Osteosynthesis aims to maintain fracture reduction until bone healing occurs, which is not achieved in case of mechanical fixation failure. One form of failure is plastic plate bending due to overloading, occurring in up to 17% of midshaft fracture cases and often necessitating reoperation. This study aimed to replicate in-vivo conditions in a cadaveric experiment and to validate a finite element (FE) simulation to
Anterior approach total hip arthroplasty (AA-THA) has a steep learning curve, with higher complication rates in initial cases. Proper surgical case selection during the learning curve can reduce early risk. This study aims to identify patient and radiographic factors associated with AA-THA difficulty using Machine Learning (ML). Consecutive primary AA-THA patients from two centres, operated by two expert surgeons, were enrolled (excluding patients with prior hip surgery and first 100 cases per surgeon). K- means prototype clustering – an unsupervised ML algorithm – was used with two variables - operative duration and surgical complications within 6 weeks - to cluster operations into difficult or standard groups. Radiographic measurements (neck shaft angle, offset, LCEA, inter-teardrop distance, Tonnis grade) were measured by two independent observers. These factors, alongside patient factors (BMI, age, sex, laterality) were employed in a multivariate logistic regression analysis and used for k-means clustering. Significant continuous variables were investigated for
Multiple biochemical biomarkers have been previously investigated for the diagnosis, prognosis and response to treatment of articular cartilage damage, including osteoarthritis (OA). Synovial fluid (SF) biomarker measurement is a potential method to
Abstract. Objectives. Identifying risk factors for inferior outcomes after anterior cruciate ligament reconstruction (ACLR) is important for prognosis and patient information. This study aimed to ascertain if BMI, pre-operative scores, demographic data and concomitant injuries in patients undergoing ACLR affected patient-reported functional outcomes. Methods. A prospective review collected data from a single surgeon series of 278 patients who underwent arthroscopic ACLR. BMI, age, gender, graft choice, pre-op Lysholm score, meniscal and chondral injuries were recorded. The Lysholm score, hop test and KT1000 were used to measure post-op functional outcome at one year. Multiple regression analysis was used to determine factors that
Proximal humerus fractures are the third most common fragility fractures with treatment remaining challenging. Mechanical fixation failure rates of locked plating range up to 35%, with 80% of them being related to the screws perforating the glenohumeral joint. Secondary screw perforation is a complex and not yet fully understood process. Biomechanical testing and finite element (FE) analysis are expected to help understand the importance of various risk factors. Validated FE simulations could be used to
Background. Although there are
Objectives. Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in
Pre-operative 3D glenoid planning improves component placement in terms of version, inclination, offset and orientation. Version and inclination measurements require the position of the inferior angle. As a consequence, current planning tools require a 3D model of the full scapula to accurately determine the glenoid parameters. Statistical shape models (SSMs) can be used to reconstruct the missing anatomy of bones. Therefore, the objective of this study is to develop and validate an SSM for the reconstruction of the inferior scapula, hereby reducing the irradiation exposure for patients. The training dataset for the statistical shape consisted of 110 CT images from patients without observable scapulae pathologies as judged by an experienced shoulder surgeon. 3D scapulae models were constructed from the segmented images. An open-source non-rigid B-spline-based registration algorithm was used to obtain point-to-point correspondences between the models. A statistical shape model was then constructed from the dataset using principal component analysis. Leave-one-out cross-validation was performed to evaluate the accuracy of the
Worldwide, osteoporosis, causes more than 8.9 million fractures annually, resulting in an osteoporotic fracture every 3 seconds, where 1 in every 3 women and 1 in every 5 men aged over 50 will experience osteoporotic fractures at least once in their lifetime. Vertebral fractures, estimated at 1.4 million/year are among the most common fractures, posing enormous health and socioeconomic challenges to the individual and society at large. Considering that the great majority of individuals at high risk (up to 80%), who have already had at least one osteoporotic fracture, are neither identified nor treated, prediction of the risk factors for vertebral fractures can be of great value for prevention/early diagnosis. Recent studies show that finite element analysis of computed tomography (CT) scans provides noninvasive means to assess fracture risk and has the potential to be clinically implemented upon proper validation. The objective of this study was to develop a voxel-based finite element model using quantitative computed tomography (QCT) images in conjunction with in-vitro experiments to evaluate the strength of the vertebral bodies and
Summary Statement. The constraint behavior of total knee arthroplasty (TKA) prosthesis usually has to be physically tested. This study presents a computer simulation model using finite element analysis (FEA) and demonstrates its effectiveness in
A principle of Total Knee Arthroplasty (TKA) is to achieve a neutral standing coronal alignment of the limb (Hip Knee Ankle (HKA) angle) to reduce risks of implant loosening, reduce polyethylene wear, and optimise patella tracking. Several long-term studies have questioned this because the relationship between alignment and implant survivorship is weaker than previously reported. We hypothesize standing HKA poorly
Summary Statement. A coupled finite element - analytical model is presented to
The ability to
When performing total hip replacements in patients with hip dysplasia, acetabular augmentation may be required to prevent early component failure. Preoperative radiographic templating may help estimate acetabularcomponent coverage but has not previously been shown to
The ankle cartilage has an important function in walking movements, mainly in sports; for active young people, between 20 and 30 years old, the incidence of osteochondral lesions is more frequent. They are also more frequent in men, affecting around 21,000 patients per year in USA with 6.5% of ankle injuries generating osteochondral lesions. The lesion is a result of ankle sprain and is most frequently found in the medial location, in 53% of cases. The main objective of this work was to develop an experimental and finite element models to study the effect of the ankle osteochondral lesion on the cartilage behavior. The right ankle joint was reconstructed from an axial CT scan presenting an osteochondral lesion in the medial position with 8mm diameter in size. An experimental model was developed, to analyze the strains and influence of lesion size and location similar to the patient. The experimental model includes two cartilages constructed by Polyjet™ 3D printing from rubber material (young modulus similar to cartilage) and bone structures from a rigid polymer. The cartilage was instrumented with two rosettes in the medial and lateral regions, near the osteochondral region. The fluid considered was water at room temperature and the experimental test was run at 1mm/s. The Finite element model (FE) includes all the components considered in the experimental apparatus and was assigned the material properties of bone as isotropic and linear elastic materials; and the cartilage the same properties of rubber material. The fluid was simulated as hyper-elastic one with a Mooney-Rivlin behavior, with constants c1=0.07506 and c2=0.00834MPa. The load applied was 680N in three positions, 15º extension, neutral and 10º flexion.Introduction
Materials and Methods
Clavicle fractures are common, yet debate exists regarding which patients would benefit from conservative versus operative management. Traditionally shortening greater than 2cm has been accepted as an indicator for surgery. However, clavicle length varies between individuals. In a cadaveric study clavicle shortening greater than 15% was suggested to affect outcomes. There is no clinical correlation of this in the literature. In this study we investigate outcomes following middle third clavicle fractures and the effect of percentage shortening on union rates. We identified a consecutive series of adults with primary midshaft clavicle fractures presenting to our institution from April 2015-March 2017. Clinical records and radiographs were reviewed to elicit outcomes. Time to union was measured against factors including; percentage shortening, displacement, comminution and smoking. Statistical significance was calculated.Abstract
Objectives
Methods
INTRODUCTION. Loss of joint function is only exploited in osteoarthritis (OA) once severe impairment is apparent. Animal models allow for lesion induction and serial OA progression measures. We recently described an adjustable non-surgical loading model for generating focal cartilage lesions in only the lateral femur joint compartment, in which regimes can be adjusted so that these either do or do not progress spontaneously. Herein, we use ventral plane videographic treadmill gait analysis to determine whether gait changes can be used to discriminate between stable and spontaneously progressing lesions, induced by these two loading regimes. METHODS. Animals encountered normal conditions, except during loading (9N, 40 cycles, 0.1 Hz, 10 sec/ cycle) which was applied to right knees in two groups (n=8) of 8-week-old male CBA mice: i) loaded once; ii) loaded 3 times/week for 2 weeks. Gait (including: brake, propel, stance, stride, stride length, stride frequency, steps and paw area) was assessed 3 times/week for 2 weeks in each mouse using a DigigaitTM treadmill. Thereafter, mice received 5mg/kg carprofen for analgesia and gait analysis repeated on 3 further alternate days. RESULTS. The two loading regimes produced virtually identical gait modifications with delayed onset (apparent on day 3) which remained unchanged for 2 weeks; mice loaded once only showed modified contralateral limb use, but those loaded multiply exhibited additional ipsilateral front limb modifications; no changes in gait were observed in loaded limbs. Intriguingly, the two regimes produced distinct responses to analgesia. Load-induced gait changes were completely rescued by carprofen in mice loaded only once, whilst those in mice loaded repetitively persisted. CONCLUSION. Our findings reveal specific and reproducible, compensatory changes in contralateral, non-loaded limb gait induced by any joint loading which produces focal articular lesions, and modified ipsilateral front limb use only when progressing lesions are induced by repetitive loading. We find that pain relief completely alleviates all gait modifications associated with stable lesions induced by single loading, but not those induced by repetitive loading. Differing responses in mice with stable and progressive articular cartilage load-induced lesions suggests that gait behaviour in a mechanical loading model of OA may
Substance P is readily detected in the synovial fluid of the knee in which it acts as a powerful inflammatory agent in response to injury and disease. It may be an objective
The operative treatment of fractures of the proximal humerus can be complicated by poor bone quality. Our aim was to evaluate a new method which allows prediction of the bone quality of the proximal humerus from radiographs. Anteroposterior radiographs were taken of 19 human cadaver humeri. The cortical thickness was measured at two levels of the proximal humeral diaphysis. The bone mineral density (BMD) was determined for the humeral head (HH), the surgical neck (SN), the greater tuberosity (GT) and lesser tuberosity (LT) using dual-energy x-ray absorptiometry. The mean cortical thickness was 4.4 ± 1.0 mm. Specimens aged 70 years or less had a significantly higher cortical thickness than those aged over 70 years. A significant positive correlation was found between cortical thickness and the BMD for each region of interest. The cortical thickness of the proximal diaphysis is a reliable
Understanding vertebral fracture is important in order to reduce fracture risk. Previous studies have used FE to investigate mechanical behaviour, typically using a linear material response. This study aimed to establish a novel model that could represent the plastic behaviour leading to fracture. Porcine vertebrae were mCT scanned and they were loaded to failure in a material test machine (Instron 5965). The specimens were then rescanned. From the first scan, specimen specific FE models were created (ScanIP, Simpleware, UK). Mesh convergence was studied and tetrahedral elements with an approximate element size of 0.7 were used for computational simulations. The relationship between greyscale values (GS) and Young's modulus (E) was optimised to match the experimental load displacement data using Ansys. Further, a plastic material response was modelled.Background
Method