Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1158 - 1164
1 Oct 2024
Jakobi T Krieg I Gramlich Y Sauter M Schnetz M Hoffmann R Klug A

Aims. The aim of this study was to evaluate the outcome of complex radial head fractures at mid-term follow-up, and determine whether open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA) should be recommended for surgical treatment. Methods. Patients who underwent surgery for complex radial head fractures (Mason type III, ≥ three fragments) were divided into two groups (ORIF and RHA) and propensity score matching was used to individually match patients based on patient characteristics. Ultimately, 84 patients were included in this study. After a mean follow-up of 4.1 years (2.0 to 9.5), patients were invited for clinical and radiological assessment. The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score were evaluated. Results. Patients treated with ORIF showed significantly better postoperative range of motion for flexion and extension (121.1° (SD 16.4°) vs 108.1° (SD 25.8°); p = 0.018). Postoperative functional scores also showed significantly better results in the ORIF group (MEPS 90.1 (SD 13.6) vs 78 (SD 20.5); p = 0.004). There was no significant difference between the groups in terms of the complication rate (RHA 23.8% (n = 10) vs ORIF 26.2% (n = 11)). Implant-related complications occurred in six cases (14.3%) in the RHA group and in five cases (11.9%) in the ORIF group. Conclusion. Irrespective of the patient’s age, sex, type of injury, or number of fracture fragments, ORIF of the radial head should be attempted initially, if a stable reconstruction can be achieved, as it seems to provide a superior postoperative outcome for the patient compared to primary RHA. If reconstruction is not feasible, RHA is still a viable alternative. In the surgical treatment of complex radial head fractures, reconstruction shows superior postoperative outcomes compared to RHA. Good postoperative results can be achieved even after failed reconstruction and conversion to secondary RHA. Therefore, we encourage surgeons to favour reconstruction of complex radial head fractures, regardless of injury type or number of fragments, as long as a stable fixation can be achieved. Cite this article: Bone Joint J 2024;106-B(10):1158–1164


Bone & Joint 360
Vol. 10, Issue 5 | Pages 7 - 10
1 Oct 2021
Morris DLJ Cresswell T Espag M Tambe AA Clark DI Ollivere BJ


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 530 - 535
1 Mar 2021
Giannicola G Castagna V Villani C Gumina S Scacchi M

Aims. It has been hypothesized that proximal radial neck resorption (PRNR) following press-fit radial head arthroplasty (RHA) is due to stress-shielding. We compared two different press-fit stems by means of radiographs to investigate whether the shape and size of the stems are correlated with the degree of PRNR. Methods. The radiographs of 52 RHAs were analyzed both at 14 days postoperatively and after two years. A cylindrical stem and a conical stem were implanted in 22 patients (group 1) and 30 patients (group 2), respectively. The PRNR was measured in the four quadrants of the radial neck and the degree of stem filling was calculated by analyzing the ratio between the prosthetic stem diameter (PSD) and the medullary canal diameter (MCD) at the proximal portion of the stem (level A), halfway along the stem length (level B), and distally at the stem tip (level C). Results. Overall, 50 of the 52 patients displayed PRNR. The mean PRNR observed was 3.9 mm (0 to 7.4). The degree of endomedullary stem filling at levels A, B, and C was 96%, 90%, and 68% in group 1, and 96%, 72%, and 57%, in group 2, with differences being significant at levels B (p < 0.001) and C (p < 0.001). No significant correlations emerged between the severity of PRNR and the three stem/canal ratios either within each group or between the groups. Conclusion. PRNR in press-fit RHA appears to be independent of the shape and size of the stems. Other causes besides stem design should be investigated to explain completely this phenomenon. Cite this article: Bone Joint J 2021;103-B(3):530–535


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1620 - 1628
1 Dec 2020
Klug A Nagy A Gramlich Y Hoffmann R

Aims. To evaluate the outcomes of terrible triad injuries (TTIs) in mid-term follow-up and determine whether surgical treatment of the radial head influences clinical and radiological outcomes. Methods. Follow-up assessment of 88 patients with TTI (48 women, 40 men; mean age 57 years (18 to 82)) was performed after a mean of 4.5 years (2.0 to 9.4). The Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), and Disabilities of the Arm, Shoulder and Hand (DASH) score were evaluated. Radiographs of all patients were analyzed. Fracture types included 13 Mason type I, 16 type II, and 59 type III. Surgical treatment consisted of open reduction and internal fixation (ORIF) in all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) was performed if reconstruction was not possible. Results. At follow-up the mean MEPS was 87.1 (20 to 100); mean OES, 36.9 (6 to 48); and mean DASH score, 18.6 (0 to 90). Mean movement was 118° (30° to 150°) for extension to flexion and 162° (90° to 180°) for pronation to supination. The overall reoperation rate was 24%, with nine ORIF, ten RHA, and two patients without treatment to the radial head needing surgical revision. When treated with RHA, Mason type III fractures exhibited significantly inferior outcomes. Suboptimal results were also identified in patients with degenerative or heterotopic changes on their latest radiograph. In contrast, more favourable outcomes were detected in patients with successful radial head reconstruction after Mason type III fractures. Conclusion. Using a standardized protocol, sufficient elbow stability and good outcomes can be achieved in most TTIs. Although some bias in treatment allocation, with more severe injuries assigned to RHA, cannot be completely omitted, treatment of radial head fractures may have an independent effect on outcome, as patients subjected to RHA showed significantly inferior results compared to those subjected to reconstruction, in terms of elbow function, incidence of arthrosis, and postoperative complications. As RHA showed no apparent advantage in Mason type III injuries between the two treatment groups, we recommend reconstruction, providing stable fixation can be achieved. Cite this article: Bone Joint J 2020;102-B(12):1620–1628


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1561 - 1570
1 Dec 2017
Laumonerie P Reina N Kerezoudis P Declaux S Tibbo ME Bonnevialle N Mansat P

Aims. The primary aim of this study was to define the standard minimum follow-up required to produce a reliable estimate of the rate of re-operation after radial head arthroplasty (RHA). The secondary objective was to define the leading reasons for re-operation. Materials and Methods. Four electronic databases, between January 2000 and March 2017 were searched. Articles reporting reasons for re-operation (Group I) and results (Group II) after RHA were included. In Group I, a meta-analysis was performed to obtain the standard minimum follow-up, the mean time to re-operation and the reason for failure. In Group II, the minimum follow-up for each study was compared with the standard minimum follow-up. Results. A total of 40 studies were analysed: three were Group I and included 80 implants and 37 were Group II and included 1192 implants. In Group I, the mean time to re-operation was 1.37 years (0 to 11.25), the standard minimum follow-up was 3.25 years; painful loosening was the main indication for re-operation. In Group II, 33 Group II articles (89.2%) reported a minimum follow-up of < 3.25 years. Conclusion. The literature does not provide a reliable estimate of the rate of re-operation after RHA. The reproducibility of results would be improved by using a minimum follow-up of three years combined with a consensus of the definition of the reasons for failure after RHA. Cite this article: Bone Joint J 2017;99-B:1561–70


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1197 - 1203
1 Sep 2017
Laumonerie P Reina N Ancelin D Delclaux S Tibbo ME Bonnevialle N Mansat P

Aims. Radial head arthroplasty (RHA) may be used in the treatment of non-reconstructable radial head fractures. The aim of this study was to evaluate the mid-term clinical and radiographic results of RHA. Patients and Methods. Between 2002 and 2014, 77 RHAs were implanted in 54 men and 23 women with either acute injuries (54) or with traumatic sequelae (23) of a fracture of the radial head. Four designs of RHA were used, including the Guepar (Small Bone Innovations (SBi)/Stryker; 36), Evolutive (Aston Medical; 24), rHead RECON (SBi/Stryker; ten) or rHead STANDARD (SBi/Stryker; 7) prostheses. The mean follow-up was 74.0 months (standard deviation (. sd. ) 38.6; 24 to 141). The indication for further surgery, range of movement, mean Mayo Elbow Performance (MEP) score, quick Disabilities of the Arm, Shoulder and Hand (quickDASH) score, osteolysis and positioning of the implant were also assessed according to the design, and acute or delayed use. Results. The mean MEP and quickDASH scores were 90.2 (. sd. 14; 45 to 100), and 14.0 points (. sd. 12; 1.2 to 52.5), respectively. There were no significant differences between RHA performed in acute or delayed fashion. There were 30 re-operations (19 with, and 11 without removal of the implant) during the first three post-operative years. Painful loosening was the primary indication for removal in 14 patients. Short-stemmed prostheses (16 mm to 22 mm in length) were also associated with an increased risk of painful loosening (odds ratio 3.54 (1.02 to 12.2), p = 0.045). Radiocapitellar instability was the primary indication for re-operation with retention of the implant (5). The overall survival of the RHA, free from re-operation, was 60.8% (. sd. 5.7%) at ten years. Conclusion. Bipolar and press-fit RHA gives unsatisfactory mid-term outcomes in the treatment of acute fractures of the radial head or their sequelae. The outcome may vary according to the design of the implant. The rate of re-operation during the first three years is predictive of the long-term survival in tight-fitting RHAs. Cite this article: Bone Joint J 2017;99-B1197–1203


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 106 - 107
1 Mar 2008
Beingessner D Dunning C Stacpoole R Johnson J King G
Full Access

Passive and active elbow flexion was performed in eight cadaveric arms to determine the effect of Type 1 coronoid fractures and suture repair on kinematics. Testing was performed in ligamentously intact and MCL deficient elbows; with radial head arthroplasty (RHA); with an intact coronoid, following a Type 1 fracture, and with suture repair of the coronoid. There was an alteration in elbow kinematics and stability following Type 1 coronoid fractures that was not corrected with coronoid repair. Suture fixation of the coronoid is probably unnecessary if the lateral ligaments are repaired and the radial head is repaired or replaced. To determine the effect of fixation of Type 1 coronoid fractures on elbow stability and kinematics in ligamentously intact and medial collateral ligament (MCL) deficient elbows with radial head arthroplasty (RHA). Type 1 coronoid fractures cause changes in elbow kinematics and stability that are not corrected with suture repair. Suture fixation of Type 1 coronoid fractures is probably unnecessary if the lateral ligaments are repaired and the radial head is repaired or replaced. With intact ligaments, there was an increase in valgus angulation following a Type 1 coronoid fracture (p< 0.05) that was not corrected with fixation. With MCL deficiency, there was no change in valgus angulation for all coronoid states. For both ligament states, there was an increase maximum varus-valgus laxity after a Type 1 coronoid fracture with forearm pronation (p=0.03) that was not corrected with fixation (p=0.4). Kinematic data was collected from eight cadaveric arms during passive and simulated active elbow motion. The protocol was performed in stable and MCL deficient elbows with RHA. Testing occurred with the coronoid intact, following Type 1 coronoid fracture, and with suture repair of the fracture. Valgus angulation and maximum varus-valgus laxity were measured. With intact ligaments, Type 1 coronoid fractures cause an alteration in elbow kinematics and laxity that is not corrected with suture fixation. With MCL disruption, Type 1 coronoid fractures have no effect on elbow kinematics and a small effect on laxity that is not corrected with coronoid repair. Funding: Research and Institutional Support received from Wright Medical Technologies. Please contact author for graphs and/or diagrams


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1512 - 1519
1 Dec 2019
Klug A Konrad F Gramlich Y Hoffmann R Schmidt-Horlohé K

Aims. The aim of this study was to evaluate the outcome of Monteggia-like lesions at midterm follow-up and to determine whether the surgical treatment of the radial head influences the clinical and radiological results. Patients and Methods. A total of 78 patients with a Monteggia-like lesion, including 44 women and 34 men with a mean age of 54.7 years (19 to 80), were available for assessment after a mean 4.6 years (2 to 9.2). The outcome was assessed using the Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES), Mayo Modified Wrist Score (MMWS), and The Disabilities of the Arm, Shoulder and Hand (DASH) score. Radiographs were analyzed for all patients. A total of 12 Mason type I, 16 type II, and 36 type III fractures were included. Surgical treatment consisted of screw fixation for all type II and reconstructable type III fractures, while radial head arthroplasty (RHA) or excision was performed if reconstruction was not possible. Results. The mean MEPS was 88.9 (40 to 100), mean OES was 40.1 (25 to 48), mean MMWS was 88.1 (50 to 100), mean DASH score was 14.7 (0 to 60.2), and mean movement was 114° (. sd. 27) in extension/flexion and 155° (. sd. 37) in pronation/supination. Mason III fractures, particularly those with an associated coronoid fracture treated with RHA, had a significantly poorer outcome. Suboptimal results were also identified in patients who had degenerative changes or heterotopic ossification on their latest radiograph. In contrast, all patients with successful radial head reconstruction or excision had a good outcome. Conclusion. Good outcomes can be achieved in Monteggia-like lesions with Mason II and III fractures, when reconstruction is possible. Otherwise, RHA is a reliable option with satisfactory outcomes, especially in patients with ligamenteous instability. Whether the radial head should be excised remains debatable, although good results were achieved in patients with ligamentous stability and in those with complications after RHA. Cite this article: Bone Joint J 2019;101-B:1512–1519


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 88 - 88
1 Feb 2017
Levy J Formaini N Kurowicki J
Full Access

Background. Radial head arthroplasty (RHA) is a popular method of treatment for complex fractures of the radial head. The purpose of this study was to investigate patient outcomes and radiographic findings associated with a single anatomical monopolar press-fit radial head system commonly used for the treatment of radial head fractures. Methods. A retrospective review of prospectively collected data was performed for a consecutive series of patients treated with RHA between November 2007 and April 2014. Patients with a minimum of 12-month follow-up were included. Most recent radiographs were evaluated for loosening, stress shielding, and instability. Post-operative motion and outcomes were reported at most-recent follow-up. Results. At an average follow-up of 30 months, 7 of the 17 patients (41%) demonstrated radiographic loosening. Six of the 10 patients (60%) without loosening demonstrated stress shielding (average 6mm). Functional outcome scores included a mean ASES of 74, MEPS of 87, VAS Pain of 1, VAS Function of 8 and SANE of 79. Average flexion-extension arc was 13°–138°, and average pronation-supination was 77°–76° (Figure 1). Of the patients with radiographic loosening, 86% had undergone RHA with an associated ligamentous injury of the elbow. Satisfaction among patients was high, as no patient reported an unsatisfactory outcome. Conclusions. The use of an anatomic, press-fit monopolar RHA in the management of acute complex radial head fractures has yielded excellent clinical outcomes despite high rates of radiographic loosening and stress shielding. Press-fit RHA in the setting of ligamentous injury warrants further investigation due to a high rate of implant loosening observed


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 139 - 140
1 Mar 2008
Shore B Faber K King G Patterson S
Full Access

Purpose: Metal radial head arthroplasty is a proven technique for the treatment of complex radial head fractures. Little previous research is available on the utility and longevity of metal radial head arthroplasty for elbow reconstruction. The purpose of this study was to evaluate the functional outcome of patients with metal radial head arthroplasty (RHA) for elbow reconstruction. Methods: This was a retrospective review from one institution with three senior orthopaedic surgeons. 23 consecutive patients with 23 RHA were included in the study, 4 patients were lost to follow up. RHA was performed for conditions of rheumatoid arthritis, post traumatic radial head nonunion, post traumatic radial head malunion, elbow instability following previous radial head excision and failed silicone radial head implants. Patients were excluded from the study if they were treated for an acute injury with RHA (under 2 months from injury). There were 8 males and 15 females with a minimum of 2 year follow up. Analysis included chart review, personal interview, physical examination, radiographs and strength testing. Region specific questionnaires were used including: DASH, ASES, MEPI, PRWE, WOS and SF-36. Mean follow up was 9 yrs. Results: Mayo elbow performance scores were excellent in 11 patients, good in 4 patients, fair in 4 patients and poor in 4 patients. Subjective patient satisfaction was averaged at 8.4 out of 10. Patients demonstrated significantly less isometric strength and grip strength in the affected versed unaffected elbow. There was no statistically significant difference seen in ulnar variance or ulnohumeral joint space between the affected and unaffected limbs. Conclusions: In conclusion, RHA for elbow reconstruction is a safe procedure that provides patients with long term functional ROM and pain relief


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1165 - 1175
1 Oct 2024
Frost Teilmann J Petersen ET Thillemann TM Hemmingsen CK Olsen Kipp J Falstie-Jensen T Stilling M

Aims

The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).

Methods

Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 905 - 911
1 Aug 2023
Giannicola G Amura A Sessa P Prigent S Cinotti G

Aims

The aim of this study was to analyze how proximal radial neck resorption (PRNR) starts and progresses radiologically in two types of press-fit radial head arthroplasties (RHAs), and to investigate its clinical relevance.

Methods

A total of 97 patients with RHA were analyzed: 56 received a bipolar RHA (Group 1) while 41 received an anatomical implant (Group 2). Radiographs were performed postoperatively and after three, six, nine, and 12 weeks, six, nine, 12, 18, and 24 months, and annually thereafter. PRNR was measured in all radiographs in the four radial neck quadrants. The Mayo Elbow Performance Score (MEPS), the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH), and the patient-assessed American Shoulder and Elbow Surgeons score - Elbow (pASES-E) were used for the clinical assessment. Radiological signs of implant loosening were investigated.