Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 6 - 6
1 Apr 2013
Sakagoshi D Sawaguchi T Shima Y Inoue D Oshima T Goldhahn S
Full Access

Introduction. Tip apex distance (TAD) is reported as a predictor for cut outs of lag screws in the treatment of intertrochanteric fractures, and surgeons are adviced to strive for TAD within 20 mm. However the definition of neck axis and the limb position of lateral radiograph are not clearly described in the original literature. We propose the refined TAD by defining these factors. The objective of this study was to analyze the interobserver agreement of this refined TAD. Materials and Method. X rays of 130 cases of unstable trochanteric fractures were used for the analysis of the refined TAD. In the refined TAD, neck axis was defined as the line between the center of femoral head and midpoint of narrowest part of the femoral neck, and lateral radiograph was taken with hip flexion 90 degrees and abduction 45 degrees. The refined TAD was independently measured by 2 experienced (observer 1,2) and 2 inexperienced (observer 3,4) orthopaedic surgeons who were trained with the new method before the measurement. Intraclass correlation coefficient (ICC [2,4]) was calculated to assess the interobserver agreement. Result. The mean refined TADs were 18.2:18.4:18.2:18.2 for observer 1:2:3:4. There was a strong correlation among all four observers (ICC 0.998, (95% CI: 0.998, 0.999). Discussion. Regardless of the clinical experience of observers, the refined TAD is a reliable tool and can be used to develop new TAD recommendations for predicting failure of fixation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 29 - 29
1 Sep 2012
Bajada S Harrison P Mofidi A Richardson J
Full Access

Introduction

Regenerative medicine is a rapidly expanding discipline. However due to a lack of validated outcome measures, clinical trials have been far few. This study aims to assess the validity, inter-observer reliability and intra-observer reproducibility of experimental fracture healing assessment on plain radiographies. This technique involves implantation of mesenchymal stem cell (MSC) seeded constructs on only one side of the fracture after randomisation.

Methods

We examined inter/intraobserver agreement on the area and “bridging length” of callus formed on opposite sides of the fracture. Among 16 orthopaedic surgeons with trauma commitments (8 consultants, 8 registrars) on two separate occasions (average 52 days apart). They independently assessed the radiographs (AP or lateral) of 28 patients with fractures of the tibial or femoral shaft. The fractures chosen included non-unions treated with MSC/constructs and fresh fractures at 4–9 months. For each radiograph the assessor assigned which side (medial or lateral) is there more callus. Chase-corrected agreement using Fleiss kappa was used to compare opinions. Digital analysis software (Image-J) was used to quantify extent/bridging callus and correlate it with surgeons opinion.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 8 - 8
10 Oct 2023
Leow J Oliver W Bell K Molyneux S Clement N Duckworth A
Full Access

To develop a reliable and effective radiological score to assess the healing of isolated ulnar shaft fractures (IUSF), the Radiographic Union Score for Ulna fractures (RUSU). Initially, 20 patients with radiographs six weeks following a non-operatively managed ulnar shaft fracture were selected and scored by three blinded observers. After intraclass correlation (ICC) analysis, a second group of 54 patients with radiographs six weeks after injury (18 who developed a nonunion and 36 who united) were scored by the same observers. In the initial study, interobserver and intraobserver ICC were 0.89 and 0.93, respectively. In the validation study the interobserver ICC was 0.85. The median score for patients who united was significantly higher than those who developed a nonunion (11 vs 7, p<0.001). A ROC curve demonstrated that a RUSU ≤8 had a sensitivity of 88.9% and specificity of 86.1% in identifying patients at risk of nonunion. Patients with a RUSU ≤8 (n = 21) were more likely to develop a nonunion (n = 16/21) than those with a RUSU ≥9 (n = 2/33; OR 49.6, 95% CI 8.6–284.7). Based on a PPV of 76%, if all patients with a RUSU ≤8 underwent fixation at 6-weeks, the number of procedures needed to avoid one nonunion would be 1.3. The RUSU shows good interobserver and intraobserver reliability and is effective in identifying patients at risk of nonunion six weeks after fracture. This tool requires external validation but may enhance the management of patients with isolated ulnar shaft fractures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_6 | Pages 2 - 2
20 Mar 2023
Brennan C Slevin Z Savaridas T
Full Access

The suprascapular nerve is an ideal target for nerve blockade to alleviate shoulder pain given its widespread innervation to the shoulder girdle. Many techniques have been described. To widen the availability of this treatment we investigate whether an anatomical landmark technique can be easily learned by novice injectors to provide efficacious blockade. Five injectors were recruited with varying experience; from the novice medical student to an orthopaedic consultant. Five torsos (10 shoulders) were used. A single page of written instruction and illustration of the Dangoisse landmark technique was provided prior to injection of a Thiel embalmed cadaver bilaterally. A pre-mixed injectate with blue dye was used. Cadavers were dissected and the presence or absence of dye staining reported by 3 observers and a consensus agreement reached. Dissection demonstrated diffuse staining in the suprascapular fossa. 90% of shoulders were found to have adequate staining of the suprascapular nerve directly, or its distal branches, in a manner which would provide adequate anaesthesia. The inter-observer agreement was good (k = 0.73) for staining at the supraspinous fossa and excellent (k=0.87) for staining distally. The technique was easily performed by novice injectors with a 100% success rate. We demonstrate that this technique is reproducible by a range of clinicians to effectively provide anaesthesia of the SScN. The main risks are ineffective block (10% in this series) and of intravascular injection. Within a resource strained healthcare environment greater uptake of this technique is likely to be of benefit to a wider array of patients


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1300 - 1306
1 Oct 2019
Oliver WM Smith TJ Nicholson JA Molyneux SG White TO Clement ND Duckworth AD

Aims. The primary aim of this study was to develop a reliable, effective radiological score to assess the healing of humeral shaft fractures, the Radiographic Union Score for HUmeral fractures (RUSHU). The secondary aim was to assess whether the six-week RUSHU was predictive of nonunion at six months after the injury. Patients and Methods. Initially, 20 patients with radiographs six weeks following a humeral shaft fracture were selected at random from a trauma database and scored by three observers, based on the Radiographic Union Scale for Tibial fractures system. After refinement of the RUSHU criteria, a second group of 60 patients with radiographs six weeks after injury, 40 with fractures that united and 20 with fractures that developed nonunion, were scored by two blinded observers. Results. After refinement, the interobserver intraclass correlation coefficient (ICC) was 0.79 (95% confidence interval (CI) 0.67 to 0.87), indicating substantial agreement. At six weeks after injury, patients whose fractures united had a significantly higher median score than those who developed nonunion (10 vs 7; p < 0.001). A receiver operating characteristic curve determined that a RUSHU cut-off of < 8 was predictive of nonunion (area under the curve = 0.84, 95% CI 0.74 to 0.94). The sensitivity was 75% and specificity 80% with a positive predictive value (PPV) of 65% and a negative predictive value of 86%. Patients with a RUSHU < 8 (n = 23) were more likely to develop nonunion than those with a RUSHU ≥ 8 (n = 37, odds ratio 12.0, 95% CI 3.4 to 42.9). Based on a PPV of 65%, if all patients with a RUSHU < 8 underwent fixation, the number of procedures needed to avoid one nonunion would be 1.5. Conclusion. The RUSHU is reliable and effective in identifying patients at risk of nonunion of a humeral shaft fracture at six weeks after injury. This tool requires external validation but could potentially reduce the morbidity associated with delayed treatment of an established nonunion. Cite this article: Bone Joint J 2019;101-B:1300–1306


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 178 - 183
1 Jan 2021
Kubik JF Rollick NC Bear J Diamond O Nguyen JT Kleeblad LJ Wellman DS Helfet DL

Aims. Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Methods. Three observers reviewed 213 bilateral lower limb CT scans of uninjured ankles. Multiple measurements were recorded on the axial CT 1 cm above the plafond: anterior syndesmotic distance; posterior syndesmotic distance; central syndesmotic distance; fibular rotation; and sagittal fibular translation. Previously studied malreduction standards were evaluated on bilateral CT, including differences in: anterior, central and posterior syndesmotic distance; mean syndesmotic distance; fibular rotation; sagittal translational distance; and syndesmotic area. Unilateral CT was used to compare the anterior to posterior syndesmotic distances. Results. A difference of anterior to posterior syndesmotic distance > 2 mm was observed in 89% of ankles (n = 190) on unilateral CT assessment. Using bilateral CT, we found that 35% (n = 75) of normal ankles would be considered malreduced by current malreduction parameters. In 50 patients (23%), only one parameter was anomalous, 18 patients (8%) had two positive parameters and seven patients (3%) had three. Difference in fibular rotation had the lowest false positive rate of all parameters at 6%, whereas posterior syndesmotic distance difference had the highest at 15%. Conclusion. In this study, 35% of native, uninjured syndesmoses (n = 75) would be classified as malreduced by current diagnostic standards on bilateral CT and 89% had an asymmetric incisura on unilateral CT (n = 190). Current radiological parameters are insufficient to differentiate mild inherent anatomical asymmetry from malreduction of the syndesmosis. Cite this article: Bone Joint J 2021;103-B(1):178–183


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 6 - 6
1 May 2018
Abdelhaq A Walker E Sanghrajka A
Full Access

Background. Disruption of the normal relationship between the proximal tibia and fibula is seen in a number of different conditions such as skeletal dysplasias and post-infective deformity, as well as the consequence of lengthening procedures. Radiographic indices for the tibio-fibular relationship at the ankle have been described, but no similar measures have been reported for the proximal articulation. Aim. The purpose of this study was to investigate the normal radiographic relationship between the proximal tibia and fibula in children to determine the normal range and variation. Methods. Our radiology database was used to identify a sample of 500 normal anteroposterior radiographs of paediatric knees. All radiographs were reviewed by a single observer. The distance from the corner of the lateral tibial plateau to both the proximal tibial (PT) and fibular physes (PF) were measured, and a ratio of the two calculated (PF/PT). The process was repeated with a sample of 100 radiographs by the same observer, and a second independent observer in order to calculate intra-and inter-observer reliability. Results. The age range of patients in this study was 4–16 years, with mean age 12.7. The mean PF/PT ratio was 1.7 (standard deviation 0.2, range 1.3–2.0). Intra-observer reliability was 100% and inter-observer reliability was 97.8%. Conclusion. The results of this study demonstrate that in the normal paediatric knee, there is a consistent relationship between the position of the proximal tibial and fibular physes, with a small range of variation. The PF/PT ratio is a simple and reliable way of assessing the relationship between the proximal tibia and fibula in children, using a standard anteroposterior radiograph. This ratio could be very useful in the diagnosis and planning of surgical management of a number of different causes of tibial and fibular deformities in children


Bone & Joint Research
Vol. 5, Issue 4 | Pages 116 - 121
1 Apr 2016
Leow JM Clement ND Tawonsawatruk T Simpson CJ Simpson AHRW

Objectives. The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison. Methods. A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison. Results. The initial intraclass correlation (ICC) on the first 15 sets of radiographs was 0.67 (95% CI 0.63 to 0.71). However, the original description was being interpreted in different ways. After agreeing on the interpretation, the ICC on the second cohort improved to 0.75. The ICC improved even further to 0.79, when the baseline post-operative radiographs were available for comparison. Conclusion. This study demonstrates that the RUST scoring system is a reliable and repeatable outcome measure for assessing tibial fracture healing. Further improvement in the reliability of the scoring system can be obtained if the radiographs are compared with the baseline post-operative radiographs. Cite this article: Mr J.M. Leow. The radiographic union scale in tibial (RUST) fractures: Reliability of the outcome measure at an independent centre. Bone Joint Res 2016;5:116–121. DOI: 10.1302/2046-3758.54.2000628


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 207 - 207
1 Sep 2012
Chandrasenan J Rajan R Price K
Full Access

The lateral pillar classification (LPC) is a widely used tool in determining prognosis and planning treatment in patients who are in the fragmentation stage of Perthes disease. The original classification has been modified to help increase the accuracy of the classification system by the Herring group. The purpose of our study was to independently assess this modified Herring classification. 35 standardized true antero-posterior radiographs of children in various stages of fragmentation were independently assessed by 6 senior observers on 2 separate occasions (6 weeks apart). Kappa analysis was used to assess the inter and intraobserver agreement between observations made. The degrees of agreement were as follows: poor, fair, moderate, good and very good. Intraobserver analysis revealed at best only moderate agreement for two observers. 3 observers showed fair consistency, whilst 1 remaining observer showed poor consistency between repeated observations (p<0.01). The highest scores for interobserver agreement varying between moderate to good could only be established between 2 observers. For the remaining observers results were just fair (p<0.01). This study highlights the lack of agreement between senior clinicians when applying the modified LPC. This has clinical implications when applying the classification to the decision making process in treating patients at risk of developing adverse outcomes from the disease. To our knowledge, this is the first time the modified LPC has been independently tested for its reproducibility by another specialist paediatric orthopaedic unit


Bone & Joint Open
Vol. 5, Issue 6 | Pages 524 - 531
24 Jun 2024
Woldeyesus TA Gjertsen J Dalen I Meling T Behzadi M Harboe K Djuv A

Aims

To investigate if preoperative CT improves detection of unstable trochanteric hip fractures.

Methods

A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1).


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims

The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs.

Methods

The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%).


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1204 - 1206
1 Sep 2006
Malek IA Machani B Mevcha AM Hyder NH

Our aim was to assess the reproducibility and the reliability of the Weber classification system for fractures of the ankle based on anteroposterior and lateral radiographs. Five observers with varying clinical experience reviewed 50 sets of blinded radiographs. The same observers reviewed the same radiographs again after an interval of four weeks. Inter- and intra-observer agreement was assessed based on the proportion of agreement and the values of the kappa coefficient. For inter-observer agreement, the mean kappa value was 0.61 (0.59 to 0.63) and the proportion of agreement was 78% (76% to 79%) and for intra-observer agreement the mean kappa value was 0.74 (0.39 to 0.86) with an 85% (60% to 93%) observed agreement. These results show that the Weber classification of fractures of the ankle based on two radiological views has substantial inter-observer reliability and intra-observer reproducibility


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 72 - 76
1 Jan 2007
Patel V Day A Dinah F Kelly M Bircher M

Specific radiological features identified by Brandser and Marsh were selected for the analysis of acetabular fractures according to the classification of Letournel and Judet. The method employs a binary approach that requires the observer to allocate each radiological feature to one of two groups. The inter- and intra-observer variances were assessed. The presence of articular displacement, marginal impaction, incongruity, intra-articular fragments and osteochondral injuries to the femoral head were analysed by a similar method. These factors were termed ‘modifiers’ and are generally considered when planning operative intervention and, critically, they may influence prognosis. Six observers independently assessed 30 sets of plain radiographs and CT scans on two separate occasions, 12 weeks apart. They were asked to determine the presence or absence of specific radiological features. This simple binary approach to classification yields an inter- and intra-observer agreement which ranges from moderate to near-perfect (κ = 0.49 to 0.88 and κ = 0.57 to 0.88, respectively). A similar approach to the modifiers yields only slight to fair inter-observer agreement (κ = 0.20 to 0.34) and slight to moderate intra-observer agreement (κ = 0 to 0.55)


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 9 - 9
1 Feb 2014
Halai M Gupta S Gilmour A Bharadwaj R Khan A Holt G
Full Access

Leg length discrepancy (LLD) can adversely affect functional outcome and patient satisfaction after total hip arthroplasty. We describe a novel intraoperative technique for femoral component insertion. We aimed to determine if this technique resulted in the desired femoral placement, as templated, and if this was associated with a reduced LLD. A series of fifty consecutive primary total hip replacements were studied. Preoperative digital templating was performed on standardised PA radiographs of the hips by the senior surgeon. The preoperative LLD was calculated and the distance from the superior tip of the greater trochanter to the predicted shoulder of the stem was calculated (GT-S). Intraoperatively, this length was marked on the rasp handle and the stem inserted to the predetermined level by the surgeon. This level corresponded to the tip of the greater trochanter and formed a continuous line to the mark on the rasp handle. Three independent blinded observers measured the GT-S on the postoperative radiographs. We assessed the relationship between the senior author's GT-S (preoperative) and the observers' GT-S (postoperative) using a Person correlation. The observers also measured the preoperative and postoperative LLD, and the inter-observer variability was calculated as the intra-class correlation coefficient. There was a strong correlation of preoperative and postoperative GT-S (R=0.87), suggesting that the stem was inserted as planned. The mean preoperative and postoperative LLD were −4.3 mm (−21.4–4) and −0.9 mm (−9.8–8.6), respectively (p<0.001). This technique consistently minimised LLD in this series. This technique is quick, non-invasive and does not require supplementary equipment


Bone & Joint Open
Vol. 3, Issue 12 | Pages 953 - 959
23 Dec 2022
Raval P See A Singh HP

Aims

Distal third clavicle (DTC) fractures are increasing in incidence. Due to their instability and nonunion risk, they prove difficult to treat. Several different operative options for DTC fixation are reported but current evidence suggests variability in operative fixation. Given the lack of consensus, our objective was to determine the current epidemiological trends in DTC as well as their management within the UK.

Methods

A multicentre retrospective cohort collaborative study was conducted. All patients over the age of 18 with an isolated DTC fracture in 2019 were included. Demographic variables were recorded: age; sex; side of injury; mechanism of injury; modified Neer classification grading; operative technique; fracture union; complications; and subsequent procedures. Baseline characteristics were described for demographic variables. Categorical variables were expressed as frequencies and percentages.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 400 - 400
1 Sep 2012
Odri G Fraquet N Isnard J Redon H Frioux R Gouin F
Full Access

Cam type femoroacetabular impingement (FAI) is due to an aspheric femoral head, which is best quantified by the alpha angle described on MRI and CT-scan. Radiographic measurement of the alpha angle is not well codified and studies from the literature cannot conclude on the best view to measure it. Most authors also describe a mixed type FAI which associates an aspheric femoral head with an excessive anterior acetabular coverage of the femoral head. Anterior center edge (ACE) angle has been described on the false profile view to measure anterior acetabular coverage in hip dysplasia and has never been evaluated in FAI. In this study, we developed a new lateral hip view which associates a lateral view of the femoral neck and a false profile view of the acétabulum, which we called profile view in impingement position (PVIP). Twenty six patients operated for FAI had CT-scan, the PVIP and the false profile view of one or two hips according to pain. A control group of 19 patients who did not suffer from the hip had the PVIP. Alpha angles were measured twice on 17 CT scan of FAI patients by two observers and compared with the alpha angles measured on the corresponding hip PVIP by a correlation analysis. Alpha angles were measured twice on 45 PVIP in FAI patient and on 19 PVIP in the control group by three observers. ACE angles were measured once on 15 PVIP and on 15 false profile views. Means were compared by two tail paired t-tests, intra- and inter-observer reliability were measured by intraclass correlation coefficient. Mean alpha angle on CT scan was 65.8° and 65.6° for observers 1 and 2 respectively (p>0.05). It was 63.6° and 64.3° on the PVIP (p>0.05). No significant difference was found between CT scan and radiographic measurements, and Pearson's correlation coefficients were good at 0.74 and 0.8. ICC was 0.86 for inter-rater reliability, and 0.91 for intra-rater reliability for CT-scan alpha angle measures. ICC for PVIP measures varied from 0.82 to 0.9 for intra-rater reliability and from 0.6 to 0.9 for inter-rater reliability. Mean alpha angle measured on PVIP in FAI patients was 63.3° and was 44.9° in control subjects and the difference was significant (p<0.001) for the three observers. None of the FAI patients and 88% of the control subjects had an alpha angle < 50°. Mean ACE angle was 26.8° on PVIP and 32.8° on the false profile view, the difference was significant (p=0.015), and the Pearson's correlation coefficient was moderate (r=0.58). The PVIP is a reliable radiographic view to measure the alpha angle. It allows a good quantification of the alpha angle comparable to CT-scan measurements and permits to differentiate patients from control subjects. PVIP is not a good view to quantify anterior edge angle probably because of acetabular retroversion due to the hip flexion needed in this view. Mean ACE angle measured on the false profile view in FAI patient was comparable to ACE angle in general population reported in the literature


Bone & Joint Open
Vol. 5, Issue 11 | Pages 962 - 970
4 Nov 2024
Suter C Mattila H Ibounig T Sumrein BO Launonen A Järvinen TLN Lähdeoja T Rämö L

Aims

Though most humeral shaft fractures heal nonoperatively, up to one-third may lead to nonunion with inferior outcomes. The Radiographic Union Score for HUmeral Fractures (RUSHU) was created to identify high-risk patients for nonunion. Our study evaluated the RUSHU’s prognostic performance at six and 12 weeks in discriminating nonunion within a significantly larger cohort than before.

Methods

Our study included 226 nonoperatively treated humeral shaft fractures. We evaluated the interobserver reliability and intraobserver reproducibility of RUSHU scoring using intraclass correlation coefficients (ICCs). Additionally, we determined the optimal cut-off thresholds for predicting nonunion using the receiver operating characteristic (ROC) method.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1285 - 1291
1 Oct 2019
MacKenzie SA Ng RT Snowden G Powell-Bowns MFR Duckworth AD Scott CEH

Aims. Currently, periprosthetic fractures are excluded from the American Society for Bone and Mineral Research (ASBMR) definition of atypical femoral fracture (AFFs). This study aims to report on a series of periprosthetic femoral fractures (PFFs) that otherwise meet the criteria for AFFs. Secondary aims were to identify predictors of periprosthetic atypical femoral fractures (PAFFs) and quantify the complications of treatment. Patients and Methods. This was a retrospective case control study of consecutive patients with periprosthetic femoral fractures between 2007 and 2017. Two observers identified 16 PAFF cases (mean age 73.9 years (44 to 88), 14 female patients) and 17 typical periprosthetic fractures in patients on bisphosphonate therapy as controls (mean age 80.7 years (60 to 86, 13 female patients). Univariate and multivariate analysis was performed to identify predictors of PAFF. Management and complications were recorded. Results. Interobserver agreement for the PAFF classification was excellent (kappa = 0.944; p < 0.001). On univariate analysis compared with controls, patients with PAFFs had higher mean body mass indices (28.6 kg/m. 2. (. sd. 8.9) vs 21.5 kg/m. 2. (. sd. 3.3); p = 0.009), longer durations of bisphosphonate therapy (median 5.5 years (IQR 3.2 to 10.6) vs 2.4 years (IQR 1.0 to 6.4); p = 0.04), and were less likely to be on alendronate (50% vs 94%; p = 0.02) with an indication of secondary osteoporosis (19% vs 0%; p = 0.049). Duration of bisphosphonate therapy was an independent predictor of PAFF on multivariate analysis (R. 2. = 0.733; p = 0.05). Following primary fracture management, complication rates were higher in PAFFs (9/16, 56%) than controls (5/17, 29%; p = 0.178) with a relative risk of any complication following PAFF of 1.71 (95% confidence interval (CI) 0.77 to 3.8) and of reoperation 2.56 (95% CI 1.3 to 5.2). Conclusion. AFFs do occur in association with prostheses. Longer duration of bisphosphonate therapy is an independent predictor of PAFF. Complication rates are higher following PAFFs compared with typical PFFs, particularly of reoperation and infection. Cite this article: Bone Joint J 2019;101-B:1285–1291


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 138 - 138
1 Sep 2012
Umar M Patil V Lewthwaite S
Full Access

Quality of cementation in the early postoperative period has been proven to be an indicator of long-term survival of the total hip arthroplasty. Cementation grading described by Barrack et al is widely used but has certain limitations. It is based upon second-generation cementation technique and has unacceptably high inter- and intra-observer variability due to its subjective evaluation method. We are introducing a new grading system of quality of femoral cementation. It is based upon the ratio of the length of radiological lucency to the total length of cement-bone interface on both antero-posterior and lateral views. Because of its objective nature, it is likely to show reproducible results. We recruited five observers of various grades of surgical experience (trainees to consultant). Each observer graded the quality of femoral cementation on immediate postop xrays twice (gap of atleast two weeks) of 30 primary hip arthroplasties, using Barrack's grading and a new cementation index measured by dividing the ength of Radiolucency along CBI by the total Length of CBI. Statistical analysis was performed by SPSS v17.0. Inter-observer and Intra-observer variability was determined by Intraclass Correlation Coefficient for a two way mixed model. New cementation index showed excellent agreement for both inter and intra-observer reliability with intraclass correlation coefficient of 0.79 and 0.82 respectively. On contrary, results of inter-observer reliability for Barrack's grading were poor with value of 0.20. intra-observer reliability was found to be fair with 0.55. As evident from this study, it is a more reliable way of assessing the quality of cementation, with excellent agreement in both inter and intra-observer categories