Advertisement for orthosearch.org.uk
Results 1 - 20 of 246
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 183 - 188
1 Jan 2022
van Sloten M Gómez-Junyent J Ferry T Rossi N Petersdorf S Lange J Corona P Araújo Abreu M Borens O Zlatian O Soundarrajan D Rajasekaran S Wouthuyzen-Bakker M

Aims. The aim of this study was to analyze the prevalence of culture-negative periprosthetic joint infections (PJIs) when adequate methods of culture are used, and to evaluate the outcome in patients who were treated with antibiotics for a culture-negative PJI compared with those in whom antibiotics were withheld. Methods. A multicentre observational study was undertaken: 1,553 acute and 1,556 chronic PJIs, diagnosed between 2013 and 2018, were retrospectively analyzed. Culture-negative PJIs were diagnosed according to the Muskuloskeletal Infection Society (MSIS), International Consensus Meeting (ICM), and European Bone and Joint Society (EBJIS) definitions. The primary outcome was recurrent infection, and the secondary outcome was removal of the prosthetic components for any indication, both during a follow-up period of two years. Results. None of the acute PJIs and 70 of the chronic PJIs (4.7%) were culture-negative; a total of 36 culture-negative PJIs (51%) were treated with antibiotics, particularly those with histological signs of infection. After two years of follow-up, no recurrent infections occurred in patients in whom antibiotics were withheld. The requirement for removal of the components for any indication during follow-up was not significantly different in those who received antibiotics compared with those in whom antibiotics were withheld (7.1% vs 2.9%; p = 0.431). Conclusion. When adequate methods of culture are used, the incidence of culture-negative PJIs is low. In patients with culture-negative PJI, antibiotic treatment can probably be withheld if there are no histological signs of infection. In all other patients, diagnostic efforts should be made to identify the causative microorganism by means of serology or molecular techniques. Cite this article: Bone Joint J 2022;104-B(1):183–188


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 34 - 44
1 Jan 2022
Beckers L Dandois F Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims. Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs. Methods. In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m. 2. (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research. Results. Significant reduction of tracer activity from the preoperative situation was found in femoral and anteromedial tibial VOIs adjacent to the UKA components. Temporarily increased osteoblastic bone activity was observed in VOIs comprising the UKA keel structure at one year postoperatively compared to the preoperative activity. Persistent higher tracer uptake was found in the posterior tibial cortex at final follow-up. Multivariate analysis showed no statistical difference in osteoblastic bone activity underneath cemented or cementless components. Conclusion. Well-functioning medial mobile-bearing UKAs showed distinct changes in patterns of normalized bone tracer activity in the different VOIs adjacent to the prosthetic components, regardless of their type of fixation. Compared to the preoperative situation, persistent high bone activity was found underneath the keel and the posterior tibial cortex at final follow-up, with significant reduced activity only being identified in femoral and anteromedial tibial VOIs. Cite this article: Bone Joint J 2022;104-B(1):34–44


Bone & Joint Research
Vol. 13, Issue 6 | Pages 306 - 314
19 Jun 2024
Wu B Su J Zhang Z Zeng J Fang X Li W Zhang W Huang Z

Aims

To explore the clinical efficacy of using two different types of articulating spacers in two-stage revision for chronic knee periprosthetic joint infection (kPJI).

Methods

A retrospective cohort study of 50 chronic kPJI patients treated with two types of articulating spacers between January 2014 and March 2022 was conducted. The clinical outcomes and functional status of the different articulating spacers were compared. Overall, 17 patients were treated with prosthetic spacers (prosthetic group (PG)), and 33 patients were treated with cement spacers (cement group (CG)). The CG had a longer mean follow-up period (46.67 months (SD 26.61)) than the PG (24.82 months (SD 16.46); p = 0.001).


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 420 - 421
1 May 2024
Oussedik S Haddad FS


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1206 - 1215
1 Nov 2024
Fontalis A Buchalter D Mancino F Shen T Sculco PK Mayman D Haddad FS Vigdorchik J

Understanding spinopelvic mechanics is important for the success of total hip arthroplasty (THA). Despite significant advancements in appreciating spinopelvic balance, numerous challenges remain. It is crucial to recognize the individual variability and postoperative changes in spinopelvic parameters and their consequential impact on prosthetic component positioning to mitigate the risk of dislocation and enhance postoperative outcomes. This review describes the integration of advanced diagnostic approaches, enhanced technology, implant considerations, and surgical planning, all tailored to the unique anatomy and biomechanics of each patient. It underscores the importance of accurately predicting postoperative spinopelvic mechanics, selecting suitable imaging techniques, establishing a consistent nomenclature for spinopelvic stiffness, and considering implant-specific strategies. Furthermore, it highlights the potential of artificial intelligence to personalize care. Cite this article: Bone Joint J 2024;106-B(11):1206–1215


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 120 - 120
2 Jan 2024
Camera A Biggi S Capuzzo A Cattaneo G Tedino R Bolognesi G
Full Access

Fractures of the prosthetic components after total knee arthroplasty (TKA) are rare but dangerous complications, sometimes difficult to diagnose and to manage. Aim of this study is to evaluate the incidence of component breakage and its treatment in our single institution's experience. We retrospectively review our institution registry. From 605 revision knee arthroplasties since 2000 to 2018, we found 8 cases of component breakage, of these 3 belonged to UKA, and 5 belonged to TKA. The UKA fractures were all on the metal tibial component; while 4 TKA fractures were ascribed to the liner (2 Posterior-Stabilized designs and 2 constrained designs) and only one case was on the femoral component. For every patient a revision procedure was performed, in two cases a tibial tubercle osteotomy was performed, while in one case (where the fracture was of the post cam) an arthroscopy was performed prior to the arthrotomy. All of the UKA fractures were treated with a standard revision implant. As regard the TKA, 2 liner fractures were treated with the only liner exchange, while the other 2 liner fractures and the fracture of the metallic component were treated with total knee revision. No intra- and post-operative complications were found. Component breakage after TKA is a serious complication. Its treatment, always surgical, can hide pitfalls, especially if the timing is not correct; indeed apart from the revision of one or more components, the surgeons must address any issues of management of bone defect and ligamentous stability


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims. This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height. Methods. Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components. Results. Femoral components in both MA and KA alignments exhibited a more valgus DTSA compared to native femora. However, DTSA deviation from native was significantly less in KA than in MA (4.8° (SD 2.2°) vs 8.8° (SD 1.8°); p < 0.001). DTSA deviation from native orientation correlated positively with the mechanical lateral distal femoral angle (mLDFA) in KA and negatively in MA (r = 0.53, p < 0.001; r = -0.18, p < 0.001). Medial trochlear height was not restored with either MA or KA, with MA resulting in lower medial trochlear height than KA in the proximal 20% of the trochlea. Lateral and sulcus trochlear height was not restored with either alignment in the proximal 80% of the trochlea. At the terminal arc point, KA replicated sulcus and lateral trochlear height, while MA led to over-restoration. Conclusion. Femoral components aligned in KA demonstrated greater biomimetic qualities than those in MA regarding trochlear sulcus orientation and trochlear height restoration, particularly in valgus femora. Variability across knees was observed, warranting further research to evaluate the clinical implications of these findings. Cite this article: Bone Joint J 2024;106-B(8):817–825


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 45 - 45
1 Oct 2022
Fes AF Pol AP Pérez-Prieto D Gomez PH Alier A Verdié LP Garcia JCM
Full Access

Aim. One of the most severe complications of primary total knee arthroplasty (TKA) is periprosthetic joint infection (PJI). Nowadays, the use of antibiotic-loaded cement for prevention of infection is still controversial. The aim of the present study is to evaluate the use of an antibiotic-loaded cement to reduce the infection rate in primary total knee arthroplasty. Method. Prospective randomized study, with 2893 cemented total knee arthroplasties performed between 2005 and 2010 in our institution. Two different groups were formed depending on which bone cement was used, without antibiotic (the control group) or loaded with erythromycin and colistin (the study group). All patients received the same systemic prophylactic antibiotics. The patients were followed for a minimum of twelve months. The rate of infection was analyzed according to the criteria of the Centers for Disease Control and Prevention (CDC). Results. In 1452 patients the prosthetic components were fixed using bone cement without antibiotic and in 1441 patients bone cement loaded with erythromycin and colistin was used. There were no differences between both groups in terms of demographic data (age, sex and BMI), either in operating time (p>0,05). The rate of infection was similar in both groups, being 2,0% (n=29) in the control group and 1,7% in the study group (p=0,58) at 8,7 years (SD 5,1) of follow up. In terms of prosthetic revision due to any cause (infected or aseptic), there wasn't differences between groups, performing a total of 61 revision arthroplasties in control group and 68 in study group (p>0,05). Moreover, we analyzed the erythromycin resistance rate, being no differences between both groups (p=0.6). Conclusions. The use of erythromycin and colistin-loaded bone cement in total knee arthroplasty did not lead to a decrease in the rate of infection when systemic prophylactic antibiotics were used, a finding that suggests that its use would not be indicated in the general population


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 106 - 106
1 Nov 2021
Franceschetti E De Angelis D'Ossat G Palumbo A Paciotti M Franceschi F Papalia R
Full Access

Introduction and Objective. TKA have shown both excellent long-term survival rate and symptoms and knee function improvement. Despite the good results, the literature reports dissatisfaction rates around 20%. This rate of dissatisfaction could be due to the overstuff that mechanically aligned prostheses could produce during the range of motion. Either size discrepancy between bone resection and prosthetic component and constitutional mechanical tibiofemoral alignment (MTFA) alteration might increase soft tissue tension within the joint, inducing pain and functional limitation. Materials and Methods. Total knee arthroplasties performed between July 2019 and September 2020 were examined and then divided into two groups based on the presence (Group A) or absence (Group B) of patellofemoral overstuff, defined as a thickness difference of more than 2 mm between chosen component and bone resection performed, taking into account at least one of the following: femoral medial and lateral condyle, medial or lateral trochlea and patella. Based on pre and post-operative MTFA measurements, Group A was further divided into two subgroups whether the considered alignment was modified or not. Patients were assessed pre-operatively and at 6 months post-op using the Knee Society Score (KSS), Oxford Knee Score (OKS), Forgotten Joint Score (FJS), Visual Analogue Scale (VAS) and Range of Motion (ROM). Results. One hundred total knee arthroplasties were included in the present study, 69 in Group A and 31 in group B. Mean age and BMI of patients was respectively 71 and 29.2. The greatest percentage of Patellofemoral Overstuff was found at the distal lateral femoral condyle. OKS, KSS functional score, and FJS were statistically significant higher in patients without Patellofemoral Overstuff. Therefore, Group A patients with a non-modified MTFA demonstrated statistically significant better KSS, ROM and FJS. Conclusions. Patellofemoral Overstuff decrease post-operative clinical scores in patients treated with TKA. The conventional mechanically aligned positioning of TKA components might be the primary cause of prosthetic overstuffing leading to worsened clinical results. Level of evidence: III; Prospective Cohort Observational study;


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 386 - 387
1 Oct 2006
Chelule K Seedhom B Hafez M Sherman K
Full Access

Aim: To develop a 3-D pre-surgical planner that facilitates selection and placement of correct prosthetic components in the joint, and the design of patient specific templates to use intra-operatively to reproduce the pre-planned implantation procedure, in total knee replacement (TKR) surgery. Design/Methods: The process begun with loading of pre-operative CT scan data of cadaver knee, onto medical software, followed by reconstructions of 3D models of the joint. Then measurements of anterior-posterior diameter of the femoral condyles of the 3D models of the joint were used to select and import a correct CAD drawing of prostheses from a database of electronic files available in a range of sizes. The selected prosthetic components were positioned and aligned on the 3-d model of the joint, making sure that the anterior flange of the femoral prosthesis component did not violate superior cortical bone of trochlea. Whilst the tibial stem was placed central within the medullar space of the bone, and the plane of the tibial cut was perpendicular to the long axis of the tibia. The planned data were next exported to a CAD environment where template to prepare the bone to receive the prostheses, was designed. A template was designed to press fit on a bone (e.g. femur), via minimum number of cylindrical protrusions with their ends made to conform to the geometry of that bone at the regions of contact. The integrated surgical tools were secured to the bones with pins through each of the protrusions, and were equipped with saw guide slits for cutting the bone, and with drill guides for drilling the fixation holes. Thereafter the files describing templates and prosthetic components selected for cadaveric joint concerned were sent to rapid prototyping machine for manufacturing. Results: Fourteen procedures were performed on cadaveric knees to date. Visual examination of the joint has revealed the 3-D planning system enabled correct selection of appropriate prosthetic components and alignment, as evidenced by absence of protrusions or overhanging beyond the edges of the bones. The resected bone surfaces were visually smooth and flat. Gaps between the bones and the internal surfaces of the prosthetic components were measured using steel shim gauges, and largest recorded was 0.9mm. Laxity between the femur and tibia was absent and the joint attained full range of flexion. Dimensional deviations of post-operative scans of the prepared bones from the pre-planned ones were between 0.5 and 0.9mm. The templates after their use were shown capable to withstand the rigors of theatre environment. Conclusion: With the planning software, it has been shown that it is possible to design a simple to use implantation guidance system according to the final position of the restorative prosthesis and the bone pathological condition. Pre-operative planner system relieves the clinician from multiple intra-operative decisions. The system is ideal for critical anatomical situations and eliminates possible manual placement errors such as those from extra and intra-medullary alignment tool. Less inventory required of both implants and instrumentation means reduced complexity of procedure, surgical time and cost


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 56 - 56
1 Feb 2021
Catani F Illuminati A Ensini A Zambianchi F Bazzan G
Full Access

Introduction. Robotics have been applied to total knee arthroplasty (TKA) to improve surgical precision in component placement and joint function restoration. The purpose of this study was to evaluate prosthetic component alignment in robotic arm-assisted (RA)-TKA performed with functional alignment and intraoperative fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. It was hypothesized that functionally aligned RA-TKA the femoral and tibial cuts would be performed in line with the preoperative joint line orientation. Methods. Between September 2018 and January 2020, 81 RA cruciate retaining (CR) and posterior stabilized (PS) TKAs were performed at a single center. Preoperative radiographs were obtained, and measures were performed according to Paley's. Preoperatively, cuts were planned based on radiographic epiphyseal anatomies and respecting ±3° boundaries from neutral coronal alignment. Intraoperatively, the tibial and femoral cuts were modified based on the individual soft tissue-guided fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. Robotic data were recorded. Results. A total of 56 RA-TKAs performed on varus knees were taken into account. On average, the tibial component was placed at 1.9° varus (SD 0.7) and 3.3° (SD 1.0) in the coronal and sagittal planes, respectively. The average femoral component alignment, based on the soft tissue tensioning with spoons, resulted as follows: 0.7° varus (SD 1.7) in the coronal plane and 1.8° (SD 2.1) of external rotation relative to surgical transepicondylar axis in the transverse plane. A statistically significant linear direct relationship was demonstrated between radiographic epiphyseal femoral and tibial coronal alignment and femoral (r=0.3, p<0.05) and tibial (r=0.3, p<0.01) coronal cuts, resepctively. Conclusion. Functionally aligned RA-TKA performed in varus knees, aiming for ligaments’ preservation and balanced flexion/extension gaps, provided joint line respecting femoral and tibial cuts on the coronal plane


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 191 - 191
1 Sep 2012
Ensini A Timoncini A Belvedere C Cenni F Leardini A Giannini S
Full Access

Computer-assisted techniques in total knee replacement (TKR) have been introduced to improve bone cuts execution and relevant prosthesis components positioning. Although these have resulted in good surgical outcomes when compared to the conventional TKR technique, the surgical time increase and the use of additional invasive devices remain still critical. In order to cope with these issues, a new technology in TKR has been introduced also for positioning prosthetic components according to the natural lower-limb alignment. This technique is based on custom-fit cutting block derived from patient-specific lower-limb scan acquisition. The purpose of this study is to assess the accuracy of the custom-fit technology by means of a knee surgical navigation system, here used only as measurement system, and post-operative radiographic evaluations. Particularly, the performances of two different custom-fit cutting blocks realized from as many scan acquisitions have been here reported. Thirty patients affected by primary knee osteoarthritis were enrolled in this study. Fifteen patients were implanted with GMK® (Medacta-International, Castel San Pietro, CH) and as many patients with Journey® (Smith&Nephew, London, UK). Both TKR designs were implanted by using custom-fit blocks for bone cut executions provided by the same TKR manufacturers according to a pre-operative web planning approved by the surgeon. Particularly, the cutting block for the former design was built from CT scan acquisition of the hip, knee and ankle, whereas that for the latter design from MRI scans acquisition of the knee and X-ray lower-limb overview. A knee surgical navigation system (Stryker®-Leibinger, Freiburg, Germany) was used for recording intra-operative alignment of bone cuts as performed by means of the custom-fit cutting blocks and relevant component positioning. Prosthetic components alignments were also assessed post-operatively on X-ray images according to a shape-matching technique. The accuracy of the custom-fit blocks was evaluated through the comparison between pre-operative planning, and intra/post-operative data. Discrepancies above 3° and millimeters were considered as outliers. Within the patient cohort, nine cases were fully analyzed at the moment and here reported. Over them and except for one case, the discrepancy between pre-operative planned femoral/tibial resection level on the frontal plane and the corresponding measured intra-operatively was within 3 mm, being 5 mm in the worse case. Two outliers were observed for the corresponding femoral/tibial cut rotational alignment. Particularly, in one patient, the discrepancy in femoral cut alignment was of 8° in flexion and 6° in external rotation; in another patient this was of 4° in extension and 4° in external rotation in the femoral and tibial cut alignment, respectively. Post-operative radiographs evaluations for the final prosthetic components revealed that femoral/tibial alignment were within 3° in all cases, except for those patients that were already outliers. These preliminary results reveal the efficacy of the custom-fit cutting block for TKR. These were generally fitted properly and final prosthetic components were accurately placed, although some discrepancies were observed. This new technology seems to be a valid alternative to conventional and computer-assisted techniques. More consistent conclusions can be deduced after final evaluation of all patients


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 75 - 75
1 Jan 2004
Kumar G Ramakrishnan M Donnachie NJ
Full Access

Hips and knees are commonly replaced joints for which several types of prostheses are available. As newer versions of the prostheses are brought in, older versions are phased out. When revision is for an isolated component failure as in, wear of acetabular cup, isolated revision of the acetabular cup is an accepted procedure. If the plan is to revise just the isolated component then that particular model of prosthesis should still be available. In an attempt to check the availability of revision components for joint replacements we wrote to ten prostheses manufacturers enquiring the availability of prosthetic components. To have a comparison, we also wrote to eighteen leading car manufacturers enquiring about the duration and any guarantees on the availability of car spare parts. From our survey we found that the availability of the revision implants was satisfactory in that all the prostheses manufacturers were eager to provide as much assistance as possible. The draw back is that there are no regulations to ensure the availability of these prosthetic components for any length of time after discontinuation of a particular model. The car manufacturers are not under any obligation to provide spare parts for discontinued models. The argument put forward by some manufacturers for providing spare parts up to ten years from discontinuing the model was that “it would not reflect well on the company” if it were for any lesser length of time. Conclusion: At present though there are no regulations on the time period of availability of total joint prosthetic components. The manufacturers have taken it upon themselves to provide the prosthetic components whenever a specific request is made. If the manufacturers say they can not provide the implants there is nothing in the governmental regulations that provide for recourse


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 97 - 97
1 Mar 2008
Chen E Lanovaz JL Ellis RR
Full Access

A near real-time, image-free, contact-determination algorithm is developed for the use of analyzing in vivo kinematics of an artificial knee joint. Using a three-dimensional motion tracker and the knowledge of the precise geometries of the contacting surfaces, the contact regions between two articular surfaces can be determined within seconds. The results are validated with the use of Fuji films, which show high degree of accordance in the contact regions determined. Applications include knee kinematics validation, TKA wear-pattern analysis, and intro-operative surgical assessment. To determine the in vivo contact locations between total knee prosthetic components without the use of any imaging modality. Validated with the Fuji film contact study, this computer algorithm provides an image-free, and accurate way of finding contact regions between prosthetic components. An image-free, near real-time, algorithm is developed to study the in vivo contact condition between prosthetic components. A Dynamic Reference Body (DRB) is attached to each of the Total Knee Arthroplasty component and their motions, while in contact with each other, are tracked with an optical spatial sensor. The geometries of the articular surfaces, represented in point-clouds with point-normal, were obtained from a laser-scanner at 0.4mm resolution. For each recorded pose, the contact between articular surfaces were determined by first matching point normal and then performing a nearest-point search, both facilitated by the use of a generalized binary-search-tree (kd-tree). A size-3 Sigma Knee (Johnson& Johnson), represented by approximately 31,000/19,000 points for each of the femoral/tibial component, respectively, is used for this study. For each pose, the contact between components can be determined under one second on a 2GHz PC, rendering it applicable for intra-operative use. The contacts between prosthetic components are visualized using standard computer graphics techniques and contrasted with the contact obtained by Fuji film of the same pose. Depicted below, the contact regions determined by these two methods show high degree of accordance with each other. This allows for, in particular, an image-free TKA wear-pattern analysis. Please contact Author for diagrams


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 204 - 204
1 Apr 2005
Tigani D Rimondi E Trentani P Trentani F Antonioli D Giunti A
Full Access

Patellar tracking is the most common complication observed following total knee arthroplasty. It may constitute a minor disorder or even frank dislocation. Its main cause is a rotation defect in the prosthetic components. CT is the most reliable instrumental test to assess this rotation defect, and an excellent aid for planning a possible revision operation. From January 1999 to November 2003 we treated 33 patients with a total of 35 painful knees using TC prostheses. Ten patients were male and 33 female. Mean age was 66 years. We performed CT scanning using a modified Berger technique. The lower limbs were extended and scans were performed perpendicular to the mechanical axis of the knee from the supracondylar region of the femur to the plane passing under the distal end of the tibial component up to the anterior tibial tuberosity. Reference lines to assess the rotation of each prosthetic component were drawn electronically on the scan planes. Adding together the rotation values of the prosthetic components, we observed that when total internal rotation was between 10° and 4°, there was subluxation or frank dislocation. When total internal rotation was between 1° and 4° the disorder was not severe, such as patellar tilt. When total internal rotation was less than 1° or when the components were externally rotated, no femorotibial compartment disorders were observed. The modified Berger technique enabled us to correlate the degree of prosthetic internal rotation with the severity of the disorder and further demonstrate the benefits of femoral component external rotation on patellar glide and ligament balance of the prosthesis. The authors believe that using CT with the helicoidal technique, by modifying Berger’s technique, enables an accurate assessment of prosthetic component rotation, subsequent correlation with femoro-patella symptoms, and adequate pre-operative planning in case of revision surgery


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 10 - 10
1 Apr 2019
De Biase C Fiorentino G Catellani F Ziveri G Banci L Meoli A Bloch HR
Full Access

Background. The current use of a spherical prosthetic humeral head in total shoulder arthroplasty results in an imprecise restoration of the native geometry and improper placement of the center of rotation, maintained in a constant position, in comparison to the native head and regardless of glenoid component conformity. A radially-mismatched spherical head to allow gleno-humeral translation is a trade-off that decreases the contact area on the glenoid component, which may cause glenoid component wear. This finding suggests that the use of a non-spherical head with a more conforming glenoid component may reduce the risk of glenoid component wear by allowing gleno-humeral translation while increasing the contact area. A non-spherical prosthetic head more accurately replicates the head shape, rotational range of motion and gleno-humeral joint kinematics than a spherical prosthetic head, compared with the native humeral head. The combination of inversion of the bearing materials with the non-spherical configuration of the humeral head may thus decrease polyethylene wear. Aim of the present study is to evaluate in vitro wear behaviour of an all-polyethylene elliptical humeral head component against a metallic glenoid component in an anatomic configuration. Material and methods. The prosthetic components tested are from the Mirai. ®. Modular Shoulder System by Permedica S.p.A.. The prosthetic bearing components were tested in their anatomic configuration: the humeral head rubbing against the glenoid inlay, assembled over the glenoid base-plate. The glenoid insert is made of Ti6Al4V alloy coated with TiNbN. The glenoid insert, as the glenoid base-plate have the same shape which reproduce the native shape of the glenoid. Moreover, the glenoid insert has a concave articular surface described by two different radii on orthogonal planes. The vitamin E-blended UHMWPE humeral head is not spherical but elliptic-shaped with an articular surface described by two different profiles in sagittal and coronal plane. The component sizes combination tested have the greatest radial mismatches allowed between humeral head and glenoid insert. The test was performed up to 2.5 million of cycles applying a constant axial load of 756 N. Results. After 2.500.000 cycles the mean mass loss from the humeral head was 0.68 mg. The mean wear rate of the humeral head was 0.28 mg/Mc (SD 0.45 mg/Mc). The surface of the humeral heads showed an elliptical worn area with matt and polished areas with scratching. The surface of the TiNbN-coated glenoid insert counterparts did not show wear signs. Conclusion. The tested prosthetic humeral head has a non-spherical shape with an elliptical base and 2 different radii on sagittal and coronal plane. Also the tested glenoid insert has 2 different radii on sagittal and coronal planes. This components geometry leads to a radial mismatch between head and glenoid on sagittal and coronal planes. A different kinematics, allowing gleno-humeral translation while increasing the contact area, radial mismatch in different planes and the inversion of bearing materials may have a role in reducing component wear and may explain the extremely low wear rate found in the present study


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 132 - 132
1 Feb 2020
Paglia A Goderecci R Calvisi V
Full Access

Introduction. Functional outcomes of mechanically aligned (MA) total knee arthroplasty have plateaued. The aim of this study is to find an alternative technique for implant positioning that improves functional outcomes of TKA. Methods. We prospectively randomized 100 consecutive patients undergoing TKA into two groups: in the group A an intramedullary femoral guide and an extramedullary tibial guide were used with aim to obtain a neutral traditional mechanical alignment; in the group B an extramedullary femoral guide set on distal femoral condyles and an extramedullary tibial guide neutrally aligned were used to obtain an adaptation of the conventional MA technique. Patients were followed-up clinically with the Short Form Health Survey (SF-12), Oxford Knee Score (OKS) and Visual Analogue Score (VAS) questionnaires pre-operatively and then at 1 year post-operatively. Mechanical alignment was calculated on standing weight bearing Xray pre- and post-operatively. T-test was used to compare the results between groups. Results. Both groups showed an improvement of clinical scores. At 1 year of follow-up OKS and SF-12 were significantly higher in group B: 47,6 ±0.75 and 46.5 ±0.76 respectively; VAS was similar in both groups. Values of mechanical alignment changed from 6.45 ±8.45 to 0.25 ±0.91 for group A and from 6.8 ±7.94 to 2.5 ±4.7 for group B. Conclusion. This study shows that adjusted mechanical alignment (AMA) with a small under-correction of frontal deformity lead to improved functional scores following total knee replacement compared to conventional technique of neutral alignment. These results are satisfactory at short follow-up but long-term studies are needed to evaluate the difference in the rate of wear of the prosthetic components


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 22 - 27
1 Oct 2016
Bottomley N Jones LD Rout R Alvand A Rombach I Evans T Jackson WFM Beard DJ Price AJ

Aims. The aim of this to study was to compare the previously unreported long-term survival outcome of the Oxford medial unicompartmental knee arthroplasty (UKA) performed by trainee surgeons and consultants. . Patients and Methods. We therefore identified a previously unreported cohort of 1084 knees in 947 patients who had a UKA inserted for anteromedial knee arthritis by consultants and surgeons in training, at a tertiary arthroplasty centre and performed survival analysis on the group with revision as the endpoint. Results. The ten-year cumulative survival rate for revision or exchange of any part of the prosthetic components was 93.2% (95% confidence interval (CI) 86.1 to 100, number at risk 45). Consultant surgeons had a nine-year cumulative survival rate of 93.9% (95% CI 90.2 to 97.6, number at risk 16). Trainee surgeons had a cumulative nine-year survival rate of 93.0% (95% CI 90.3 to 95.7, number at risk 35). Although there was no differences in implant survival between consultants and trainees (p = 0.30), there was a difference in failure pattern whereby all re-operations performed for bearing dislocation (n = 7), occurred in the trainee group. This accounted for 0.6% of the entire cohort and 15% of the re-operations. . Conclusion. This is the largest single series of the Oxford UKA ever reported and demonstrates that good results can be achieved by a heterogeneous group of surgeons, including trainees, if performed within a high-volume centre with considerable experience with the procedure. Cite this article: Bone Joint J 2016;(10 Suppl B):22–7


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 112 - 112
1 Jan 2017
Valente G Crimi G Cavazzuti L Benedetti M Tassinari E Taddei F
Full Access

In the congenital hip dysplasia, patients treated with total hip replacement (THR) often report persistent disability and pain, with unsatisfactory function and quality of life. A major challenge is to restore the center of rotation of the hip and a satisfactory abduction function [1]. The position of the acetabular cup during THR might be crucial, as it affects abduction moment and motor function. Recently, several software systems have been developed for surgical planning of endoprostheses. Previously developed software called HipOp [2], which is routinely used in clinics, allows surgeons to properly position the prosthetic components into the 3D space of CT data. However, this software did not allow to simulate the articular range of motion and the condition of the abductor muscles. Our aim is to present HipOpCT, an advanced version of the software that includes 3D musculoskeletal planning, through the application to hip dysplasia patients to add knowledge in the diagnosis and treatment of such patients who need THR. 40 hip dysplasia patients received pre-operative CT scanning of pelvis and thighs and had their THR surgery planned using HipOpCT. The base planning includes import of CT data, positioning of prosthetic components interactively through multimodal display, as well as geometrical measurements of the implant and the host bone. The advanced planning additionally includes evaluation of femoro-acetabular impingement and calculation of leg lengths, abductor muscle lengths and lever arms through the automatic creation of a musculoskeletal model. The musculoskeletal parameters in all patients were calculated during the surgical planning, and the data were processed to evaluate pre- and post-operative differences in leg length discrepancy, length and lever arm of the abductor muscles, and how these parameters correlated. The surgical planning led to an increase in the operated leg length of 7.6 ± 5.7 mm. The variation in abductors lever arm was −0.9% ± 4.8% and significantly correlated with the variation in the operated leg length (r = −0.49), pre-operative leg length discrepancy (r = 0.32) and variation in abductors length (r = −0.32). The variation in abductors length was 6.6% ± 5.5%, and significantly correlated with the variation in the operated leg length (r = 0.92), post-operative leg length discrepancy (r = 0.37), pre-operative abductors length (r = −0.37) and variation in abductors lever arm (r = −0.32). The increase in the operated leg length was strongly correlated to the increase in abductor muscle length. Conversely, abductor lever arms slightly decreased on average, and were inversely correlated to leg length variation and abductors lengths. This interactive technology for surgical planning represent a powerful tool for orthopaedic surgeons to consider the best muscle reconstruction, and for rehabilitation specialists to achieve the best functional recovery based on biomechanical outcomes. In a parallel study, we are investigating how these advanced planning is reflected onto the function, pain and biomechanical outcome after a rehabilitation protocol is completed


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 37
1 Mar 2002
Afriat J Guegnon G
Full Access

Purpose: Kinematics of the total knee arthroplasty plateau has been widely studied. Many methods can be used: opto-electronic captors, electromagnetic knee device, radiography, repositioning with the CAO model. We report a simple method based on calculating the position of two radio-opaque markers and the contours of the prosthetic components. Material and methods: Twenty patients with a unilateral mobile plateau total knee arthroplasty were studied. An image amplifier linked to a digital recorder (frequency 25 Hz), CAO models of the implant, and adapted software (Matlab) were used. Each patient performed a series of movements, standing up from the sitting position, within the fluoroscopic field. Each sequence was digitalized. Kinematic images were sampled at 6 Hz. Different parameters were measured on each sampled image: position of two radio-opaque markers included in the polyethylene insert and characteristic dimensions of the prosthesis components. These 2D recordings were used to deduct the relative 3D position of each of the prosthetic components. Laws of analytic geometry and functional analysis were used to resolve the triangular matrices needed to transform the 2D measures into 3D values. Angular and linear positions of the prosthetic components were established for different times t. Reconcatenation by time produced an kinematic analysis of the pros-thesis behaviour. Results: This method allowed us to establish the kinematics of the total knee arthroplasty mobile plateau with a precision of 0.2 mm and 0.4°. The proposed analysis method is reliable and precise. It is less costly in development time than methods based on automatic repositioning of 3D models of the implant on fluoroscopic images. Conclusion: The measurement method proposed requires radio-opaque markers positioned in orthogonal directions so they are visible during movements. Although we used a semi-automatic calculation protocol, totally automatic systems can be applied to process fluoroscopic images