Advertisement for orthosearch.org.uk
Results 1 - 20 of 413
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 727 - 735
1 Jun 2020
Burger JA Dooley MS Kleeblad LJ Zuiderbaan HA Pearle AD

Aims. It remains controversial whether patellofemoral joint pathology is a contraindication to lateral unicompartmental knee arthroplasty (UKA). This study aimed to evaluate the effect of preoperative radiological degenerative changes and alignment on patient-reported outcome scores (PROMs) after lateral UKA. Secondarily, the influence of lateral UKA on the alignment of the patellofemoral joint was studied. Methods. A consecutive series of patients who underwent robotic arm-assisted fixed-bearing lateral UKA with at least two-year follow-up were retrospectively reviewed. Radiological evaluation was conducted to obtain a Kellgren Lawrence (KL) grade, an Altman score, and alignment measurements for each knee. Postoperative PROMs were assessed using the Kujala (Anterior Knee Pain Scale) score, Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), and satisfaction levels. Results. A total of 140 knees (130 patients) were identified for analysis. At mean 4.1 years (2.0 to 8.5) follow-up, good to excellent Kujala scores were reported. The presence of mild to moderate preoperative patellofemoral joint osteoarthritis had no impact on these scores (KL grade 0 vs 1 to 3, p = 0.203; grade 0 to 1 vs 2 to 3, p = 0.674). Comparable scores were reported by patients with osteoarthritis (Altman score of ≥ 2) evident on either the medial or lateral patellofemoral joint facet (medial, p = 0.600 and lateral, p = 0.950). Patients with abnormal patellar congruence and tilt angles (≥ 17° and ≥ 14°, respectively) reported good to excellent Kujala scores. Furthermore, lateral UKA resulted in improvements to patellofemoral alignment. Conclusion. This is the first study demonstrating that mild to moderate preoperative radiological degenerative changes and malalignment of the patellofemoral joint are not associated with poor patient-reported outcomes at mid-term follow-up after lateral fixed-bearing UKA. Our data suggest that this may be explained by realignment of the patella and thereby redistribution of loads across the patellofemoral joint. Cite this article: Bone Joint J 2020;102-B(6):727–735


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 52 - 52
1 Jul 2022
Kurien T East J Mandalia V
Full Access

Abstract. Introduction. To investigate the impact medial opening wedge high tibial osteotomy (MOWHTO) has on the progression of patellofemoral OA, patella height and contact pressure within the patellofemoral joint (PF). Methods. A systematic review was conducted in January 2022 according to PRISMA guidelines. Each study was graded as per the MINORS criteria for non-randomised trials. The ICRS cartilage grade of the PF joint at the initial MOWHTO surgery and at second look surgery was compared and relative risk of progression of PF OA was calculated. Evaluation of patella height was assessed by Caton-Deschamps index, Blackburne-Peel index or Insall-Salvati ratio pre and post MOWHTO. Cadaveric studies assessing contact pressures in the PF after MOWHTO were included. Results. Forty-two studies comparing 2,419 patients were included. The mean age was 53.1 years (16–84), 61.3% female. The risk of progression of PF OA was highest in the uniplanar and biplanar MOWHTO with proximal tubercle osteotomy groups (RR= 1.28-1.51, I2= 0%), compared to biplanar MOHWTO with distal tubercle osteotomy (RR= 0.96-1.04, I2 = 0%). Patella height was not affected after biplanar MOWHTO and distal tubercle osteotomy. (P<0.001). Cadaveric studies demonstrate that PF contact pressures increase with more severe corrections (10°) but suggest biplanar MWOHTO and distal tubercle osteotomy induces lower contact pressures within the PF joint than other OWHTO techniques. Conclusion. This novel systematic review demonstrates that biplanar MOWHTO and distal tubercle osteotomy causes lower contact pressures in the PF joint, less severe progression of PF OA and has minimal impact on patella height


Bone & Joint Open
Vol. 4, Issue 12 | Pages 948 - 956
15 Dec 2023
Vella-Baldacchino M Webb J Selvarajah B Chatha S Davies A Cobb JP Liddle AD

Aims. With up to 40% of patients having patellofemoral joint osteoarthritis (PFJ OA), the two arthroplasty options are to replace solely the patellofemoral joint via patellofemoral arthroplasty (PFA), or the entire knee via total knee arthroplasty (TKA). The aim of this study was to assess postoperative success of second-generation PFAs compared to TKAs for patients treated for PFJ OA using patient-reported outcome measures (PROMs) and domains deemed important by patients following a patient and public involvement meeting. Methods. MEDLINE, EMBASE via OVID, CINAHL, and EBSCO were searched from inception to January 2022. Any study addressing surgical treatment of primary patellofemoral joint OA using second generation PFA and TKA in patients aged above 18 years with follow-up data of 30 days were included. Studies relating to OA secondary to trauma were excluded. ROB-2 and ROBINS-I bias tools were used. Results. A total of nine studies were included, made up of four randomized controlled trials (domain 1) and five cohort studies (domain 2). PROMs and knee function specific scores developed for reporting TKA were unable to detect any difference between PFA and TKA. There was no significant difference in complications between PFA and TKA. PFAs were found to have a better postoperative range of motion. Conclusion. TKA and PFA are both viable options for patients with primary PFJ OA. Over time, we have seen an emphasis on patient satisfaction and better quality of life. Recommending sacrificing healthy medial and lateral compartments to treat patellofemoral joint arthritis should be given further thought. Cite this article: Bone Jt Open 2023;4(12):948–956


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1585 - 1591
1 Dec 2018
Kaneko T Kono N Mochizuki Y Hada M Sunakawa T Ikegami H Musha Y

Aims. Patellofemoral problems are a common complication of total knee arthroplasty. A high compressive force across the patellofemoral joint may affect patient-reported outcome. However, the relationship between patient-reported outcome and the intraoperative patellofemoral contact force has not been investigated. The purpose of this study was to determine whether or not a high intraoperative patellofemoral compressive force affects patient-reported outcome. Patients and Methods. This prospective study included 42 patients (42 knees) with varus-type osteoarthritis who underwent a bi-cruciate stabilized total knee arthroplasty and in whom the planned alignment was confirmed on 3D CT. Of the 42 patients, 36 were women and six were men. Their mean age was 72.3 years (61 to 87) and their mean body mass index (BMI) was 24.4 kg/m2 (18.2 to 34.3). After implantation of the femoral and tibial components, the compressive force across the patellofemoral joint was measured at 10°, 30°, 60°, 90°, 120°, and 140° of flexion using a load cell (Kyowa Electronic Instruments Co., Ltd., Tokyo, Japan) manufactured in the same shape as the patellar implant. Multiple regression analyses were conducted to investigate the relationship between intraoperative patellofemoral compressive force and patient-reported outcome two years after implantation. Results. No patient had anterior knee pain after total knee arthroplasty. The compressive force across the patellofemoral joint at 140°of flexion was negatively correlated with patient satisfaction (R2 = 0.458; β = –0.706; p = 0. 041) and Forgotten Joint Score-12 (FJS-12; R2= .378; β = –0.636; p = 0. 036). The compressive force across the patellofemoral joint at 60° of flexion was negatively correlated with the patella score (R2 = 0.417; β = –0.688; p = 0. 046). Conclusion. Patient satisfaction, FJS-12, and patella score were affected by the patellofemoral compressive force at 60° and 140° of flexion. Reduction of the patellofemoral compressive forces at 60° and 140° of flexion angle during total knee arthroplasty may improve patient-reported outcome, but has no effect on anterior knee pain


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1579 - 1582
1 Dec 2009
Starks I Roberts S White SH

We present a prospective review of the two-year functional outcome of 37 Avon patellofemoral joint replacements carried out in 29 patients with a mean age of 66 years (30 to 82) between October 2002 and March 2007. No patients were lost to follow-up. This is the first independent assessment of this prosthesis using both subjective and objective analysis of outcome. At two years the median Oxford knee score was 39 (interquartile range 32 to 44), the median American Knee Society objective score was 95 (interquartile range 90 to 100), the median American Knee Society functional score was 85 (interquartile range 60 to 100), and the median Melbourne Knee score was 28 (interquartile range 21 to 30). Two patients underwent further surgery. Only one patient reported an unsatisfactory outcome. We conclude that the promising early results observed by the designing centre are reproducible and provide further support for the role of patellofemoral joint replacement


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 69 - 69
7 Aug 2023
Kumar A Stevens S Jonas S White S Agarwal S
Full Access

Abstract. Introduction. Isolated patellofemoral joint(PFJ) osteoarthritis affects approximately 10% of patients aged over 40 years and treatment remains controversial. Our aim was to evaluate long term functional and radiological outcomes following PFJ arthorplasty with the Femoro Patella Vialli (FPV) prosthesis as this evidence is lacking in literature. Methodology. A retrospective review of prospectively collected PROMS in patients undergoing Patellofemoral arthroplasty. Single centre trial. Between 2004 and 2008, 101 FPV patellofemoral arthroplasties were performed in 80 patients with isolated patellofemoral joint osteoarthritis. Data was collected as a part of routine follow-up for up to 6 years and additional long term data was collected at 16 years. Results. At 6 year follow up the mean OKS was 29 and by 16 year follow up it was 26 which was not a statistically significant drop. 22 patients (29 knees) had died, 32 (32%) had been revised, 25 to total knee replacement using primary arthroplasty components. Mean OKS in the revised group was 27 which was not a statistically significant difference when compared to the unrevised group. Mean time to revision was 4 years. The cumulative survival analysis of the FPV implant was 76% at 5 years, 64% at 10 years. Conclusion. Our findings suggest the FPV patellofemoral prosthesis provides good pain relief and clinical outcomes however, the survivorship for this particular implant maybe lower as compared to the available literature. Patient reported outcomes are maintained over the implant life and are no worse once revised implying a staged approach to arthroplasty is reasonable


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1602 - 1607
1 Dec 2007
Beard DJ Pandit H Ostlere S Jenkins C Dodd CAF Murray DW

Anterior knee pain and/or radiological evidence of degeneration of the patellofemoral joint are considered to be contraindications to unicompartmental knee replacement. The aim of this study was to determine whether this is the case. Between January 2000 and September 2003, in 100 knees (91 patients) in which Oxford unicompartmental knee replacements were undertaken for anteromedial osteoarthritis, pre-operative anterior knee pain and the radiological status of the patellofemoral joint were defined using the Altman and Ahlback systems. Outcome was evaluated at two years with the Oxford knee score and the American Knee Society score. Pre-operatively 54 knees (54%) had anterior knee pain. The clinical outcome was independent of the presence or absence of pre-operative anterior knee pain. Degenerative changes of the patellofemoral joint were seen in 54 patients (54%) on the skyline radiographs, including ten knees (10%) with joint space obliteration. Patients with medial patellofemoral degeneration had a similar outcome to those without. For some outcome measures patients with lateral patellofemoral degeneration had a worse score than those without, but these patients still had a good outcome, with a mean Oxford knee score of 37.6 (SD 9.5). These results show that neither anterior knee pain nor radiologically-demonstrated medial patellofemoral joint degeneration should be considered a contraindication to Oxford unicompartmental knee replacement. With lateral patellofemoral degeneration the situation is less well defined and caution should be observed


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 87 - 87
1 Nov 2016
Matz J Morden D Teeter M McCalden R MacDonald S Vasarhelyi E McAuley J Naudie D Howard J Lanting B
Full Access

Complications involving the patellofemoral joint are a source of anterior knee pain, instability, and dysfunction following total knee arthroplasty. “Overstuffing” the patello-femoral joint refers to an increase in the thickness of the patellofemoral joint after a total knee replacement compared to the preoperative thickness. While biomechanical studies have indicated that overstuffing the patellofemoral joint may lead to adverse clinical outcomes, limited clinical evidence exists to support this notion. The purpose of this study is to evaluate the effect of changing the thickness of the patellafemoral joint on functional outcomes following total knee arthroplasty. Our institutional arthroplasty database was used to identify 1347 patients who underwent a primary total knee arthroplasty between 2006 and 2012 with the same component design. Standard preoperative and postoperative anteroposterior, lateral, and skyline radiographs were collected and measured for patello-femoral overstuffing. These measurements included anterior patellar displacement, anterior femoral offset, and anteroposterior femoral size. These measurements were correlated with patient outcome data using WOMAC, KSS scores, and postoperative range of motion. Multiple linear regression analysis was used to assess the association between stuffing and functional outcomes. A total of 1031 patients who underwent total knee arthroplasty were included. Increased anterior patellar displacement, a measure of patellofemoral joint thickness, was associated with decreased WOMAC scores (p=0.02). Anterior femoral offset (p=0.210) and anteroposterior femoral size (p=0.091) were not significantly associated with patient functional outcomes. Postoperative range of motion (ROM) was not associated with patellofemoral stuffing (p=0.190). The current study demonstrated that functional outcomes are adversely affected by patellofemoral overstuffing. Based on these results, caution is encouraged against increasing the thickness of the patellofemoral joint, particularly on the patellar side of the joint


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 552 - 558
1 May 2019
Clark D Stevens JM Tortonese D Whitehouse MR Simpson D Eldridge J

Aims. The aim of this study was to determine and compare the congruency of the articular surface contact area of the patellofemoral joint (PFJ) during both active and passive movement of the knee with the use of an MRI mapping technique in both the stable and unstable PFJ. Patients and Methods. A prospective case-control MRI imaging study of patients with a history of PFJ instability and a control group of volunteers without knee symptoms was performed. The PFJs were imaged with the use of an MRI scan during both passive and active movement from 0° through to 40° of flexion. The congruency through measurement of the contact surface area was mapped in 5-mm intervals on axial slices. In all, 40 patients were studied. The case group included 31 patients with symptomatic patellofemoral instability and the control group of nine asymptomatic volunteers. The ages were well matched between the case and control groups. The mean age was 25 years (16 to 42; . sd. 6.9) in the case group and 26 years (19 to 32; . sd. 5.1) in the control group. There were 19 female and 12 male patients in the case group. Results. The unstable PFJs were demonstrably less congruent than the stable PFJs throughout the range of knee movement. The greatest mean differences in congruency between unstable and stable PFJ’s were observed between 11° and 20° flexion (1.73 cm. 2. vs 4.00 cm. 2. ; p < 0.005). . Conclusion. The unstable PFJ is less congruent than the stable PFJ throughout the range of knee movement studied. This approach to mapping PFJ congruency produces a measurable outcome and will allow the assessment of pre- and postoperative results following surgical intervention. This may facilitate the design of new procedures for patients with PFJ instability. If a single axial series is to be obtained on MRI scan, the authors recommend 11° to 20° of tibiofemoral flexion, as this was shown to have the greatest difference in contact surface area between the case and control groups. Cite this article: Bone Joint J 2019;101-B:552–558


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 7 - 7
1 Apr 2018
Cowie R Briscoe A Fisher J Jennings L
Full Access

Introduction. Experimental wear simulation of an all-polymer knee implant has shown an equivalent rate of wear of UHMWPE tibial components against PEEK-OPTIMA™ and cobalt chrome femoral components of a similar initial geometry and surface topography. However, when the patella is resurfaced with an UHMWPE patella button, it is important to also ascertain the wear of the patella. Wear debris from the patella contributes to the total volume of wear debris produced by the implant which should be minimised to reduce the potential for osteolysis and subsequent implant loosening. The aim of this study was to investigate the wear of the patellofemoral joint in an all-polymer knee implant. The wear of UHMWPE patellae articulating against PEEK-OPTIMA™ femoral components was compared to UHMWPE articulating against cobalt chrome femoral components. Materials and Methods. Six mid-size (size C) PEEK-OPTIMA™ femoral components (Invibio Knee Ltd., UK) and six cobalt chrome femoral components of similar initial surface topography and geometry were coupled with 28mm all-polyethylene GUR1020 patellae (conventional, EO sterile) (Maxx Orthopaedics, USA). The implants were set up in a ProSim 6 station electromechanical knee simulator (Simulation Solutions, UK) which was modified for testing the patellofemoral joint. 3 million cycles (MC) of wear simulation was carried out under kinematics aiming to replicate a gait cycle adapted for an electromechanical simulator from previous work by Maiti et al. The simulator used has six degrees of freedom of which four were controlled; axial force up to 1200N, flexion/extension 22°, superior-inferior (SI) displacement (22mm) and Abduction-adduction (AA) (4°). The SI and AA were displacement controlled and driven through the patella. The medial-lateral displacement and tilt (internal/external rotation) of the patella were passive so the patella button was free to track the trochlear groove. The lubricant used was 25% bovine serum supplemented with 0.03% sodium azide to retard bacterial growth. The wear of patellae was determined gravimetrically with unloaded soak controls used to compensate for the uptake of moisture by the UHMWPE. The mean wear rate ± 95% confidence limits were calculated and statistical analysis was carried out using ANOVA with significance taken at p<0.05. Results. The mean wear rates of the UHMWPE patellae were 0.26±0.21 mm. 3. /MC and 0.35±0.17 mm. 3. /MC against PEEK-OPTIMA™ and cobalt chrome femoral components respectively. There was no significant difference in wear rate against the different femoral component materials (P=0.38). Against both femoral component materials, a ‘bow tie’ shaped wear scar was evident on the patellae typical of that seen in retrieval studies and reported in previous experimental wear simulation of the patellofemoral joint. Conclusion. The wear rate of the UHMWPE patellae was low against both PEEK-OPTIMA™ and cobalt chrome femoral components and comparable to previous work by Vanbiervliet et al. This study further shows that in terms of its wear performance, PEEK-OPTIMA™ has promise as an alternative bearing material to cobalt chrome in the femoral component of total knee replacements


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 39 - 39
7 Aug 2023
Hainsworth L Lankester B
Full Access

Abstract. Introduction. Isolated patellofemoral osteoarthritis accounts for 10% of knee osteoarthritis. Many of these will not require arthroplasty solutions, but for those who are sufficiently symptomatic, patellofemoral joint (PFJ) replacement has been shown to be an effective procedure. The National Joint Registry (NJR) has shown a higher revision rate for this operation, particularly in younger patients (males <55 years 13.3% failure at 5 years, females 9.6%). The aim of this study is to report on the medium-term outcome of the Avon patellofemoral joint arthroplasty in patients under 55 from a non-design centre. There is no other published case series on this young patient cohort. Methodology. 50 Avon PFJ replacements (Stryker, Kalamazoo USA) were undertaken in 46 patients under 55 years old (range 35 – 54, mean 48.8) between 2010 and 2022 for end-stage isolated PFJ arthritis shown on Xray and MRI scan. The outcome measure was all-cause revision rate. This was assessed by review of clinical notes, imaging and NJR data. Results. The mean follow up was 5.8 years (range 6 months to 12.9 years). Only one patient had a revision procedure (for progressive osteoarthritis) which was 3 years after the primary procedure. This patient has had no further surgery. The implant survival rate was 97.2% at 5 years and 97.2% at 10 years. Conclusion. This study shows that patellofemoral joint replacement with the Avon prosthesis can give a satisfactory revision rate in the medium term in patients under 55 if carefully selected


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 46 - 46
1 Mar 2009
Iranpour F Cobb J Amis A
Full Access

Introduction: The normal relationships of the patellofemoral joint provide a basis for the evaluation of patients with patellofemoral abnormalities. Previous studies have often described the patellofemoral joint using X-rays which are encumbered with projectional inaccuracies. We have used CT to describe the geometry of this joint and its relationship to the tibiofemoral joint in terms of angles and distances. Materials and method: 33 patients had a CT scan prior to medial unicompartmental knee replacement. These patients have minimum patellofemoral joint disease. Special software was used to convert the scans to 3D and measure the distances and angles. The flexion axis of the tibiofemoral joint was found as the line connecting the centres of the spheres fitted to posterior femoral condyles. These two centres and femoral head centre form a frame of reference for reproducible femoral alignment. The trochlear geometry was defined by fitting circles and spheres to slices and surfaces, then constructing an axis through their centres. The geometry of the patella was established by fitting two planes to the proximal and anterior extra-articular surfaces of the patella. The relationships between these planes and the rest of the patella were explored. Results: The deepest points on the trochlear groove can be fitted to a circle with radius of 23mm (stdev 4mm) and an rms of 0.3mm. This centre is offset by 21mm (stdev 3mm) at an angle of 68° (stdev 8°) from the line connecting the midpoint between the centres of the femoral condyles and a point in the piriform fossa. On either end of this line, the articular surface of the trochlea can be fitted to spheres of radius 30mm (stdev 6mm) laterally and 27mm (stdev 5mm) and an rms of 0.4mm medially. The centres of the circle and the two spheres fall on a line with an rms of 1.1mm. The anterior and proximal patellar planes could be described as flat surfaces (rms of 0.4 and 0.3mm). The median ridge could be described as a straight line (rms of 0.2mm). The angle between planes was 112° (stdev 5°); the average angle between the proximal plane and the line on the medial ridge was 62° (stdev4°). The functional centre of the patella was defined as a point in the centre of 2 planes orthogonal to the sagital plane from the midpoint between the most proximal and most distal points on the median ridge. The length, width and thickness of the patellae were measured at 22mm +/−4mm, 47mm +/− 3mm and 24 mm+/− 2 mm. Discussion: This investigation has allowed us to characterise the patello-femoral joint geometry. The knowledge of the shapes of the surfaces of this joint and their relationships may help identify and explain the aetiology of patello-femoral dyplasia and other pathologies. It may also be of use in planning and performing joint reconstruction and may have implications for the design of patello-femoral replacements and the rules governing their position


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 154 - 154
1 Jan 2016
Kim H Seon J Seol J Kim G Yoo S
Full Access

Background. Despite the excellent clinical success of total knee arthroplasty (TAK), controversy remains concerning whether or not to resurface the patella. This has led to a number of randomized controlled trials. Randomized controlled trials constitute the most reliable source of evidence for the evaluation of the efficacy of a potential intervention. But most of these studies include all degree of osteoarthritis of the patellofemoral joint. So we did this prospective study to compare clinical and radiological outcomes after TKA with or without patellar resurfacing in patients with grade IV osteoarthritis on patellofemoral joint. Materials and Methods. 123 cases (93 patients) with Kellgren-Lawrence grade IV osteoarthritis on patellofemoral joint were enrolled for this study. At the operating room, they were randomly assigned to undergo patella resurfacing (62 cases) or patella retention (61 cases). Among them, 114 cases that could be followed for more than 2 years were included in this study (resurfacing group; 59 cases, retention group; 55 cases). When patellar retention was performed, osteophytes of the patella were removed and marginal electrocauterization was carried out. Preoperative and postoperative clinical outcomes were evaluated and compared regarding the Hospital for Special Surgery Patellar (HSSP) score (total 100 point; anterior knee pain, functional limitation, tenderness, crepitus, Q-strength). We also compared Hospital for Special Surgery (HSS) and WOMAC scores, and range of motion (ROM). We also compared radiological outcomes at the final follow up, with regards to mechanical axis of the lower limb, patella tilt and patella congruence angle between two groups. Results. Average HSSP score was 85 in resurfacing group, 83 in retention group, which were showing no significant differences between groups (p=.75). Anterior knee pain subscale also showed no significant differences between groups (40 in resurfacing group, 36 in retention group, p= 0.52). HSS score improved to 94 points in resurfacing group and 95 points in retention group showing no significant difference (p=.92). While WOMAC score and range of motion was 32 point and 128°±10.5° in resurfacing group, respectively, they were 29 point and 126°±11.5° in retention group, without significant inter-group difference (p>.05). There were no differences between two groups in mechanical axis of the lower limb and patella tilt, patella congruence (p>0.05). Conclusion. Clinical and radiological outcomes were ‘good’ after TKA with or without patellar resurfacing in patients with high grade osteoarthritis of the patellofemoral joint without significant differences. Thus, this study suggested that TKA without patellar resurfacing is a good treatment option in patients with high grade osteoarthritis of the patellofemoral joint


Full Access

Abstract. INTRODUCTION. 10% of patients with knee osteoarthritis (OA) have disease confined to the patellofemoral joint (PFJ). The main surgical options are total knee replacement (TKR) and PFJ replacement (PFJR). PFJR has advantages over TKR, including being less invasive, bone preserving, allowing faster recovery and better function and more ‘straight forward’ revision surgery. We aim to compare the clinical results of revised PFJR with primary TKR taking into consideration the survival length of the PFJR. METHODOLOGY. Twenty-five patients (21 female) were retrospectively identified from our arthroplasty database who had undergone revision from PFJR to TKR (2006–2019). These patients were then matched with regards to their age at their primary procedure, sex and total arthroplasty life (primary PFJ survival + Revision PFJ time to follow up) up to point of follow-up with a group of primary TKRs implanted at the same point as the primary PFJR. RESULTS. Mean survival of the PFJs revised were 4.2 years. In the PFJR revision group (mean arthroplasty life 7.8 years) mean Oxford knee score (OKS) at latest follow up was 27.8. In the primary knee group (mean arthroplasty life 7.5 years) mean OKS was 32.4. This difference was not statistically significant. All PFJR revisions were performed using primary prostheses. CONCLUSION. PFJR provides comparable clinical outcome even after revision surgery to TKR as primary TKRs at midterm follow up and should be considered in all patients meeting the selection criteria. Given comparable proms and straight forward revisions, staged arthroplasty to preserve bone-stock is a reasonable choice


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 56 - 60
1 Jan 2010
Odumenya M Costa ML Parsons N Achten J Dhillon M Krikler SJ

Between May 1998 and May 2007 we carried out 50 Avon patellofemoral joint replacements in 32 patients with isolated patellofemoral osteoarthritis. There were no revisions in the first five years, giving a cumulative survival of 100% for those with a minimum follow-up of five years. The mean follow-up was 5.3 years (2.1 to 10.2). The median Oxford knee score was 30.5 (interquartile range 22.25 to 42.25). In patients with bilateral replacements the median Euroqol General health score was 50 which was significantly lower than that of 75 in those with a unilateral replacement (p = 0.047). The main complication was progression of disease, which was identified radiologically in 11 knees (22%). This highlights the need for accurate selection of patients. Our findings suggest that the Avon prosthesis survives well and gives a satisfactory functional outcome in the medium term


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 408 - 412
1 Mar 2007
Ma H Lu Y Kwok T Ho F Huang C Huang C

One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines. The Total Condylar prosthesis had the lowest conformity with the native patella (mean 8.58°; 0.14° to 29.9°) and with its own patellar component (mean 11.36°; 0.55° to 39.19°). In the other four prostheses, the conformity was better (mean 2.25°; 0.02° to 10.52°) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity (mean 6.51°; 0.07° to 9.89°) than the Miller-Galante II prosthesis (mean 11.20°; 5.80° to 16.72°) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid (mean 3.57°; 1.40° to 4.56°) or high angles of flexion (mean 4.54°; 0.91° to 9.39°), respectively. The Low Contact Stress femoral component had the best conformity with the native patella (mean 2.39°; 0.04° to 4.56°). There was no significant difference (p > 0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion. The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 892 - 897
1 Sep 2024
Mancino F Fontalis A Kayani B Magan A Plastow R Haddad FS

Advanced 3D imaging and CT-based navigation have emerged as valuable tools to use in total knee arthroplasty (TKA), for both preoperative planning and the intraoperative execution of different philosophies of alignment. Preoperative planning using CT-based 3D imaging enables more accurate prediction of the size of components, enhancing surgical workflow and optimizing the precision of the positioning of components. Surgeons can assess alignment, osteophytes, and arthritic changes better. These scans provide improved insights into the patellofemoral joint and facilitate tibial sizing and the evaluation of implant-bone contact area in cementless TKA. Preoperative CT imaging is also required for the development of patient-specific instrumentation cutting guides, aiming to reduce intraoperative blood loss and improve the surgical technique in complex cases. Intraoperative CT-based navigation and haptic guidance facilitates precise execution of the preoperative plan, aiming for optimal positioning of the components and accurate alignment, as determined by the surgeon’s philosophy. It also helps reduce iatrogenic injury to the periarticular soft-tissue structures with subsequent reduction in the local and systemic inflammatory response, enhancing early outcomes. Despite the increased costs and radiation exposure associated with CT-based navigation, these many benefits have facilitated the adoption of imaged based robotic surgery into routine practice. Further research on ultra-low-dose CT scans and exploration of the possible translation of the use of 3D imaging into improved clinical outcomes are required to justify its broader implementation. Cite this article: Bone Joint J 2024;106-B(9):892–897


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 426 - 426
1 Sep 2009
Sharda P Maheswaran S
Full Access

We report the results of patellofemoral joint replacement done at our institution for predominantly patellofemoral arthritis. Patellofemoral joint replacement has always been a controversial subject, particularly in elderly patients where a more predictable result can be obtained with TKA. Patellofemoral joint replacement surgery was commenced at our institute in 2002 using the Avon design (Stryker corp, UK,) pioneered at the Avon Orthopaedic centre, Southmead, Bristol, UK. We report retrospective analysis of 43 consecutive Patellofemoral replacements done in 39 patients between 2002 and 2006, with a minimum of 6 months follow-up. 38 patients (5 bilateral) were available for review while 1 patient died 3 years after the operation following unrelated causes. They were all assessed clinically and radiologically on the last follow up. Follow-up ranged from 6 to 56 months, average being 21 months. Females outnumbered males by 3:1. All patients were scored pre and postoperatively using Melbourne Knee scoring system (Bartlett et al) and Knee Functional Score. The average Melbourne Knee score increased from 10 to 25 postoperatively, while the knee functional score increased from 57 to 85. Postoperative flexion ranged from 100–140°, average being 116°. Commonest complication was clicking (17%), half of which resolved by arthroscopic lateral release. 87% patients graded the result as excellent or good, while 2% (1 patient) rated it as poor. 59% patients had radiologically proven early tibiofemoral arthritis preoperatively, out of which progression was noted in 28% at the last follow-up. No complications related to deep infection or loosening were noted, and one knee needed revision on account of progression of lateral compartment arthritis. With revision as the end point, the survivorship was 97.7% at average of 2 years after surgery


Aims. Classifying trochlear dysplasia (TD) is useful to determine the treatment options for patients suffering from patellofemoral instability (PFI). There is no consensus on which classification system is more reliable and reproducible for the purpose of guiding clinicians’ management of PFI. There are also concerns about the validity of the Dejour Classification (DJC), which is the most widely used classification for TD, having only a fair reliability score. The Oswestry-Bristol Classification (OBC) is a recently proposed system of classification of TD, and the authors report a fair-to-good interobserver agreement and good-to-excellent intraobserver agreement in the assessment of TD. The aim of this study was to compare the reliability and reproducibility of these two classifications. Methods. In all, six assessors (four consultants and two registrars) independently evaluated 100 axial MRIs of the patellofemoral joint (PFJ) for TD and classified them according to OBC and DJC. These assessments were again repeated by all raters after four weeks. The inter- and intraobserver reliability scores were calculated using Cohen’s kappa and Cronbach’s α. Results. Both classifications showed good to excellent interobserver reliability with high α scores. The OBC classification showed a substantial intraobserver agreement (mean kappa 0.628; p < 0.005) whereas the DJC showed a moderate agreement (mean kappa 0.572; p < 0.005). There was no significant difference in the kappa values when comparing the assessments by consultants with those by registrars, in either classification system. Conclusion. This large study from a non-founding institute shows both classification systems to be reliable for classifying TD based on axial MRIs of the PFJ, with the simple-to-use OBC having a higher intraobserver reliability score than that of the DJC. Cite this article: Bone Jt Open 2023;4(7):532–538


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 452 - 458
1 May 1999
Stäubli H Dürrenmatt U Porcellini B Rauschning W

We studied the anatomy of the patellofemoral joint in the axial plane on cryosections from a cadaver knee and on MR arthrotomograms from 30 patients. The cryosections revealed differences in the geometry and anatomy of the surface of the articular cartilage and corresponding subchondral osseous contours of the patellofemoral joint. On the MR arthrotomograms the surface geometry of the cartilage matched the osseous contour of the patella in only four of the 30 knees. The articular cartilaginous surface of the intercondylar sulcus and corresponding osseous contour of the femoral trochlea matched in only seven knees. Since MR arthrotomography can distinguish between the surface geometry of the articular cartilage and subchondral osseous anatomy of the patellofemoral joint, it allows the surgeon and the radiologist to appraise the true articulating surfaces. We therefore recommend MR arthrotomography as the imaging technique of choice