Aims. Steroid injections are used for subacromial pain syndrome and can be administered via the anterolateral or
As Total Hip Replacement (THR) rates increase healthcare providers have sought to reduce costs, while at the same time improving patient safety and satisfaction. Up to 50% of patients may be appropriate for Day Case THR, and in appropriately selected patients’ studies show no increase in complication rate while affording a significant cost saving and maintaining a high rate of patient satisfaction. Despite the potential benefits, levels of adoption of Day Case THR vary. A common cause for this is the perception that doing so would require the adoption of new surgical techniques, implants, or theatre equipment. We report on a Day-Case THR pathway in centres with an established and well-functioning Enhanced Recovery pathway, utilising the
Introduction. While additional resources associated with direct anterior (DA) approach total hip arthroplasty (THA) such as fluoroscopy, staff, and special tables are well recognized, time consumption is not well studied. The purpose of this study was to analyze anesthesia and surgical time in DA and
Aims. The aims of this study were to assess the exposure and preservation of the abductor mechanism during primary total hip arthroplasty (THA) using the
The Posterior and Lateral approaches are most commonly used for Total Hip Arthroplasty (THA) in the United Kingdom (UK). Fewer than 5% of UK surgeons routinely use the Direct Anterior Approach (DAA). DAA THA is increasing, particularly among surgeons who have learned the technique during overseas fellowships. Whether DAA offers long-term clinical benefit is unclear. We undertook a retrospective analysis of prospectively collected 10-year, multi-surgeon, multi-centre implant surveillance study data for matched cohorts of patients whose operations were undertaken by either the DAA or
Introduction: Despite the advances in total hip arthroplasty (THA), a dislocation after THA remains a disturbing complication. Dislocation after revision hip arthroplasty has been an underemphasized cause of failure in revision hip arthroplasty despite its higher dislocation rate than after primary THA. The effectiveness of posterior soft tissue repair in the
Periprosthetic femur fracture (PFF) is a major complication following total hip arthroplasty (THA) that carries significant morbidity, mortality, and economic burden. Currently, uncemented stems are highly preferred in primary THA, but have been associated with higher risk of PFF compared to cemented stems. The use of collared stems in uncemented primary THA has shown promise in reducing PFF rates postoperatively. This retrospective study included 2,294 uncemented primary THAs using the
Range of Motion (ROM) assessments are routinely used during joint replacement to evaluate joint stability before, during and after surgery to ensure the effective restoration of patient biomechanics. This study aimed to quantify axial torque in the femur during ROM assessment in total hip arthroplasty to define performance criteria against which hip instruments can be verified. Longer term, this information may provide the ability to quantitatively assess joint stability, extending to quantitation of bone preparation and quality. Joint loads measured with strain-gaged instruments in five cadaveric femurs prepared using
Introduction. The hip hemiarthroplasty in
The direct superior approach (DSA) is a modification of the
Introduction: Various surgical approaches have been described for the hip joint but the optimal surgical approach for total hip replacement remains controversial. The lateral approach &
the
The mini-incision
The purpose of this study was to investigate the influence of surgical approach on femoral stem version in THA. This was a retrospective database review of 830 THAs in 830 patients that had both preoperative and postoperative CT scans. All patients underwent staged bilateral THAs and received CT-based 3D planning on both sides. Stem version was measured in the second CT-scan and compared to the native neck axis measured in the first CT-scan, using the posterior condyles as the reference for both. Cases were performed by 104 surgeons using either a direct anterior (DAA, n=303) or posterior (PA, n=527) approach and one of four stem designs: quadrangular taper, calcar-guided short stem, flat taper and fit-and-fill. Sub-analyses investigated changes in version for low (≤5°), neutral (5–25°) and high (≥25°) native version subgroups and for the different implant types. Native version was not different between approaches (DAA = 12.6°, PA = 13.6°, p = 0.16). Overall, DAA stems were more anteverted relative to the native neck axis vs PA stems (5.9° vs 1.4°, p<0.001). This trend persisted in hips with high native version (3.2° vs -5.3°, p<0.01) and neutral native version (5.3° vs 1.3°, p<0.001), but did not reach significance in the low native version subgroup (8.9° vs 5.9°, p=0.13). Quadrangular taper, calcar-guided, and flat taper stem types had significantly more anteversion than native for DAA, while no differences were found for PA. Stems implanted with a direct anterior approach had more anteversion than those implanted with a
A combined anterior and posterior surgical approach
is generally recommended in the treatment of severe congenital kyphosis,
despite the fact that the anterior vascular supply of the spine
and viscera are at risk during exposure. The aim of this study was
to determine whether the surgical treatment of severe congenital thoracolumbar
kyphosis through a single
We investigated the relationship of the inferior gluteal nerve to gluteus maximus by dissecting the muscle in 12 fresh-frozen and formalin-treated cadavers. The anatomy was recorded using still digital photography. The course of the inferior gluteal nerve was carefully traced and was noted to enter the deep surface of gluteus maximus approximately 5 cm from the tip of the greater trochanter of the femur. The susceptibility of the nerve to injury during a
Aims. Patients with femoral neck fractures (FNFs) treated with total hip arthroplasty (THA) have an almost ten-fold increased risk of dislocation compared to patients undergoing elective THA. The surgical approach influences the risk of dislocation. To date, the influence of differing head sizes and dual-mobility components (DMCs) on the risk of dislocation has not been well studied. Methods. In an observational cohort study on 8,031 FNF patients with THA between January 2005 and December 2014, Swedish Arthroplasty Register data were linked with the National Patient Register, recording the total dislocation rates at one year and revision rates at three years after surgery. The cumulative incidence of events was estimated using the Kaplan-Meier method. Cox multivariable regression models were fitted to calculate adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) for the risk of dislocation, revision, or mortality, stratified by surgical approach. Results. The cumulative dislocation rate at one year was 8.3% (95% CI 7.3 to 9.3) for patients operated on using the
Background:. Modified
Introduction:. The routine use of posterior hip dislocation precautions is typically utilized postoperatively following total hip arthroplasty via a posterior surgical approach. This has included use of an abduction pillow and limiting adduction, internal rotation and flexion more than 90 degrees for a minimum of 6 weeks postoperatively. This may slow the course of rehabilitation, increase the length of hospital stay and the total cost of the procedure, and add additional anxiety to the patient. We conducted this study to see if posterior hip precautions are necessary after total hip arthroplasty via a
Despite a lack of long-term follow-up, there
is an increasing trend towards using femoral heads of large diameter
in total hip replacement (THR), partly because of the perceived
advantage of lower rates of dislocation. However, increasing the
size of the femoral head is not the only way to reduce the rate
of dislocation; optimal alignment of the components and repair of
the posterior capsule could achieve a similar effect. . In this prospective study of 512 cemented unilateral THRs (Male:Female
230:282) performed between 2004 and 2011, we aimed to determine
the rate of dislocation in patients who received a 22 mm head on
a 9/10 Morse taper through a
Introduction. Computer navigation systems are quite sophisticated intra-operative support systems for the precise placement of acetabular or femoral components in THA. However, few studies have addressed the clinical benefits derived from using a navigation system to achieve precise placement of the implants. The purpose of this study is to investigate the early dislocation rate of navigation-assisted primary THA through a