Advertisement for orthosearch.org.uk
Results 1 - 20 of 23
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 34 - 44
1 Jan 2022
Beckers L Dandois F Ooms D Berger P Van Laere K Scheys L Vandenneucker H

Aims. Higher osteoblastic bone activity is expected in aseptic loosening and painful unicompartmental knee arthroplasty (UKA). However, insights into normal bone activity patterns after medial UKAs are lacking. The aim of this study was to identify the evolution in bone activity pattern in well-functioning medial mobile-bearing UKAs. Methods. In total, 34 patients (13 female, 21 male; mean age 62 years (41 to 79); BMI 29.7 kg/m. 2. (23.6 to 42.1)) with 38 medial Oxford partial UKAs (20 left, 18 right; 19 cementless, 14 cemented, and five hybrid) were prospectively followed with sequential 99mTc-hydroxymethane diphosphonate single photon emission CT (SPECT)/CT preoperatively, and at one and two years postoperatively. Changes in mean osteoblastic activity were investigated using a tracer localization scheme with volumes of interest (VOIs), reported by normalized mean tracer values. A SPECT/CT registration platform additionally explored cortical tracer evolution in zones of interest identified by previous experimental research. Results. Significant reduction of tracer activity from the preoperative situation was found in femoral and anteromedial tibial VOIs adjacent to the UKA components. Temporarily increased osteoblastic bone activity was observed in VOIs comprising the UKA keel structure at one year postoperatively compared to the preoperative activity. Persistent higher tracer uptake was found in the posterior tibial cortex at final follow-up. Multivariate analysis showed no statistical difference in osteoblastic bone activity underneath cemented or cementless components. Conclusion. Well-functioning medial mobile-bearing UKAs showed distinct changes in patterns of normalized bone tracer activity in the different VOIs adjacent to the prosthetic components, regardless of their type of fixation. Compared to the preoperative situation, persistent high bone activity was found underneath the keel and the posterior tibial cortex at final follow-up, with significant reduced activity only being identified in femoral and anteromedial tibial VOIs. Cite this article: Bone Joint J 2022;104-B(1):34–44


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 817 - 825
1 Aug 2024
Borukhov I Ismailidis P Esposito CI LiArno S Lyon J McEwen PJ

Aims. This study aimed to evaluate if total knee arthroplasty (TKA) femoral components aligned in either mechanical alignment (MA) or kinematic alignment (KA) are more biomimetic concerning trochlear sulcus orientation and restoration of trochlear height. Methods. Bone surfaces from 1,012 CT scans of non-arthritic femora were segmented using a modelling and analytics system. TKA femoral components (Triathlon; Stryker) were virtually implanted in both MA and KA. Trochlear sulcus orientation was assessed by measuring the distal trochlear sulcus angle (DTSA) in native femora and in KA and MA prosthetic femoral components. Trochlear anatomy restoration was evaluated by measuring the differences in medial, lateral, and sulcus trochlear height between native femora and KA and MA prosthetic femoral components. Results. Femoral components in both MA and KA alignments exhibited a more valgus DTSA compared to native femora. However, DTSA deviation from native was significantly less in KA than in MA (4.8° (SD 2.2°) vs 8.8° (SD 1.8°); p < 0.001). DTSA deviation from native orientation correlated positively with the mechanical lateral distal femoral angle (mLDFA) in KA and negatively in MA (r = 0.53, p < 0.001; r = -0.18, p < 0.001). Medial trochlear height was not restored with either MA or KA, with MA resulting in lower medial trochlear height than KA in the proximal 20% of the trochlea. Lateral and sulcus trochlear height was not restored with either alignment in the proximal 80% of the trochlea. At the terminal arc point, KA replicated sulcus and lateral trochlear height, while MA led to over-restoration. Conclusion. Femoral components aligned in KA demonstrated greater biomimetic qualities than those in MA regarding trochlear sulcus orientation and trochlear height restoration, particularly in valgus femora. Variability across knees was observed, warranting further research to evaluate the clinical implications of these findings. Cite this article: Bone Joint J 2024;106-B(8):817–825


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 22 - 27
1 Oct 2016
Bottomley N Jones LD Rout R Alvand A Rombach I Evans T Jackson WFM Beard DJ Price AJ

Aims. The aim of this to study was to compare the previously unreported long-term survival outcome of the Oxford medial unicompartmental knee arthroplasty (UKA) performed by trainee surgeons and consultants. . Patients and Methods. We therefore identified a previously unreported cohort of 1084 knees in 947 patients who had a UKA inserted for anteromedial knee arthritis by consultants and surgeons in training, at a tertiary arthroplasty centre and performed survival analysis on the group with revision as the endpoint. Results. The ten-year cumulative survival rate for revision or exchange of any part of the prosthetic components was 93.2% (95% confidence interval (CI) 86.1 to 100, number at risk 45). Consultant surgeons had a nine-year cumulative survival rate of 93.9% (95% CI 90.2 to 97.6, number at risk 16). Trainee surgeons had a cumulative nine-year survival rate of 93.0% (95% CI 90.3 to 95.7, number at risk 35). Although there was no differences in implant survival between consultants and trainees (p = 0.30), there was a difference in failure pattern whereby all re-operations performed for bearing dislocation (n = 7), occurred in the trainee group. This accounted for 0.6% of the entire cohort and 15% of the re-operations. . Conclusion. This is the largest single series of the Oxford UKA ever reported and demonstrates that good results can be achieved by a heterogeneous group of surgeons, including trainees, if performed within a high-volume centre with considerable experience with the procedure. Cite this article: Bone Joint J 2016;(10 Suppl B):22–7


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 7 - 7
1 Oct 2019
Catani F Ensini A Zambianchi F Illuminati A Matveitchouk N
Full Access

Introduction. Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated high reliability of robotic-arm assisted UKA in component placement and executing a soft-tissue tensioning plan, with excellent short-term survivorship. Few studies have investigated survivorship and patients' satisfaction at longer follow-ups. Therefore, the purpose of the present study was to determine the survivorship, clinical results and patients' satisfaction of robotic-arm assisted UKAs at a mid-term follow-up, with a minimum of 5 years of follow-up. Methods. The present retrospective study includes 252 patients (260 knees) who underwent robotic-arm assisted fixed bearing metal backed UKAs at a single centre between April 2011 and July 2013. The mean age at surgery was 66.2 years (SD 8.6). Post-operatively, patients were administered the Forgotten Joint Score-12 (FJS) and asked about their satisfaction level after knee surgery (grade from 1 to 5). Post-operative complications were recorded. Failure mechanisms, revisions and reoperations were also assessed. Kaplan-Meier survival curves were calculated, considering reoperation for all causes and revision as the events of interest. Results. A total of 223 patients (231 robotic-arm assisted UKAs) were assessed at a mean follow-up of 5.8 years post-operatively (88.5% follow-up rate, min. 60 months, max. 87 months). In 219 cases, a medial robotic-arm assisted UKA was implanted, in 12 cases a lateral implant was performed. Five medial robotic-arm assisted UKAs were revised, resulting in a survivorship of 98% (C.I. 96.0%–99.1%). One case underwent revision for prosthetic joint infection, one for tibial aseptic loosening, one for post-traumatic tibial plateau fracture, and two for unexplained pain. No lateral robotic-arm assisted UKAs were revised, resulting in a survivorship of 100%. On average, the FJS and the satisfaction level resulted 75.6 (SD 26.1) and 4.2 (SD 1.0) in medial UKAs, and 81.7 (SD 15.3) and 4.4 (SD 0.8) in lateral UKAs, respectively. In medial UKAs 83% of the examined cohort reported good/excellent FJS outcomes, while 92% of the lateral UKA patients had good/excellent FJS results. In medial UKAs, male patients resulted to have better FJS (p<0.01) and higher satisfaction level (p<0.03) compared to female patients, while no outcome differences were reported in patients with BMI>30 and among different age groups. Given the small number of lateral UKAs included in the present patients' cohort, no statistical analysis was performed on this group. Conclusion. In the present study, survivorship and clinical outcomes of a large cohort of 223 patients undergoing medial and lateral robotic-arm assisted UKAs were assessed at a mean of 5.8 years of follow-up. The overall survivorship was found to be 98%, with unexplained knee pain as the most common reason for UKA revision. The present study shows that robotic-arm assisted UKA patients had lower revision rates for aseptic loosening and osteoarthritis progression compared to conventional UKA at mid-term follow-up, as reported in the literature. The good post-operative clinical scores highlight the efficacy of robotic-arm assisted UKA in restoring knee function and relieving pain. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 337 - 345
1 Mar 2015
Jaroma AVJ Soininvaara TA Kröger H

Total knee arthroplasty (TKA) is known to lead to a reduction in periprosthetic bone mineral density (BMD). In theory, this may lead to migration, instability and aseptic loosening of the prosthetic components. Bisphosphonates inhibit bone resorption and may reduce this loss in BMD. We hypothesised that treatment with bisphosphonates and calcium would lead to improved BMD and clinical outcomes compared with treatment with calcium supplementation alone following TKA. A total of 26 patients, (nine male and 17 female, mean age 67 years) were prospectively randomised into two study groups: alendronate and calcium (bisphosphonate group, n = 14) or calcium only (control group, n = 12). Dual energy X-ray absorptiometry (DEXA) measurements were performed post-operatively, and at three months, six months, one, two, four, and seven years post-operatively. . Mean femoral metaphyseal BMD was significantly higher in the bisphosphonate group compared with controls, up to four years following surgery in some areas of the femur (p = 0.045). BMD was observed to increase in the lateral tibial metaphysis in the bisphosphonate group until seven years (p = 0.002), and was significantly higher than that observed in the control group throughout (p = 0.024). There were no significant differences between the groups in the central femoral metaphyseal, tibial medial metaphyseal or diaphyseal regions of interest (ROI) of either the femur or tibia. Bisphosphonate treatment after TKA may be of benefit for patients with poor bone quality. However, further studies with a larger number of patients are necessary to assess whether this is clinically beneficial. Cite this article: Bone Joint J 2015;97-B:337–45


Bone & Joint Open
Vol. 4, Issue 12 | Pages 914 - 922
1 Dec 2023
Sang W Qiu H Xu Y Pan Y Ma J Zhu L

Aims

Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial.

Methods

The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival.


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 269 - 276
1 Mar 2023
Tay ML Monk AP Frampton CM Hooper GJ Young SW

Aims

Unicompartmental knee arthroplasty (UKA) has higher revision rates than total knee arthroplasty (TKA). As revision of UKA may be less technically demanding than revision TKA, UKA patients with poor functional outcomes may be more likely to be offered revision than TKA patients with similar outcomes. The aim of this study was to compare clinical thresholds for revisions between TKA and UKA using revision incidence and patient-reported outcomes, in a large, matched cohort at early, mid-, and late-term follow-up.

Methods

Analyses were performed on propensity score-matched patient cohorts of TKAs and UKAs (2:1) registered in the New Zealand Joint Registry between 1 January 1999 and 31 December 2019 with an Oxford Knee Score (OKS) response at six months (n, TKA: 16,774; UKA: 8,387), five years (TKA: 6,718; UKA: 3,359), or ten years (TKA: 3,486; UKA: 1,743). Associations between OKS and revision within two years following the score were examined. Thresholds were compared using receiver operating characteristic analysis. Reasons for aseptic revision were compared using cumulative incidence with competing risk.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 3 - 3
1 Oct 2018
Catani F Zambianchi F Marcovigi A Franceschi G Nardacchione R
Full Access

Introduction. Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated the reliability of robotic assisted UKA over manual UKA in component placement and executing a soft-tissue tensioning plan. The purpose of this multicenter study was to determine the correlation between 3D component positioning and soft-tissue tensioning with short-term clinical results following robotic assisted medial UKA. Methods. Between 2013 and 2016, 349 patients (381 knees) underwent robotic assisted fixed bearing metal backed medial UKAs at two centres. Follow-up was performed at 12 months minimum. Pre- and post-operatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS), Forgotten Joint Score 12 (FJS), and Short-Form summary scale (SF-12) surveys. Clinical results for every score were stratified as ‘excellent’, ‘mild’ and ‘insufficient’. Post-operative complications were recorded. Failure mechanisms, reoperations and post-operative knee pain were also assessed. Intra-operative robotic data relative to femoral and tibial component placement in the coronal, sagittal and horizontal plane, as well as femoro-tibial gaps at different knee flexion angles were also collected. Results. A total of 338 robotic assisted medial UKAs (309 patients) were assessed at an average follow-up of 33.5 months post-operatively (89% follow-up rate). Three implants were revised, resulting in a survivorship of 99.0% (C.I. 97.0%–99.7%), one for prosthetic joint infection and two for tibial aseptic loosening. All clinical post-operative scores were significantly improved from the pre-operative scores. The following statistically significant correlations were found between intra-operative robotic data and outcomes considered individually: femoral component coronal alignment influenced KOOS Symptoms, Pain and Quality of Life (p<0.05), sagittal alignment influenced KOOS Symptoms and Pain (p<0.05), and femoro-tibial gaps at 20°–30° knee flexion influenced KOOS Pain and Function in Activities of Daily Living (p<0.05). Both, tibial sagittal alignment and femoro-tibial gaps at 80°–90° knee flexion were found to correlate with SF-12 Physical Status and presence of post-operative pain (p<0.01). ‘Excellent’ clinical outcomes were reported by those patients who, on average, had the femur placed in neutral alignment in the coronal and horizontal planes (0.2°±1.5 and 0.6°±1.4 respectively) as well as avoided excessive flexion in the sagittal plane (3.7°±3.2). When considering the tibia, better results were reported by patients with the tibial component placed in slight external rotation (2.2°±1.7), varus coronal alignment (1.5°±1.7) and no more than 5° of posterior slope (5.0°±1.0). Regarding femoro-tibial gaps, ‘excellent’ clinical outcomes were reported by patients who were slightly loose between 20°–30° and 80°–90° of knee flexion. Conclusion. In the present study, survivorship and clinical outcomes of a large cohort of 309 patients with medial robotic assisted UKA were contacted with at a mean 3-years. The overall survivorship was found to be 99%, with tibial component failure as the most common reason for UKA revision. The significant difference between pre- and post-operative clinical scores highlights the efficacy of robotic assisted UKA in restoring knee function and relieving pain. Differences in components’ positioning and soft-tissue tensioning demonstrated significant correlation with post-operative clinical outcomes


Bone & Joint Research
Vol. 11, Issue 1 | Pages 32 - 39
27 Jan 2022
Trousdale WH Limberg AK Reina N Salib CG Thaler R Dudakovic A Berry DJ Morrey ME Sanchez-Sotelo J van Wijnen A Abdel MP

Aims

Outcomes of current operative treatments for arthrofibrosis after total knee arthroplasty (TKA) are not consistently positive or predictable. Pharmacological in vivo studies have focused mostly on prevention of arthrofibrosis. This study used a rabbit model to evaluate intra-articular (IA) effects of celecoxib in treating contracted knees alone, or in combination with capsular release.

Methods

A total of 24 rabbits underwent contracture-forming surgery with knee immobilization followed by remobilization surgery at eight weeks. At remobilization, one cohort underwent capsular release (n = 12), while the other cohort did not (n = 12). Both groups were divided into two subcohorts (n = 6 each) – one receiving IA injections of celecoxib, and the other receiving injections of vehicle solution (injections every day for two weeks after remobilization). Passive extension angle (PEA) was assessed in live rabbits at 10, 16, and 24 weeks, and disarticulated limbs were analyzed for capsular stiffness at 24 weeks.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 76 - 76
1 Mar 2012
Iranpour F Konala P Cobb JP Friederich N Hirschmann MT
Full Access

Introduction. SPECT/CT might be a promising diagnostic modality in patients with painful total knee arthroplasty. It was the purpose of our study to introduce a novel standardised SPECT/CT algorithm for assessing patients with painful primary total knee arthroplasty and to evaluate its clinical applicability and inter- and intra-observer variation and reliability. Methods. A novel SPECT/CT localisation scheme, which consists of 9 tibial, 9 femoral and 4 patellar regions on standardised transverse, coronal, and sagittal slices was introduced. It was assessed in 18 consecutive patients with painful knees after total knee arthroplasty. The localisation and level of the tracer uptake on SPECT/CT were noted using a color coded 10 steps graded scale (0-100). The inter and intra-observer reliability were assessed. The femoral and tibial prosthetic component position was assessed in the CT images after 3D reconstruction and aligning them to standardised frames of reference. The average root mean square difference±standard deviations and ranges of these measured angles are presented along with the intraclass correlation coefficients for inter- and intraobserver reliability. Results. The localisation scheme was useful and easily applicable in all 18 cases. The novel classification using the SPECT/CT for the femoral, the tibial and patellar region was reliable. The measurements of component position in SPECT/CT images were highly reliable and feasible in all cases with sufficient visibility of the landmarks. The mean intra-observer difference between the rotational alignment measurements of tibial and femoral components was less than 2° (2SD 1°). The intra-observer variability for these measurements was less than 1 degree (2SD 1°). Conclusions. The introduced algorithm using SPECT/CT in patients after total knee arthroplasty, which combines mechanical (assessment of 3D rotational alignment of the prosthesis in the inherent CT data) and metabolic data (SPECT/CT localisation scheme), was highly reliable and useful. We propose its use in larger scaled clinical studies to investigate its clinical value


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 31 - 31
1 Mar 2012
Kendrick B Pandit H Jenkins C Beard D Gill H Price A Dodd C Murray D
Full Access

Purpose of Study. To assess the incidence of radiolucency in cemented and cementless Oxford unicompartmental knee replacement at two years. Introduction. Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring cementless fixation and others favouring cemented fixation. In addition, there is concern about the radiolucency that frequently develops beneath the tibial component with cemented fixation. The exact cause of the occurrence of radiolucency is unknown but it has been hypothesised that it may suggest suboptimal fixation. Method. Following ethical approval, 62 patients with medial OA were randomised to receive either cemented (n=32) or cementless components (n=30). All patients underwent an identical surgical procedure with either a cemented or cementless Oxford UKR. Patients were assessed clinically by a research physiotherapist and radiologically using screened radiographs. Thirty-eight patients from the trial with follow up of at least two years and well aligned radiographs were identified (cemented n=16, cementless n=22). Results. The patients in the two groups were well matched. Radiological and clinical assessment was at a mean of 2.25 years. There was no significant difference in the clinical scores between the two groups. The median OKS for the cemented group was 43 and for the cementless group was 42.5. Narrow radiolucent lines were seen at the bone-implant interfaces of 63% of the cemented tibial components; partial in 38% and complete in 25%. In the cementless implants, partial radiolucencies were seen in 4.5% and complete radiolucencies in none. The differences are statistically highly significant (p< 0.0001). The lack of radiolucency beneath the cementless tibial components implies satisfactory bone ingrowth and hence fixation. Conclusions. At 2 years the cementless components are well fixed and have similar clinical results to the cemented


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 527 - 534
1 Apr 2010
Streubel PN Gardner MJ Morshed S Collinge CA Gallagher B Ricci WM

It is unclear whether there is a limit to the amount of distal bone required to support fixation of supracondylar periprosthetic femoral fractures. This retrospective multicentre study evaluated lateral locked plating of periprosthetic supracondylar femoral fractures and compared the results according to extension of the fracture distal with the proximal border of the femoral prosthetic component. Between 1999 and 2008, 89 patients underwent lateral locked plating of a supracondylar periprosthetic femoral fracture, of whom 61 patients with a mean age of 72 years (42 to 96) comprising 53 women, were available after a minimum follow-up of six months or until fracture healing. Patients were grouped into those with fractures located proximally (28) and those with fractures that extended distal to the proximal border of the femoral component (33). Delayed healing and nonunion occurred respectively in five (18%) and three (11%) of more proximal fractures, and in two (6%) and five (15%) of the fractures with distal extension (p = 0.23 for delayed healing; p = 0.72 for nonunion, Fisher’s exact test). Four construct failures (14%) occurred in more proximal fractures, and three (9%) in fractures with distal extension (p = 0.51). Of the two deep infections that occurred in each group, one resolved after surgical debridement and antibiotics, and one progressed to a nonunion. Extreme distal periprosthetic supracondylar fractures of the femur are not a contra-indication to lateral locked plating. These fractures can be managed with internal fixation, with predictable results, similar to those seen in more proximal fractures


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 786 - 792
1 Jun 2016
Schotanus MGM Sollie R van Haaren EH Hendrickx RPM Jansen EJP Kort NP

Aims

This prospective randomised controlled trial was designed to evaluate the outcome of both the MRI- and CT-based patient-specific matched guides (PSG) from the same manufacturer.

Patients and Methods

A total of 137 knees in 137 patients (50 men, 87 women) were included, 67 in the MRI- and 70 in the CT-based PSG group. Their mean age was 68.4 years (47.0 to 88.9). Outcome was expressed as the biomechanical limb alignment (centre hip-knee-ankle: HKA-axis) achieved post-operatively, the position of the individual components within 3° of the pre-operatively planned alignment, correct planned implant size and operative data (e.g. operating time and blood loss).


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1637 - 1643
1 Dec 2014
Yang Z Liu H Xie X Tan Z Qin T Kang P

Total knee replacement (TKR) is an effective method of treating end-stage arthritis of the knee. It is not, however, a procedure without risk due to a number of factors, one of which is diabetes mellitus. The purpose of this study was to estimate the general prevalence of diabetes in patients about to undergo primary TKR and to determine whether diabetes mellitus adversely affects the outcome. We conducted a systematic review and meta-analysis according to the Meta-analysis Of Observational Studies in Epidemiology (MOOSE) guidelines. The Odds Ratio (OR) and mean difference (MD) were used to represent the estimate of risk of a specific outcome. Our results showed the prevalence of diabetes mellitus among patients undergoing TKR was 12.2%. Patients with diabetes mellitus had an increased risk of deep infection (OR = 1.61, 95% confidence interval (CI), 1.38 to 1.88), deep vein thrombosis (in Asia, OR = 2.57, 95% CI, 1.58 to 4.20), periprosthetic fracture (OR = 1.89, 95% CI, 1.04 to 3.45), aseptic loosening (OR = 9.36, 95% CI, 4.63 to 18.90), and a poorer Knee Society function subscore (MD = -5.86, 95% CI, -10.27 to -1.46). Surgeons should advise patients specifically about these increased risks when obtaining informed consent and be meticulous about their peri-operative care.

Cite this article: Bone Joint J 2014;96-B:1637–43.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1069 - 1074
1 Aug 2013
Rao BM Kamal TT Vafaye J Moss M

We report the results of revision total knee replacement (TKR) in 26 patients with major metaphyseal osteolytic defects using 29 trabecular metal cones in conjunction with a rotating hinged total knee prosthesis. The osteolytic defects were types II and III (A or B) according to the Anderson Orthopaedic Research Institute (AORI) classification. The mean age of the patients was 72 years (62 to 84) and there were 15 men and 11 women. In this series patients had undergone a mean of 2.34 previous total knee arthroplasties. The main objective was to restore anatomy along with stability and function of the knee joint to allow immediate full weight-bearing and active knee movement. Outcomes were measured using Knee Society scores, Oxford knee scores, range of movement of the knee and serial radiographs. Patients were followed for a mean of 36 months (24 to 49). The mean Oxford knee clinical scores improved from 12.83 (10 to 15) to 35.20 (32 to 38) (p < 0.001) and mean American Knee Society scores improved from 33.24 (13 to 36) to 81.12 (78 to 86) (p < 0.001). No radiolucent lines suggestive of loosening were seen around the trabecular metal cones, and by one year all the radiographs showed good osteo-integration. There was no evidence of any collapse or implant migration. Our early results confirm the findings of others that trabecular metal cones offer a useful way of managing severe bone loss in revision TKR.

Cite this article: Bone Joint J 2013;95-B:1069–74.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 493 - 497
1 Apr 2013
Hino K Ishimaru M Iseki Y Watanabe S Onishi Y Miura H

There are several methods for evaluating stability of the joint during total knee replacement (TKR). Activities of daily living demand mechanical loading to the knee joint, not only in full extension, but also in mid-flexion. The purpose of this study was to compare the varus-valgus stability throughout flexion in knees treated with either cruciate-retaining or posterior-stabilised TKR, using an intra-operative navigation technique. A total of 34 knees underwent TKR with computer navigation, during which the investigator applied a maximum varus-valgus stress to the knee while steadily moving the leg from full extension to flexion both before and after prosthetic implantation. The femorotibial angle was measured simultaneously by the navigation system at every 10° throughout the range of movement. It was found that posterior-stabilised knees had more varus-valgus laxity than cruciate-retaining knees at all angles examined, and the differences were statistically significant at 10° (p = 0.0093), 20° (p = 0.0098) and 30° of flexion (p = 0.0252).

Cite this article: Bone Joint J 2013;95-B:493–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1216 - 1220
1 Sep 2012
Weston-Simons JS Pandit H Jenkins C Jackson WFM Price AJ Gill HS Dodd CAF Murray DW

The Oxford unicompartmental knee replacement (UKR) is an established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis (MCOA), which works well in the young and active patient. However, previous studies have shown that it is reliable only in the presence of a functionally intact anterior cruciate ligament (ACL). This review reports the outcomes, at a mean of five years and a maximum of ten years, of 52 consecutive patients with a mean age of 51 years (36 to 57) who underwent staged or simultaneous ACL reconstruction and Oxford UKR. At the last follow-up (with one patient lost to follow-up), the mean Oxford knee score was 41 (sd 6.3; 17 to 48). Two patients required conversion to TKR: one for progression of lateral compartment osteoarthritis and one for infection. Implant survival at five years was 93% (95% CI 83 to 100). All but one patient reported being satisfied with the procedure. The outcome was not significantly influenced by age, gender, femoral or tibial tunnel placement, or whether the procedure was undertaken at one- or two-stages.

In summary, ACL reconstruction and Oxford UKR gives good results in patients with end-stage MCOA secondary to ACL deficiency.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 656 - 659
1 May 2012
Hwang B Yoon J Nam C Jung K Lee S Han C Moon S

We retrospectively reviewed 30 two-stage revision procedures in 28 patients performed for fungal peri-prosthetic joint infection (PJI) after a primary total knee replacement. Patients were followed for at least two years or until the infection recurred. The mean follow-up for patients who remained free of infection was 4.3 years (2.3 to 6.1). Overall, 17 patients were assessed as American Society of Anesthesiologists grade 3 or 4. The surgical protocol included removal of the infected implant, vigorous debridement and insertion of an articulating cement spacer. This was followed by at least six weeks of antimicrobial treatment and delayed reimplantation in all patients. The mean interval between removal of the prosthesis and reimplantation was 9.5 weeks (6 to 24). After reimplantation, patients took antifungal agents orally for a maximum of six months. Two knees became reinfected at one and two months post-operatively, respectively: one of these subsequently required arthrodesis because of uncontrolled infection.

Fungal PJIs can be treated successfully by removal of all infected material, appropriate antimicrobial treatment and delayed reimplantation.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 629 - 633
1 May 2011
Hirschmann MT Konala P Amsler F Iranpour F Friederich NF Cobb JP

We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose.

A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p < 0.001).

3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 180 - 184
1 Feb 2009
Lim HC Bae JH Hur CR Oh JK Han SH

We retrospectively evaluated eight patients who underwent arthrodesis of the knee using cannulated screws. There were six women and two men, with a mean age of 53 years. The indications for arthrodesis were failed total knee arthroplasty, septic arthritis, tuberculosis, and recurrent persistent infection. Solid union was achieved in all patients at a mean of 6.1 months. One patient required autogenous bone graft for delayed union. One suffered skin necrosis which was treated with skin grafting. The mean limb-length discrepancy was 3.1 cm. On a visual analogue scale, the mean pain score improved from 7.9 to 3.3. According to the Knee Injury and Osteoarthritis Outcome score quality of life items, the mean score improved from 38.3 pre-operatively to 76.6 at follow-up. Cannulated screws provide a high rate of union in arthrodesis of the knee with minimal complications, patient convenience, and a simple surgical technique.