Advertisement for orthosearch.org.uk
Results 1 - 20 of 83
Results per page:

Aims. Olecranon fractures are usually caused by falling directly on to the olecranon or following a fall on to an outstretched arm. Displaced fractures of the olecranon with a stable ulnohumeral joint are commonly managed by open reduction and internal fixation. The current predominant method of management of simple displaced fractures with ulnohumeral stability (Mayo grade IIA) in the UK and internationally is a low-cost technique using tension band wiring. Suture or suture anchor techniques have been described with the aim of reducing the hardware related complications and reoperation. An all-suture technique has been developed to fix the fracture using strong synthetic sutures alone. The aim of this trial is to investigate the clinical and cost-effectiveness of tension suture repair versus traditional tension band wiring for the surgical fixation of Mayo grade IIA fractures of the olecranon. Methods. SOFFT is a multicentre, pragmatic, two-arm parallel-group, non-inferiority, randomized controlled trial. Participants will be assigned 1:1 to receive either tension suture fixation or tension band wiring. 280 adult participants will be recruited. The primary outcome will be the Disabilities of the Arm, Shoulder and Hand (DASH) score at four months post-randomization. Secondary outcome measures include DASH (at 12, 18, and 24 months), pain, Net Promotor Score (patient satisfaction), EuroQol five-dimension five-level score (EQ-5D-5L), radiological union, complications, elbow range of motion, and re-operations related to the injury or to remove metalwork. An economic evaluation will assess the cost-effectiveness of treatments. Discussion. There is currently no high-quality evidence comparing the clinical and cost effectiveness of the tension suture repair to the traditional tension band wiring currently offered for the internal fixation of displaced fractures of the olecranon. The Simple Olecranon Fracture Fixation Trial (SOFFT) is a randomized controlled trial with sufficient power and design rigour to provide this evidence for the subtype of Mayo grade IIA fractures. Cite this article: Bone Jt Open 2023;4(1):27–37


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered. Cite this article: Bone Joint J 2023;105-B(2):112–123


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 37 - 37
1 Nov 2022
Patil V Rajan P Tsekes D
Full Access

Abstract. Introduction. Displaced olecranon fractures in the elderly are challenging due to associated comorbidities, poor tissue quality, high risk of complications, and the possible need for implant removal. Treatment options with such fractures range from non-operative management to internal fixation with various types of implants. Currently, there is no consensus on the treatment of olecranon fractures in the elderly with relatively low functional demand. Aim. The aim of this systematic review was to analyse the clinical outcomes of various treatment modalities for olecranon fracture in the elderly. Methods. We systematically reviewed the literature covering the treatment of olecranon fractures in the elderly according to PRISMA guidelines. We used search tools of Medline, Embase, Wiley online library, Cochrane and Scopus. Keywords used in the search were Olecranon fracture and Elderly OR Geriatric in all fields. Studies involving patients older than 60 years of age and all modalities of treatment were included. Results. 14 papers studying 270 patients were identified of which, 112 were treated non-operatively, 25 with limited fixation, 98 with tension band wire fixation, 34 with plate fixation, and 1 patient was treated with excision. Conclusions. Nonoperative as well as limited fixation were shown to provide satisfactory results in the elderly. Treatment decisions in this age group should be individualised to factors such as fracture stability, quality of bone & soft tissues, and patient's functional demand. We recommend a treatment protocol for treating olecranon fracture in the elderly based on the above factors


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 46 - 46
1 Apr 2013
Iga T Karita T Sato W Okazaki H Tatsumi T Touhara C Nishikawa T Nagai I Ushita M Matsumoto T Kondo T
Full Access

Introduction. In oblique olecranon fracture, fracture line begins in the trochlear notch and proceeds distally to the dorsal cortex of the ulna. We have experienced a nonunion of reverse oblique fracture. Hypothesis. Reverse oblique olecranon fracture has instability. Materials & Methods. 130 patients with an olecranon fracture were retrospectively evaluated. Inclusion criteria are that fracture line begins at the base of the coronoid process, distal portion of the trochlear notch, and proceeds proximally to the dorsal cortex of the ulna on the lateral radiograph. Fractures with articular comminution were excluded. Results. Seven patients met the criteria. They were associated with local injuries: anterior translation of the proximal radius and ulna, fracture of the medial epicondyle or the lateral condyle of the humerus. One out of five patients treated with tension band wiring (TBW) was revised with screw fixation because of nonunion. Discussion. The associated injuries suggested the anterior and valgus instability. A nonunion case suggests a requirement of more secure fixation. However, these findings are common in distal olecranon fracture. Therefore, the instability in our series is due to the distal location of fracture on the trochlear notch rather than reverse obliquity. The reverse obliquity attributes to small proximal fragment. Conclusion. Reverse oblique olecranon fracture has instability because of its distal location. It should be distinguished from simple, stable fracture


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 398 - 398
1 Oct 2006
Shoaib A Guha A Balendran R Kuiper J
Full Access

Introduction: Tension band wiring is a common technique for olecranon fracture fixation. The most commonly used material for the tension band is stainless steel wire. There are however problems associated with stainless steel wire. Ethibond (Ethicon Ltd, Edinburgh) has previously been cited as a suitable alternative material but not FiberWire. The biomechanical properties of FiberWire (Arthrex Ltd, Sheffield) as a tension band material have not been evaluated. This study aimed to investigate the properties of FiberWire and compare them with stainless steel wire and Ethibond. Methods: Saw-bone olecranons were osteotomised identically to create an olecranon fracture. Identical tension band constructs were produced using stainless steel wire, Ethibond and FiberWire. The construct was tested by cyclical loading with an ESH dynamic testing machine (Brierley Hill, West Mids). A preload of 5N was applied before cyclical loading at levels up to 200N. The fracture gap was measured with a displacement transducer (Tokyo Sokki Kenkyujo Co, Japan). Results: At loading up to 100N, the stainless steel wire allowed an average fracture gap of 200 micrometers. 5 gauge Ethibond allowed a larger fracture gap of 350 micrometers (p< 0.05). 2 gauge Fiberwire did not allow a significantly different fracture gap to Ethibond. Discussion: The fracture gap with suture material was greater than with stainless steel wire, but still less then 0.5mm with loading of 100N. Free body diagram calculations determine that in a 70 kg man, this would correspond to the forces expected in extending the elbow against gravity. This means that these alternative materials are mechanically suitable for use in clinical practice for tension bands. This can avoid some of the complications of stainless steel wire. Conclusion: 5 gauge Ethibond and 2 gauge FiberWire are biomechanically suitable as alternatives to stainless steel wire in tension band wire fixation of olecranon fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 627 - 635
1 Jul 1994
Papagelopoulos P Morrey B

We report the results in 24 consecutive patients treated from 1976 to 1991 for nonunion of olecranon fractures. Their mean age was 42 years, and the mean interval from fracture to treatment for nonunion was 19 months. Management was by rehabilitation and activity as tolerated for three, continued immobilisation for one, and operative treatment for 20. Operations included excision of the olecranon fragment (1), osteosynthesis (16), and joint replacement (3). Four patients also had distraction arthroplasty. At a mean follow-up of 18 months no patient had severe residual elbow pain but three had moderate and six had mild symptoms. The mean arc of motion was 98 degrees representing an average improvement of 11 degrees. Twelve patients had an excellent result, four good, six fair, and two a poor result. Union had been achieved in 15 of the 16 patients treated by osteosynthesis


Bone & Joint 360
Vol. 13, Issue 1 | Pages 26 - 29
1 Feb 2024

The February 2024 Shoulder & Elbow Roundup. 360. looks at: Does indomethacin prevent heterotopic ossification following elbow fracture fixation?; Arthroscopic capsular shift in atraumatic shoulder joint instability; Ultrasound-guided lavage with corticosteroid injection versus sham; Combined surgical and exercise-based interventions following primary traumatic anterior shoulder dislocation: a systematic review and meta-analysis; Are vascularized fibula autografts a long-lasting reconstruction after intercalary resection of the humerus for primary bone tumours?; Anatomical versus reverse total shoulder arthroplasty with limited forward elevation; Tension band or plate fixation for simple displaced olecranon fractures?; Is long-term follow-up and monitoring in shoulder and elbow arthroplasty needed?


Aims. Compression and absolute stability are important in intra-articular fractures such as transverse olecranon fractures. This biomechanical study aims to compare tension band wiring (TBW) with plate fixation by measuring compression within the fracture. Methods. A cross-over design and synthetic ulna models were used to reduce variation between samples. Identical transverse fractures were created using a 0.5mm saw blade and cutting jig. A Tekscan(tm) force transducer was calibrated and placed within the fracture gap. Twenty TBW or Acumed(tm) plate fixations were performed according to the recommended technique. Compression was measured while the constructs were static and during simulated elbow range of movement exercises. Dynamic testing was performed using a custom jig reproducing cyclical triceps contraction of 20N and reciprocal brachialis contraction of 10N. Both fixation methods were tested on each sample. Half were randomly allocated to TBW first and half to plating first. Data was recorded using F-scan (v 5.72) and analysed using SPSS(tm) (v 16). Paired T-tests compared overall compression and compression at the articular side of the fracture. Results. The mean overall compression for plating was 819N (+/− 602N 95%CI), TBW overall compression: 77N (+/−19N 95%CI) (P=0.039). Articular side compression for plating: 343N (+/− 276N 95%CI), TBW: 1N (+/− 2N 95%CI). (P=0.038). During simulated movements, overall compression reduced in both groups: TBW -14N (+/−7N) Plating -173N (+/−32N) and no increase in articular side compression was detected in the TBW group. Conclusion. Precontoured plates such as the Acumed(tm) olecranon system can provide significantly greater compression, compared to TBW in transverse olecranon fractures. This was significant for compression over the whole fracture surface and specifically at the articular side of the fracture. Also, in TBW, overall compression reduced and articular side compression remained negligible during simulated triceps contraction, challenging the tension band principle


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 95 - 95
1 May 2012
Molony DC Kennedy J Gheiti AC Mullett JH
Full Access

Background. The treatment of olecranon fractures frequently involves the use of tension band fixation. Although associated with high union rates, this method has a high incidence of morbidity associated with soft tissue compromise and limitation of range of movement requiring frequent re-operation for removal of metal. Objectives. We describe the use of a simple jig to ensure intramedullary placement of longitudinal K-wires and compare the accuracy of placement of wires using this device with the traditional free hand method. Methods & Materials. 10 orthopaedic surgical trainees passed 2 longitudinal k wires into synthetic ulnae. This was done using the free hand method and then plastic jig. The ulnae were then sectioned to identify the position of the wires relative to the intramedullary canal. Results. Of the free hand wires, only 11 of 20 were found to be intramedullary versus 20 of 20 in the group passed using the jig. (p<0.001). The mean distance from the center of the ulnar canal was 6.5 mm in the freehand group (range 1-18mm, SD 6.1mm) and 1.6 mm in the O-Jig group (range 1-2mm, SD 0.5mm). The difference in the mean distance from the centre was 4.9mm which was significant (p< 0.001). Conclusions. We found the distance from the centre of the medullary canal, the range and standard deviations of wire positions to be significantly more precise when the jig was used


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 530 - 534
1 Apr 2014
Gallucci GL Piuzzi NS Slullitel PAI Boretto JG Alfie VA Donndorff A De Carli P

We retrospectively evaluated the clinical and radiological outcomes of a consecutive cohort of patients aged > 70 years with a displaced fracture of the olecranon, which was treated non-operatively with early mobilisation. We identified 28 such patients (27 women) with a mean age of 82 years (71 to 91). The elbow was initially immobilised in an above elbow cast in 90° of flexion of the elbow for a mean of five days. The cast was then replaced by a sling. Active mobilisation was encouraged as tolerated. No formal rehabilitation was undertaken. At a mean follow-up of 16 months (12 to 26), the mean ranges of flexion and extension were 140° and 15° respectively. On a visual analogue scale of 1 (no pain) to 10, the mean pain score was 1 (0 to 8). Of the original 28 patients 22 developed nonunion, but no patients required surgical treatment.

We conclude that non-operative functional treatment of displaced olecranon fractures in the elderly gives good results and a high rate of satisfaction.

Cite this article: Bone Joint J 2014;96-B:530–4.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 964 - 972
1 Jul 2017
Duckworth AD Clement ND McEachan JE White TO Court-Brown CM McQueen MM

Aims

The aim of this prospective randomised controlled trial was to compare non-operative and operative management for acute isolated displaced fractures of the olecranon in patients aged ≥ 75 years.

Patients and Methods

Patients were randomised to either non-operative management or operative management with either tension-band wiring or fixation with a plate. They were reviewed at six weeks, three and six months and one year after the injury. The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at one year.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 367 - 372
1 May 1985
Fyfe I Mossad M Holdsworth B

This study was designed to compare the rigidity of the more commonly used techniques of internal fixation of fractures of the olecranon. Cadaveric elbow joints were mounted in a jig and controlled osteotomies performed to simulate transverse, oblique or comminuted fractures. Five techniques of internal fixation were tested by measuring movement at the fracture site after applying a bending moment to the ulna. At transverse osteotomies tension-band wiring with two tightening knots allowed least movement even at high loads. Intramedullary cancellous screw fixation gave erratic results; adding a tension band with a single know was little better. In oblique osteotomies, no statistically significant difference was shown between one-third tubular plate fixation and double-knot wiring. Comminuted osteotomies were held most rigidly by contoured one-third tubular plate fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 315 - 319
1 Feb 2010
Lalliss SJ Branstetter JG

Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied using an Instron materials testing machine whilst monitoring the osteotomy site with a video extensometer. Each osteotomy was repaired by one of four materials, namely, Stainless Steel Wire (7), No 2 Ethibond (3), No 5 Ethibond (5), or No 2 FiberWire (7).

There were no failures (movement of > 2 mm) with stainless steel wire or FiberWire and no significant difference in the movements measured across the site of the osteotomy (p = 0.99). The No. 2 Ethibond failed at 450 N and two of the five of No. 5 Ethibond sutures had a separation of > 2 mm at 450 N.

FiberWire as the tension band in this model held the reduction as effectively as stainless steel wire and may reduce the incidence of discomfort from the hardware. On the basis of our findings we suggest that a clinical trial should be undertaken


Bone & Joint 360
Vol. 10, Issue 5 | Pages 12 - 13
1 Oct 2021


Bone & Joint Open
Vol. 1, Issue 7 | Pages 376 - 382
10 Jul 2020
Gill JR Vermuyten L Schenk SA Ong JCY Schenk W

Aims. The aim of this study is to report the results of a case series of olecranon fractures and olecranon osteotomies treated with two bicortical screws. Methods. Data was collected retrospectively for all olecranon fractures and osteotomies fixed with two bicortical screws between January 2008 and December 2019 at our institution. The following outcome measures were assessed; re-operation, complications, radiological loss of reduction, and elbow range of flexion-extension. Results. Bicortical screw fixation was used to treat 17 olecranon fractures and ten osteotomies. The mean age of patients being treated for olecranon fracture and osteotomy were 48.6 years and 52.7 years respectively. Overall, 18% of olecranon fractures were classified as Mayo type I, 71% type II, and 12% type III. No cases of fracture or osteotomy required operative re-intervention. There were two cases of loss of fracture reduction which occurred in female patients ≥ 75 years of age with osteoporotic bone. In both cases, active extension and a functional range of movement was maintained and so the loss of reduction was managed non-operatively. For the fracture fixation cohort, at final follow-up mean elbow extension and flexion were -5. °. ± 5. °. and 136. °. ± 7. °. , with a mean arc of motion of 131. °. ± 11. °. . Conclusion. This series has shown that patients regain near full range of elbow flexion-extension and complication rates are low following bicortical screw fixation of olecranon fractures and osteotomy. Cite this article: Bone Joint Open 2020;1-7:376–382


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 17 - 17
1 Dec 2022
Smit K L'Espérance C Livock H Tice A Carsen S Jarvis J Kerrigan A Seth S
Full Access

Olecranon fractures are common injuries representing roughly 5% of pediatric elbow fractures. The traditional surgical management is open reduction and internal fixation with a tension band technique where the pins are buried under the skin and tamped into the triceps. We have used a modification of this technique, where the pins have been left out of the skin to be removed in clinic. The purpose of the current study is to compare the outcomes of surgically treated olecranon fractures using a tension-band technique with buried k-wires (PINS IN) versus percutaneous k-wires (PINS OUT). We performed a retrospective chart review on all pediatric patients (18 years of age or less) with olecranon fractures that were surgically treated at a pediatric academic center between 2015 to present. Fractures were identified using ICD-10 codes and manually identified for those with an isolated olecranon fracture. Patients were excluded if they had polytrauma, metabolic bone disease, were treated non-op or if a non-tension band technique was used (ex: plate/screws). Patients were then divided into 2 groups, olecranon fractures using a tension-band technique with buried k-wires (PINS IN) and with percutaneous k-wires (PINS OUT). In the PINS OUT group, the k-wires were removed in clinic at the surgeon's discretion once adequate fracture healing was identified. The 2 groups were then compared for demographics, time to mobilization, fracture healing, complications and return to OR. A total of 35 patients met inclusion criteria. There were 28 patients in the PINS IN group with an average age of 12.8 years, of which 82% male and 43% fractured their right olecranon. There were 7 patients in the PINS OUT group with an average age of 12.6 years, of which 57% were male and 43% fractured their right olecranon. All patients in both groups were treated with open reduction internal fixation with a tension band-technique. In the PINS IN group, 64% were treated with 2.0 k-wires and various materials for the tension band (82% suture, 18% cerclage wire). In the PINS OUT group, 71% were treated with 2.0 k-wires and all were treated with sutures for the tension band. The PINS IN group were faster to mobilize (3.4 weeks (range 2-5 weeks) vs 5 weeks (range 4-7 weeks) p=0.01) but had a significantly higher complications rate compared to the PINS OUT group (6 vs 0, p =0.0001) and a significantly higher return to OR (71% vs 0%, p=0.0001), mainly for hardware irritation or limited range of motion. All fractures healed in both groups within 7 weeks. Pediatric olecranon fractures treated with a suture tension-band technique and k-wires left percutaneously is a safe and alternative technique compared to the traditional buried k-wires technique. The PINS OUT technique, although needing longer immobilization, could lead to less complications and decreased return to the OR due to irritation and limited ROM


Bone & Joint 360
Vol. 13, Issue 4 | Pages 26 - 29
2 Aug 2024

The August 2024 Shoulder & Elbow Roundup. 360. looks at: Comparing augmented and nonaugmented locking-plate fixation for proximal humeral fractures in the elderly; Elevated five-year mortality following shoulder arthroplasty for fracture; Total intravenous anaesthesia with propofol reduces discharge times compared with inhaled general anaesthesia in shoulder arthroscopy: a randomized controlled trial; The influence of obesity on outcomes following arthroscopic rotator cuff repair; Humeral component version has no effect on outcomes following reverse total shoulder arthroplasty: a prospective, double-blinded, randomized controlled trial; What is a meaningful improvement after total shoulder arthroplasty by implant type, preoperative diagnosis, and sex?; The safety of corticosteroid injection prior to shoulder arthroplasty: a systematic review; Mortality and subsequent fractures of patients with olecranon fractures compared to other upper limb osteoporotic fractures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 139 - 139
11 Apr 2023
Jeong S Suh D Park J Moon J
Full Access

Olecranon plates used for the internal fixation of complex olecranon fractures are applied directly over the triceps tendon on the posterior aspect of the olecranon. The aim of the study is to describe the relationship of the plates and screws to the triceps tendon at the level of the olecranon. Eight cadaveric elbows were used. Dimensions of the triceps tendon at the insertion and 1cm proximal were measured. A long or a short olecranon plate was then applied over the olecranon and the most proximal screw applied. The length of the plate impinging on the tendon and the level of the screw tract on the tendon and bone were measured. The mean olecranon height was 24.3cm (22.4-26.9cm) with a tip-to-tendon distance of 14.5cm (11.9-16.2cm). The triceps tendon footprint averaged 13.3cm (11.7-14.9cm) and 8.8cm (7.6-10.2cm) in width and length, respectively. The mean width of the central tendon 1 cm proximal to the footprint was 6.8 cm. The long olecranon plate overlay over more movable tendon length than did the short plate and consequently the superior screw pierced the triceps tendon more proximally with the long plate. Using the Mann-Whitney U test, the differences were significant. The long olecranon plates encroach on more triceps tendon than short plates. This may be an important consideration for olecranon fractures with regards implant loosening or triceps tendon injury


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 4 - 4
1 May 2021
Nicholson JA Oliver WM Gillespie M Simpson AHRW White TO Duckworth AD
Full Access

Non-operative management of displaced olecranon fractures in elderly low demand patients is reported to result in a satisfactory outcome despite routinely producing a nonunion. The aim of this study was to assess whether there is evidence of dynamic movement of the fracture fragment during the elbow arc of movement. Five consecutive patients (≥70 years of age) with a displaced olecranon fracture (Mayo 2A) that were managed with non-operative intervention were recruited. All underwent ultrasound evaluation at six weeks and follow-up questionnaires at six months including the DASH and Oxford Elbow Score (OES). There were three women and two men with a mean age of 79yrs (range 70–88). All injuries were sustained following a fall from standing height. The mean fracture gap in extension was 22.5mm (95% CI 13.0–31.9), midflexion 21.8mm (11.6–32.0) and in deep flexion 21.8mm (10.9–32.8). Although the amount of fracture displacement varied between patients, it remained static in each patient with no significant differences observed throughout the arc of motion (ANOVA p=0.99). The six-month median DASH score was 7.5 (IQR range, 4.2–39.3) and the OES was 44.0 (29.0–47.5). Four out of the five patients were satisfied with their function. Ultrasound evaluation of displaced olecranon fractures following non-operative management suggests the proximal fragment may function as a sesamoid type bone within the triceps sleeve. This could explain how a functional arc of movement with a minimum level of discomfort can usually be expected with non-operative management in select patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 69 - 69
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Bispo C
Full Access

Radial head fractures are among the most common fractures around the elbow. Radial head arthroplasty is one of the surgical treatment options after complex radial head fractures. This surgery is usually done under general anaesthesia. However, there is a recent anaesthetic technique - wide awake local anaesthesia no tourniquet (WALANT) - that has proven useful in different surgical settings, such as in distal radius or olecranon fractures. It allows a good haemostatic control without the use of a tourniquet and allows the patient to actively collaborate during the surgical procedure. Furthermore, there are no side effects or complications caused by the general anaesthesia and there's an earlier patient discharge. The authors present the case of a seventy-six-year-old woman who presented to the emergency department after a fall from standing height with direct trauma to the left elbow. The radiological examination revealed a complete intra-articular comminuted fracture of the radial head (Mason III). Clinical management: The patient was submitted to surgery with radial head arthroplasty, using WALANT. The surgery was successfully completed without pain. There were no intra or immediate post-operative complications and the patient was discharged on the same day. Six weeks after surgery, the patient had almost full range of motion and was very pleased with the functional outcome, with no limitations on her activities of daily living. The use of WALANT has been expanded beyond the hand and wrist surgery. It is a safe and simple option for patients at high risk of general anaesthesia, allowing similar surgical outcomes without the intraoperative and postoperative complications of general anaesthesia and permitting an earlier hospital discharge. Furthermore, it allows the patient to actively collaborate during the surgery, providing the surgeons the opportunity to evaluate active mobility and stability, permitting final corrections before closing the incision