Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 15 - 15
17 Apr 2023
Inglis B Inacio J Dailey H
Full Access

Virtual mechanical testing is a method for measuring bone healing using finite element models built from computed tomography (CT) scans. Previously, we validated a dual-zone material model for ovine fracture callus that differentiates between mineralized woven bone and soft tissue based on radiodensity. 1. The objective of this study was to translate the dual-zone material model from sheep to two important clinical scenarios: human tibial fractures in early-stage healing and late-stage nonunions. CT scans for N = 19 tibial shaft fractures were obtained prospectively at 12 weeks post-op. A second group of N = 33 tibial nonunions with CT scans were retrospectively identified. The modeling techniques were based on our published method. 2. The dual-zone material model was implemented for humans by performing a cutoff sweep for both the 12-week and nonunion groups. Virtual torsional rigidity (VTR) was calculated as VTR = ML/φ [N-m. 2. /°], where M is the moment reaction, L is the diaphyseal segment length, and φ is the angle of twist. As the soft tissue cutoff was increased, the rigidity of the clinical fractures decreased and soft tissue located within the fracture gaps produced higher strains that are not predicted without the dual zone approach. The structural integrity of the nonunions varied, ranging from very low rigidities in atrophic cases to very high rigidities in highly calcified hypertrophic cases, even with dual-zone material modeling. Human fracture calluses are heterogeneous, comprising of woven bone and interstitial soft tissue. Use of a dual-zone callus material model may be instrumental in identifying delayed unions during early healing when callus formation is minimal and/or predominantly fibrous with little mineralization. ACKNOWLEDGEMENTS:. This work was supported by the National Science Foundation (NSF) grant CMMI-1943287


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 127 - 127
14 Nov 2024
Strack D Rayudu NM Kirschke J Baum T Subburaj K
Full Access

Introduction. Patient-specific biomechanical modeling using Finite Element Analysis (FEA) is pivotal for understanding the structural health of bones, optimizing surgical procedures, assessing outcomes, and validating medical devices, aligning with guidance issued by standards and regulatory bodies. Accurate mapping of image-to-mesh-material is crucial given bone's heterogeneous composition. This study aims to rigorously assess mesh convergence and evaluate the sensitivity of material grouping strategies in quantifying bone strength. Method. Subject-specific geometry and nonlinear material properties were derived from computed tomography (CT) scan data of one cadaveric human vertebral body. Linear tetrahedral elements with varying edge lengths between 2mm and 0.9mm were then generated to study the mesh convergence. To compare the effectiveness of different grouping strategies, three approaches were used: Modulus Gaping (a user-defined absolute threshold of Young's modulus ranging from 500 MPa to 1 MPa), Percentual Thresholding (relative parameter thresholds ranging from 50% to 1%), and Adaptive clustering (unsupervised k-means-based clustering ranging from 10 to 200 clusters). Adaptive clustering enables a constant number of unique material properties in cross-specimen studies, improving the validity of results. Result. Mesh convergence was evaluated via fracture load and reached at a 1mm mesh size across grouping strategies. All strategies exhibit minimal deviation (within 5%) from individually assigned material parameters, except Modulus Gaping, with a 500 MPa threshold (32% difference). Computational efficiency, measured by runtime, significantly improved with grouping strategies, reducing computational cost by 82 to 94% and unique material count by up to 99%. Conclusion. Different grouping strategies offer comparable mesh convergence, highlighting their potential to reduce computational complexity while maintaining accuracy in the biomechanical modeling of bones and suggesting a more efficient approach than individual element materials. The higher efficiency of FEA may increase its applicability in clinical settings with limited computational resources. Further studies are needed to refine grouping parameters and assess their suitability across different subjects


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 2 - 2
22 Nov 2024
Roskar S Faganeli N Mihalic R Trebse R
Full Access

Aim. Arthroscopic interventions have revolutionized the treatment of joint pathologies. The appropriate diagnostics and treatment are required for infections after ligament reconstructions using non-resorbable material such as tendon grafts, anchors, and sutures, prone to biofilm formation. The infection rate is around 1% for knee and shoulder, while up to 4% for Achilles tendon reconstructions. Despite high number of these procedures worldwide, there is limited evidence about the best treatment protocol. Our study aimed to provide a general protocol for the treatment of small implants for soft tissue reconstruction. Method. Between 2019 and 2023, we treated 48 infections of ligament, meniscus, and tendon reconstructions out of 7291 related procedures performed in the same time period. Early infection (<30 days) were treated with an arthroscopic debridement and implant retention (DAIR), except Achilles tendons had open DAIR, while those with delayed or chronic infection (>30 days) were treated with extensive debridement and lavage combined with one-stage exchange (OSE) or implant removal. During surgery, at least 5 microbiological s and samples for histopathology were obtained. The removed material was sonicated. After surgery, all patients were one week on iv. antibiotics, followed by oral antibiofilm antibiotics for 6 weeks including rifampicin and/or a quinolone. All patients were followed for at least 1 year. Failure was defined as the need for additional revision surgery after finished iv. antibiotic treatment. Results. Among 48 patients, 38 were early and 10 were late acute or chronic infections. The incidence of infection for our cohort was 0.7%. We observed 27 infections after ligament reconstruction of the knee, 15 of the shoulder, 5 of the ankle, and 1 infection of the elbow joint. 40 patients were treated with DAIR, 5 with OSE, and 3 with implant removal. We had 11 C. acnes, 10 S. aureus, 6 S. epidermidis, 2 P. aeruginosa, 2 S. lugdunensis, 10 mixed flora, and 3 culture-negative infections. 12 patients received antibiotics before surgery, and all culture-negative infections were related to this subgroup. We observed 2 failures, both in a combination of proximal tibial osteotomy and ligament reconstruction of the knee joint. The success rate of our protocol was 96%. Conclusions. Prompt surgical treatment followed by 6 weeks of antibiotic treatment cured 96% of infections of small implants after reconstruction procedures of knee, shoulder, and ankle joints. Our study is the first to provide a treatment protocol for infections of small implants after ligament reconstruction procedures


Bone & Joint Research
Vol. 9, Issue 11 | Pages 768 - 777
2 Nov 2020
Huang C Lu Y Hsu L Liau J Chang T Huang C

Aims. The material and design of knee components can have a considerable effect on the contact characteristics of the tibial post. This study aimed to analyze the stress distribution on the tibial post when using different grades of polyethylene for the tibial inserts. In addition, the contact properties of fixed-bearing and mobile-bearing inserts were evaluated. Methods. Three different grades of polyethylene were compared in this study; conventional ultra high molecular weight polyethylene (UHMWPE), highly cross-linked polyethylene (HXLPE), and vitamin E-stabilized polyethylene (VEPE). In addition, tibial baseplates with a fixed-bearing and a mobile-bearing insert were evaluated to understand differences in the contact properties. The inserts were implanted in neutral alignment and with a 10° internal malrotation. The contact stress, von Mises stress, and equivalent plastic strain (PEEQ) on the tibial posts were extracted for comparison. Results. The stress and strain on the tibial post for the three polyethylenes greatly increased when the insert was placed in malrotation, showing a 38% to 56% increase in von Mises stress and a 335% to 434% increase in PEEQ. The VEPE insert had the lowest PEEQ among the three materials. The mobile-bearing design exhibited a lower increase in stress and strain around the tibial posts than the fixed-bearing design. Conclusion. Using VEPE for the tibial component potentially eliminates the risk of material permanent deformation. The mobile-bearing insert can help to avoid a dramatic increase in plastic strain around the tibial post in cases of malrotation. The mobility allows the pressure to be distributed on the tibial post and demonstrated lower stresses with all three polyethylenes simulated. Cite this article: Bone Joint Res 2020;9(11):768–777


Bone & Joint Research
Vol. 11, Issue 11 | Pages 835 - 842
17 Nov 2022
Wiesli MG Livio F Achermann Y Gautier E Wahl P

Aims. There is a considerable challenge in treating bone infections and orthopaedic device-associated infection (ODAI), partly due to impaired penetration of systemically administrated antibiotics at the site of infection. This may be circumvented by local drug administration. Knowledge of the release kinetics from any carrier material is essential for proper application. Ceftriaxone shows a particular constant release from calcium sulphate (CaSO. 4. ) in vitro, and is particularly effective against streptococci and a large portion of Gram-negative bacteria. We present the clinical release kinetics of ceftriaxone-loaded CaSO. 4. applied locally to treat ODAI. Methods. A total of 30 operations with ceftriaxone-loaded CaSO. 4. had been performed in 28 patients. Ceftriaxone was applied as a single local antibiotic in 21 operations and combined with vancomycin in eight operations, and in an additional operation with vancomycin and amphotericin B. Sampling of wound fluid was performed from drains or aspirations. Ceftriaxone concentrations were measured by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Results. A total of 37 wound fluid concentrations from 16 operations performed in 14 patients were collected. The ceftriaxone concentrations remained approximately within a range of 100 to 200 mg/l up to three weeks. The median concentration was 108.9 mg/l (interquartile range 98.8 to 142.5) within the first ten days. No systemic adverse reactions were observed. Conclusion. Our study highlights new clinical data of locally administered ceftriaxone with CaSO. 4. as carrier material. The near-constant release of ceftriaxone from CaSO. 4. observed in vitro could be confirmed in vivo. The concentrations remained below known local toxicity thresholds. Cite this article: Bone Joint Res 2022;11(11):835–842


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1310 - 1319
1 Oct 2018
Langton DJ Wells SR Joyce TJ Bowsher JG Deehan D Green S Nargol AVF Holland JP

Aims. There are limited published data detailing the volumetric material loss from tapers of conventional metal-on-polyethylene (MoP) total hip arthroplasties (THAs). Our aim was to address this by comparing the taper wear rates measured in an explanted cohort of the widely used Exeter THA with those measured in a group of metal-on-metal (MoM) THAs. Patients and Methods. We examined an existing retrieval database to identify all Exeter V40 and Universal MoP THAs. Volumetric wear analysis of the taper surfaces was conducted using previously validated methodology. These values were compared with those obtained from a series of MoM THAs using non-parametric statistical methodology. A number of patient and device variables were accounted for using multiple regression modelling. Results. A total of 95 Exeter MoP and 249 MoM THAs were examined. The median volumetric loss from the MoM cohort was over four times larger than that from the MoP cohort (1.01 mm. 3. vs 0.23 mm. 3. , p < 0.001), despite a significantly shorter median period in vivo for the MoM group (48 months vs 90 months, p < 0.001). Multiple regression modelling indicated that the dominant variables leading to greater female taper material loss were bearing diameter (p < 0.001), larger female taper angles (p < 0.001), and male titanium stem tapers (p < 0.001). Conclusion. Consistent with the long-term clinical success of the device, the volumetric material loss from Exeter femoral head tapers was, in general, small compared with that from larger-diameter MoM head tapers. Cite this article: Bone Joint J 2018;100-B:1310–9


Bone & Joint Research
Vol. 8, Issue 11 | Pages 563 - 569
1 Nov 2019
Koh Y Lee J Lee H Kim H Kang K

Objectives. Unicompartmental knee arthroplasty (UKA) is an alternative to total knee arthroplasty with isolated medial or lateral compartment osteoarthritis. However, polyethylene wear can significantly reduce the lifespan of UKA. Different bearing designs and materials for UKA have been developed to change the rate of polyethylene wear. Therefore, the objective of this study is to investigate the effect of insert conformity and material on the predicted wear in mobile-bearing UKA using a previously developed computational wear method. Methods. Two different designs were tested with the same femoral component under identical kinematic input: anatomy mimetic design (AMD) and conforming design inserts with different conformity levels. The insert materials were standard or crosslinked ultra-high-molecular-weight polyethylene (UHMWPE). We evaluated the contact pressure, contact area, wear rate, wear depth, and volumetric wear under gait cycle loading conditions. Results. Conforming design inserts had the lower contact pressure and larger contact area. However, they also had the higher wear rate and volumetric wear. The improved wear performance was found with AMD inserts. In addition, the computationally predicted volumetric wear of crosslinked UHMWPE inserts was less than half that of standard UHMWPE inserts. Conclusion. Our results showed that increasing conformity may not be the sole predictor of wear performance; highly crosslinked mobile-bearing polyethylene inserts can also provide improvement in wear performance. These results provide improvements in design and materials to reduce wear in mobile-bearing UKA. Cite this article: Bone Joint Res 2019;8:563–569


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 19 - 19
2 Jan 2024
Li R Zheng J Smith P Chen X
Full Access

Device-associated bacterial infections are a major and costly clinical challenge. This project aimed to develop a smart new biomaterial for implants that helps to protect against infection and inflammation, promote bone growth, and is biodegradable. Gallium (Ga) doped strontium-phosphate was coated on pure Magnesium (Mg) through a chemical conversion process. Mg was distributed in a graduated manner throughout the strontium-phosphate coating GaSrPO4, with a compact structure and a Ga-rich surface. We tested this sample for its biocompatibility, effects on bone remodeling and antibacterial activities including Staphylococcus aureus, S. epidermidis and E. coli - key strains causing infection and early failure of the surgical implantations in orthopaedics and trauma. Ga was distributed in a gradient way throughout the entire strontium-phosphate coating with a compact structure and a gallium-rich surface. The GaSrPO4 coating protected the underlying Mg from substantial degradation in minimal essential media at physiological conditions over 9 days. The liberated Ga ions from the coatings upon Mg specimens inhibited the growth of bacterial tested. The Ga dopants showed minimal interferences with the SrPO4 based coating, which boosted osteoblasts and undermined osteoclasts in in vitro co-cultures model. The results evidenced this new material may be further translated to preclinical trial in large animal model and towards clinical trial. Acknowledgements: Authors are grateful to the financial support from the Australian Research Council through the Linkage Scheme (ARC LP150100343). The authors acknowledge the facilities, and the scientific and technical assistance of the RMIT University and John Curtin School of Medical Research, Australian National University


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 85 - 85
1 Feb 2020
Dennis D Pierrepont J Madurawe C Lee G Shimmin A
Full Access

Introduction. It is well accepted that larger heads provide more stability in total hip arthroplasty. This is due to an increase in jump height providing increased resistance to subluxation. However, other implant parameters also contribute to the bearing's stability. Specifically, the liner's rim design and the centre of rotation relative to the liner's face. Both these features contribute to define the Cup Articular Arc Angle (CAAA). The CAAA describes the degree of dysplasia of the acetabular liner, and plays an important role in defining the jump height. The aim of this study was to determine the difference in jump height between bearing materials with a commonly used acetabular implant system. Methods. From 3D models of the Trinity acetabular implant system (Corin, UK), the CAAA was measured in CAD software (SolidWorks, Dassault Systems, France) for the ceramic, poly and modular dual mobility (DM) liners, for cup sizes 46mm to 64mm. The most commonly used bearing size was used in the analysis of each cup size. For the ceramic and poly liners, a 36mm bearing was used for cups 50mm and above. For the 46mm and 48mm cups, a 32mm bearing was used. The DM liners were modelled with the largest head size possible. Using a published equation, the jump height was calculated for each of the three bearing materials and each cup size. Cup inclination and anteversion were kept constant. Results. CAAA varied substantially between cup sizes and bearing materials. The mean CAAA for the ceramic, poly and DM bearings were 166°, 175° and 186°, respectively. Consequently, over the entire size range, the ceramic liners had the lowest mean jump height of 12.9mm. In comparison to the ceramic liner, there was a mean 10% increase in jump height when transitioning to a poly (14.2mm), and a further 30% increase when transitioning from a poly to the dual mobility bearing (18.5mm) [Fig.1]. However, the difference in jump heights between bearings was variable, and dependent on cup size. Discussion. It is well understood that increasing head size increases stability in THA. However, other implant design parameters contribute to stability. With this particular implant system, the poly bearing had a greater jump height than the ceramic for cup sizes 50mm and above. The DM bearing improved jump height over the ceramic and poly by a mean of 41% and 30%, respectively. In conclusion, different liners have different design features that affect jump height. Consequently, not all bearings of identical head size are the same. We encourage a dialogue with your implant provider to understand the differences in CAAA between cup sizes and bearing materials. For any figures or tables, please contact the authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1348 - 1354
1 Oct 2011
Vanbiervliet J Bellemans J Verlinden C Luyckx J Labey L Innocenti B Vandenneucker H

Complications involving the patellofemoral joint, caused by malrotation of the femoral component during total knee replacement, are an important cause of persistent pain and failure leading to revision surgery. The aim of this study was to determine and quantify the influence of femoral component malrotation on patellofemoral wear, and to determine whether or not there is a difference in the rate of wear of the patellar component when articulated against oxidised zirconium (OxZr) and cobalt-chrome (CoCr) components. An in vitro method was used to simulate patellar maltracking for both materials. Both rates of wear and changes in height on the patellar articular surface were measured. The mean rates of wear measured were very small compared to standard tibiofemoral wear rates. When data for each femoral component material were pooled, the mean rate of wear was 0.19 mm. 3. /Mcycle (. sd. 0.21) for OxZr and 0.34 mm. 3. /Mcycle (. sd. 0.335) for CoCr. The largest change in height on each patella varied from -0.05 mm to -0.33 mm over the different configurations. The results suggest that patellar maltracking due to an internally rotated femoral component leads to an increased mean patellar wear. Although not statistically significant, the mean wear production may be lower for OxZr than for CoCr components


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 88 - 88
1 Mar 2021
Elahi SA Fehervary H Famaey N Jonkers I
Full Access

To unravel the relation between mechanical loading and biological response, cell-seeded hydrogel constructs can be used in bioreactors under multi-axial loading conditions that combines compressive with torsional loading. Typically, considerable biological variation is observed. This study explores the potential confounding role of mechanical factors in multi-directional loading experiments. Indeed, depending on the material properties of the constructs and characteristics of the mechanical loading, the mechanical environment within the constructs may vary. Consequently, the local biological response may vary from chondrogenesis in some parts to proteoglycan loss in others. This study uses the finite element method to investigate the effects of material properties of cell-seeded constructs and multiaxial loading characteristics on local mechanical environment (stresses and strains) and relate these to chondrogenesis (based on maximum compressive principal strain (MCPS) - Zahedmanesh et al., 2014) and proteoglycan loss (based on fluid velocity (FV) - Orozco et al., 2018). The construct was modelled as a homogenized poro-hyperelastic (using a Neohookean model and Darcys law) cylinder of 8mm diameter and equal height using Abaqus. The bottom surface was fully constrained and dynamic unconfined compression and torsion loading were applied to the top surface. Free fluid flow was allowed through the lateral surface. We studied the sensitivity of the maximum values of the target parameters at 9 key locations to the material parameters and loading characteristics. Six input parameters were varied in preselected ranges: elastic modulus (E=[20,80]kPa), Poissons ratio (nu=[0.1,0.4]), permeability (k=[1,4]e-12m4/Ns), compressive strain (Comp=[5,20]%), rotation (Rot=[5,20]°) and loading frequency (Freq=[1,4]Hz). A full-factorial design of experiment method was used and a first-order polynomial surface including the interactions fitted the responses. MCPS varies between 7.34% and 33.52% and is independent of the material properties (E, nu and k) and Freq but has a high dependency on Comp and a limited dependency on Rot. The maximum value occurs centrally in the construct, except for high values of Rot and low Comp where it occurs at the edges. FV vary between 0.0013mm/sec and 0.1807mm/sec and dominantly depends on E, k and Comp, while its dependency on Rot and Freq is limited. The maximum value usually occurs at the edges, although at high Freq it may move towards the center of the superficial and deep zones. This study can be used as a guideline for the optimized selection of mechanical parameters of hydrogel for cell-seeded constructs and loading conditions in multi-axial bioreactor studies. In future work, we will study the effect in intact and injured cartilage explants


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 11 - 11
1 Feb 2020
Ruhr M Polster V Morlock M
Full Access

INTRODUCTION. Precise determination of material loss is essential for failure analysis of retrieved hip cups. To determine wear, the measured geometry of the retrieval hast to be compared to its pristine geometry, which usually is not available. There are different approaches to generate reference geometries to approximate the pristine geometry that is commonly assumed as sphere. However, the geometry of press fit cup retrievals might not be spherical due to deformation caused by excessive press-fitting. The effect of three different reference geometries on the determined wear patterns and material loss of pristine and worn uncemented metal-on-metal hip cups was determined. METHODS. The surfaces of two cups (ASR, DePuy, Leeds; one pristine, one a worn retrieval) were digitized using a coordinate measurement machine (CRYSTA-Apex S574, Mitutoyo; 3 µm accuracy). Both cups were measured undeformed and while being deformed between a clamp. Three different methods for generating reference geometries were investigated (PolyWorks|Inspector 2018, InnovMetric). Method 1: A sphere with the nominal internal cup dimensions was generated. Method 2: A sphere was fitted to the measured data points after removing those from worn areas (deviation > 3 µm is defined as wear) to eliminate the influence of manufacturing tolerances on the nominal diameter. Method 3: Measurements, which displayed visual deformation in the computed wear pattern based on the best fit sphere, were fitted with an ellipsoid. The direction of the deformation axes and the amount of deformation were used to scale the best fit ellipsoid. Linear wear was calculated from the distance of the respective reference geometry to the measured point cloud. Finally, material loss is defined as the difference in volume of the reference geometry and the measured geometry. RESULTS. The method used for generating the reference geometry affected the determined wear greatly. Using the nominal manufacturing radius (larger than the best fit radius) for the worn cup falsely indicates deposit. This leads to approx. 39 % less wear volume compared to the best fit sphere analysis. Using an ellipsoid as reference geometry for both deformed cups improves the determination of the wear pattern and indicates areas of material loss better than a reference sphere. Additionally, the mistake in material loss determination is decreased, especially for the worn cup almost exactly to the wear volume analyzed with the best fit sphere before deformation. DISCUSSION. For correct determination of material loss best fit geometries instead of nominal sizes have to be used to compensate the differences due to manufacturing tolerances. Furthermore, deformation always has to be eliminated to generate correct wear patterns and volumes. Using an ellipsoid as reference geometry improves the outcome. For generating an even more accurate reference geometry, the exact behavior of the cup during deformation must be understood. Limitations to this method are cups that do not provide pristine areas in order to generate an appropriate best fit geometry. For any figures or tables, please contact authors directly


Bone & Joint Research
Vol. 10, Issue 2 | Pages 137 - 148
1 Feb 2021
Lawrence EA Aggleton J van Loon J Godivier J Harniman R Pei J Nowlan N Hammond C

Aims. Vertebrates have adapted to life on Earth and its constant gravitational field, which exerts load on the body and influences the structure and function of tissues. While the effects of microgravity on muscle and bone homeostasis are well described, with sarcopenia and osteoporosis observed in astronauts returning from space, the effects of shorter exposures to increased gravitational fields are less well characterized. We aimed to test how hypergravity affects early cartilage and skeletal development in a zebrafish model. Methods. We exposed zebrafish to 3 g and 6 g hypergravity from three to five days post-fertilization, when key events in jaw cartilage morphogenesis occur. Following this exposure, we performed immunostaining along with a range of histological stains and transmission electron microscopy (TEM) to examine cartilage morphology and structure, atomic force microscopy (AFM) and nanoindentation experiments to investigate the cartilage material properties, and finite element modelling to map the pattern of strain and stress in the skeletal rudiments. Results. We did not observe changes to larval growth, or morphology of cartilage or muscle. However, we observed altered mechanical properties of jaw cartilages, and in these regions we saw changes to chondrocyte morphology and extracellular matrix (ECM) composition. These areas also correspond to places where strain and stress distribution are predicted to be most different following hypergravity exposure. Conclusion. Our results suggest that altered mechanical loading, through hypergravity exposure, affects chondrocyte maturation and ECM components, ultimately leading to changes to cartilage structure and function. Cite this article: Bone Joint Res 2021;10(2):137–148


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 29 - 29
1 May 2018
Hothi H Eskelinen A Henckel J Blunn G Skinner J Hart A
Full Access

Introduction. Numerous studies have reported on clinically significant volumes of material loss and corrosion at the head-stem junction of metal-on-metal (MOM) hips; less is understood about metal-on-polyethylene (MOP) hips. We compared the effect of bearing type (MOM vs MOP) on taper material loss for a hip system of a single design (DePuy Pinnacle). Methods. We recruited retrieved MOM (n=30) and MOP (n=22) bearing hips that were consecutively received at our centre. We prospectively collected associated clinical and imaging data. We measured the severity of corrosion and volumes of material loss at each head taper surface and used multivariate statistical analysis to investigate differences between the two bearing types. Results. The median rate of material loss for the MOM and MOP groups was 0.81 mm. 3. /year (0.01–3.45) and 0.03 mm. 3. /year (0–1.07) respectively (p<0.001). 29 out of 30 MOM hips were revised for adverse metal reactions, compared with 1 out of 22 MOP hips. Discussion. MOP hips lost significantly less material from their taper junctions than MOM hips. We suggest that the metal-metal interaction at the bearing surface of MOM hips enhances the corrosive environment at the head-stem junction. Conclusion. Our results can reassure patients with MOP Pinnacle hips that they are unlikely to experience clinically significant problems related to material loss from the taper junction


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 265 - 265
1 Jul 2014
Shim V Fernandez J Gamage P Regnery C Hunter P Lloyd D Besier T
Full Access

Summary Statement. Subject specific FE models of human Achilles tendon were developed and optimum material properties were found. Stress concentration occurred at the midsection but dependent on stiffening and thinning of tendon, indicating that they are two major factors for tendon rupture. Introduction. Achilles tendon injuries are common, occurring about 250,000 per year in the US alone, yet the mechanisms of tendinopathy and rupture remain unknown. Most Achilles tendon ruptures occur at 2 to 6 cm above the insertion to the calcaneus bone. Previous angiographic studies have suggested that there is an avascular area in this region. However, it is not understood why that region receives poor blood supply and prone to rupture. The aim of this study is to investigate influence of geometry and material properties on Achilles tendon rupture with mechanical experiment and corresponding subject-specific finite element (FE) analysis. Patients & Methods. Mechanical experiment was performed on 10 fresh human Achilles tendons. High frequency ultrasound images were used to measure cross sectional areas at the midsection of the tendon. Cyclic testing was performed to measure mechanical properties and failure loads. Subject-specific FE models of these tendons were generated with Free Form Deformation (FFD) technique. FE mechanical simulations that mimic the experimental cyclic loading were performed on these subject specific models. Tendon material properties were described as transversely isotropic hyperelastic and the optimum material parameters for the human Achilles tendon were obtained. Linear portion of the cyclic loading data was used as boundary conditions. Measured strains from the experiment were compared with predicted strains from the FE analysis. This process was repeated until optimum parameters were found. The influence of geometry and material properties on the Achilles tendon rupture was then investigated– first with subject-specific geometry with average material properties and then with subject-specific material properties with average geometry. Results. Our results indicate that a significant variation exist in the geometry and material properties in human Achilles tendons. Stress concentrations occurred at the midsection of the tendon, supporting previous studies that reported tendon rupture at the region. In particular the thinning of midsection in geometry is highly correlated with the collagen uncrimpping rate in material properties where thinner midsection leads to faster uncrimpping of collagen fibres. Variations in geometry led to shifts in the location of stress concentration within the midsection while variations in material property led the change in the magnitude of stress concentration. Discussion/Conclusion. Our results indicate that Achilles tendon rupture is highly dependent on subject-specific geometry and material properties. In particular the mid section is the location of stress concentration but depending on the geometrical shape, multiple stress concentrations occur, making the tendon more prone to rupture while the material properties influenced the magnitude of stress concentration. Our results indicate stiffening and thinning of tendon may lead to higher risk for tendon rupture


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 68 - 68
1 Nov 2021
Monahan G Schiavi J Vaughan T
Full Access

Introduction and Objective. Individuals with type 2 diabetes (T2D) have a 3-fold increased risk of bone fracture compared to non-diabetics, with the majority of fractures occurring in the hip, vertebrae and wrists. However, unlike osteoporosis, in T2D, increased bone fragility is generally not accompanied by a reduction in bone mineral density (BMD). This implies that T2D is explained by poorer bone quality, whereby the intrinsic properties of the bone tissue itself are impaired, rather than bone mass. Yet, the mechanics remain unclear. The objective of this study is to (1) assess the fracture mechanics of bone at the structural and tissue level; and (2) investigate for changes in the composition of bone tissue along with measuring total fluorescent advanced glycation end products (fAGEs) from the skin, as T2D progresses with age in Zucker diabetic fatty (ZDF (fa/fa)) and lean Zucker (ZL (fa/+)) rats. Materials and Methods. Right ulnae and skin sections were harvested from ZDF (fa/fa) (T2D) and ZL (fa/+) (Control) rats at 12 and 46 weeks (wks) of age (n = 8, per strain and age) and frozen. Right ulnae were thawed for 12 hrs before micro-CT (μCT) scanning to assess the microstructure and measure BMD. After scanning, ulnae were loaded until failure via three-point bending. Fourier transform-infrared microspectroscopy (FTIR) was used to measure various bone mineral- and collagen-related parameters such as, mineral-to-matrix ratio and nonenzymatic cross-link ratio. Finally, fAGEs were measured from skin sections using fluorescence spectrometry and an absorbance assay, reported in units of ng quinine/ mg collagen. Results. At 12 and 46 wks bone size was significantly smaller in length (p < 0.01), cortical area (p < 0.001) and cross-sectional moment of inertia (p < 0.001) in T2D rats compared to age-matched controls. A slight reduction in BMD was observed in T2D rats compared to controls at both ages, however, this was not significant. Structural properties of T2D bone were significantly altered at 12 and 46 wks, with bending rigidity increasing approximately 2.5-fold and 1.5-fold in control and T2D rats with age, respectively (p < 0.0001). Similarly, yield and ultimate moment significantly reduced in T2D rats with age in comparison to controls (p < 0.0001). Energy absorbed to failure was significantly reduced in T2D rats at 46 weeks of age compared to controls (p < 0.01). The amount of energy absorbed to failure increased approximately 1.4-fold from 12 to 46 wks in control rats, however, in T2D rats a reduction was seen with age, although not significant. At 12 wks, there was no significant deficits in tissue material properties, whereas, at 46 wks a significant reduction in yield stress, yield strain and ultimate stress was observed for T2D rats in comparison to controls (p < 0.05). Conclusions. These findings show that longitudinal growth is impaired as early as 12 wks of age and by 46 wks bone size is significantly reduced in T2D rats compared to controls. The reduction in T2D structural properties is likely attributed to the bone geometry deficits. At 12 wks of age, the tissue material properties are not altered in T2D bone versus controls. However, at 46 wks, bone strength is reduced in T2D, leading to the conclusion that tissue properties are altered as the disease progresses


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 84 - 84
1 Mar 2017
Pianigiani S Vignoni D Innocenti B
Full Access

Introduction. In revision TKA, the management of bone loss depends on location, type, and extent of bony deficiency. Treatment strategies involve cement filling, bone grafting and augments. On the market several solutions are currently available, differing for their shape, thickness and material. While the choice of the shape and the thickness is mainly dictated by the bone defect, no explicit guideline is currently available to describe the best choice of material to be selected for a specific clinical situation. However, the use of different materials could induce different response in term of bone stress and thus changes in implant stability that could worsen long-term implant performance. For these reasons, an investigation about the changes in bone stress in the femur and in the tibia when augments, with different materials and thicknesses was performed. Methods. Different configurations have been separately considered including proximal tibial, distal or/and posterior femoral augments with a thickness of 5, 10 and 15 mm. Apart the control, in which no augments were used, but only the TKA is considered, the augment in all the other configurations were considered made by three different materials: bone cement, to simulate cement filling, tantalum trabecular metal and conventional metal (titanium for the tibia and CoCr for the femoral augments). Each configuration was inserted on a lower leg model including a cruciate-retaining total knee arthroplasty and analyzed by means of finite element analysis applying the max force achieved during walking. The bone stress was investigated in the medial and lateral region of interest close to the augment (with a bone thickness of 10 mm) and in an additional bone region of interest of 50 mm thickness. The bone stress have been compared among the different models and also with respect to the control model. Results. In general, the use of an augment induces a change in bone stress, especially in the region close to the bone cuts. The stiffness of the augment must be as close as possible to the one of the bone. Cement has the best results in terms of bone stress, however, it is only suitable for extremely small defects. Tantalum trabecular metal has results very close to cement and it could be consider a good alternative to cement for any size of defect. Metal (both titanium and CoCr) has the least satisfying results inducing the highest change in bone stress with respect the control. Conclusions. Tibial and femoral bone augments are adopted in case of bone defects that could be present during a revision knee replacement. Several solutions are available on the market in different shapes and materials. However, very few studies are reported to provide possible guidelines. The results of this study demonstrate that material stiffness of the augment must be as close as possible to the one of the bone to achieve the best results


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 71 - 71
1 Feb 2020
Sipek K Gustafson J McCarthy S Hall D Lundberg H Levine B Pourzal R
Full Access

Introduction. Total hip arthroplasty (THA) is a commonly performed procedure to relieve arthritis or traumatic injury. However, implant failure can occur from implant loosening or crevice corrosion as a result of inadequate seating of the femoral head onto the stem during implantation. There is no consensus—either by manufacturers or by the surgical community—on what head/stem assembly procedure should be used to maximize modular junction stability. Furthermore, the role of “off-axis” loads—loads not aligned with the stem taper axis—during assembly may significantly affect modular junction stability, but has not been sufficiently evaluated. Objective. The objective of this study was to measure the three-dimensional (3D) head/stem assembly loads considering material choice—metal or ceramic—and the surgeon experience level. Methods. A total of 29 surgeons of varying levels (Attending, Fellow, Resident) were recruited and asked to perform a benchtop, head/stem assembly using an instrumented apparatus simulating a procedure in the operating room (Figure 1). The apparatus comprised of a 12/14 stem taper attached to a 3D load sensor (9347C, Kistler® USA, Amherst, NY). Surgeons were randomly assigned a metal or ceramic femoral head and instructed to assemble the taper using their preferred surgical technique. This procedure was repeated five times. Surgeons were brought back to test the opposite material after four weeks. Output 3D load data was analyzed for differences in peak vertical load applied, angle of deviation from the stem axis—termed off-axis angle, variability between trials, and impaction location. Results. Preliminary results suggest no significant differences between the loads applied to the metal heads and the ceramic heads. Across the two materials tested, both attendings and residents applied greater loads than fellows (p=0.33; Residents=9.0 kN vs Fellow=7.2 kN: p=0.27; Attendings=8.9 kN vs 7.2 kN) with significantly less variability (Attendings: σ= 1.58; Fellows: σ= 3.26; Residents: σ= 2.86). Attending surgeons also exhibited applied loads at significantly lower off-axis angles compared to fellows (p=0.01; 4.6° vs Fellow=7.2°) (Figure 2). However, all of our clinicians assembled ceramic head tapers with a greater off-axis angle as compared to assembling metal heads. In addition, metal heads were impacted more on-axis for all surgeon experience levels (Figure 3). While the impaction load plots suggest that the first impact strike is the most crucial for head stability, it was determined that the number of strikes is not as important as the maximum impaction load applied. Conclusion. Differences in impaction load when assembling metal and ceramic femoral heads were not apparent; however, variability of technique and load was observed across the different surgical experience levels as well as within surgeons of the same level. Understanding assembly mechanics and surgical habits for THA will provide insight to the best assembly procedures for these implants. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 43 - 43
1 Feb 2020
Knowles N Kusins J Faieghi M Ryan M Dall'Ara E Ferreira L
Full Access

Introduction. Subject-specific finite element models (FEMs) allow for a variety of biomechanical conditions to be tested in a highly repeatable manner. Accuracy of FEMs is improved by mapping density using quantitative computed tomography (QCT) and choosing a constitutive relationship relating density and mechanical properties of bone. Although QCT-derived FEMs have become common practice in contemporary computational studies of whole bones, many density-modulus relationships used at the whole bone level were derived using mechanical loading of small trabecular or cortical bone cores. These cores were mechanically loaded to derive an apparent modulus, which is related to each core's mean apparent or ash density. This study used these relationships and either elemental or nodal material mapping strategies to elucidate optimal methods for scapular QCT-FEMs. Methods. Six cadaveric scapulae (3 male; 3 female; mean age: 68±10 years) were loaded within a micro-CT in a custom CT-compatible hexapod robot Pre- and post-loaded scans were acquired (spatial resolution = 33.5 µm) and DVC was used to quantify experimental full-field displacements (BoneDVC, Insigneo) (Figure 1).. Experimental reaction forces applied to the scapulae were measured using a 6-DOF load cell. FEMs were derived from corresponding QCT scans of each cadaver bone. These models were mapped with one of fifteen density-modulus relationships and elemental or nodal material mapping strategies. DVC-derived BCs were imposed on the QCT-FEMs using local displacement measurements obtained from the DVC algorithm. Comparisons between the empirical and computational models were performed using resultant reaction loads and full-field displacements (Figure 2). Results and Discussion. Reaction forces predicted by the QCT-FEMs showed large percentage error variations across all specimens and density-modulus relationships with elemental material mapping. The percentage errors were as large as 899%, but as low as 3=57% for the different specimens. Similarly, when using a nodal material mapping strategy, percentage errors were as large as 965%, but as low as 4=59% for the different specimens (Figure 3). For all specimens, minimal variation only occurred in the slope between the QCT-FEM and DVC displacements in the x and y directions for either elemental or nodal material mapping strategies. Slopes ranged from 0.86 to 1.06. This held true for 3 specimens in the z direction; however, for the remaining 3 specimens more pronounced variations occurred between the QCT-FEM and DVC displacements, dependent on density-modulus relationship. The r. 2. values were consistently between 0.82 and 1.00 for both material mapping strategies and density-modulus relationships for all three Cartesian components of displacement and all specimens. Conclusions. The results suggest that QCT-FEMs using DVC derived boundary conditions can replicate experimental loading of cadaveric specimens. It was also shown that only slight variations exist when either elemental or nodal material mapping strategies are adopted. Given the recent advancements provided by DVC-derived BCs, this study provides a basis for a common methodology that can be implemented in future studies comparing similar outcomes in all anatomic locations. Expanding the current sample size has the potential to determine if a single density-modulus relationship can exist or if specimen or anatomic location-specific relationships should be utilized. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 392 - 392
1 Jul 2011
Tenzer Y Schwingshackl C Gondhalekar A Davies B Rodriguez y Baena F
Full Access

Surgical long shape tools, such as the arthroscopic hooked probe, are used during knee-arthroscopy procedures by surgeons to manipulate tissues and diagnose problems. These procedures allows surgeons to assess the physical properties of tissues (such as wear, tear, inflammation, stiffness, etc), which are impossible to evaluate using real-time video observation or MRI and CT mapping. This study focuses on the dynamic properties of the hooked probe and its ability to deliver tactile information, created at the tip of the hook as the tissue is being manipulated, to the handle where the surgeon is grasping the instrument. From previous studies, it is known that when a probe comes into contact with hard tissues, such as bones, vibrations can occur that enhance the tactile feedback. To better understand the importance of the dynamic influence on the tactile feedback, initially a vibration analysis of the probe (Model 8399.95 by Richard Wolf UK Ltd) was performed; a stepped sine sweep was carried out to evaluate the dynamic behaviour of the probe, including its resonance response frequencies and the damping behaviour. Several vibration modes were identified in a range up to 2000Hz parallel and perpendicular to the probe. The measurement values were correlated to a finite element model of the probe and an error of less than 5% was found for all relevant resonance response frequencies, thereby validating the accuracy of the model. Measurement and simulation results show that tapping on different materials excites different modes of the probe at different levels, leading to a tactile feedback that harder materials “shift” the probe resonances to higher levels. To verify this, a tapping experiment was performed and the resulting vibrations, while tapping on different materials, were recorded. The study shows that the dynamic behaviour of the probe are somewhat influenced by the fact that the probe is being held in hand leading to a slight reduction in its natural frequencies. A study on an individual’s ability to discriminate between the stiffness of different materials while tapping on them using an arthroscopy hooked probe is currently underway. Ten subjects are being asked to sort five materials (silicon, latex, rubber, plastic, steel) from the softest to the hardest by simple tapping. During the test, each subject is exposed to two materials each time, iteratively until the sort is complete. The subjects are blindfolded and white noise is played through headphones, to blur the sounds of tapping. The resulting dynamic response of the probe is recorded, using an accelerometer, along with the impact forces on the material, measured by a force sensor. Results to date show that subjects can distinguish quite accurately between the soft materials (silicon and latex), but find it difficult to distinguish between stiffer materials (plastic and steel), but comprehensive statistics are not yet available