Advertisement for orthosearch.org.uk
Results 1 - 20 of 264
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 41 - 41
19 Aug 2024
Cobb J Maslivec A Clarke S Halewood C Wozencroft R
Full Access

A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in an MHRA-approved clinical investigation to provide a non metallic alternative hip resurfacing product. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures both before and 12 months following surgery in comparison with age and gender matched healthy controls.

Eighty-two unilateral cHRA patients consented to this study as part of a larger prospective, non-randomised, clinical investigation. In addition to their patient reported outcome measures (PROMs), self- reported measures of physical activity levels and gait analysis were undertaken both pre- operatively (1.5 weeks) and post operatively (52 weeks). This data was then compared to data from a group of 43 age gender and BMI matched group of healthy controls. Kinetics and kinematics were recorded using an instrumented treadmill and 3D Motion Capture. Statistical parametric mapping was used for analysis.

cHRA improved the median Harris Hip Score from 63 to 100, Oxford Hip score from 27 to 48 and the MET from 5.7 to 10.3. cHRA improved top walking speed (5.75km vs 7.27km/hr), achieved a more symmetrical ground reaction force profile, (Symmetry Index value: 10.6% vs 0.9%) and increased hip range of motion (ROM) (31.7° vs 45.9°). Postoperative data was not statistically distinguishable from the healthy controls in any domain.

This gait study sought to document the function of a novel ceramic hip resurfacing, using those features of gait commonly used to describe the shortcomings of hip arthroplasty. These features were captured before and 12 months following surgery. Preoperatively the gait patterns were typical for OA patients, while at 1 year postoperatively, this selected group of patients had gait patterns that were hard to distinguish from healthy controls despite an extended posterior approach. Applications for regulatory approval have been submitted.


Bone & Joint Open
Vol. 5, Issue 9 | Pages 742 - 748
10 Sep 2024
Kodumuri P Joshi P Malek I

Aims. This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Methods. Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries. Results. The carbon footprint of an uncemented THA was estimated at 100.02 kg CO2e, with a marginal increase to 104.89 kg CO2e for hybrid THA. Key contributors were consumables in the operating theatre (21%), waste generation (22%), and scope 2 emissions (38%). The study identified opportunities for reducing emissions, including instrument rationalization, transitioning to LED lighting, and improving waste-recycling practices. Conclusion. This study sheds light on the substantial carbon footprint associated with THA. Actionable strategies for reducing emissions were identified, emphasizing the need for sustainable practices in orthopaedic surgery. The findings prompt a critical discussion on the environmental impact of single-use versus reusable items in the operating theatre, challenging traditional norms to make more environmentally responsible choices. Cite this article: Bone Jt Open 2024;5(9):742–748


Developmental dysplasia of the hip (DDH) is defined as abnormal, pathological relations between the elements of the hip joint, resulting from disorders of its development. Since 1984, periacetabular bernese osteotomy (PAO) has been a method of treating DDH. The aim of this study was to evaluate the results of the PAO in persistent deformity from childhood and primary late dysplasia in adolescents and adults.

Patients were divided into four groups: A - adolescent patients not operated of DDH in childhood, B – adolescent patient after a surgical treatment of DDH in childhood, C - adults with hip dysplasia not previously operated, D - control group. Radiological evaluation of standard AP view of hip joints was performed before and after the surgery and included parameters: Wiberg angle (CEA), femoral head cover (FHC), medialization, distalisation, the ilio-ischial angle.

Improvement in radiological parameters and statistical significance were achieved in all measurements in all patients. The greatest improvement was achieved in: CEA − 19˚ in Group B, Medialization − 3mm in Group C, Distalization − 6mm in Group B, FHC − 17% in Group B, Ilio-ischial angle − 5˚ in Group B.

The greatest correction of radiological parameters was obtained in children operated in childhood. Surgical treatment of DDH in childhood worsens the operating conditions in adolescents and adults due to scars, adhesions and altered bone anatomy but leaves the need for less deformity correction. The surgical treatment of DDH in childhood has a beneficial effect on the final outcome of the treatment of patients undergoing PAO surgery in adolescents and young adults.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1040 - 1044
1 Aug 2013
Kazi HA Perera JR Gillott E Carroll FA Briggs TWR

We prospectively assessed the efficacy of a ceramic-on-metal (CoM) hip bearing with uncemented acetabular and femoral components in which cobalt­–chrome acetabular liners and alumina ceramic heads were used.

The cohort comprised 94 total hip replacements (THRs) in 83 patients (38 women and 45 men) with a mean age of 58 years (42 to 70). Minimum follow-up was two years. All patients had pre- and post-operative assessment using the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford hip score and Short-Form 12 scores. All showed a statistically significant improvement from three months post-operatively onwards (all p < 0.001).

After two years whole blood metal ion levels were measured and chromosomal analysis was performed. The levels of all metal ions were elevated except vanadium. Levels of chromium, cobalt, molybdenum and titanium were significantly higher in patients who underwent bilateral THR compared with those undergoing unilateral THR (p < 0.001). Chromosomal analysis demonstrated both structural and aneuploidy mutations. There were significantly more breaks and losses than in the normal population (p < 0.001). There was no significant difference in chromosomal aberration between those undergoing unilateral and bilateral procedures (all analyses p ≥ 0.62).

The use of a CoM THR is effective clinically in the short-term, with no concerns, but the significance of high metal ion levels and chromosomal aberrations in the long-term remains unclear.

Cite this article: Bone Joint J 2013;95-B:1040–44.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 176 - 179
1 Feb 2009
Daniel J Ziaee H Pradhan C McMinn DJW

We describe the findings at six years in an ongoing prospective clinicoradiological and metal ion study in a cohort of 26 consecutive male patients with unilateral Birmingham Hip Resurfacing arthroplasties with one of two femoral head sizes (50 mm and 54 mm). Their mean age was 52.9 years (29 to 67). We have previously shown an early increase in the 24-hour urinary excretion of metal ions, reaching a peak at six months (cobalt) and one year (chromium) after operation. Subsequently there is a decreasing trend in excretion of both cobalt and chromium. The levels of cobalt and chromium in whole blood also show a significant increase at one year, followed by a decreasing trend until the sixth year.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 18 - 18
1 Oct 2018
Chalmers BP Mangold DG Hanssen AD Pagnano MW Trousdale RT Abdel MP
Full Access

Introduction

Modular dual-mobility constructs reduce the risk of dislocation after total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chrome (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the mid-term serum Co and Cr levels after modular dual-mobilities used in revision and complex primary THAs, and specifically included patients revised for ALTR.

Methods

Serum Co and Cr levels were measured prospectively in 22 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. Mean age 64 years with 50% female. The mean follow-up was 4 years. Indications for modular dual-mobility were: periprosthetic joint infection treated with 2-stage exchange and subsequent reimplantation (n=8), ALTR revision (n=7), complex primary THA (n=6), and periprosthetic femoral fracture (n=1). Mean preoperative Co and Cr in patients revised for an ALTR were 29.7 µg/L and 21.5 µg/L, respectively.


Dual mobility cups (DMC) reduce the risk of dislocation in femoral neck fractures (FNF). Direct anterior approach (DAA), historically promoted for better stability, has been developed in recent years for better functional results. The aim of this study was to compare the early functional results of DMC in FNF by DAA versus posterolateral approach (PLA). A prospective study was conducted on a continuous series of patients who received DMC for FNF by DAA or PLA. The primary endpoint was Harris Hip Score and Parker score assessed at the first follow-up visit. Intraoperative complications were collected during hospitalization. One year clinical results and all cause revision rate were also collected. Radiographic data of cup positioning and limb length were evaluated. Fifty-two patients were included in the DAA group and 54 in the PLA group. Two patients were lost to follow-up. The mean age was 72.8 years. There was no significant difference in HHS or Parker score at 3 and 12 months follow up (p=0.6, p= 0.75). DAA was associated with more intraoperative complications with 4 fractures and 1 femoral nerve deficit (p=0.018). There were 3 revisions in the DAA group (1 infection, 1 dislocation, 1 peri prosthetic fracture) and 1 in the PLA group (infection), which was not statistically significant (p=0.34). Cup anteversion was 6° greater and inclination 9° lesser in DAA group (p=0.028, p<0.01). Results suggest that DAA does not provide any early functional benefit in THA-DMC for FNF compared to PLA. It could lead to more intraoperative complications and a higher revision rate. DAA requires an experienced surgeon and careful patient selection


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 435 - 441
1 May 2024
Angelomenos V Mohaddes M Kärrholm J Malchau H Shareghi B Itayem R

Aims

Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures.

Methods

Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 43 - 43
1 Nov 2015
Rajpura A Wroblewski B Siney P Board T Jones HW
Full Access

Introduction

Cross linked polyethylene (XLPE) has gained popularity as a bearing surface of choice for younger patients despite only medium term results being available for wear rates. Concern remains regarding the long-term stability and durability of these materials. In order to address these issues we present the longest radiological and clinical follow-up of XLPE.

Patients/Materials & Methods

Since 1986, we have prospectively studied a group of 17 patients (19 hips) that underwent a cemented Charnley low friction arthroplasty using a combination of 22.225mm alumina ceramic femoral head, a modified Charnley flanged stem and a chemically cross-linked polyethylene cup. We now report the 28 year clinical and radiological results.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 48 - 48
1 Oct 2018
Galea VP Connelly JW Matuszak SJ Rojanasopondist P Bragdon CR Huddleston JI Rubash HE Malchau H
Full Access

Introduction. Within the field of arthroplasty, the use of patient-reported outcome measures (PROMs) is becoming increasingly ubiquitous in an effort to employ more patient-centered methods of evaluating success. PROMs may be used to assess general health, joint-specific pain or function, or mental health. General and joint-specific questionnaires are most often used in arthroplasty research, but the relationship between arthroplasty and mental health is less well understood. Furthermore, longitudinal reports of PROM changes after arthroplasty are lacking in the literature. Our primary aim was to quantify the improvement in general, joint-specific, and mental health PROMs following total hip arthroplasty (THA) as well as the extent of any deterioration through the 7 years follow-up. Our secondary aim was to identify predictors of clinically significant PROM decline. Methods. A total of 864 patients from 17 centers across 8 countries were enrolled into a prospective study. Patients were treated with components from a single manufacturer, which have been shown to be well-functioning in other studies. Patients completed a battery of PROMs preoperatively, and at one, three, five, and seven years post-THA. Changes in PROMs between study visits were assessed via paired tests. Postoperative trends for each PROM were determined for each subject by the slope of the best-fit line of the four postoperative data points. Significant PROM deterioration was defined as one literature-defined minimum clinically important difference over 5-years. Binary logistic regressions were used to identify independent predictors of significant decline in the EuroQol (EQ-5D) visual analogue scale (VAS) for Health State, 36-Item Short Form Survey (SF-36) physical composite summary (PCS), and SF-36 mental composite summary (MCS). Results. A total of 417 completed all study visits (70% of currently eligible). All patients experienced significant improvements in all hip-specific and most general health PROMs 1-year post-THA (all p ≤ 0.002). In addition, a significant number of patients experienced a reduction in anxiety/depression following THA (p < 0.001). Hip specific PROMs remained excellent through 7-years, but most general and mental health PROs declined by the 7-year visit. A total of 133 patients (32%) experienced significant deterioration in the EQ-5D Health State. Age greater than 60 years (odds ratio (OR) = 1.9; p = 0.002) and obesity (OR = 1.7; p = 0.036) were independently predictive of EQ-5D Health State decline. A total of 58 patients (14%) experienced significant deterioration in the SF-36 PCS. Independent predictors of significant SF-36 PCS decline were lower preoperative SF-36 MCS (OR = 0.9; p = 0.002) and obesity (OR = 2.6; p = 0.009). A total of 229 patients (55%) experienced significant deterioration in the SF-36 MCS. Age greater than 60 years was predictive of significant SF-36 MCS decline (OR = 1.8; p = 0.017). Conclusion. For most patients, hip-specific PROMs will remain near the 1-year level through 7-years follow-up. Except for those with lower preoperative mental health or with obesity, gauging a patient's hip-related status at 1-year is sufficient to extrapolate their trajectory through midterm follow-up. Some patients experience mental health improvements following THA, but the majority experience a decline within 7 years of their surgery, especially older patients. Similarly, age-related decreases in general health are expected, following initial improvement 1 year after THA. Obese patients are also more likely to experience general health deterioration post-THA. By addressing the modifiable risk factors for PROM decline, the positive effects of THA may be better sustained over time


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 34 - 34
1 Aug 2018
García-Rey E García-Cimbrelo E Cordero-Ampuero J
Full Access

We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) after twenty years, analysing polyethylene wear and osteolysis.

82 hips implanted between 1992 and 1995 were prospectively evaluated. Mean follow-up was 20.6 years (18–23). A hemispherical porous-coated cup matched to a proximally hydroxyapatite-coated anatomic stem. A 28mm PE liner, sterilised by gamma irradiation in air, was used in all hips. Radiological position, eventual loosening and osteolysis were recorded over time. Penetration of the head into the liner was measured by the Roentgen Monographic Analysis (ROMAN) Tool at 6 weeks, 6 months, one year and yearly thereafter.

Six cups were revised due to wear and four cups because of late dislocation. All stems showed osseointegration and all cups appeared radiographically well-fixed. Six unrevised hips showed osteolysis on the acetabular side and two hips on the proximal femur. Creep at one year was 0.30±0.23 mm. Mean total femoral head penetration was 1.23mm at ten years, 1.52mm at 15 years and 1.92mm at 23 years. Overall mean wear was 0.12±0.1 mm/year and 0.09±0.06 mm/year after the creep period. Mean wear was 0.08±0.06 mm/year in hips without osteolysis and 0.14±0.03 mm/year in hips revised or hips with osteolysis (p<0.001).

Although continued durable fixation can be observed with porous-coated cups and proximally hydroxyapatite-coated anatomic stems, true wear continues to increase at a constant level over time. PE wear remains as the main reason for osteolysis and revision surgery in uncemented THR after twenty years.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 617 - 622
1 May 2015
Haddad FS Konan S Tahmassebi J

The aim of this study was to evaluate the ten-year clinical and functional outcome of hip resurfacing and to compare it with that of cementless hip arthroplasty in patients under the age of 55 years.

Between 1999 and 2002, 80 patients were enrolled into the study: 24 were randomised (11 to hip resurfacing, 13 to total hip arthroplasty), 18 refused hip resurfacing and chose cementless total hip arthroplasty with a 32 mm bearing, and 38 insisted on resurfacing. The mean follow-up for all patients was 12.1 years (10 to 14).

Patients were assessed clinically and radiologically at one year, five years and ten years. Outcome measures included EuroQol EQ5D, Oxford, Harris hip, University of California Los Angeles and University College Hospital functional scores.

No differences were seen between the two groups in the Oxford or Harris hip scores or in the quality of life scores. Despite a similar aspiration to activity pre-operatively, a higher proportion of patients with a hip resurfacing were running and involved in sport and heavy manual labour after ten years.

We found significantly higher function scores in patients who had undergone hip resurfacing than in those with a cementless hip arthroplasty at ten years. This suggests a functional advantage for hip resurfacing. There were no other attendant problems.

Cite this article: Bone Joint J 2015; 97-B:617–22.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 27 - 27
1 May 2018
Innmann M Merle C Gotterbarm T Beaulé P Grammatopoulos G
Full Access

Introduction

The changes in sagittal spino-pelvic balance from standing to sitting in patients with end-stage osteoarthritis (OA) of the hip remain poorly characterized. Our aim was to 1) investigate the contribution of sagittal spino-pelvic movement and hip flexion when moving from a standing to sitting posture in patients with hip OA; 2) determine the proportion of OA-patients with stiff, normal or hypermobile spino-pelvic mobility and 3) identify radiographic parameters correlating with spino-pelvic mobility.

Methods

This prospective diagnostic cohort study followed 116 consecutive patients with end-stage osteoarthritis awaiting THR. All patients underwent preoperative standardized radiographs (lateral view) of the lumbar spine, pelvis and proximal femur using EOS© in standing position and with femurs parallel to the floor in order to achieve a 90°-seated position. Radiographic measurements performed included lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), pelvic incidence (PI) and pelvic-femoral-angle (PFA). The difference in PT between standing and seated allowed for patient classification based on spino-pelvic mobility into stiff (<±10°), normal (±10–30°), or hypermobile (>±30°).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 83 - 83
19 Aug 2024
Tarabichi S Lizcano JD Abe EA Olin B Courtney PM Parvizi J
Full Access

No single test has demonstrated absolute accuracy in the diagnosis of periprosthetic joint infection (PJI). Leukocyte esterase (LE) is a synovial marker that has proven utility in the diagnosis of PJI. The purpose of this prospective study was to (1) identify the optimal cutoff for the use of LE in the diagnosis of PJI and (2) determine whether performance of the LE strip test varied by infecting organism. This prospective study enrolled 1,015 patients undergoing hip or knee revision arthroplasty at a single institution from 2009 to September 2021. PJI was defined using a modified version of 2018 International Consensus Meeting (ICM) criteria that excluded LE when calculating the ICM score. Receiver operating characteristic curves were used to assess the utility of the LE strip test in the diagnosis of PJI. 973 patients were included in the analyses. 246 (25.4%) were classified as ICM-positive and 727 (74.6%) were classified as ICM-negative. An LE cutoff of “1+” (AUC 0.819, sensitivity 73.2%, specificity 90.6%) had superior accuracy to an LE cutoff of “2+” (AUC 0.713, sensitivity 43.9%, specificity 98.8%) in the overall diagnosis of PJI (p<0.001). When stratifying by organism type, an LE cutoff of “1+” had the best diagnostic utility for PJI caused by methicillin resistant Staphylococcus aureus (AUC 0.888, sensitivity 87.0%, n=23) followed by Streptococcus spp. (AUC 0.882, sensitivity 85.7%, n=28), coagulase negative Staphylococci (AUC 0.836, sensitivity 76.6%, n=47), methicillin sensitive Staphylococcus aureus (AUC 0.806, sensitivity 70.6%, n=34), culture negative (AUC 0.793, sensitivity 67.9%, n=56), and gram negative rods (AUC 0.763, sensitivity 61.9%, n=21). To our knowledge, this is the largest study evaluating the utility of the LE strip test in the diagnosis of PJI. Based on our findings, it appears that a “1+” cutoff has higher diagnostic utility than a cutoff of “2+”


Bone & Joint Open
Vol. 5, Issue 6 | Pages 479 - 488
6 Jun 2024
Paksoy A Meller S Schwotzer F Moroder P Trampuz A Imiolczyk J Perka C Hackl M Plachel F Akgün D

Aims. Current diagnostic tools are not always able to effectively identify periprosthetic joint infections (PJIs). Recent studies suggest that circulating microRNAs (miRNAs) undergo changes under pathological conditions such as infection. The aim of this study was to analyze miRNA expression in hip arthroplasty PJI patients. Methods. This was a prospective pilot study, including 24 patients divided into three groups, with eight patients each undergoing revision of their hip arthroplasty due to aseptic reasons, and low- and high-grade PJI, respectively. The number of intraoperative samples and the incidence of positive cultures were recorded for each patient. Additionally, venous blood samples and periarticular tissue samples were collected from each patient to determine miRNA expressions between the groups. MiRNA screening was performed by small RNA-sequencing using the miRNA next generation sequencing (NGS) discovery (miND) pipeline. Results. Overall, several miRNAs in plasma and tissue were identified to be progressively deregulated according to ongoing PJI. When comparing the plasma samples, patients with a high-grade infection showed significantly higher expression levels for hsa-miR-21-3p, hsa-miR-1290, and hsa-miR-4488, and lower expression levels for hsa-miR-130a-3p and hsa-miR-451a compared to the aseptic group. Furthermore, the high-grade group showed a significantly higher regulated expression level of hsa-miR-1260a and lower expression levels for hsa-miR-26a-5p, hsa-miR-26b-5p, hsa-miR-148b-5p, hsa-miR-301a-3p, hsa-miR-451a, and hsa-miR-454-3p compared to the low-grade group. No significant differences were found between the low-grade and aseptic groups. When comparing the tissue samples, the high-grade group showed significantly higher expression levels for 23 different miRNAs and lower expression levels for hsa-miR-2110 and hsa-miR-3200-3p compared to the aseptic group. No significant differences were found in miRNA expression between the high- and low-grade groups, as well as between the low-grade and aseptic groups. Conclusion. With this prospective pilot study, we were able to identify a circulating miRNA signature correlating with high-grade PJI compared to aseptic patients undergoing hip arthroplasty revision. Our data contribute to establishing miRNA signatures as potential novel diagnostic and prognostic biomarkers for PJI. Cite this article: Bone Jt Open 2024;5(6):479–488


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 39 - 39
2 May 2024
Saroha S Raheman F Jaiswal P Patel A
Full Access

In this study, we examined the impact of dual-mobility (DM) versus fixed-bearing (FB) implants on outcomes following total hip arthroplasty (THA), a common and successful operation. We examined all-cause revision, revision due to dislocation, postoperative complications and functional scores in patients undergoing primary and revision THA. A systematic review was performed according to PRISMA guidelines, and was registered in PROSPERO (ID CRD42023403736). The Cochrane Library, Embase, MEDLINE, Web of Science, and Scopus were searched from inception to 12th March 2023. Eligible studies underwent meta-analysis and methodological assessment using the ROBINS-I tool. Data were pooled using a random-effects maximum-likelihood model. Eight comparative, non-randomised studies involving 2,810 DM implants and 3,188 FB implants were included. In primary THA, the difference in all-cause revision was imprecise (OR 0.82, 95% CI 0.25–2.72), whilst the DM cohort had a statistically significant benefit in revision due to dislocation (OR 0.08, 95% CI 0.02–0.28). In revision THA, the DM cohort showed significant benefit in all-cause revision (OR 0.57, 95% CI 0.31–1.05) and revision due to dislocation (OR 0.14, 95% CI 0.04–0.53). DM implants were associated with a lower incidence of implant dislocation and infection. Functional outcome analysis was limited due to underreporting. No intraprosthetic dislocations were observed. The results suggest that contemporary DM designs may be advantageous in reducing the risk of all-cause revision, revision due to dislocation, and postoperative complication incidence at mid-term follow-up. Further high-quality prospective studies are needed to evaluate the long-term performance of this design, especially in revision cases


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 97 - 97
19 Aug 2024
Ilo K Van Duren BH Higgins MA Manktelow ARJ Bloch BV
Full Access

We report the impact of implementing a new short-stay hip and knee arthroplasty pathway in a National Health Service (NHS) hospital. This was enacted due to existing concerns with a long length of stay (LOS) and reduced elective operating capacity each winter due to emergency bed pressures. The overnight introduction of this pathway was aimed to reduce LOS, alleviate bed pressures, minimise readmission rates and generate financial savings, all combining to facilitate full elective activity during the winter. We conducted a prospective study at a regional tertiary arthroplasty centre. The new pathway was introduced across the service overnight. It includes rigorous preoperative optimisation, specific anaesthetic protocols and uniform changes in surgical practice to allow a focus on early mobilization and discharge on the day of surgery where possible. Data collection spanned 17 months, including the initial six months post implementation of the short-stay pathway. LOS data was collected for the full period and data was compared pre- and post-implementation of the new pathway. Patient satisfaction and 30-day readmission data were also collected. There was an immediate and significant decrease in median LOS from 4 days pre-implementation to 1 day post-implementation. Patient satisfaction was high, and the 30-day readmission rate was unchanged (5.95%), with no readmissions directly related to decreased inpatient stay. Financial analyses revealed substantial cost savings due to reduced LOS and the elimination of routine post-operative blood tests, estimated at over £1.6m per year. Elective activity over winter was significantly higher (79%) than in the same time period in the previous year. An acute introduction of a carefully planned and coordinated short-stay hip and knee pathway is safe, cost-effective and popular with patients, but also contributes to increased efficiency in the delivery of elective healthcare in the context of increasing demand and financial constraints in the NHS


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 7 - 7
23 Jun 2023
van Hellemondt GG Faraj S de Windt T van Hooff M Spruit M
Full Access

Pelvic discontinuity (PD) is a detrimental complication following total hip arthroplasty (THA). The aim of this study was to assess the clinical and radiological results of patients with PD who were revised using a custom-made triflange acetabular component (CTAC). This is a single centre prospective study of patients with PD following THA who were treated with a CTAC. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Clinical and radiological complications, including reasons for revisions were registered. Trends over time are described and tested for significance and clinical relevance. 18 females with 22 CTACs were included with a mean age of 73.5 years (SD 7.7). There were significant improvements between baseline and final follow-up in HOOS (p<0.01), mOHS (p<0.01), EQ-5D-3L utility (p<0.01), EQ-5D-3L NRS (p<0.01), VAS pain rest (p<0.01), and VAS pain activity (p<0.01). A minimal clinically important improvement in mOHS and the HOOS was observed in 16 patients (73%) and 14 patients (64%), respectively. Definite healing of the PD was observed in 19 hips (86%). Complications included six cases with broken screws (27%), four cases (18%) with bony fractures, and one case (4.5%) with sciatic nerve paresthesia. One patient with concurrent bilateral PD had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage. This is the first prospective assessment in clinical outcome of patients with PD who were treated with a CTAC. We have demonstrated that CTAC in patients with THA acetabular loosening and PD can result in stable constructs with no mechanical failures. Moreover, clinically relevant improvements in health-related quality of life at two years’ follow-up was observed


Traditional mechanical debridement can only remove visibly infected tissue and is unable to completely clear all the biofilm that hides within muscle crevices and nerves. This study aims to determine the results of single-stage revision using noncontact low frequency ultrasonic debridement in treating chronic periprosthetic joint infections (PJI). A prospective study of consecutive patients requiring single-stage revision for chronic PJI was performed since August 2021. After mechanical debridement, an 8‑mm handheld non‑contact low‑frequency ultrasound probe was used for ultrasonic debridement at a frequency of (25±5) kHz and power of 90% for 5 minutes. Each ultrasound lasted 10 seconds with 3‑seconds intervals. The probe was repeatedly sonicated among all soft tissue and bsingle interface. The distal femoral canal and the posterior capsule of the knee were fully sonicated with a special right‑angle probe. Chemical debridement was then performed to irrigation the whole operative area. Recurrence of infection, culture results and number of colonies 24 hours after ultrasonic debridement were recorded. A total of 45 patients (25 hips and 20 knees) were included and 43 of them (95.6%) were free of infection at a mean follow-up time of 29 months (24 to 33). There were no intraoperative complications related to ultrasonic debridement (neurovascular and muscle injury, poor wound healing and fat liquefaction). The culture‑positive rate of wound liquid before ultrasonic debridement was 40.0% (18/45), which significantly increased to 75.6% (34/45) after ultrasonic debridement (P=0.001). The median number of colonies 24 hours after ultrasonic debridement was 2372 CFU/ml (310 to 4340 CFU/ml), which was significantly higher than that before debridement (307 CFU/ml; 10 to 980 CFU/ml) (P=0.000). Single-stage revision with non‑contact low‑frequency ultrasonic debridement can fully expose bacteria within biofilm, increase the efficacy of chemical debridement and lead to a favorable short‑term outcome without related complications


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 52 - 52
2 May 2024
Bayram JM Wickramasinghe N Scott CE Clement ND
Full Access

The aims were to assess whether preoperative joint-specific function (JSF) and health-related quality of life (HRQoL) were associated with level of clinical frailty in patients waiting for a primary total hip arthroplasty (THA) or knee arthroplasty (KA). Patients waiting for a THA (n=100) or KA (n=100) for more than six months were prospectively recruited from the study centre. Overall, 162 patients responded to the questionnaire (81 THA; 81 KA). Patient demographics, Oxford score, EuroQol five dimension (EQ-5D) score, EuroQol visual analogue score (EQ-VAS), Rockwood Clinical Frailty Score (CFS), and time spent on the waiting list were collected. There was a significant correlation between CFS and the Oxford score (THA r=ˆ’0.838; p<0.001, KA r=ˆ’0.867; p<0.001), EQ-5D index (THA r=ˆ’0.663, p<0.001; KA r=ˆ’0.681; p< 0.001), and EQ-VAS (THA r=ˆ’0.414; p<0.001, KA r=ˆ’0.386; p<0.001). Confounding variables (demographics and waiting time) where adjusted for using multiple regression analysis. For each 8.5 (THA, 95% CI 7.1 to 10.0; p<0.001) and 9.9 (KA, 95% CI 8.4 to 11.4; p<0.001) point change in the Oxford score, there was an associated change in level of the CFS. For each 0.16 (THA, 95% CI 0.10 to 0.22; p<0.001) and 0.20 (KA, 95% CI 0.12 to 0.27; p<0.001) utility change in EQ-5D, there was an associated change in level of the CFS. EQ-VAS (THA, B=ˆ’11.5; p<0.001, KA B=ˆ’7.9; p=0.005) was also associated with CFS. JSF and HRQoL in patients awaiting THA or KA for more than six months, were independently associated with level of clinical frailty. With further prospective studies, clinical frailty may prove to be a useful metric to assist in the prioritization of arthroplasty waiting lists