Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 89 - 89
23 Feb 2023
Marasco S Gieroba T Di Bella C Babazadeh S Van Bavel D
Full Access

Identifying and restoring alignment is a primary aim of total knee arthroplasty (TKA). In the coronal plane, the pre-pathological hip knee angle can be predicted using an arithmetic method (aHKA) by measuring the medial proximal tibial angle (MPTA) and lateral distal femoral angle (aHKA=MPTA - LDFA). The aHKA is shown to be predictive of coronal alignment prior to the onset of osteoarthritis; a useful guide when considering a non-mechanically aligned TKA. The aim of this study is to investigate the intra- and inter-observer accuracy of aHKA measurements on long leg standing radiographs (LLR) and preoperative Mako CT planning scans (CTs). Sixty-eight patients who underwent TKA from 2020–2021 with pre-operative LLR and CTs were included. Three observers (Surgeon, Fellow, Registrar) measured the LDFA and MPTA on LLR and CT independently on three separate occasions, to determine aHKA. Statistical analysis was undertaken with Bland-Altman test and coefficient of repeatability. An average intra-observer measurement error of 3.5° on LLR and 1.73° on CTs for MPTA was detected. Inter-observer errors were 2.74° on LLR and 1.28° on CTs. For LDFA, average intra-observer measurement error was 2.93° on LLR and 2.3° on CTs, with inter-observer errors of 2.31° on LLR and 1.92° on CTs. Average aHKA intra-observer error was 4.8° on LLR and 2.82° on CTs. Inter-observer error of 3.56° for LLR and 2.0° on CTs was measured. The aHKA is reproducible on both LLR and CT. CT measurements are more reproducible both between and within observers. The difference between measurements using LLR and CT is small and hence these two can be considered interchangeable. CT may obviate the need for LLRs and may overcome difficulties associated with positioning, rotation, body habitus and flexion contractures when assessing coronal alignment


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 71 - 71
23 Feb 2023
Gupta S Wakelin E Putman S Plaskos C
Full Access

The Coronal Plane Alignment of the Knee (CPAK) is a recent method for classifying knees using the hip-knee-ankle angle and joint line obliquity to assist surgeons in selection of an optimal alignment philosophy in total knee arthroplasty (TKA)1. It is unclear, however, how CPAK classification impacts pre-operative joint balance. Our objective was to characterise joint balance differences between CPAK categories. A retrospective review of TKA's using the OMNIBotics platform and BalanceBot (Corin, UK) using a tibia first workflow was performed. Lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) were landmarked intra-operatively and corrected for wear. Joint gaps were measured under a load of 70–90N after the tibial resection. Resection thicknesses were validated to recreate the pre-tibial resection joint balance. Knees were subdivided into 9 categories as described by MacDessi et al.1 Differences in balance at 10°, 40° and 90° were determined using a one-way 2-tailed ANOVA test with a critical p-value of 0.05. 1124 knees satisfied inclusion criteria. The highest proportion of knees (60.7%) are CPAK I with a varus aHKA and Distal Apex JLO, 79.8% report a Distal Apex JLO and 69.3% report a varus aHKA. Greater medial gaps are observed in varus (I, IV, VII) compared to neutral (II, V, VIII) and valgus knees (III, VI, IX) (p<0.05 in all cases) as well as in the Distal Apex (I, II, III) compared to Neutral groups (IV, V, VI) (p<0.05 in all cases). Comparisons could not be made with the Proximal Apex groups due to low frequency (≤2.5%). Significant differences in joint balance were observed between and within CPAK groups. Although both hip-knee-ankle angle and joint line orientation are associated with joint balance, boney anatomy alone is not sufficient to fully characterize the knee


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 46 - 46
1 May 2021
Pickles E Sourroullas P Palanivel A Muir R Moulder E Sharma H
Full Access

Introduction. Deformity influences the weight bearing stresses on the knee joint. Correction of mechanical alignment is performed to offload the knee and slow the rate of degenerative change. Fixator assisted deformity correction facilitates accurate correction prior to internal fixation. We present our results with standard Ilizarov and UNYCO system assisted deformity correction of the lower limb. Materials and Methods. Retrospective analysis of adult surgical cases of mechanical re-alignment performed between 2010 and 2019 in a tertiary referral centre. We recorded standard demographics and operative time from the electronic patient record. We analysed digitalised radiographs to record pre- and post-operative measurements of: Mechanical axis deviation (MAD), femoral tibial angle (FTA), Medial Proximal tibial angle (MPTA) and Mechanical lateral distal femoral angle (mLDFA). The accuracy of the correction was analysed. Time to healing, secondary interventions and complications were also recorded. Results. 7 patients underwent fixator assisted deformity correction with the UNYCO system and 11 with a standard Ilizarov frame. Mean pre-op MAD was 45.8mm in the UNYCO group and 43.4mm in Ilazrov; Mean post-op MAD was 9.5mm in the UNYCO group (5–15) and 12.3 in the Ilizarov group (1–25) p=0.07. The average surgical time in the UNYCO group was 200 minutes (128–325) and 252 minutes (203–301) in the Ilizarov group p=0.07. The mean post op MPTA was 90.2 (87–96) in the UNYCO group and 87.4 (81–94) in the Ilizarov group. The mean mLDFA was 90.0(81–93.5) in the UNYCO group and 87.3(82.2–93.9) in the Ilizarov group. All the corrections involved a plate or nail fixation and mean time to union was 76.3 days in the UNYCO and 117.3 in the Ilizarov group. Conclusions. Both systems allowed accurate correction of deformity and limb alignment. In this small series we were unable to show a difference in theatre time. The application of the principles of deformity correction are as important as the surgical methods


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 83 - 83
1 Apr 2019
Mullaji A Shetty G
Full Access

Aims. The aims of this retrospective study were to determine the incidence of extra-articular deformities (EADs), and determine their effect on postoperative alignment in knees undergoing mobile-bearing, medial unicompartmental knee arthroplasty (UKA). Patients and Methods. Limb mechanical alignment (hip-knee-ankle angle), coronal bowing of the femoral shaft and proximal tibia vara or medial proximal tibial angle (MPTA) were measured on standing, full-length hip-to-ankle radiographs of 162 patients who underwent 200 mobile-bearing, medial UKAs. Results. Incidence of EAD was 7.5% for coronal femoral bowing of >5°, 67% for proximal tibia vara of >3° (MPTA<87°) and 24.5% for proximal tibia vara of >6° (MPTA<84°). Mean postoperative HKA angle achieved in knees with femoral bowing ≤5° was significantly greater when compared to knees with femoral bowing >5° (p=0.04); in knees with proximal tibia vara ≤3° was significantly greater when compared to knees with proximal tibia vara >3° (p=0.0001) and when compared to knees with proximal tibia vara >6° (p=0.0001). Conclusion. Extra-articular deformities are frequently seen in patients undergoing mobile-bearing medial UKAs, especially in knees with varus deformity>10°. Presence of an EAD significantly affects postoperative mechanical limb alignment achieved when compared to limbs without EAD and may increase the risk of limbs being placed in varus>3° postoperatively. Clinical Relevance. Since the presence of an EAD, especially in knees with varus deformity>10°, may increase the risk of limbs being placed in varus>3° postoperatively and may affect long-term clinical and implant survival outcomes, UKR in such knees should be performed with caution


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 65 - 65
1 Feb 2020
Yamamuro Y Kabata T Kajino Y Inoue D Ohmori T Ueno T Yoshitani J Ueoka K Tsuchiya H
Full Access

Objective. Open-wedge high tibial osteotomy (OWHTO) involves performing a corrective osteotomy of the proximal tibia and removing a wedge of bone to correct varus alignment. Although previous studies have investigated changes in leg length before and after OWHTO using X-rays, none has evaluated three-dimensional (3D) leg length changes after OWHTO. We therefore used 3D preoperative planning software to evaluate changes in leg length after OWHTO in three dimensions. Methods. The study subjects were 55 knees of 46 patients (10 men and 36 women of mean age 69.9 years) with medial osteoarthritis of the knee or osteonecrosis of the medial femoral condyle with a femorotibial angle of >185º and restricted range of motion (extension <–10º, flexion <130º), excluding those also suffering from patellofemoral arthritis or lateral osteoarthritis of the knee. OWHTO was simulated from computed tomography scans of the whole leg using ZedHTO 3D preoperative planning software. We analyzed the hip-knee-ankle angle (HKA), flexion contracture angle (FCA), mechanical medial proximal tibial angle (mMPTA), angle of correction, wedge length, 3D tibial length, 3D leg length, and 3D increase in leg length before and after OWHTO. We also performed univariate and multivariate analysis of factors affecting the change in leg length (preoperative and postoperative H-K-A angle, wedge length, and correction angle). Results. Mean HKA increased significantly from −4.7º ± 2.7º to 3.5º ± 1.3º, as did mean mMPTA from 83.7º ± 3.3º to 92.5º ± 3.0º (p <0.01). Mean FCA was 4.7º ± 3.6° preoperatively and 4.8º ± 3.3º postoperatively, a difference that was not significant (p = 0.725). The mean correction angle was 9.1º ± 2.8º and the mean wedge length was 9.4º ± 3.2º mm. Mean tibial length increased significantly by 4.7 ± 2.3 mm (p <0.01), and mean leg length by 5.6 ± 2.8 mm (p <0.01). The change in leg length was strongly correlated with wedge length (R = 0.846, adjusted R. 2. = 0.711, p <0.01). Discussion and Conclusion. Mean 3D leg length after OWHTO increased significantly by 5.4 ± 3.1 mm. A difference in leg length of >5 mm is believed to affect back pain and gait abnormalities, and changes in leg length must therefore be taken into consideration. The 3D dimensional change in leg length was strongly correlated with wedge length, and could be predicted by the formula (change in leg length in mm) = [(wedge length in mm) ×0.75) − 1.5]. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 14 - 14
1 May 2016
Manalo J Patel A Goyal N Fitz D Talati R Stulberg S
Full Access

Introduction. Three anatomic landmarks are typically used to estimate proper femoral component rotation in total knee arthroplasty: the transepicondylar axis (TEA), Whiteside's line, and the posterior condylar axis (PCA). Previous studies have shown that the presence of tibia vara may be accompanied by a hyperplastic posteromedial femoral condyle, which affects the relationship between the PCA and the TEA. The purpose of this study was to determine the relationship of tibia vara with the PCA. Methods. Two hundred and forty-eight knees underwent planning for total knee arthroplasty with MRI. The MRI was used to characterize the relationship between the transepicondylar axis and the posterior condylar axis. Long-leg standing films (LLSF) were obtained to evaluate the medial proximal tibial angle. The MPTA is defined as the medial angle formed between a line along the anatomic axis of the tibia and a line along the tibial plateau. Results. There were 168 knees in varus and 80 in valgus. The PCA in the patient group was 2.38 degrees ± 1.6 degrees. Regression analysis of tibial varus compared to the PCA showed a small association where for each degree of tibial varus, there was an additional 0.07 degrees of internal rotation of the PCA (p = 0.01). When defining tibia vara as a MPTA <84 degrees, there was no difference between patients with and without tibia vara (p=0.0661) although there was a trend toward a smaller PCA with increased tibia vara. When defining tibia vara as a MPTA <82 degrees there was again no difference in PCA between patients with and without tibia vara (p=0.825). Conclusion. Tibia vara did not influence the PCA to a clinically significant degree. This result is in contrast to previous studies which indicated that increased tibial varus correlated to increased internal rotation of the PCA with respect to the TEA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 37 - 37
1 Dec 2016
Leveille L Razi O Johnston C
Full Access

With observed success and increased popularity of growth modulation techniques, there has been a trend towards use in progressively younger patients. Younger age at growth modulation increases the likelihood of complete deformity correction and need for implant removal prior to skeletal maturity introducing the risk of rebound deformity. The purpose of this study was to quantify magnitude and identify risk factors for rebound deformity after growth modulation. We performed a retrospective review of all patients undergoing growth modulation with a tension band plate for coronal plane deformity about the knee with subsequent implant removal. Exclusion criteria included completion epiphysiodesis or osteotomy at implant removal, ongoing growth modulation, and less than one year radiographic follow-up without rebound deformity. Mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), hip-knee-ankle angle (HKA), and mechanical axis station were measured prior to growth modulation, prior to implant removal, and at final follow-up. Sixty-seven limbs in 45 patients met the inclusion criteria. Mean age at growth modulation was 9.8 years (range 3.4–15.4 years) and mean age at implant removal was 11.4 years (range 5.3–16.4 years). Mean change in HKA after implant removal was 6.9O (range 0O–23 O). Fifty-two percent of patients had greater than 5O rebound and 30% had greater than 10O rebound in HKA after implant removal. Females less than ten years and males less than 12 years at time of growth modulation had greater mean change in HKA after implant removal compared to older patients (8.4O vs 4.7O, p=0.012). Patients with initial deformity greater than 20O degrees had an increased frequency of rebound greater than 10O compared to patients with less severe initial deformity (78% vs 22%, p=0.002). Rebound deformity after growth modulation is common. Growth modulation at a young age and large initial deformity increases risk of rebound. However, rebound does not occur in all at risk patients, therefore, we caution against routine overcorrection. Patients and their families should be informed about the risk of rebound deformity after growth modulation and the potential for multiple surgical interventions prior to skeletal maturity


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 71 - 71
1 May 2013
Dunbar M
Full Access

Conventional total knee arthroplasty aims to place the joint line perpendicular to the mechanical axis, despite the fact that the normal knee is inclined approximately 3 degrees, resulting in a medial proximal tibial angle of 87 degrees. The goal of a neutral mechanical axis is based largely on historical biomedical studies and the fact that it is easier to make a neutral tibial cut with conventional jigs and the eye. In order to balance the flexion and extension gap to accommodate a neutral tibial cut, in most patients, asymmetrical distal and posterior femoral cuts are required. The resulting position of the femoral component could be considered to be “mal-rotated” with respect to the patient's soft tissue envelope. Soft tissue releases are often required. The target of neutral mechanical axis, or “straight and narrow,” represents a compromise position with respect to the kinematics of the knee. Neutral mechanical alignment may not confer any befits with respect to survivorship but dissatisfaction rates are high globally, with approximately 20% of patients being dissatisfied after total knee arthroplasty in multiple studies. Computer assisted surgery and shape matching allow for consideration of placing total knee components to match an individual's anatomy, as opposed to forcing the knee into an unnatural neutral mechanical alignment


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 31 - 31
1 Aug 2013
Firth G Kontio K Mosquijo J
Full Access

Purpose:. Despite advances in limb reconstruction, there are still a number of young patients who require trans-tibial amputation. Amputation osteoplasty is a technique described by Ertl to enhance rehabilitation after trans-tibial amputation. The purpose of the present study was to evaluate the results of the original Ertl procedure in skeletally immature patients, and to assess whether use of this procedure would result in a diminished incidence of bony overgrowth. Methods:. Four consecutive patients (five amputations) treated between January 2005 and June 2008 were reviewed. Clinical evaluation consisted of completion of the prosthesis evaluation questionnaire (PEQ) and physical examination. Radiographic analysis was performed to evaluate bone-bridge healing, bone overgrowth and the medial proximal tibial angle (MPTA). Results:. The best mean PEQ result in the Question section was 91.8 (Range 74–100) for ‘Well being’ and the worst mean score was 66.6 (Range 50–78) for the sub-section ‘Residual limb health’. Examination of the residual limbs revealed no bursae were present and all knees were stable with full range of movement. All bony bridges united at an average age of 1.7 months (Range 1–2). One case required stump revision for bony overgrowth, and one case developed asymptomatic mild genu varum. Conclusions:. In this series, the original Ertl osteomyoplasty shows good functional and prosthetic use with only one bony overgrowth requiring revision surgery


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 149 - 149
1 May 2016
Lee B Wang J Kim G
Full Access

Introduction. Medial open wedge high tibial osteotomy (HTO) is a generally accepted surgical method for medial unicompartmental osteoarthritis with varus malalignment of the lower extremity. However, several authors have suggested the possibility of unintentional secondary changes during open wedge HTO, which include posterior tibial slope angle (PTS) change, tibial rotation change and medial–lateral slope change of the knee joint line, may influence knee kinematics and produce poor clinical outcomes. We sought to analyze postoperative changes in three-dimensional planes using a virtual wedge osteotomy 3D model. Pre- and post-operative changes in the medial proximal tibial angle (MPTA) in the coronal plane, posterior tibial slope (PTS) in the sagittal plane, and axial tibial rotation were measured as dependent variables. And this study was attempted to determine their mutual relationships and to clarify which independent variables, including hinge axis angle and gap ratio, affect tibial rotation change and PTS change by applying the identified hinge position. Method. A total of 17 patients with 19 knees underwent HTO and were evaluated with 3D-CT before and after surgery. A 3D model was constructed by applying reverse engineering software. Results. No significant linear correlation was observed between the three dependent variables: MPTA, PTS, and rotational change. Gap ratio (β = −0.2830, p = 0.0007) and hinge axis angle (β = 0.7395, p = 0.0005) were significant factors in determining rotation change with moderate correlation (R2 = 0.546 and 0.520, respectively). In univariate regression analysis, gap ratio (p = 0.6284) and hinge axis angle (p = 0.0968) were not significant factors determining the PTS; however, after controlling for confounder, rotation change, they became statistically significant (hinge axis: β = 0.44, p = 0.0059; gap ratio: β = 0.14, p = 0.0174). Discussion and Conclusion. Unchanged axial rotation is a requisite for constant unchanged PTS, and hinge axis angle have to be considered as an important independent variable for limitation of unintended secondary changes. This study might provide clues about the low reliability of intact slope angle, That is, representability of gap ratio as slope change can be interfered by rotational change, as a confounder. Also, the current study reported the external rotation tendency of proximal tibia with increasing hinge axis angle


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 93 - 93
1 Mar 2017
Pourzal R Cip J Rad E Laurent M Jacobs J Wimmer M
Full Access

Introduction. Wear debris from polyethylene tibial inserts has been associated with limited longevity of total knee replacements (TKRs). While material factors were studied extensively and considerable progress has been made, there is little knowledge about surgical factors, particularly on how the wear rate is related to implant positioning. It was the purpose of this study to determine the combined effect of patient and implant positioning factors on the volumetric wear rate of TKRs. Our hypothesis was that implant alignment has a significant impact on the wear rate when controlled for other patient factors. Methods. This study included 59 tibial inserts of a cruciate retaining TKR design (Nexgen, Zimmer Inc.). The patients' age, sex, weight, height, and implant size were obtained. All implants were scanned with a coordinate measuring machine. Volumetric wear was determined using an autonomous mathematical reconstruction method (Figure 1). Radiographs were used to determine the anatomic lateral distal femoral angle (aLDFA), anatomic medial proximal tibial angle (aMPTA), femoral tilt angle (FTA) and posterior tibial slope (PTS). Also, the patella position was assessed using the Blackburne-Peel Index (BPI) and the Insall-Salvati Ratio (Figure 2). General linear modeling (SPSS) was conducted in order to determine the most significant patient and implant positioning factors on wear rate. Results. After adjustment for creep, the mean volumetric wear rate was 11.6 mm. 3. /yr (Figure 2). According to the linear regression model wear increased with younger age (p=0.0014) and male sex (p<0.001). The wear rate was independent of patient weight (p=0.17). From the multiple positioning factors only BPI and tibial slope were significant and inversely correlated with wear (p=0.009 and 0.026, respectively). The average ISR was normal before and after surgery, whereas the BPI was only in the normal range prior to surgery, and dropped postop into pseudo-baja (p<0.001, Figure 3). Discussion. The effect of male sex on wear volume can partially be explained by a larger average implant size; however, other unknown confounding factors may play a role too. The effect of younger age is likely related to higher patient activity. Based on previous gait analysis, we speculate that increasing tibial slope results in larger AP translations of the knee joint and thus more wear. Interestingly, BPI remained a highly significant factor when controlled for all other factors. The average BPI clearly dropped post-operatively, whereas the average ISR did not, indicating that not true patella baja, but a joint line elevation occurred due to the reconstruction. Joint line elevation may affect the quadriceps mechanism leading to higher contact forces and subsequent higher wear. Post-operative joint line elevation can be explained by the intention to keep bone loss at a minimum, while using thick polyethylene inserts. Further studies are needed to determine the trade-offs between bone conservation and reduction of wear rate. However, this study has revealed the importance of surgical factors regarding polyethylene wear reduction in TKR. Acknowledgements. This study was funded by NIH grant R01AR059843. For figures/tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 32 - 32
1 May 2016
Carroll K Barlow B Mclawhorn A Esposito C Mayman D
Full Access

Introduction. Neutral mechanical alignment in TKA has been shown to be an important consideration for survivorship, wear, and aseptic loosening. However, native knee anatomy is described by a joint line in 3° of varus, 2–3° of mechanical distal femoral valgus, and 2–3° of proximal tibia varus. Described kinematic planning methods replicate native joint alignment in extension without changing tibiofemoral alignment, but do not account for native alignment through a range of motion. An asymmetric TKA femoral component with a thicker medial femoral condyle and posterior condylar internal rotation paired with an asymmetric polyethylene insert aligns the joint line in 3° of varus while maintaining distal femoral and proximal tibial cuts perpendicular to mechanical axis. The asymmetric components recreate an anatomic varus joint line while avoiding tibiofemoral malalignment or femoral component internal rotation, a risk factor for patellofemoral maltracking. The study seeks to determine how many patients would be candidates for a kinematically planned knee without violating the principle of a neutral mechanical axis (0° ± 3°). Methods. A cohort comprised of 55 consecutive preoperative THA patients with asymptomatic knees and 55 consecutive preoperative primary unilateral TKA patients underwent simultaneous biplanar radiographic imaging. Full length coronal images from the thoracolumbar junction to the ankles were measured by two independent observers for the following: mechanical tibiofemoral angle (mTFA), mechanical lateral distal femoral angle (mLDFA), and mechanical medial proximal tibial angle (mMPTA). Patients who met the following conditions: mTFA 0°±3°; mLDFA 87°±3°; and mMPTA 87°±3°, were considered candidates for TKA with an asymmetric implant that would achieve a kinematic joint line and neutral mechanical axis. Similarly, patients with the following conditions: mTFA 0°±3°; mLDFA 90°±3°; and mMPTA 90°±3°, were considered candidates for TKA with a symmetric implant that would achieve a kinematic joint line and neutral mechanical axis. Results. In this cohort of 110 patients, the mean mTFA was 1° varus ± 5°, the mean mLDFA was 87° ± 3°, mMPTA 87°± 2°. The comparison of patients meeting each of the three conditions required for a TKA with a neutral mechanical axis and a kinematic joint line are outlined in Table 1. Conclusion. A TKA with kinematic 3° varus joint line and neutral mechanical axis was possible in 52% of patients using an asymmetric implant and 23% of patients using a symmetric implant. Previous descriptions of kinematic planning using standard TKA components required compromise of neutral mechanical axis alignment with detrimental effects on overall survivorship. Knee arthroplasty using an asymmetric implant may achieve the best of both worlds, neutral mechanical axis and a kinematic joint line, in a large percentage of patients


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 368 - 368
1 Dec 2013
Kazemi SM Mehrabani MB Qoreishi SM Safdari F
Full Access

Background:. It has been suggested that double-level osteotomy can prevent the occurrence of joint line obliquity (JLO), as one of the complications following high tibial osteotomy (HTO). In this study, we aimed to compare the preoperative distal femoral and proximal tibial obliquity in patients with primary genu varum with a group of normal subjects (without genu varum). Materials and methods:. 75 patients with primary genu varum and 75 normal persons, contributed to a case-control study. The medial distal femoral mechanical angle (MDFMA), medial proximal tibial mechanical angle (MPTMA), joint diversion angle (JDA) and femoral and tibial JLO were measured and compared between the two groups. The percentage of patients' with > 4 degrees of JLO in both distal of femur and proximal of tibia, were then determined. Results:. The mean of MDFMA and MPTMA were significantly lower and JDA and femoral and tibial JLO were significantly higherin genu varum group (p < 0.05). Double-level osteotomy was required in 25.3% of patients with genu varum to prevent post-operative JLO. Conclusion:. JLO is a common finding in patients with genu varum and normal group; however, it is significantly higher in patients with genu varum


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 146 - 152
1 Jan 2010
Bilen FE Kocaoglu M Eralp L Balci HI

We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed.

The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60).

One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation.

We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone.