component-cement interface: 0,1242. mean kappa index for cement-bone interface: 0,2478. Evaluation of 2 pairs of x-ray of the each prostheses taken in a period of 1 year: component-cement interface: mean of 91,67% of plausible results, cement-bone interface: mean of 80,2% of plausible Results:. Conclusions:. - low kappa index of reproducibility (0,3274–0,5269) of humeral component radiolucent lines evaluation for component-cement interface as well as for cement-bone interface. - low kappa index of concordance (0,1242–0,2478) of humeral component radiolucent lines evaluation for component-cement interface as well as for cement-bone interface. - High number of plausible observations when the same prostheses was evaluated immediately after surgery and at 1 year follow-up


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 317 - 324
1 Mar 2017
Schilcher J Palm L Ivarsson I Aspenberg P

Aims. Post-operative migration of cemented acetabular components as measured by radiostereometric analysis (RSA) has a strong predictive power for late, aseptic loosening. Also, radiolucent lines predict late loosening. Migration has been reduced by systemic bisphosphonate treatment in randomised trials of hip and knee arthroplasty. Used as a local treatment, a higher local dose of bisphosphonate can be achieved without systemic exposure. We wished to see if this principle could be applied usefully in total hip arthroplasty (THA). Patients and Methods. In this randomised placebo-controlled, double-blinded trial with 60 participants, we compressed gauze soaked in bisphosphonate solution (ibandronate) or saline against the acetabular bone bed immediately before cementing the acetabular component. RSA, classification of radiolucent lines, the Harris Hip Score (HHS) and the Western Ontario McMasters Universities Osteoarthritis Index (WOMAC) were carried out at three-, six-, 12-, and 24-month follow-up. Results. Migration of the cemented acetabular component relative to the pelvis was reduced by movement almost half in the ibandronate group, when measured as maximum total point or as movement of the femoral head (p = 0.001 and 0.004, respectively). Radiolucent lines after one year were classified as absent, partial or complete, and correlated with treatment (rho 0.37; p = 0.004). Only three of 30 patients in the ibandronate group had complete lines, compared with 13 of 28 in the placebo group (p = 0.002). There were no significant effects on HHS or WOMAC score. Conclusion. Considering the power of RSA to predict loosening of cemented acetabular components, and the likelihood that radiolucent lines indicate risk of loosening, these data suggest that local treatment with a bisphosphonate can reduce the risk of late aseptic loosening. Cite this article: Bone Joint J 2017;99-B:317–24


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1240 - 1248
1 Nov 2024
Smolle MA Keintzel M Staats K Böhler C Windhager R Koutp A Leithner A Donner S Reiner T Renkawitz T Sava M Hirschmann MT Sadoghi P

Aims. This multicentre retrospective observational study’s aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following total knee arthroplasty (TKA) between the conventional Attune baseplate and its successor, the novel Attune S+, independent from other potentially influencing factors; and whether tibial baseplate design and presence of RLLs are associated with differing risk of revision. Methods. A total of 780 patients (39% male; median age 70.7 years (IQR 62.0 to 77.2)) underwent cemented TKA using the Attune Knee System) at five centres, and with the latest radiograph available for the evaluation of RLL at between six and 36 months from surgery. Univariate and multivariate logistic regression models were performed to assess associations between patient and implant-associated factors on the presence of tibial and femoral RLLs. Differences in revision risk depending on RLLs and tibial baseplate design were investigated with the log-rank test. Results. The conventional and novel Attune baseplates were used in 349 (45%) and 431 (55%) patients, respectively. At a median follow-up of 14 months (IQR 11 to 25), RLLs were present in 29% (n = 228/777) and 15% (n = 116/776) of the tibial and femoral components, respectively, and were more common in the conventional compared to the novel baseplate. The novel baseplate was independently associated with a lower incidence of tibial and femoral RLLs (both regardless of age, sex, BMI, and time to radiograph). One- and three-year revision risk was 1% (95% CI 0.4% to 1.9%)and 6% (95% CI 2.6% to 13.2%), respectively. There was no difference between baseplate design and the presence of RLLs on the the risk of revision at short-term follow-up. Conclusion. The overall incidence of RLLs, as well as the incidence of tibial and femoral RLLs, was lower with the novel compared to the conventional tibial Attune baseplate design, but higher than in the predecessor design and other commonly used TKA systems. Cite this article: Bone Joint J 2024;106-B(11):1240–1248


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1604 - 1610
1 Oct 2021
Takaoka Y Goto K Tamura J Okuzu Y Kawai T Kuroda Y Orita K Matsuda S

Aims. We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods. We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results. The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion. The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 777 - 781
1 Jun 2011
Kalra S Smith TO Berko B Walton NP

The Oxford unicompartmental knee replacement gives good results in patients with symptomatic osteoarthritis of the medial compartment. Previous studies have suggested that the presence of radiolucent lines (RLLs) does not reflect a poor outcome in such patients. However, the reliability and validity of this assessment have not been determined. Our aim was to assess the intra- and interobserver reliability and the sensitivity and specificity of the assessment of RLLs around both tibial and femoral components using standard radiographs. Two reviewers assessed the radiographs of 45 patients who had loosening of the tibial or femoral component confirmed at revision surgery and compared them with those of a series of 45 asymptomatic patients matched for age and gender. The results suggested that, using standard radiographs, tibial RLLs were 63.6% sensitive and 94.4% specific and femoral RLLs 63.9% sensitive and 72.7% specific for loosening. Overall intra- and interobserver reliability was highly variable, but zonal analysis showed that lucency at the tip of the femoral peg was significantly associated with loosening of the femoral component. Fluoroscopically guided radiographs may improve the zonal reliability of the assessment of RLLs, but further independent and comparative studies are required. In the meantime, the innocence of the physiological RLLs detected by standard radiographs should be viewed with caution


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 48 - 48
1 Mar 2009
Schmitt S Harman M Roessing S Hodge W
Full Access

Survivorship of unicondylar knee replacement (UKR) exceeds 85% at 10 years. During long term follow-up, progressive osteoarthritis (OA) and loosening are typical of UKR failure. The decision to revise UKR is complex as radiographic findings are not always consistent with clinical symptoms. This study of revised UKR compares intraoperative assessment of component fixation and progressive OA with prerevision radiographic evaluations. Twenty-seven UKR were retrieved from 22 female and 5 male patients. Patient age and time in situ averaged 76 (68–87) years and 79 (25–156) months, respectively. At index arthroplasty, all knees received a fixed-bearing medial UKR with cement fixation. Prior to revision, radiolucent lines and component alignment were assessed on radiographs according to Knee Society guidelines. Suspected revision reasons based on clinical and radiographic evaluation included aseptic loosening (63%), progressive OA (22%), and wear (15%). During revision surgery, component fixation was manually assessed and graded as well-fixed or loose, and progressive OA was graded using Outerbridge classification. Intraoperative and radiographic assessments were completed independently. Average Knee Society Scores declined > 30 points to 53+18 (pain) and 43+11 (function) before revision. During revision surgery, femoral and tibial component fixation were graded as loose in 19 (70%) and 9 (33%) knees, respectively. There was Grade III or IV progressive OA in the lateral or patellofemoral compartment of 15 (56%) and 16 (59%) knees, respectively. Radiolucent lines were evident in 8 of 19 loose femoral components and 5 of 9 loose tibial components. In contrast, 3 of 8 well-fixed femoral components and 6 of 18 well-fixed tibial components had radiolucent lines. There were 11 loose femoral components and 4 loose tibial components without radiolucent lines. Radiographic limb alignment averaged 3°+3° valgus immediately after index UKR. Change in limb alignment ranged from 0° to 17° at revision. Tibial or femoral component alignment changed 5° to 9° in 12 (44%) knees and > 10° in 5 (19%) knees. Eight of these 17 knees (47%) had malaligned components graded as loose. The prevalence of progressive OA at revision UKR was more than double occurrence suspected from radiographs. Interpreting radiographic indications for loosening was difficult. Radiolucent lines predicted loosening in 46% (13/28) of the components graded as loose and falsely predicted loosening in 35% (9/26) of the components graded as well-fixed. Radiolucent lines were absent in 15/28 (54%) of the loose components and changes in component alignment > 5° were associated with component loosening in < 50% of the knees. Rigorous attention to clinical symptoms and careful interpretation of radiographic phenomena are needed to determine indications for revision in UKR patients


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 112 - 112
1 Feb 2017
Faizan A Chuang P Aponte C Sharkey P
Full Access

Introduction. Various 2D and 3D surfaces are available for cementless fixation of acetabular cups. The goal of these surface modifications is to improve fixation between the metallic cups and surrounding bone. Radiographs have historically been used to evaluate the implant-to-bone fixation around the acetabular cups. In general, a well fixed cup shows no gaps or radiolucency around the cup's outer diameter. In post-operative radiographs, the presence of progressive radiolucent zones of 2mm or more around the implant in the three radiographic zones is indicative of aseptic loosening, as described by DeLee and Charnley [1]. In this cadaveric study, we investigated the X-ray image characteristics of two different types of acetabular shell surfaces (2D and 3D) to evaluate the implant-to-bone interface in the two designs. Methods. Six human cadavers were bilaterally implanted with acetabular cups by an orthopaedic surgeon. 2D surface cups (Trident, Stryker, Mahwah, NJ) and 3D surface cups (Tritanium, Stryker, Mahwah, NJ) were randomized between the left and right acetabula. The surgeon used his regular surgical technique (1 mm under reaming) to implant the acetabular cups. The cadavers were sent for X-ray imaging after the operation, Figure 1A. Following the X-ray imaging, the acetabular cups were carefully resected from the cadavers. Enough bone around the cups was retained for analysis of the implant-to-bone interface by contact X-ray. The acetabular cups with the surrounding bone were fixed in 70% isopropyl alcohol for about a week and subsequently embedded in polymethyl methacrylate. The embedded cups were sectioned at 30° intervals using a diamond saw in the coronal plane, as recommended by Engh et al [2], Figure 1B. The sectioning of the samples produced 6 slices of each cup where the implant-bone interface could easily be visualized for evaluation with contact X-ray. Results. The AP X-rays of the cadavers demonstrated radiolucent lines, as well as gap defects in some cases. The same phenomenon was observed on the contact X-rays of the embedded implant sections as well, where one could easily identify the gap between the metal cup and the surrounding bone. The most striking finding was that, in a few cases, the contact X-rays showed radiolucency around the metal cup whereas the physical section did not seem to have any gaps. This phenomenon is illustrated in Figure 2. Conclusions. The physical gap or radiolucent lines around the acetabular cups have been reported in literature; however, they seem to fill up with time as biological fixation progresses between the surrounding bone and the implant. In our study we found radiolucency that was not associated with the presence of a physical gap. In contrast, we found gaps on physical sections that were not correlated with radiolucencies. This phenomenon may be attributed to the interaction of X-rays with the cup surface modifications. The contact X-ray images demonstrated that radiolucency around cups may not always correlate with physical gaps. Further analysis is required to understand the implications of these findings


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 881 - 886
1 Jul 2013
Bjorgul K Novicoff WN Andersen ST Ahlund OR Bunes A Wiig M Brevig K

A total of 397 hips were randomised to receive Metasul metal-on-metal (MoM), metal-on-conventional polyethylene (MoP) or ceramic-on-polyethylene (CoP) bearings using a cemented triple-tapered polished femoral component (MS-30). There were 129 MoM hips in 123 patients (39 male and 84 female, mean age 63.3 years (40.7 to 72.9)), 137 MoP hips in 127 patients (39 male and 88 female, mean age 62.8 years (24.5 to 72.7)) and 131 CoP hips in 124 patients (51 male and 73 female, mean age 63.9 years (30.6 to 73.8)). All acetabular components were cemented Weber polyethylene components with the appropriate inlay for the MoM articulation. Clinical evaluation was undertaken using the Harris hip score (HHS) and radiological assessments were made at two, five and seven years. The HHS and radiological analysis were available for 341 hips after seven years. The MoM group had the lowest mean HHS (p = 0.124), a higher rate of revision (p < 0.001) and a higher incidence of radiolucent lines in unrevised hips (p < 0.001). In all, 12 revisions had been performed in 12 patients: eight in the MoM group (four for infection, four for aseptic loosening, three in the MoP group (one each of infection, dislocation and pain) and one in the CoP group (infection). Our findings reveal no advantage to the MoM bearing and identified a higher revision rate and a greater incidence of radiolucent lines than with the other articulations. We recommend that patients with a 28 mm Metasul MoM bearing be followed carefully. Cite this article: Bone Joint J 2013;95-B:881–6


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 25 - 25
1 Jun 2017
Evans J Maggs J Smeatham A Charity J Timperley A
Full Access

When Radiolucent lines (RLL) are observed around cemented acetabular components, they may progress and be associated with loosening. We reviewed the incidence and progression of RLLs around the Exeter Contemporary flanged acetabular component and compared our results with other published series. We reviewed a consecutive series of 203 sockets with a minimum 10-year follow-up. Up to date radiographs were reviewed by 2 independent assessors for the presence, location and thickness of RLL and an assessment for loosening/migration was made. Initial post-operative radiographs were examined for any case with RLLs at review. There were no revisions for aseptic loosening. 103 hips remained in situ with a minimum follow up of 10 years. Lucent lines were seen on 37/103 (36%) of hips with a mean follow up of 12.1 years (10.0–13.9 years). In these 37 hips, the lucency was present in one zone in 84%, two zones in 8% and all three zones in 8%. Of the 37 hips with a RLL at minimum 10 years follow up, five exhibited a RLL immediately post-operatively. All 5 of these lines were initially isolated to zone 1 and progressed over the 10 years around at least 1 more zone. Only one line became circumferential, although the cup did not migrate. Compared to previous papers (DeLee & Charnley, Hodgkinson and Garcia-Cimbrelo) the presence of RLL at 10 years is reduced in our series (table 2) and no cup migrated. All RLL seen in cups at both 10 years and immediate post-operatively in our series progressed (table 3), unlike in the previous studies. This reduction in lucent lines may be down to modern cementing techniques, cup design or a combination of both. For any figures or tables, please contact the authors directly by clicking on ‘Info & Metrics’ above to access author contact details


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 550 - 555
1 May 2002
Iwaki H Scott G Freeman MAR

We studied 185 total hip replacements and related the identification of radiolucent lines (RLLs) at two years to the later development of lytic lesions and loosening. Linear polyethylene wear was also measured. RLLs appeared in 34 hips at a mean of 2.0 years after operation, and lytic lesions in ten hips at 5.7 years. Of 151 THRs without RLLs there was neither rapid migration nor loosening and only one developed a possible lytic lesion. Of 23 hips with non-progressive RLLs there was neither rapid migration nor loosening, but six developed a lytic lesion. By contrast, 11 THRs with progressive RLLs migrated rapidly and seven developed a lytic lesion. Six THRs with progressive RLLs failed. The wear rates were the same in all groups, although limited numbers were available for study. If the surgeon achieves secure initial fixation as shown by slow or no migration and no RLLs during the first two years, it is likely that no lytic lesions will develop by five years or aseptic loosening by ten years. If an imperfect, but adequate, interface is achieved, as shown by slow migration and non-progressive RLLs lytic lesions adjacent to the RLLs may develop by five years, but aseptic loosening will be unlikely at ten. Insecure initial fixation, as shown by more rapid migration and progressive RLLs at two years, is likely to lead to the formation of lytic lesions at five years and loosening at ten. The outcome after THR is therefore determined at the initial operation and may be predicted at two years. The presence of lytic lesions reflects soft tissue at the interface as shown by the RLLs which accompany and promote loosening but, in our study, did not cause it


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 31 - 31
1 May 2016
Maruyama M Shimodaira H
Full Access

OBJECTIVE OF THE STUDY. The objective of this study is to establish the medium-term clinical and radiological results with the cementless three-dimensional Vektor-Titan stem compared with conventional cementless stem, such as PerFix stem. The latter stem has a double-wedge design with a rounded distal portion for canal filling (Fig. 1). MATERIALS AND METHODS. From July, 2004, to May, 2010, fifty seven Vektor-Titan stems and 150 PerFix stems were implanted for the patients with osteoarthritis, avascular necrosis, femoral neck fracture, and rheumatoid arthritis in our hospital. The results were evaluated clinically using Japanese Orthopedic Association (JOA) scores and the Merle d’Aubigne and Postel (M&P) scores. Radiographs were analyzed retrospectively. The criteria used for determining loosening were migration or a total radiolucent zone between the prosthesis/bone cement and host bone, wherein the width increased progressively or change of position, i.e., migration or subsidence of the prosthesis. Migration of the socket seen on the radiograph was defined as either the presence of a ≥2-mm position change or rotation. Position changes of the stem seen on the radiograph were defined as the presence of a progressive subsidence of ≥2 mm or change of position, e.g., varus or valgus. The follow-up period was 9.2 ± 2.6 (range, 5.0–14.0) years. RESULTS. One patient had intraoperative femoral shaft fracture and healed by conservative treatment. The mean JOA and M&P scores improved from preoperative 39.3 and 6.8 points to postoperative 90.9 and 17.2 points, respectively. Thigh pain was less frequent for Vektor-Titan stems (Table 1). Radiolucent lines was far less likely to appear for Vektor-Titan stems evaluated by Gruen's zonal analyses (Table 2). On the other hand, there were radiolucent zones of more than 90% in zone 4 with cementless PerFix stems (Table 2). There was no cases of loosening or postoperative infection. Although signs of bone atrophy were found in the proximal femur and the trochanters in 66.7 % of all cases, bone structure was radiologically normal without stress shielding in most cases (Table 2). On the contrary, there was evidence of an even denser bone structure, such as trabeculae, at the tip of the stem and the lateral implant fixation within the greater trochanter in Vektor-Titan stem cases. These findings remained unchanged over observation periods. DISCUSSION AND CONCLUSIONS. The cementless Vektor-Titan stem is made of Ti6AI7Nb, has got the shape of a straight three-dimensional cone. It has a high proximal volume in the form of a three-dimensional taper with longitudinal ribs. This design achieves strong primary fixation in the proximal metaphysis. Radiologically, newly formed trabeculae toward to the stem were indicative of direct biological fixation at the bone-implant interface. Medium-term results with the cementless Vektor-Titan stem show no implant loosening with stable metaphyseal fixation and preservation of bone structure in the proximal femur and the absence of radiolucent zones around the stem compared with conventional cementless stem


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 40 - 40
1 Jul 2022
Prodromidis A Chloros G Thivaios G Sutton P Veysi V Giannoudis P Charalambous C
Full Access

Abstract

Introduction

Higher than expected rates of tibial loosening with the ATTUNE® total knee arthroplasty (TKA) implant has been reported. Component loosening can be associated with the development of radiolucency lines (RLL) and our study aim was to systematically assess the reported rates of these.

Methodology

A systematic search was undertaken using the Cochrane methodology in four online databases. Identified studies were assessed and screened against predetermined inclusion criteria. Meta-analysis was conducted using a random-effects model.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 320 - 320
1 Mar 1992
Hardy


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 122 - 122
1 Mar 2017
Roche C Greene A Wright T Flurin P Zuckerman J Grey S
Full Access

Introduction. The clinical impact of radiolucent glenoid lines is controversial, where the presence of a radiolucent glenoid lines has been suggested to be an indicator of clinical glenoid loosening. The goal of this database analysis is to quantify and compare the pre- and post-operative outcomes of 427 patients who received a primary aTSA with one specific prosthesis and were sorted based upon the radiographic presence of a radiolucent glenoid line at latest clinical followup. Methods. 427 patients (mean age: 67.0yrs) with an average follow-up of 49.4 months was treated with aTSA for OA by 14 fellowship trained orthopaedic surgeons. Of these 427 patients, 293 had a cemented keel glenoids (avg follow-up = 50.8 months) and 134 had a cemented pegged glenoids (avg follow-up = 48.7 months). Cemented peg and keel glenoid patients were analyzed separately and also combined into 1 cohort: 288 patients (158 female, avg: 68.7 yrs; 130 male, avg: 64.9 yrs) did not have a radiolucent glenoid line (avg follow-up = 46.9 months); whereas, 139 patients (83 female, avg: 68.5 yrs; 56 male, avg: 64.6 yrs) had a radiolucent glenoid line (avg follow-up = 54.4 months). Outcomes were scored using SST, UCLA, ASES, Constant, and SPADI metrics; active ROM also measured. A two-tailed, unpaired t-test identified differences (p<0.05) in pre-operative, post-operative, and pre-to-post improvements. Results. The overall rate of radiolucent line formation in the glenoid for the combined peg and keel glenoid aTSA cohort was 32.6% (139 of 427 patients). The rate of radiolucent lines for the keel and peg glenoids was similar at nearly the same followup (∼50 months): 96 of 293 peg patients (32.8%) and 43 of 134 keel patients (32.1%) had a radiolucent glenoid line. Patients with cemented keeled glenoids had an average radiographic line score of 2.4 ± 1.3 which trended larger (p = 0.0875) than the average radiographic line score of 2.0 ± 1.1 of patients with cemented peg glenoids. Pre-operatively, no difference was noted between patients with and without radiolucent glenoid lines. (Figure 1) However post-operatively, patients with radiolucent glenoid lines were associated with significantly poorer clinical outcome scores according to all 5 clinical metrics and also had significantly less improvements in outcomes according to 4 of 5 outcome metrics; (Figure 2) poorer outcomes were observed for the combined cemented keeled and pegged glenoid cohorts and when each glenoid prosthesis type is analyzed separately. Additionally, patients with glenoid radiolucent lines were associated with significantly lower improvements in outcomes. (Figure 3) Finally, 24 complications were reported (5.6%), 14 for patients without radiolucent glenoid lines (4.9%) and 10 for patients with radiolucent glenoid lines (7.2%). Conclusions. This large-scale clinical outcome study demonstrated that aTSA patients with radiolucent glenoid lines were associated with significantly poorer clinical outcomes and a higher complication rate as compared to aTSA patients without radiolucent glenoid lines. The overall radiolucent line rate and the negative impact of radiolucent lines were no different between cemented keeled and cemented pegged glenoid components. Additional and longer-term follow-up is needed to confirm these conclusions. For figures/tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 123 - 123
1 Mar 2017
Roche C Greene A Flurin P Wright T Zuckerman J Jones R
Full Access

Introduction. Humeral radiolucent lines after anatomic TSA (aTSA) have been well described; however, little clinical consequences have been attributed to them. The recent emergence of shorter humeral stems has demonstrated higher incidences of humeral radiolucencies than has been reported historically with standard length components. This large scale database analysis quantifies and compares the clinical outcomes of aTSAs with and without radiolucent humeral lines using one specific prosthesis to determine their impact on clinical outcomes. Methodology. This is a multicenter, retrospective, case controlled radiographic and clinical review. Preoperative and postoperative data was analyzed from 671 aTSA patients with a minimum of 2 years followup. 538 of these 671 aTSA patients had full radiographic followup (80.2%) and were included in this study; these patients had an average followup of 45.3 months). 459 patients had noncemented humeral stems; whereas, 79 patients had cemented humeral stems. Radiographs were reviewed at latest follow up for humeral radiolucent lines based on the technique described by Gruen et al. Patients were evaluated and scored pre-operatively and at latest follow-up using the SST, UCLA, ASES, Constant, and SPADI scoring metrics; ROM was also recorded. A Student's two-tailed, unpaired t-test was used to identify differences in pre-operative, post-operative, and improvement in results, where p<0.05 denoted a significant difference. Results. All patients demonstrated significant improvements in pain and function following treatment with the primary shoulder arthroplasty. 14 patients (8 female, avg: 65.6 yrs; 6 male, avg: 61.7 yrs) were observed to have radiolucent lines around the humeral component (2.6%). The rate of humeral radiolucent lines was observed to be significantly higher in patients with cemented (7.6%) vs. noncemented (1.7%) humeral stems (p = 0.0025). Pre-operatively, no difference was noted in any clinical metric score between patients with or without radiolucent humeral lines. (Figure 1) However post-operatively, patients with radiolucent humeral lines had significantly worse ASES (p=0.0087), UCLA (p=0.0371), SST (p=0.0341), and SPADI (p=0.0051) scores (Figure 2) and significantly lower improvements in outcomes according to ASES (p=0.0120) and SPADI (p=0.0247) scores (Figure 3), relative to patients without radiolucent humeral lines. Additionally, radiolucent lines had a more profound effect on cemented stems (as compared to noncemented stems), where cemented stems with radiolucent humeral liners were associated with significantly lower post-operative outcomes and significantly lower improvements in outcomes. Finally, patients with humeral radiolucent lines had a significantly higher complication rate (21.4% vs 4.6%, p = 0.004) as compared to the complication rate of patients without radiolucent humeral lines. Conclusions. The study demonstrated a relatively low incidence of humeral radiolucent lines with anatomic TSA. Cemented stems were associated with a significantly higher rate of humeral radiolucent lines as compared to noncemented stems. Patients whose shoulders had radiolucent humeral lines were associated with significantly lower clinical outcomes and significantly less active ROM as compared to those without radiolucent lines. This diminished outcome was more pronounced with cemented humeral stems. Additional and longer term clinical followup is necessary to confirm the results of this study


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 313 - 319
1 Mar 2016
Baker P Rankin K Naisby S Agni N Brewster N Holland J

Aims

The highly cross-linked polyethylene Exeter RimFit flanged cemented acetabular component was introduced in the United Kingdom in 2010. This study aimed to examine the rates of emergence of radiolucent lines observed when the Rimfit acetabular component was implanted at total hip arthroplasty (THA) using two different techniques: firstly, the ‘rimcutter’ technique in which the flange sits on a pre-prepared acetabular rim; and secondly, the ‘trimmed flange’ technique in which the flange is trimmed and the acetabular component is seated inside the rim of the acetabulum.

Patients and Methods

The radiographs of 150 THAs (75 ‘rimcutter’, 75 ‘trimmed flange’) involving this component were evaluated to assess for radiolucencies at the cement/bone interface by three observers.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 257 - 257
1 May 2006
Guha AR Debnath UK Graham NM
Full Access

Introduction: Early non progressive horizontal RLLs (< 2mm) under the tibial component following cemented TKR have been noted to be due to poor cement injection into cancellous bone. They may facilitate the entry of joint fluid and wear debris into the interface, which may proceed to ballooning osteolysis. At present, there is no consensus on the preferred cementing technique (single mix versus dual mix cementation) in TKR.

Purposes of the study: To assess RLLs in immediate postoperative radiographs in cemented TKRs at the cement-bone and cement-implant interface.

To compare the RLLs following single mix and dual mix cementation techniques.

Study Design: Prospective, consecutive radiographic analysis.

Material and Methods: 53 consecutive cemented TKRs in 39 patients (12: 27, F: M) with mean age of 72.5 years (range 50–90 y) who were operated on between 2001 to 2004 by the senior author (NMG). 27 had single mix and 26 had double mix cementation. Immediate postoperative radiographic assessment (AP and LAT standing view) was blinded for single mix versus dual mix cementation. All the radiographs were independently assessed by two of the authors for the presence of RLLs using the zonal pattern of the Knee Society scoring system. We have evaluated the RLLs in the cement-implant interface in a similar manner as described for the bone-cement interface.

Results: Most common TKR used was the Maxim (31) followed by the PFC (9). 29(54.7%) TKRs had RLLs (11in single mix : 18 in dual mix). There were more RLLs at the Cement-implant interface (29), than the bone-cement interface (10). In AP view, Zones 1(medial) and 4 (lateral) were the common sites for RLLs in both groups (< 2mm). In Lateral view, Zone 1 (Anterior) followed by Zone 2 (Posterior) were the common sites of RLLs (< 2mm). In AP view, there was no significant difference in the number of RLLs (Zone 4) between the two groups. The total number of RLLs in all zones (Zone 1–4) was significantly low in the single mix group (p< 0.05). There was no difference between the two groups in the lateral view.

Conclusions: Single mix cementation technique reduces the incidence of RLLs in the immediate postoperative radiographs following cemented TKRs.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 971 - 976
5 Nov 2024
Baker G Hill J O'Neill F McChesney J Stevenson M Beverland D

Aims. In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. Methods. A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone. Results. The all-cause revision rate at six years was 3.1% (eight THAs), increasing to 8.8% (18 THAs) at ten years. Of these, there were four and then seven bearing-related revisions at six and ten years, respectively. There was a statistically significant deterioration in the visual analogue scale pain score and Oxford Hip Score (OHS) between six and ten years. There were 18 CoM THAs in 17 patients who had a cobalt or chromium level over 4 ppb and ten CoM THAs in nine patients who had a cobalt or chromium level higher than 7 ppb with a statistically significant increase in chromium levels only between the two timepoints. Overall, 84 stems (39.1%) had significant radiolucent lines at ten years compared to 65 (25.5%) at six years. Conclusion. When compared to the original review, there has been a significant deterioration in pain score, OHS, radiograph appearance, and, most critically, survival has fallen to 91.2%, which does not meet the Orthopaedic Data Evaluation Panel (ODEP) 10 A* 95% threshold. Although this bearing is no longer on the market, 2.5% were bearing-related revisions, which have relevance to the discussion around modular dual-mobility implants that have a similar metal interface