Advertisement for orthosearch.org.uk
Results 1 - 20 of 156
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 479 - 483
1 Apr 2011
Chang C Lai K Yang C Lan S

Between April 2004 and July 2007, we performed 241 primary total knee replacements in 204 patients using the e.motion posterior cruciate-retaining, multidirectional mobile-bearing prosthesis. Of these, 100 were carried out using an image-free navigation system, and the remaining 141 with the conventional technique. We conducted a retrospective study from the prospectively collected data of these patients to assess the early results of this new mobile-bearing design. At a mean follow-up of 49 months (32 to 71), 18 knees (7.5%) had mechanical complications of which 13 required revision. Three of these had a peri-prosthetic fracture, and were removed from the study. The indication for revision in the remaining ten was loosening of the femoral component in two, tibiofemoral dislocation in three, disassociation of the polyethylene liner in four, and a broken polyethyene liner in one. There were eight further mechanically unstable knees which presented with recurrent disassociation of the polyethylene liner. There was no significant difference in the incidence of mechanical instability between the navigation-assisted procedures (8 of 99, 8.1%) and the conventionally implanted knees (10 of 139, 7.2%). In our view, the relatively high rate of mechanical complications and revision within 30 months precludes the further use of new design of knee replacement


Bone & Joint Open
Vol. 4, Issue 10 | Pages 801 - 807
23 Oct 2023
Walter N Szymski D Kurtz SM Lowenberg DW Alt V Lau EC Rupp M

Aims. This work aimed at answering the following research questions: 1) What is the rate of mechanical complications, nonunion and infection for head/neck femoral fractures, intertrochanteric fractures, and subtrochanteric fractures in the elderly USA population? and 2) Which factors influence adverse outcomes?. Methods. Proximal femoral fractures occurred between 1 January 2009 and 31 December 2019 were identified from the Medicare Physician Service Records Data Base. The Kaplan-Meier method with Fine and Gray sub-distribution adaptation was used to determine rates for nonunion, infection, and mechanical complications. Semiparametric Cox regression model was applied incorporating 23 measures as covariates to identify risk factors. Results. Union failure occured in 0.89% (95% confidence interval (CI) 0.83 to 0.95) after head/neck fracturs, in 0.92% (95% CI 0.84 to 1.01) after intertrochanteric fracture and in 1.99% (95% CI 1.69 to 2.33) after subtrochanteric fractures within 24 months. A fracture-related infection was more likely to occur after subtrochanteric fractures than after head/neck fractures (1.64% vs 1.59%, hazard ratio (HR) 1.01 (95% CI 0.87 to 1.17); p < 0.001) as well as after intertrochanteric fractures (1.64% vs 1.13%, HR 1.31 (95% CI 1.12 to 1.52); p < 0.001). Anticoagulant use, cerebrovascular disease, a concomitant fracture, diabetes mellitus, hypertension, obesity, open fracture, and rheumatoid disease was identified as risk factors. Mechanical complications after 24 months were most common after head/neck fractures with 3.52% (95% CI 3.41 to 3.64; currently at risk: 48,282). Conclusion. The determination of complication rates for each fracture type can be useful for informed patient-clinician communication. Risk factors for complications could be identified for distinct proximal femur fractures in elderly patients, which are accessible for therapeutical treatment in the management. Cite this article: Bone Jt Open 2023;4(10):801–807


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 801 - 810
1 Jul 2022
Krull P Steinbrück A Grimberg AW Melsheimer O Morlock M Perka C

Aims. Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA). Methods. We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model. Results. Median follow-up was 868 days (interquartile range 418 to 1,364). The offset liner design reduced the risk of revision (hazard ratio (HR) 0.68 (95% confidence interval (CI) 0.50 to 0.92)), while the angulated/offset liner increased the risk of revision for mechanical failure (HR 1.81 (95% CI 1.38 to 2.36)). The cumulative incidence of revision was lowest for the offset liner at one and seven years (1.0% (95% CI 0.7 to 1.3) and 1.8% (95% CI 1.0 to 3.0)). No difference was found between standard, lipped, and angulated liner designs. Higher age at index primary THA and an Elixhauser Comorbidity Index greater than 0 increased the revision risk in the first year after surgery. Implantation of a higher proportion of a single design of liner in a hospital reduced revision risk slightly but significantly (p = 0.001). Conclusion. The use of standard acetabular component liners remains a good choice in primary uncemented THA, as most modified liner designs were not associated with a reduced risk of revision for mechanical failure. Offset liner designs were found to be beneficial and angulated/offset liner designs were associated with higher risks of revision. Cite this article: Bone Joint J 2022;104-B(7):801–810


Bone & Joint 360
Vol. 12, Issue 4 | Pages 30 - 32
1 Aug 2023

The August 2023 Spine Roundup360 looks at: Changes in paraspinal muscles correspond to the severity of degeneration in patients with lumbar stenosis; Steroid injections are not effective in the prevention of surgery for degenerative cervical myelopathy; A higher screw density is associated with fewer mechanical complications after surgery for adult spinal deformity; Methylprednisolone following minimally invasive lumbar decompression: a large prospective single-institution study; Occupancy rate of pedicle screw below 80% is a risk factor for upper instrumented vertebral fracture following adult spinal deformity surgery; Deterioration after surgery for degenerative cervical myelopathy: an observational study from the Canadian Spine Outcomes and Research Network


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1249 - 1255
1 Nov 2022
Williamson TK Passfall L Ihejirika-Lomedico R Espinosa A Owusu-Sarpong S Lanre-Amos T Schoenfeld AJ Passias PG

Aims. Postoperative complication rates remain relatively high after adult spinal deformity (ASD) surgery. The extent to which modifiable patient-related factors influence complication rates in patients with ASD has not been effectively evaluated. The aim of this retrospective cohort study was to evaluate the association between modifiable patient-related factors and complications after corrective surgery for ASD. Methods. ASD patients with two-year data were included. Complications were categorized as follows: any complication, major, medical, surgical, major mechanical, major radiological, and reoperation. Modifiable risk factors included smoking, obesity, osteoporosis, alcohol use, depression, psychiatric diagnosis, and hypertension. Patients were stratified by the degree of baseline deformity (low degree of deformity (LowDef)/high degree of deformity (HighDef): below or above 20°) and age (Older/Younger: above or below 65 years). Complication rates were compared for modifiable risk factors in each age/deformity group, using multivariable logistic regression analysis to adjust for confounders. Results. A total of 480 ASD patients met the inclusion criteria. By two years, complication rates were 72% ≥ one complication, 28% major, 21% medical, 27% surgical, 11% major radiological, 8% major mechanical, and 22% required reoperation. Younger LowDef patients with osteoporosis were more likely to suffer either a major mechanical (odds ratio (OR) 5.9 (95% confidence interval (CI) 1.1 to 36.9); p = 0.048) or radiological complication (OR 7.0 (95% CI 1.9 to 25.9); p = 0.003). Younger HighDef patients were much more likely to develop complications if obese, especially major mechanical complications (OR 2.8 (95% CI 1.1 to 8.6); p = 0.044). Older HighDef patients developed more complications when diagnosed with depression, including major radiological complications (OR 3.5 (95% CI 1.1 to 10.6); p = 0.033). Overall, a diagnosis of depression proved to be a risk factor for the development of major radiological complications (OR 2.4 (95% CI 1.3 to 4.5); p = 0.005). Conclusion. Certain modifiable patient-related factors, especially osteoporosis, obesity, and mental health status, are associated with an increased risk of complications after surgery for spinal deformity. Surgeons should look for these conditions when assessing a patient for surgery, and optimize them to the fullest extent possible before proceeding to surgical correction so as to minimize the prospect of postoperative morbidity. Cite this article: Bone Joint J 2022;104-B(11):1249–1255


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1488 - 1496
1 Sep 2021
Emara AK Zhou G Klika AK Koroukian SM Schiltz NK Higuera-Rueda CA Molloy RM Piuzzi NS

Aims. The current study aimed to compare robotic arm-assisted (RA-THA), computer-assisted (CA-THA), and manual (M-THA) total hip arthroplasty regarding in-hospital metrics including length of stay (LOS), discharge disposition, in-hospital complications, and cost of RA-THA versus M-THA and CA-THA versus M-THA, as well as trends in use and uptake over a ten-year period, and future projections of uptake and use of RA-THA and CA-THA. Methods. The National Inpatient Sample was queried for primary THAs (2008 to 2017) which were categorized into RA-THA, CA-THA, and M-THA. Past and projected use, demographic characteristics distribution, income, type of insurance, location, and healthcare setting were compared among the three cohorts. In-hospital complications, LOS, discharge disposition, and in-hospital costs were compared between propensity score-matched cohorts of M-THA versus RA-THA and M-THA versus CA-THA to adjust for baseline characteristics and comorbidities. Results. RA-THA and CA-THA did not exhibit any clinically meaningful reduction in mean LOS (RA-THA 2.2 days (SD 1.4) vs 2.3 days (SD 1.8); p < 0.001, and CA-THA 2.5 days (SD 1.9) vs 2.7 days (SD 2.3); p < 0.001, respectively) compared to their respective propensity score-matched M-THA cohorts. RA-THA, but not CA-THA, had similar non-home discharge rates to M-THA (RA-THA 17.4% vs 18.5%; p = 0.205, and 18.7% vs 24.9%; p < 0.001, respectively). Implant-related mechanical complications were lower in RA-THA (RA-THA 0.5% vs M-THA 3.1%; p < 0.001, and CA-THA 1.2% vs M-THA 2.2%; p < 0.001), which was associated with a significantly lower in-hospital dislocation (RA-THA 0.1% vs M-THA 0.8%; p < 0.001). Both RA-THA and CA-THA demonstrated higher mean higher index in-hospital costs (RA-THA $18,416 (SD $8,048) vs M-THA $17,266 (SD $8,396); p < 0.001, and CA-THA $20,295 (SD $8,975) vs M-THA $18,624 (SD $9,226); p < 0.001, respectively). Projections indicate that 23.9% and 3.2% of all THAs conducted in 2025 will be robotic arm- and computer-assisted, respectively. Projections indicated that RA-THA use may overtake M-THA by 2028 (48.3%) and reach 65.8% of all THAs by 2030. Conclusion. Technology-assisted THA, particularly RA-THA, may provide value by lowering in-hospital early dislocation rates and and other in-hospital metrics compared to M-THA. Higher index-procedure and hospital costs warrant further comprehensive cost analyses to determine the true added value of RA-THA in the episode of care, particularly since we project that one in four THAs in 2025 and two in three THA by 2030 will use RA-THA technology. Cite this article: Bone Joint J 2021;103-B(9):1488–1496


Bone & Joint Open
Vol. 5, Issue 3 | Pages 218 - 226
15 Mar 2024
Voigt JD Potter BK Souza J Forsberg J Melton D Hsu JR Wilke B

Aims

Prior cost-effectiveness analyses on osseointegrated prosthesis for transfemoral unilateral amputees have analyzed outcomes in non-USA countries using generic quality of life instruments, which may not be appropriate when evaluating disease-specific quality of life. These prior analyses have also focused only on patients who had failed a socket-based prosthesis. The aim of the current study is to use a disease-specific quality of life instrument, which can more accurately reflect a patient’s quality of life with this condition in order to evaluate cost-effectiveness, examining both treatment-naïve and socket refractory patients.

Methods

Lifetime Markov models were developed evaluating active healthy middle-aged male amputees. Costs of the prostheses, associated complications, use/non-use, and annual costs of arthroplasty parts and service for both a socket and osseointegrated (OPRA) prosthesis were included. Effectiveness was evaluated using the questionnaire for persons with a transfemoral amputation (Q-TFA) until death. All costs and Q-TFA were discounted at 3% annually. Sensitivity analyses on those cost variables which affected a change in treatment (OPRA to socket, or socket to OPRA) were evaluated to determine threshold values. Incremental cost-effectiveness ratios (ICERs) were calculated.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 28 - 28
1 Nov 2021
Perka C Krull P Steinbrück A Morlock M
Full Access

Special acetabular polyethylene (PE) liners are intended to increase the stability of the artificial hip joint, yet registry studies on them are limited. The pupose of this study was to investigate differences in revision rates for mechanical complications in primary cementless total hip arthroplasty (THA) with standard and special PE acetabular liners in patients with ostheoarthritis. Data from the German Arthroplasty Registry (EPRD) between 2012 until 2020 were analysed. Patients with diagnosed ostheoarthritis of the hip without relevant prior surgeries, who received a primary cementless THA with a ceramic/PE bearing articulation were included. Cumulative incidences of revision for mechanical complications for Standard and 4 special PE liners (Lipped, Increased Offset, Angulated, Angulated|Increased Offset) were determined using the Kaplan-Meier Estimator. Confounding factors were investigated with a Cox proportional-hazards model. In total 151.104 cases were included. 7-year unadjusted revision-free survival for mechanical complications compared to Standard liners (97.7%) was lower for Angulated (97.4%), Lipped (97.2%) and Angulated|Increased Offset liners (94.7%), but higher for Increased Offset liners (98.1%). Risk of revision for mechanical complications was not significantly different between Standard, Lipped and Angulated liners. Increased Offset liners (HR=0.68; 95% CI=0.5–0.92) reduced, while Angulated|Increased Offset liners (HR= 1.81; 95% CI=1.38–2.36) increased the risk. Higher age at admission and an Elixhauser comorbidity index greater zero increased the risk, whereas a larger liner share slightly reduced the risk. Only the use of Increased Offset liners reduced the risk of revision for mechanical complications compared to Standard liners — other special liners did not


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 486 - 491
1 Mar 2021
Di Martino A Bordini B Ancarani C Viceconti M Faldini C

Aims. Total hip arthroplasty (THA) patients undergoing or having a prior lumbar spine fusion (LSF) have an increased risk of mechanical complications. The aim of this registry-based, retrospective comparative cohort study is to assess the longer term survival of THA in patients who have undergone a LSF during a 17-year period (2000 to 2017). Methods. A registry-based population study was conducted on 679 patients who underwent both THA and LSF surgeries. Patients were identified from the regional arthroplasty data base and cross linked to patients with LSF from the regional hospital discharge database between 2000 and 2017. Demographic data, diagnosis leading to primary THA, primary implant survival, perioperative complications, number and causes of failure, and patients requiring revision arthroplasty were collated and compared. For comparison, data from 67,919 primary THAs performed during the same time time period were also retrieved and analyzed. Results. Patients undergoing THA and LSF showed homogeneous demographic data compared to those undergoing THA alone, but a significantly lower eight-year THA implant survival (96.7 vs 96.0, p = 0.024) was observed. Moreover, THA plus LSF patients showed increased incidence of mechanical complications in the first two years after THA surgery compared to THA alone patients. Conclusion. This registry-based population study shows that approximately 679 (1%) THA patients were subjected to LSF. Patients undergoing THA and LSF have an increased risk of mechanical complications with their THA and a slightly increased risk of revision arthroplasty. Cite this article: Bone Joint J 2021;103-B(3):486–491


Bone & Joint Research
Vol. 8, Issue 10 | Pages 502 - 508
1 Oct 2019
Mao W Ni H Li L He Y Chen X Tang H Dong Y

Objectives. Different criteria for assessing the reduction quality of trochanteric fractures have been reported. The Baumgaertner reduction quality criteria (BRQC) are relatively common and the Chang reduction quality criteria (CRQC) are relatively new. The objectives of the current study were to compare the reliability of the BRQC and CRQC in predicting mechanical complications and to investigate the clinical implications of the CRQC. Methods. A total of 168 patients were assessed in a retrospective observational study. Clinical information including age, sex, fracture side, American Society of Anesthesiologists (ASA) classification, tip-apex distance (TAD), fracture classification, reduction quality, blade position, BRQC, CRQC, bone quality, and the occurrence of mechanical complications were used in the statistical analysis. Results. A total of 127 patients were included in the full analysis, and mechanical complications were observed in 26 patients. The TAD, blade position, BRQC and CRQC were significantly associated with mechanical complications in the univariate analysis. Only the TAD (p = 0.025) and the CRQC (p < 0.001) showed significant results in the multivariate analysis. In the comparison of the receiver operating characteristic curves, the CRQC also performed better than the BRQC. Conclusion. The CRQC are reliable in predicting mechanical complications and are more reliable than the BRQC. Future studies could use the CRQC to assess fracture reduction quality. Intraoperatively, the surgeon should refer to the CRQC to achieve good reduction in trochanteric fractures. Cite this article: Bone Joint Res 2019;8:502–508


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 55 - 63
1 Jan 2020
Hagberg K Ghassemi Jahani S Kulbacka-Ortiz K Thomsen P Malchau H Reinholdt C

Aims. The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. Methods. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded. Results. The Q-TFA scores at two, five, seven, and ten years showed significantly more prosthetic use, better mobility, fewer problems, and an improved global situation, compared with baseline. The survival rate of the osseointegrated implant part (the fixture) was 89% and 72% after seven and 15 years, respectively. A total of 61 patients (55%) had mechanical complications (mean 3.3 (SD 5.76)), resulting in exchange of the percutaneous implant parts. There was a positive relationship between a higher activity grade and the number of mechanical complications. Conclusion. Compared with before treatment, the patient-reported outcome was significantly better and remained so over time. Although osseointegration and the ability to transfer loads over a 15-year period have been demonstrated, a large number of mechanical failures in the external implant parts were found. Since these were related to higher activity, restrictions in activity and improvements to the mechanical properties of the implant system are required. Cite this article: Bone Joint J 2020;102-B(1):55–63


Bone & Joint Open
Vol. 2, Issue 3 | Pages 141 - 149
1 Mar 2021
Saab M Chick G

Aims. The objective of this systematic review was to describe trapeziectomy outcomes and complications in the context of osteoarthritis of the base of the thumb after a five-year minimum follow-up. Methods. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to guide study design, and 267 full-text articles were assessed for eligibility. After exclusion criteria application, 22 studies were included, involving 728 patients and 823 trapeziectomies. Outcomes included pre- and postoperative clinical and radiological characteristics. Complications and revisions were recorded. Results. All the studies reported good results regarding pain and range of motion at the last follow-up of 8.3 years (5 to 22); the mean satisfaction rate was 91% (84% to 100%). It was difficult to assess the impact on metacarpophalangeal joint motion in extension with contrary results. The key pinch returned to its preoperative values, whereas tip pinch showed a modest improvement (+14%), with a mild improvement found in grip strength (+25%) at the last follow-up. The mean progressive trapezial collapse was 48% (0% to 85%) and was not correlated with pain, grip strength, or satisfaction. The most represented complications were linked to tendons or nerves affected during additional procedures to stabilize the joint (11.6%; n = 56). Mechanical complications included symptomatic scapho-M1 impingement (3.1%; n = 15/580), leading to nine surgical revisions out of 581 trapeziectomies. Meta-analysis was not possible due to study heterogeneity and limited data. Conclusion. After a minimum five-year follow-up, trapeziectomy achieved high patient satisfaction and pain relief. However, strength seemed to be deteriorating with detrimental consequences, but this did not correlate with trapezial collapse. The issues related to underestimating mechanical complications and varying degrees of success should be highlighted in the information given to patients. Evidence-based analyses should help the surgeon in their decision-making. Cite this article: Bone Jt Open 2021;2(3):141–149


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 8 - 8
7 Nov 2023
Crawford H Baroncini A Field A Segar A
Full Access

7% of adolescent idiopathic scoliosis (AIS) patients also present with a pars defect. To date, there are no available data on the results of fusion ending proximal to a spondylolysis in the setting of AIS. The aim of this study was to analyze the outcomes of posterior spinal fusion (PSF) in this patient cohort, to investigate if maintaining the lytic segment unfused represents a safe option. Retrospective review of all patients who received PSF for AIS, presented with a spondylolysis or spondylolisthesis and had a min. 2-years follow-up. Demographic data, instrumented levels and preoperative radiographic data were collected. Mechanical complications, coronal or sagittal parameters, amount of slippage and pain levels were evaluated. Data from 22 patients were available (age 14.4 ± 2.5 years), 18 Lenke 1–2 and four Lenke 3–6. Five patients (24%) had an isthmic spondylolisthesis, all Meyerding I. The mean preoperative Cobb angle of the instrumented curves was 58 ± 13°. For 18 patients the lowest instrumented vertebra (LIV) was the last touched vertebra (LTV); for two LIV was distal to the LTV; for two, LIV was one level proximal to the LTV. The number of segments between the LIV and the lytic vertebra ranged from 1 to 6. At the last follow-up, no complications were observed. The residual curve below the instrumentation measured 8.5 ± 6.4°, the lordosis below the instrumented levels was 51.4 ± 13°. The magnitude of the isthmic spondylolisthesis remained constant for all included patients. Three patients reported minimal occasional low back pain. The LTV can be safely used as LIV when performing PSF for the management of AIS in patients with L5 spondylolysis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 5 - 5
8 Feb 2024
Ablett AD McCann C Feng T Macaskill V Oliver WM Keating JF
Full Access

This study compares outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual lag screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or peri-implant fracture. Technical factors associated with mechanical failure were also identified. All adult patients (>18yrs) with a subtrochanteric femoral fracture treated in a single centre were retrospectively identified using electronic records. Included patients underwent surgical fixation using either a long GN (2010–2017) or IN (2017–2022). Cox regression analysis was used to determine the risk of mechanical failure and technical predictors of failure. The study included 587 patients, 336 in the GN group (median age 82yrs, 73% female) and 251 in the IN group (median age 82yrs, 71% female). The IN group exhibited a higher prevalence of osteoporosis (p=0.002) and CKD□3 (p=0.007). There were no other baseline differences between groups. The risk of any mechanical failure was increased two-fold in the GN group (HR 2.51, p=0.020). Mechanical failure comprising screw cut-out (p=0.040), back-out (p=0.040) and nail breakage (p=0.51) was only observed in the GN group. The risk of peri-implant fracture was similar between the groups (HR 1.10, p=0.84). Technical predictors of mechanical included varus >5° for cut-out (HR 15.61, p=0.016), TAD>25mm for back-out (HR 9.41, p=0.020) and shortening >1cm for peri-implant fracture (HR 6.50, p=<0.001). Dual lag screw designs may reduce the risk of mechanical complications for patients with subtrochanteric femoral fractures


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 36 - 36
1 Oct 2022
Minea C Rubio AA Moreno JE Correa JJA
Full Access

Aim. Prosthetic joint replacement is more commonly done in the elderly group of patients due to an increase pathology related to joint degeneration that comes with age. In this age group is also more frequent having underling condition that may predispose to a prosthetic joint infection. Also, the pharmacological intervention in those patients may play an important role as a risk factor for infection after joint replacement surgery. The use of oral anticoagulants seems to be particularly increased in elderly patients but there aren't enough data published to support an association between prosthetic joint infection and the use of oral anticoagulants. Identifying risk factors in elderly patients age >75 years old with a special focus on the oral anticoagulation therapy is the aim of the study. Methods. In a retrospective study from 2011 till 2018 all the patients >75 years old with knee and hip replacement surgery have been review looking for acute prosthetic infection and risk factors that may be predispose to it. Patients with previous surgery or any other mechanical complication that needed intervention on the same area have been excluded. Results. A total of 1220 patients have been included (801 knee replacement surgery and 419 hip replacement surgery). The mean age was 79.5 ± 3.44 years and most of the patients were women (72,6%). The infection rate was 2,5%. Several factors have been identified to be associated with acute infection. (Table.1.). The patients receiving oral anticoagulants had an increased risk of infection (OR 3.63 (1.60–7.74), p=0.002). Conclusions. Even all the risk factors associated with risk infection have been described previously, the relevant aspect is the increased risk of prosthetic joint infection in patients receiving oral anticoagulants


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 79 - 79
19 Aug 2024
Hormi-Menard M Wegrzyn J Girard J Faure P Duhamel A Erivan R Migaud H
Full Access

The results of total hip arthroplasty (THA) revisions to correct leg length discrepancy (LLD) are not clear, with only two former limited series (< 25 patients). Therefore, we conducted a retrospective study of THA revisions for LLD to determine: 1) the change in LLD, 2) the function outcomes and whether obtaining equal leg lengths influenced function, 3) the complication and survival rates. This multicenter study included 57 patients: 42 THA revisions for limb shortening and 15 revisions for limb lengthening. LLD was measured on conventional radiographs and EOS. The Oxford-12 and FJS outcome scores were collected and the number of patients achieving the Oxford-12 MCID. The revisions were carried out a mean of 2.8 years after the index THA. The median LLD decreased from 7.5 mm (IQR: [5;12]) to 1 mm (IQR: [0.5;2.5]) at follow-up (p=0.0002). Overall, 55 of 57 patients (96%) had < 5 mm LLD at follow-up and 12 patients (21%) had equal leg lengths. The complication rate was 25%: 12 mechanical complications (8 periprosthetic femoral fractures, 2 stem loosening and 1 cup loosening, 1 dislocation) and 1 periprosthetic infection. The patient satisfaction was high with a median FJS of 79.2/100 and 77% of patients reached the Oxford-12 MCID. Lengthening procedures had significantly worst function than shortening (38% vs 91% of patients achieving the Oxford-12 MCID (p=0.0004)). Survivorship was 85% (95% CI: 77.9 – 92.5) at 2 years and 77% (95% CI: 66.3 – 87.1) at 4.6 years when using re-revision for any reason as the endpoint. When LLD after THA does not respond to conservative management, revision THA should be considered. Although revision THA for LLD improved medium-term functional outcomes with a high patient satisfaction rate, especially for shortening procedures, the complication rate was high, particularly related to periprosthetic femoral fracture


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 55 - 55
2 May 2024
McCann C Ablett A Feng T Macaskill V Oliver W Keating J
Full Access

Subtrochanteric femoral fractures are a subset of hip fractures generally treated with cephalomedullary nail fixation\[1\]. Single lag screw devices are most commonly-used, but integrated dual screw constructs have become increasingly popular\[2,3\]. The aim of this study was to compare outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or peri-implant fracture. Consecutive adult patients (18yrs) with subtrochanteric femoral fracture treated in a single centre were retrospectively identified using electronic records. Patients that underwent surgical fixation using either a long GN (2010–2017) or IN (2017–2022) were included. Medical records and radiographs were reviewed to identify complications of fixation. Cox regression analysis was used to determine the risk of mechanical failure and secondary outcomes by implant design. Multivariable regression models were used to identify predictors of mechanical failure. The study included 622 patients, 354 in the GN group (median age 82yrs, 72% female) and 268 in the IN group (median age 82yrs, 69% female). The risk of any mechanical failure was increased two-fold in the GN group (HR 2.44 \[95%CI 1.13 to 5.26\]; _p=0.024_). Mechanical failure comprising screw cut-out (_p=0.032_), back-out (_p=0.032_) and nail breakage (_p=0.26_) was only observed in the GN group. Technical predictors of failure included varus >5° for cut-out (OR 19.98 \[2.06 to 193.88\]; _p=0.01_), TAD;25mm for back-out (8.96 \[1.36 to 58.86\]; p=0.022) and shortening 1cm for peri-implant fracture (7.81 \[2.92 to 20.91\]; _p=<0.001_). Our results demonstrate that an intercalated screw construct is associated with a lower risk of mechanical failure compared with the a single lag screw device. Intercalated screw designs may reduce the risk of mechanical complications for patients with subtrochanteric femoral fractures


Bone & Joint Open
Vol. 4, Issue 7 | Pages 539 - 550
21 Jul 2023
Banducci E Al Muderis M Lu W Bested SR

Aims. Safety concerns surrounding osseointegration are a significant barrier to replacing socket prosthesis as the standard of care following limb amputation. While implanted osseointegrated prostheses traditionally occur in two stages, a one-stage approach has emerged. Currently, there is no existing comparison of the outcomes of these different approaches. To address safety concerns, this study sought to determine whether a one-stage osseointegration procedure is associated with fewer adverse events than the two-staged approach. Methods. A comprehensive electronic search and quantitative data analysis from eligible studies were performed. Inclusion criteria were adults with a limb amputation managed with a one- or two-stage osseointegration procedure with follow-up reporting of complications. Results. A total of 19 studies were included: four one-stage, 14 two-stage, and one article with both one- and two-stage groups. Superficial infection was the most common complication (one-stage: 38% vs two-stage: 52%). There was a notable difference in the incidence of osteomyelitis (one-stage: nil vs two-stage: 10%) and implant failure (one-stage: 1% vs two-stage: 9%). Fracture incidence was equivocal (one-stage: 13% vs two-stage: 12%), and comparison of soft-tissue, stoma, and mechanical related complications was not possible. Conclusion. This review suggests that the one-stage approach is favourable compared to the two-stage, because the incidence of complications was slightly lower in the one-stage cohort, with a pertinent difference in the incidence of osteomyelitis and implant failure. Cite this article: Bone Jt Open 2023;4(7):539–550


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 10 - 10
1 Dec 2022
Rizkallah M Ferguson P Basile G Werier JM Kim P Wilson D Turcotte R
Full Access

The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17–86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 96 - 96
1 Dec 2022
Rizkallah M Ferguson P Basile G Werier JM Kim P Wilson D Turcotte R
Full Access

The reconstruction of peri-acetabular defects after severe bone loss or pelvic resection for tumor is among the most challenging surgical intervention. The Lumic® prosthesis (Implantcast, Buxtehude, Germany) was first introduced in 2008 in an effort to reduce the mechanical complications encountered with the classic peri-acetabular reconstruction techniques and to improve functional outcomes. Few have evaluated the results associated with the use of this recent implant. A retrospective study from five Orthopedic Oncology Canadian centers was conducted. Every patient in whom a Lumic® endoprosthesis was used for reconstruction after peri-acetabular resection or severe bone loss with a minimal follow-up of three months was included. The charts were reviewed and data concerning patients’ demographics, peri-operative characteristics and post-operative complications was collected. Surgical and functional outcomes were also assessed. Sixteen patients, 11 males and five females, were included and were followed for 28 months [3 – 60]. Mean age was 55 [17-86], and mean BMI reached 28 [19.6 – 44]. Twelve patients (75%) had a Lumic® after a resection of a primary sarcoma, two following pelvic metastasis, one for a benign tumor and one after a comminuted acetabular fracture with bone loss. Twelve patients (75%) had their surgery performed in one stage whereas four had a planned two-stage procedure. Mean surgical time was 555 minutes [173-1230] and blood loss averaged 2100 mL [500-5000]. MSTS score mean was 60.3 preoperatively [37.1 – 97] and 54.3 postoperatively [17.1-88.6]. Five patients (31.3%) had a cemented Lumic® stem. All patients got the dual mobility bearing, and 10 patients (62.5%) had the largest acetabular cup implanted (60 mm). In seven of these 10 patients the silver coated implant was used to minimize risk of infection. Five patients (31.3%) underwent capsular reconstruction using a synthetic fabric aiming to reduce the dislocation risk. Five patients had per-operative complications (31.3%), four were minor and one was serious (comminuted iliac bone fracture requiring internal fixation). Four patients dislocated within a month post-operatively and one additional patient sustained a dislocation one year post-operatively. Eight patients (50%) had a post-operative surgical site infection. All four patients who had a two-stage surgery had an infection. Ten patients (62.5%) needed a reoperation (two for fabric insertion, five for wash-outs, and three for implant exchange/removal). One patient (6.3%) had a septic loosening three years after surgery. At the time of data collection, 13 patients (81.3%) were alive with nine free of disease. Silver coating was not found to reduce infection risk (p=0.2) and capsuloplasty did not prevent dislocation (p=1). These results are comparable to the sparse data published. Lumic® endoprosthesis is therefore shown to provide good functional outcomes and low rates of loosening on short to medium term follow-up. Infection and dislocation are common complications but we were unable to show benefits of capsuloplasty and of the use of silver coated implants. Larger series and longer follow-ups are needed