A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in an MHRA-approved clinical investigation to provide a non metallic alternative hip resurfacing product. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures both before and 12 months following surgery in comparison with age and gender matched healthy controls. Eighty-two unilateral cHRA patients consented to this study as part of a larger prospective, non-randomised, clinical investigation. In addition to their patient reported outcome measures (PROMs), self- reported measures of physical activity levels and gait analysis were undertaken both pre- operatively (1.5 weeks) and post operatively (52 weeks). This data was then compared to data from a group of 43 age gender and BMI matched group of healthy controls. Kinetics and kinematics were recorded using an instrumented treadmill and 3D Motion Capture. Statistical parametric mapping was used for analysis. cHRA improved the median Harris Hip Score from 63 to 100, Oxford Hip score from 27 to 48 and the MET from 5.7 to 10.3. cHRA improved top walking speed (5.75km vs 7.27km/hr), achieved a more symmetrical ground reaction force profile, (Symmetry Index value: 10.6% vs 0.9%) and increased hip range of motion (ROM) (31.7° vs 45.9°). Postoperative data was not statistically distinguishable from the healthy controls in any domain. This gait study sought to document the function of a novel ceramic hip resurfacing, using those features of gait commonly used to describe the shortcomings of hip arthroplasty. These features were captured before and 12 months following surgery. Preoperatively the gait patterns were typical for OA patients, while at 1 year postoperatively, this selected group of patients had gait patterns that were hard to distinguish from healthy controls despite an extended posterior approach. Applications for regulatory approval have been submitted.
Aims. This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Methods. Using a life-cycle assessment approach, we conducted a
Developmental dysplasia of the hip (DDH) is defined as abnormal, pathological relations between the elements of the hip joint, resulting from disorders of its development. Since 1984, periacetabular bernese osteotomy (PAO) has been a method of treating DDH. The aim of this study was to evaluate the results of the PAO in persistent deformity from childhood and primary late dysplasia in adolescents and adults. Patients were divided into four groups: Improvement in radiological parameters and statistical significance were achieved in all measurements in all patients. The greatest improvement was achieved in: CEA − 19˚ in Group B, Medialization − 3mm in Group C, Distalization − 6mm in Group B, FHC − 17% in Group B, Ilio-ischial angle − 5˚ in Group B. The greatest correction of radiological parameters was obtained in children operated in childhood. Surgical treatment of DDH in childhood worsens the operating conditions in adolescents and adults due to scars, adhesions and altered bone anatomy but leaves the need for less deformity correction. The surgical treatment of DDH in childhood has a beneficial effect on the final outcome of the treatment of patients undergoing PAO surgery in adolescents and young adults.
We prospectively assessed the efficacy of a ceramic-on-metal
(CoM) hip bearing with uncemented acetabular and femoral components
in which cobalt–chrome acetabular liners and alumina ceramic heads
were used. The cohort comprised 94 total hip replacements (THRs) in 83 patients
(38 women and 45 men) with a mean age of 58 years (42 to 70). Minimum
follow-up was two years. All patients had pre- and post-operative
assessment using the Western Ontario and McMaster Universities osteoarthritis
index (WOMAC), Oxford hip score and Short-Form 12 scores. All showed
a statistically significant improvement from three months post-operatively
onwards (all p <
0.001). After two years whole blood metal ion levels were measured and
chromosomal analysis was performed. The levels of all metal ions
were elevated except vanadium. Levels of chromium, cobalt, molybdenum
and titanium were significantly higher in patients who underwent
bilateral THR compared with those undergoing unilateral THR (p <
0.001).
Chromosomal analysis demonstrated both structural and aneuploidy
mutations. There were significantly more breaks and losses than
in the normal population (p <
0.001). There was no significant
difference in chromosomal aberration between those undergoing unilateral
and bilateral procedures (all analyses p ≥ 0.62). The use of a CoM THR is effective clinically in the short-term,
with no concerns, but the significance of high metal ion levels
and chromosomal aberrations in the long-term remains unclear. Cite this article:
We describe the findings at six years in an ongoing prospective clinicoradiological and metal ion study in a cohort of 26 consecutive male patients with unilateral Birmingham Hip Resurfacing arthroplasties with one of two femoral head sizes (50 mm and 54 mm). Their mean age was 52.9 years (29 to 67). We have previously shown an early increase in the 24-hour urinary excretion of metal ions, reaching a peak at six months (cobalt) and one year (chromium) after operation. Subsequently there is a decreasing trend in excretion of both cobalt and chromium. The levels of cobalt and chromium in whole blood also show a significant increase at one year, followed by a decreasing trend until the sixth year.
Modular dual-mobility constructs reduce the risk of dislocation after total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chrome (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the mid-term serum Co and Cr levels after modular dual-mobilities used in revision and complex primary THAs, and specifically included patients revised for ALTR. Serum Co and Cr levels were measured prospectively in 22 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. Mean age 64 years with 50% female. The mean follow-up was 4 years. Indications for modular dual-mobility were: periprosthetic joint infection treated with 2-stage exchange and subsequent reimplantation (n=8), ALTR revision (n=7), complex primary THA (n=6), and periprosthetic femoral fracture (n=1). Mean preoperative Co and Cr in patients revised for an ALTR were 29.7 µg/L and 21.5 µg/L, respectively.Introduction
Methods
Dual mobility cups (DMC) reduce the risk of dislocation in femoral neck fractures (FNF). Direct anterior approach (DAA), historically promoted for better stability, has been developed in recent years for better functional results. The aim of this study was to compare the early functional results of DMC in FNF by DAA versus posterolateral approach (PLA). A
Refobacin Bone Cement R and Palacos Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.Aims
Methods
Cross linked polyethylene (XLPE) has gained popularity as a bearing surface of choice for younger patients despite only medium term results being available for wear rates. Concern remains regarding the long-term stability and durability of these materials. In order to address these issues we present the longest radiological and clinical follow-up of XLPE. Since 1986, we have prospectively studied a group of 17 patients (19 hips) that underwent a cemented Charnley low friction arthroplasty using a combination of 22.225mm alumina ceramic femoral head, a modified Charnley flanged stem and a chemically cross-linked polyethylene cup. We now report the 28 year clinical and radiological results.Introduction
Patients/Materials & Methods
Introduction. Within the field of arthroplasty, the use of patient-reported outcome measures (PROMs) is becoming increasingly ubiquitous in an effort to employ more patient-centered methods of evaluating success. PROMs may be used to assess general health, joint-specific pain or function, or mental health. General and joint-specific questionnaires are most often used in arthroplasty research, but the relationship between arthroplasty and mental health is less well understood. Furthermore, longitudinal reports of PROM changes after arthroplasty are lacking in the literature. Our primary aim was to quantify the improvement in general, joint-specific, and mental health PROMs following total hip arthroplasty (THA) as well as the extent of any deterioration through the 7 years follow-up. Our secondary aim was to identify predictors of clinically significant PROM decline. Methods. A total of 864 patients from 17 centers across 8 countries were enrolled into a
We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years, analysing polyethylene wear and osteolysis. 82 hips implanted between 1992 and 1995 were prospectively evaluated. Mean follow-up was 20.6 years (18–23). A hemispherical porous-coated cup matched to a proximally hydroxyapatite-coated anatomic stem. A 28mm PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position, eventual loosening and osteolysis were recorded over time. Penetration of the head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter. Six cups were revised due to wear and four cups because of late dislocation. All stems showed osseointegration and all cups appeared radiographically well-fixed. Six unrevised hips showed osteolysis on the acetabular side and two hips on the proximal femur. Creep at one year was 0.30±0.23 mm. Mean total femoral head penetration was 1.23mm at ten years, 1.52mm at 15 years and 1.92mm at 23 years. Overall mean wear was 0.12±0.1 mm/year and 0.09±0.06 mm/year after the creep period. Mean wear was 0.08±0.06 mm/year in hips without osteolysis and 0.14±0.03 mm/year in hips revised or hips with osteolysis (p<0.001). Although continued durable fixation can be observed with porous-coated cups and proximally hydroxyapatite-coated anatomic stems, true wear continues to increase at a constant level over time. PE wear remains as the main reason for osteolysis and revision surgery in uncemented THR after twenty years.
The aim of this study was to evaluate the ten-year
clinical and functional outcome of hip resurfacing and to compare it
with that of cementless hip arthroplasty in patients under the age
of 55 years. Between 1999 and 2002, 80 patients were enrolled into the study:
24 were randomised (11 to hip resurfacing, 13 to total hip arthroplasty),
18 refused hip resurfacing and chose cementless total hip arthroplasty
with a 32 mm bearing, and 38 insisted on resurfacing. The mean follow-up
for all patients was 12.1 years (10 to 14). Patients were assessed clinically and radiologically at one year,
five years and ten years. Outcome measures included EuroQol EQ5D,
Oxford, Harris hip, University of California Los Angeles and University
College Hospital functional scores. No differences were seen between the two groups in the Oxford
or Harris hip scores or in the quality of life scores. Despite a
similar aspiration to activity pre-operatively, a higher proportion
of patients with a hip resurfacing were running and involved in
sport and heavy manual labour after ten years. We found significantly higher function scores in patients who
had undergone hip resurfacing than in those with a cementless hip
arthroplasty at ten years. This suggests a functional advantage
for hip resurfacing. There were no other attendant problems. Cite this article:
The changes in sagittal spino-pelvic balance from standing to sitting in patients with end-stage osteoarthritis (OA) of the hip remain poorly characterized. Our aim was to 1) investigate the contribution of sagittal spino-pelvic movement and hip flexion when moving from a standing to sitting posture in patients with hip OA; 2) determine the proportion of OA-patients with stiff, normal or hypermobile spino-pelvic mobility and 3) identify radiographic parameters correlating with spino-pelvic mobility. This prospective diagnostic cohort study followed 116 consecutive patients with end-stage osteoarthritis awaiting THR. All patients underwent preoperative standardized radiographs (lateral view) of the lumbar spine, pelvis and proximal femur using EOS© in standing position and with femurs parallel to the floor in order to achieve a 90°-seated position. Radiographic measurements performed included lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), pelvic incidence (PI) and pelvic-femoral-angle (PFA). The difference in PT between standing and seated allowed for patient classification based on spino-pelvic mobility into stiff (<±10°), normal (±10–30°), or hypermobile (>±30°).Introduction
Methods
No single test has demonstrated absolute accuracy in the diagnosis of periprosthetic joint infection (PJI). Leukocyte esterase (LE) is a synovial marker that has proven utility in the diagnosis of PJI. The purpose of this
Aims. Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in hip arthroplasty PJI patients. Methods. This was a
In this study, we examined the impact of dual-mobility (DM) versus fixed-bearing (FB) implants on outcomes following total hip arthroplasty (THA), a common and successful operation. We examined all-cause revision, revision due to dislocation, postoperative complications and functional scores in patients undergoing primary and revision THA. A systematic review was performed according to PRISMA guidelines, and was registered in PROSPERO (ID CRD42023403736). The Cochrane Library, Embase, MEDLINE, Web of Science, and Scopus were searched from inception to 12th March 2023. Eligible studies underwent meta-analysis and methodological assessment using the ROBINS-I tool. Data were pooled using a random-effects maximum-likelihood model. Eight comparative, non-randomised studies involving 2,810 DM implants and 3,188 FB implants were included. In primary THA, the difference in all-cause revision was imprecise (OR 0.82, 95% CI 0.25–2.72), whilst the DM cohort had a statistically significant benefit in revision due to dislocation (OR 0.08, 95% CI 0.02–0.28). In revision THA, the DM cohort showed significant benefit in all-cause revision (OR 0.57, 95% CI 0.31–1.05) and revision due to dislocation (OR 0.14, 95% CI 0.04–0.53). DM implants were associated with a lower incidence of implant dislocation and infection. Functional outcome analysis was limited due to underreporting. No intraprosthetic dislocations were observed. The results suggest that contemporary DM designs may be advantageous in reducing the risk of all-cause revision, revision due to dislocation, and postoperative complication incidence at mid-term follow-up. Further high-quality
We report the impact of implementing a new short-stay hip and knee arthroplasty pathway in a National Health Service (NHS) hospital. This was enacted due to existing concerns with a long length of stay (LOS) and reduced elective operating capacity each winter due to emergency bed pressures. The overnight introduction of this pathway was aimed to reduce LOS, alleviate bed pressures, minimise readmission rates and generate financial savings, all combining to facilitate full elective activity during the winter. We conducted a
Pelvic discontinuity (PD) is a detrimental complication following total hip arthroplasty (THA). The aim of this study was to assess the clinical and radiological results of patients with PD who were revised using a custom-made triflange acetabular component (CTAC). This is a single centre
Traditional mechanical debridement can only remove visibly infected tissue and is unable to completely clear all the biofilm that hides within muscle crevices and nerves. This study aims to determine the results of single-stage revision using noncontact low frequency ultrasonic debridement in treating chronic periprosthetic joint infections (PJI). A
The aims were to assess whether preoperative joint-specific function (JSF) and health-related quality of life (HRQoL) were associated with level of clinical frailty in patients waiting for a primary total hip arthroplasty (THA) or knee arthroplasty (KA). Patients waiting for a THA (n=100) or KA (n=100) for more than six months were prospectively recruited from the study centre. Overall, 162 patients responded to the questionnaire (81 THA; 81 KA). Patient demographics, Oxford score, EuroQol five dimension (EQ-5D) score, EuroQol visual analogue score (EQ-VAS), Rockwood Clinical Frailty Score (CFS), and time spent on the waiting list were collected. There was a significant correlation between CFS and the Oxford score (THA r=ˆ’0.838; p<0.001, KA r=ˆ’0.867; p<0.001), EQ-5D index (THA r=ˆ’0.663, p<0.001; KA r=ˆ’0.681; p< 0.001), and EQ-VAS (THA r=ˆ’0.414; p<0.001, KA r=ˆ’0.386; p<0.001). Confounding variables (demographics and waiting time) where adjusted for using multiple regression analysis. For each 8.5 (THA, 95% CI 7.1 to 10.0; p<0.001) and 9.9 (KA, 95% CI 8.4 to 11.4; p<0.001) point change in the Oxford score, there was an associated change in level of the CFS. For each 0.16 (THA, 95% CI 0.10 to 0.22; p<0.001) and 0.20 (KA, 95% CI 0.12 to 0.27; p<0.001) utility change in EQ-5D, there was an associated change in level of the CFS. EQ-VAS (THA, B=ˆ’11.5; p<0.001, KA B=ˆ’7.9; p=0.005) was also associated with CFS. JSF and HRQoL in patients awaiting THA or KA for more than six months, were independently associated with level of clinical frailty. With further