Introduction. The value of the
With the advent of digital radiology, our institution has introduced digital templating for preoperative planning of total hip arthroplasty (THA). Prior studies of the accuracy of digital templating had contradictory results. This study compares the accuracy of digital and analog templating for THA. Ninety patients were recruited. Sixty-eight patients had analog pre-operative templating while 22 patients had digital templating. A retrospective review of medical records obtained the sizes of hip implants inserted during THA and patient demographics. The templated hip sizes were compared with the actual hip implants inserted. Accuracies of both templating methods were compared in four outcomes: prediction of acetabular cup size, prediction of femoral stem size, prediction of femoral offset and prediction of femoral neck length. Digital templating was more accurate than analog templating in predicting acetabular cup size, femoral stem size and femoral offset. Analog templating was more accurate in predicting femoral neck length. However, only the comparison of femoral offset achieved statistical significance (p-value = 0.049). After stratifying the data by BMI, digital templating was more accurate than analog templating in predicting acetabular cup and femoral stem sizes for patients with high BMI. For patients with BMI = 25-30, accuracy of digital templating was 100.0% for cup and 80.0% for stem while accuracy of analog templating was 74.1% for cup and 74.1% for stem. For patients with BMI > 30, accuracy of digital templating was 84.6% for cup and 69.2% for stem while that of analog templating was 75.0% for cup and 66.7% for stem. Digital templating outperformed analog templating in all the outcomes except femoral neck length. In addition, digital templating was significantly more accurate in predicting femoral offset. This study showed that digital templating has the potential to reduce errors in pre-operative planning for THA.
Aims. Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct. Methods. We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on
Aims. Treatment of end-stage anteromedial osteoarthritis (AMOA) of the knee is commonly approached using one of two surgical strategies: medial unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). In this study we aim to investigate if there is any difference in outcome for patients undergoing UKA or TKA, when treated by high-volume surgeons, in high-volume centres, using two different clinical guidelines. The two strategies are ‘UKA whenever possible’ vs TKA for all patients with AMOA. Methods. A total of 501 consecutive AMOA patients (301 UKA) operated on between 2013 to 2016 in two high-volume centres were included. Centre One employed clinical guidelines for the treatment of AMOA allowing either UKA or TKA, but encouraged UKA wherever possible. Centre Two used clinical guidelines that treated all patients with a TKA, regardless of wear pattern. TKA patients were included if they had isolated AMOA on
Aims. We aimed to assess the cumulative risk of total hip arthroplasty (THA) from in situ fixation for slipped capital femoral epiphysis (SCFE) after a follow-up of almost 50 years. Methods. In this study, 138 patients with 172 affected hips treated with in situ fixation were evaluated retrospectively. A total of 97 patients (70%) were male and the mean age was 13.6 years (SD 2.1); 35 patients (25%) had a bilateral disease. The median follow-up time was 49 years (interquartile range 43 to 55). Basic demographic, stability, and surgical details were obtained from patient records.
Aims. Cementless unicompartmental knee arthroplasty (UKA) has advantages over cemented UKA, including improved fixation, but has a higher risk of tibial plateau fracture, particularly in Japanese patients. The aim of this multicentre study was to determine when cementless tibial components could safely be used in Japanese patients based on the size and shape of the tibia. Methods. The study involved 212 cementless Oxford UKAs which were undertaken in 174 patients in six hospitals. The medial eminence line (MEL), which is a line parallel to the tibial axis passing through the tip of medial intercondylar eminence, was drawn on
Aims. The aim of this study was to evaluate the ability of a machine-learning algorithm to diagnose prosthetic loosening from
An intra-articular steroid injection can be a useful diagnostic tool in patients presenting with debilitating hip pain and radiographically mild osteoarthritis. The clinical and patient reported outcomes associated with patients who have radiographically mild osteoarthritis and undergo total hip arthroplasty (THA) remain poorly studied. Patients undergoing primary, elective THA at a single academic medical center by a fellowship-trained adult reconstruction surgeon between 2017–2023 were identified. Only those patients who underwent an intra-articular corticosteroid injection into the operative hip within one year of surgery were included. Patients were divided into two cohorts based on the severity of their osteoarthritis as determined by
Introduction. Osteochondral lesions (OCLs) of the talus are a challenging and increasingly recognized problem in chronic ankle pain. Many novel techniques exist to attempt to treat this challenging entity. Difficulties associated with treating OCLs include lesion location, size, chronicity, and problems associated with potential graft harvest sites. Matrix associated stem cell transplantation (MAST) is one such treatment described for larger lesions >15mm2 or failed alternative therapies. This cohort study describes a medium-term review of the outcomes of talar lesions treated with MAST. Methods. A review of all patients treated with MAST by a single surgeon was conducted.
Aims. The aim of this study was to determine the clinical outcomes and factors contributing to failure of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, for advanced osteoarthritis secondary to hip dysplasia. Methods. We reviewed patients with Tönnis grade 2 osteoarthritis secondary to hip dysplasia who underwent TOA between November 1998 and December 2019. Patient demographic details, osteotomy-related complications, and the modified Harris Hip Score (mHHS) were obtained via medical notes review. Radiological indicators of hip dysplasia were assessed using preoperative and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors of failure. Results. This study included 127 patients (137 hips). Median follow-up period was ten years (IQR 6 to 15). The median mHHS improved from 59 (IQR 52 to 70) preoperatively to 90 (IQR 73 to 96) at the latest follow-up (p < 0.001). The survival rate was 90% (95% CI 82 to 95) at ten years, decreasing to 21% (95% CI 7 to 48) at 20 years. Fair joint congruity on
Acetabular retroversion is a recognised cause of hip impingement. Pelvic tilt influences acetabular orientation and is known to change in different functional positions. While previously reported in patients with developmental dysplasia of the hip, positional changes in pelvic tilt have not been studied in patients with acetabular retroversion. We retrospectively analysed supine and standing AP pelvic radiographs in 22 patients with
Introduction. Malposition of the acetabular component in total hip arthroplasty (THA) is linked to multiple adverse outcomes. Changes in the sagittal plane position of the pelvis, owing both to patient positioning in the operating room and to altered spinopelvic alignment following surgery, potentially contribute to variation in component position. The dynamics of sagittal plane pelvic position before, during, and after THA have not been defined. We measured the differences in pelvic ratio, a measure of sagittal plane pelvic position, between preoperative, intraoperative, and postoperative anteroposterior (AP) radiographs of patients undergoing THA in the lateral decubitus position. Methods. We retrospectively compared the radiographic pelvic ratio among 90 patients undergoing THA. AP radiographs were obtained in the standing position preoperatively and at 6 weeks after surgery; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post anesthesia care unit (PACU). Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Radlink software was used to determine the pelvic ratio on each radiograph. Changes in apparent cup position based on changes in pelvic ratio were calculated using data from the literature, and a change of at least 10 degrees in acetabular component position was defined as clinically meaningful. Analyses were performed using paired t-tests, with p<0.05 defined as significant. Results. 54% of patients had a change in pelvic ratio large enough to alter the apparent acetabular component anteversion by 10 degrees (49% increased and 6% decreased), and 12% had a change large enough to alter the apparent acetabular component inclination by 10 degrees (12% increased and 0% decreased) when the intraoperative AP radiograph was compared to the
Acetabular retroversion is a recognised cause of hip impingement. Pelvic tilt influences acetabular orientation and is known to change in different functional positions. While previously reported in patients with developmental dysplasia of the hip, positional changes in pelvic tilt have not been studied in patients with acetabular retroversion. We retrospectively analysed supine and standing AP pelvic radiographs in 22 patients with
Aims. The aims of this study were to determine the change in pelvic sagittal alignment before, during, and after total hip arthroplasty (THA) undertaken with the patient in the lateral decubitus position, and to determine the impact of these changes on acetabular component position. Patients and Methods. We retrospectively compared the radiological pelvic ratio among 91 patients undergoing THA. In total, 41 patients (46%) were female. The mean age was 61.6 years (. sd. 10.7) and the mean body mass index (BMI) was 20.0 kg/m. 2. (. sd. 5.5). Anteroposterior radiographs were obtained: in the standing position preoperatively and at six weeks postoperatively; in the lateral decubitus position after trial reduction intraoperatively; and in the supine position in the post-anaesthesia care unit. Pelvic ratio was defined as the ratio between the vertical distance from the inferior aspect of the sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior aspect of the SI joints. Changes in the apparent component position based on changes in pelvic ratio were determined, with a change of > 5° considered clinically significant. Analyses were performed using Wilcoxon’s signed-rank test, with p < 0.05 considered significant. Results. Intraoperatively, in the lateral decubitus position, the pelvic ratio increased (anterior tilt) in 69.4% of cases, did not change significantly in 20.4%, and decreased (posterior tilt) in 10.2% of cases. When six-week postoperative radiographs were compared with
Aims. The Wrightington classification system of fracture-dislocations of the elbow divides these injuries into six subtypes depending on the involvement of the coronoid and the radial head. The aim of this study was to assess the reliability and reproducibility of this classification system. Methods. This was a blinded study using radiographs and CT scans of 48 consecutive patients managed according to the Wrightington classification system between 2010 and 2018. Four trauma and orthopaedic consultants, two post CCT fellows, and one speciality registrar based in the UK classified the injuries. The seven observers reviewed
Introduction. Robotics have been applied to total knee arthroplasty (TKA) to improve surgical precision in component placement and joint function restoration. The purpose of this study was to evaluate prosthetic component alignment in robotic arm-assisted (RA)-TKA performed with functional alignment and intraoperative fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. It was hypothesized that functionally aligned RA-TKA the femoral and tibial cuts would be performed in line with the preoperative joint line orientation. Methods. Between September 2018 and January 2020, 81 RA cruciate retaining (CR) and posterior stabilized (PS) TKAs were performed at a single center.
Introduction. Prosthetic replacement remains the treatment of choice for displaced femoral neck fractures in the elderly population, with recent literature demonstrating significant functional benefits of total hip arthroplasty (THA) over hemiarthroplasty. Yet the fracture population also has historically high rates of early postoperative instability when treated with THA. The direct anterior approach (DAA) may offer the potential to decrease the risk of postoperative instability in this high-risk population by maintaining posterior anatomic structures. The addition of intraoperative fluoroscopy can improve precision in component placement and overcome limitations on preoperative planning due to poor
Aims. Assessment of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA) is a well-established clinical technique, but it is not available in the acute trauma setting. Thus, it cannot provide a preoperative estimation of BMD to help guide the technique of fracture fixation. Alternative methods that have been suggested for assessing BMD include: 1) cortical measures, such as cortical ratios and combined cortical scores; and 2) aluminium grading systems from
Introduction. Periacetabular osteotomy (PAO) is the preferred treatment for symptomatic acetabular dysplasia in adolescents and young adults. There remains a lack of consensus regarding whether intra-articular work such as labral repair or improvement of femoral offset should be performed at the time of PAO or addressed subsequent to PAO if symptoms warrant. The purpose of this review was to determine the rate of subsequent hip arthroscopy (HA) in a contemporary PAO cohort with no intra-articular work performed at the time of PAO. Methods. From June 2012 to September 2019, 272 Rectus Sparing PAOs were performed and followed for a minimum of one year (mean 4.6 years). The average age was 24 (range 14–44) and 87% were female. The average BMI was 25 and average length of hospital stay was 2.9 days. Patients were evaluated at last follow-up with PROMIS PF-CAT, pain and mental health scores. Clinical records were reviewed for complications or subsequent surgery. Pre and post-operative radiographs were reviewed for change in the following acetabular parameters: LCEA, ACEA, AI, and the alpha-angle was obtained from
Internal fixation is currently the standard of care for Garden I and II femoral neck fractures in the elderly. However, there may be a degree of posterior tilt on the