Aims. Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS). Methods. Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)). Results. There were eight subsequent surgical interventions. Two failures (5%) of the triflange acetabular components were both revised because of deep infection. There were seven (18%) patients with dislocation, and five (13%) of these were treated with a constraint liner. One patient had a debridement, antibiotics, and implant retention (DAIR) procedure. In 34 (92%) hips the custom-made triflange component was considered stable, with a healed pelvic discontinuity with no aseptic loosening at
Aims. BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems. Methods. A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery. Results. At three months, the mean total translation (TT) was 0.95 mm (95% confidence interval (CI) 0.68 to 1.22) in the P group and 0.57 mm (95% CI 0.31 to 0.83) in the PBM group (p = 0.047). From two to five years, the TT increased by a mean of 0.14 mm (95% CI 0.03 to 0.25) more in the P group than in the PBM group (p = 0.021). In osteopenic patients (n = 20), the mean TT after three months was 1.61 mm (95% CI 1.03 to 2.20) in the P group and 0.73 mm (95% CI 0.25 to 1.21) in the PBM group (p = 0.023). After 60 months, the mean TT in osteopenic patients was 1.87 mm (95% CI 1.24 to 2.50) in the P group and 0.82 mm (95% CI 0.30 to 1.33) in the PBM group (p = 0.011). Conclusion. There was less early and
Instability is a common indication for revision total hip arthroplasty (THA). However, even after the initial revision, some patients continue to have recurrent dislocations. This study investigates those at risk for recurrent dislocation after revision THA for instability at a single institution. Between 2009 and 2019, 163 patients underwent revision THA for instability at a single institution. Thirty-three of these patients required re-revision THA due to recurrent dislocation. Cox proportional hazard models with death as a competing event were used to analyze risk factors, including prosthesis sizing and alignment. Paired t-tests or Wilcoxon signed rank tests were used to assess patient outcomes (Veterans RAND 12 (VR-12) physical score, VR-12 mental score, Harris Hip Score, and hip disability and osteoarthritis outcome score for joint replacement). Duration of follow-up until either re-revision or final follow-up was a mean of 45.3 ± 38.2 months. The 1-year cumulative incidence for recurrent dislocation after revision was 8.7%, which increased to 19.6% at 5 years and 32.9% at 10 years postoperatively. In the multivariable analysis, high ASA score [HR 2.71], being underweight (BMI<18 kg/m. 2. ) [HR 36.26] or overweight/obese (BMI>25 kg/m. 2. ) [HR 4.31], use of specialized liners [HR 5.51–10.71], lumbopelvic stiffness [HR 6.29], and postoperative abductor weakness [HR 7.20] were significant risk factors for recurrent dislocation. Increasing the cup size decreased the dislocation risk [HR 0.89]. The dual mobility construct did not affect the risk for recurrent dislocation in univariate or multivariable analyses. VR-12 physical and HHS (pain and function) scores improved postoperatively at
Introduction. The role for hip arthroscopy (HS) in combination with periacetabular osteotomy (PAO) for the treatment of symptomatic acetabular dysplasia has not been clearly defined. In this study, we assessed
Introduction. In Europe a femoral neck retaining stem (Metha, Aesculap Inc, Tuttlingen, Germany) has been reported with excellent
Background. The impact of a patient's activity level following total hip arthroplasty (THA) remains controversial, with some concerned about increased polyethylene wear, aseptic loosening and revisions. The purpose of this study is to report on implant survivorship and outcomes of high activity patients compared to low activity patients after THA with current polyethylene. Methods. A retrospective review identified 2002 patients (2532 hip) that underwent a primary THA with vitamin E infused highly crosslinked polyethylene liner and 2-year minimum follow-up or revision. Patients were divided in two groups based on their University of California Los Angeles (UCLA) activity level: Low activity (LA) (UCLA ≤5) and high activity (HA) (UCLA ≥ 6). Outcomes included Harris Hip Score, UCLA activity score, complications and reoperations. Multivariate nominal regression analysis was performed to evaluate the significance of postoperative activity level on survivorship while controlling for age, gender, preoperative pain, HHS and body mass index (BMI). Results. Mean follow-up was 4.5 years (range, 0.3 to 9.9 years). The LA group had significantly more female patients, were older, higher BMI and lower HHS pre-operatively (all with p<0.001). HA group had significantly higher improvements in HHS (p<0.001) and UCLA activity score (p<0.001). Aseptic revisions were performed in 2.1% of the LA group and in 0.4% hips of the HA group (p<0.001). Multivariate regression analysis found that a higher postoperative activity level remained a significant factor for improved aseptic survivorship with an OR of 4.9 (95% CI, 1.1 to 21.2, p=0.03). The aseptic 5-year survivorship was 99.6% for the HA group and 98% for the LA group (p<0.001). Conclusions. Higher activity level after primary THA did not increase the risk for
Background. Recurrent instability and dislocation after total hip arthroplasty are difficult complications. In certain cases, a constrained acetabular device can address these issues. The purpose of this study is to report the
Posterior extraarticular ischiofemoral hip impingement can be caused by high femoral torsion and is typically located between the ischium and the lesser trochanter. We asked if patients undergoing derotational femoral osteotomies for posterior FAI have (1) decreased hip pain and improved function and evaluated (2) subsequent surgeries and complications?. Thirty-three hips undergoing derotational femoral osteotomies between 2005 and 2016 were evaluated retrospectively. Of them 15 hips underwent derotational femoral osteotomies and 18 hips underwent derotational femoral osteotomies combined with varisation (neck-shaft angle >139°). Indication for derotational osteotomies was a positive posterior impingement test in extension and external rotation, high femoral torsion (48° ± 9) on CT scans and limited external rotation. Offset improvement was performed to avoid intraarticular impingement in hips with a cam-type FAI. All patients were female and mean followup was 3 ± 2 (1 – 11) years. At latest followup the positive posterior and anterior impingement test decreased from preoperatively 100% to 5% (p< 0.001) and from preoperatively 85% to 30% (p< 0.001). The mean Merle d'Aubigné Postel score increased from 14 ± 1 (11 – 16) to 16 ± 1 (13 – 17) at latest followup (p< 0.001). At followup 32/33 hips had been preserved and one hip had been converted to a total hip arthroplasty (THA). In two hips (6%) revision osteosynthesis was performed for delayed healing of the femoral osteotomy. Derotational femoral osteotomies for the treatment of posterior extraarticular ischiofemoral impingement caused by high femoral torsion result in decreased hip pain and improved function at
Introduction. Modularity in femoral stem designs allow surgeons to independently control leg length, offset, and femoral version in revision or complex primary THA cases. Initial enthusiasm in these modular stems has been tempered by recognition of modular junction failures. This study evaluates mean 5-year clinical results and survival rates of a 3-part titanium alloy modular femoral implant with unique taper geometries and a metaphyseal plasma spray surface. The current results are presented after pre-market independent fatigue testing performed by Orthopaedic Laboratory (Greenwald) and previously published early clinical results in 2006. Low plasticity burnishing (LPB) was added in 2005 to further strengthen the neck metaphyseal modular junction. The modular stem component is a polished cylindrical splined clothespin design. Our hypothesis is that these unique modular junctions succeed in offering the advantages of modularity without failure at this
Acetabular components used to treat large defects are at greater risk of loosening. Porous tantalum acetabular components have reported the most promising early to
Introduction. Within the field of arthroplasty, the use of patient-reported outcome measures (PROMs) is becoming increasingly ubiquitous in an effort to employ more patient-centered methods of evaluating success. PROMs may be used to assess general health, joint-specific pain or function, or mental health. General and joint-specific questionnaires are most often used in arthroplasty research, but the relationship between arthroplasty and mental health is less well understood. Furthermore, longitudinal reports of PROM changes after arthroplasty are lacking in the literature. Our primary aim was to quantify the improvement in general, joint-specific, and mental health PROMs following total hip arthroplasty (THA) as well as the extent of any deterioration through the 7 years follow-up. Our secondary aim was to identify predictors of clinically significant PROM decline. Methods. A total of 864 patients from 17 centers across 8 countries were enrolled into a prospective study. Patients were treated with components from a single manufacturer, which have been shown to be well-functioning in other studies. Patients completed a battery of PROMs preoperatively, and at one, three, five, and seven years post-THA. Changes in PROMs between study visits were assessed via paired tests. Postoperative trends for each PROM were determined for each subject by the slope of the best-fit line of the four postoperative data points. Significant PROM deterioration was defined as one literature-defined minimum clinically important difference over 5-years. Binary logistic regressions were used to identify independent predictors of significant decline in the EuroQol (EQ-5D) visual analogue scale (VAS) for Health State, 36-Item Short Form Survey (SF-36) physical composite summary (PCS), and SF-36 mental composite summary (MCS). Results. A total of 417 completed all study visits (70% of currently eligible). All patients experienced significant improvements in all hip-specific and most general health PROMs 1-year post-THA (all p ≤ 0.002). In addition, a significant number of patients experienced a reduction in anxiety/depression following THA (p < 0.001). Hip specific PROMs remained excellent through 7-years, but most general and mental health PROs declined by the 7-year visit. A total of 133 patients (32%) experienced significant deterioration in the EQ-5D Health State. Age greater than 60 years (odds ratio (OR) = 1.9; p = 0.002) and obesity (OR = 1.7; p = 0.036) were independently predictive of EQ-5D Health State decline. A total of 58 patients (14%) experienced significant deterioration in the SF-36 PCS. Independent predictors of significant SF-36 PCS decline were lower preoperative SF-36 MCS (OR = 0.9; p = 0.002) and obesity (OR = 2.6; p = 0.009). A total of 229 patients (55%) experienced significant deterioration in the SF-36 MCS. Age greater than 60 years was predictive of significant SF-36 MCS decline (OR = 1.8; p = 0.017). Conclusion. For most patients, hip-specific PROMs will remain near the 1-year level through 7-years follow-up. Except for those with lower preoperative mental health or with obesity, gauging a patient's hip-related status at 1-year is sufficient to extrapolate their trajectory through
The effect of pelvic tilt (PT) and sagittal balance in hips with pincer-type femoroacetabular impingement (FAI) with acetabular retroversion (AR) is controversial. It is unclear if patients with AR have a rotational abnormality of the iliac wing. Therefore, we asked: are parameters for sagittal balance, and is rotation of the iliac wing, different in patients with AR compared to a control group?; and is there a correlation between iliac rotation and acetabular version? A retrospective, review board-approved, controlled study was performed including 120 hips in 86 consecutive patients with symptomatic FAI or hip dysplasia. Pelvic CT scans were reviewed to calculate parameters for sagittal balance (pelvic incidence (PI), PT, and sacral slope), anterior pelvic plane angle, pelvic inclination, and external rotation of the iliac wing and were compared to a control group (48 hips). The 120 hips were allocated to the following groups: AR (41 hips), hip dysplasia (47 hips) and cam FAI with normal acetabular morphology (32 hips). Subgroups of total AR (15 hips) and high acetabular anteversion (20 hips) were analyzed. Statistical analysis was performed using analysis of variance with Bonferroni correction.Aims
Methods
We determined the
We report the survival, radiological and functional outcomes of a single surgeon series of his first 144 consecutive Birmingham hip resurfacing procedures (130 patients) at a minimum of ten years. There were ten revisions during this time. Although no patients were lost to follow-up some did not complete the scoring assessment or undergo radiological assessment at ten years. The ten-year survival for male patients was 98.0% (95% confidence interval 95.2 to 100). The ten-year survival for the total cohort with aseptic revision as the endpoint was 95.5% (95% confidence interval 91.8 to 99.0) and including revisions for sepsis was 93.5% (95% confidence interval 89.2 to 97.6). The median modified Oxford hip score at ten years was 4.2% (interquartile range 0 to 19) and the median University of California, Los Angeles score was 7.0 (interquartile range 5.0 to 8.0). This study confirms the
The unparalleled events of the year 2020 continue to evolve and challenge the worldwide community on a daily basis. The COVID-19 pandemic has had a major impact on all aspects of our lives, and has caused major morbidity and mortality around the globe. The impact of COVID-19 on the practice of orthopedic surgery has been substantial with practice shutdowns, elective surgery restrictions, heightened utilization of telemedicine platforms and implementation of precautionary measures for in-person clinic visits. During this transition period the scholarly and educational pursuits of academic surgeons have been de-emphasized as the more immediate demands of clinical practice survivorship have been the priority. This unavoidable focus on clinical practice has heightened the importance of orthopedic subspecialty societies in maintaining an appropriate level of attention on research and educational activities. Under the outstanding presidential leadership of Robert Barrack, MD, The Hip Society adapted to the profound challenges of 2020, and maintained strong leadership in the realms of education and research. The recent 2020 summer meeting of the Hip Society was a testimonial to the resilience and dedication of the Society members to ongoing innovation in research and education. Due to travel and social distancing restrictions the 2020 summer meeting was transitioned from an in-person to a virtual meeting format. Dr Barrack and Program Chair Dr John Clohisy assisted with oversight of the meeting, while Olga Foley and Cynthia Garcia ensured the success of the meeting with remarkable planning and organization. These collaborative efforts resulted in an organized, well-attended, high level scientific meeting with engaging discussion and a remarkable virtual conference environment. The Bone & Joint Journal is very pleased to partner with The Hip Society to publish the proceedings of this very unique virtual meeting. The Hip Society is based in the United States and membership is granted to select individuals for leadership accomplishments in education and research related to hip disease. The Society is focused on the mission of advancing the knowledge and treatment of hip disorders to improve the lives of patients. The vision of the Hip Society is to lead in the discovery and dissemination of knowledge related to disorders of the hip. The annual closed meeting is one of the most important events of the society as this gathering highlights timely, controversial and novel research contributions from the membership. The top research papers from The Hip Society meeting will be published and made available to the wider orthopedic community in The Bone & Joint Journal. This partnership with The Bone & Joint Journal enhances the mission and vision of The Hip Society by international dissemination of the meeting proceedings. Given the far-reaching circulation of The Bone & Joint Journal the highest quality work is available to an expanding body of surgeons, associated healthcare providers and patients. Ultimately, this facilitates the overarching Hip Society goal of improving the lives of our patients. The 2020 virtual Hip Society meeting was characterized by outstanding member attendance, high quality paper presentations and robust discussion sessions. The meeting was held over two days and encompassed 58 open paper presentations divided into ten sessions with moderated discussions after each session. All papers will be presented in this issue in abstract form, while selected full papers passing our rigorous peer review process will be available online and in The Bone & Joint Journal in a dedicated supplement in 2021. The first session of the meeting focused on issues related to complex primary THA and osteonecrosis of the femoral head. Dr Gross presented on the conversion of hip fusion to THA in 28 patents at a mean 7 years. He reported a high clinical success rate, yet complications of heterotopic ossification and neurologic injury were relatively common. Consideration of heterotopic ossification prophylaxis and the selective use of a constrained liner were recommended. Dr Pagnano summarized the use of various contemporary porous acetabular components in 38 hips in the setting of prior pelvic radiation. The mean follow-up was 5 years and 10 year survivorship was 100% with all implants radiographically fixed. Dr Bolognesi's study demonstrated that THA in solid organ transplant patients is associated with higher risk for facility placement, transfusions and readmissions. This patient population also has increased mortality risk (4.3% risk at 1 year) especially lung transplant patients. The second group of papers focused on femoral head osteonecrosis. Dr Iorio presented single center data demonstrating that CT scan was a useful adjunct for diagnosis in the staging work-up for cancer, yet was not useful for ARCO staging and treatment decision-making. On the basic science side, Dr Goodman utilized a rabbit model of steroid-induced femoral head osteonecrosis to determine that immunomodulation with IL-4 has the potential to improve bone healing after core decompression. The session was concluded by Dr Nelson's study of ceramic-on-ceramic THA in 108 osteonecrosis patients. The median 12 year results were outstanding with marked increases in PROs, maintenance of high activity levels, and a 3.7% revision rate. In the second session attention was directed to THA instability and spinopelvic mobility. Dr Sierra presented a machine learning algorithm for THA dislocation risk. Two modifiable variables (anterior/lateral approach, elevated liner) were most influential in minimizing dislocation risk. Dr Taunton's study demonstrated a deep learning artificial intelligence model derived from postoperative radiographs to predict THA dislocation risk. High sensitivity and negative predictive value suggest that this model may be helpful in assessing postoperative dislocation risk. In reviewing a large single-center, multiple surgeon cohort of 2,831 DAA procedures, Dr Moskal noted a very low dislocation rate (0.45%) at minimum 2 years. Importantly, spinopelvic pathology or prior spinal instrumentation was not associated with an increased dislocation risk (0.30%). Dr Huo and colleagues analyzed pelvic tilt during functional gait in patients with acetabular dysplasia. They detected variable pelvic tilt on different surfaces with the data suggesting that patients with more anterior pelvic tilt while standing tend to have greater compensatory posterior pelvic tilt during gait. Dr Lamontagne reported on the sagittal and axial spinomobility in patients with hip OA, and highlighted reductions in pelvic tilt, pelvic-femoral-angle, lumbar lordosis and seated maximal trunk rotation when compared to controls. Dr Dennis showed that differences in spinopelvic mobility may explain the variable accuracy of acetabular version measurements on the cross-table lateral radiographs. Dr Gwo-Chin presented on a comprehensive functional analysis of 1,592 patients undergoing THA and observed that spinopelvic abnormalities are not infrequent (14%) in THA patients. Consistent with these findings Dr Murphy and collaborators identified a low prevalence of previous spinal instrumentation (1.5%), yet a high prevalence of spine stiffness (27.6%) in 149 patients undergoing THA. Session three highlighted various aspects of treating hip disease in young patients. Dr Peters investigated the need for subsequent hip arthroscopy in 272 patients treated with an isolated PAO. Only 4.8% of these patients required subsequent arthroscopy calling into question the routine use of combined arthroscopy and PAO. Three papers addressed questions related to THA in young patients. Dr Berend's study of 2532 hips demonstrated that high activity level was not associated with an increased risk of
We used a trochanteric slide osteotomy (TSO) in 94 consecutive revision total hip arthroplasties (90 with replacement of both the cup and stem). This technique proved to be adequate for removing the components, with few complications (two minor fractures), and for implanting acetabular allografts (18%) and reinforcement devices (23%). Trochanteric union was obtained in most patients (96%), even in those with septic loosening (18/19), major femoral osteolysis (32/32), or previous trochanteric osteotomy (17/18). TSO is versatile, since it can be extended by a femoral flap (four cases) or a distal femoral window (eight cases). Despite significant bone loss, in 24% of the femora and 57% of the acetabula, favourable
The aim of this study was to compare patient-reported outcome measures (PROMs), radiological measurements, and total hip arthroplasty (THA)-free survival in patients who underwent periacetabular osteotomy (PAO) for mild, moderate, or severe developmental dysplasia of the hip. We performed a retrospective study involving 336 patients (420 hips) who underwent PAO by a single surgeon at an academic centre. After exclusions, 124 patients (149 hips) were included. The preoperative lateral centre-edge angle (LCEA) was used to classify the severity of dysplasia: 18° to 25° was considered mild (n = 20), 10° to 17° moderate (n = 66), and < 10° severe (n = 63). There was no difference in patient characteristics between the groups (all, p > 0.05). Pre- and postoperative radiological measurements were made. The National Institute of Health’s Patient Reported Outcomes Measurement Information System (PROMIS) outcome measures (physical function computerized adaptive test (PF CAT), Global Physical and Mental Health Scores) were collected. Failure was defined as conversion to THA or PF CAT scores < 40, and was assessed with Kaplan–Meier analysis. The mean follow-up was five years (2 to 10) ending in either failure or the latest contact with the patient.Aims
Patients and Methods
In previous studies, we identified multiple factors influencing the survivorship of hip resurfacing arthroplasties (HRAs), such as initial anatomical conditions and surgical technique. In addition, the University of California, Los Angeles (UCLA) activity score presents a ceiling effect, so a better quantification of activity is important to determine which activities may be advisable or detrimental to the recovered patient. We aimed to determine the effect of specific groups of sporting activities on the survivorship free of aseptic failure of a large series of HRA. A total of 661 patients (806 hips) representing 77% of a consecutive series of patients treated with metal-on-metal hybrid HRA answered a survey to determine the types and amounts of sporting activities they regularly participated in. There were 462 male patients (70%) and 199 female patients (30%). Their mean age at the time of surgery was 51.9 years (14 to 78). Their mean body mass index (BMI) was 26.5 kg/m2 (16.7 to 46.5). Activities were regrouped into 17 categories based on general analogies between these activities. Scores for typical frequency and duration of the sessions were used to quantify the patients’ overall time spent engaging in sporting activities. Impact and cycle scores were computed. Multivariable models were used.Aims
Patients and Methods
Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results. We enrolled 42 patients (21 male, 21 female) with osteoarthritis and a mean age of 67 years (Aims
Patients and Methods
Surface replacement arthroplasty (SRA), compared with traditional total hip arthroplasty (THA), is more expensive and carries unique concern related to metal ions production and hypersensitivity. Additionally, SRA is a more demanding procedure with a decreased margin for error compared with THA. To justify its use, SRA must demonstrate comparable component survival and some clinical advantages. We therefore performed a systematic literature review to investigate the differences in complication rates, patient-reported outcomes, stress shielding, and hip biomechanics between SRA and THA. A systematic review of the literature was completed using MEDLINE and EMBASE search engines. Inclusion criteria were level I to level III articles that reported clinical outcomes following primary SRA compared with THA. An initial search yielded 2503 potential articles for inclusion. Exclusion criteria included review articles, level IV or level V evidence, less than one year’s follow-up, and previously reported data. In total, 27 articles with 4182 patients were available to analyze.Aims
Materials and Methods