Introduction. Emergency department (ED) visits following primary total knee arthroplasty (TKA) can lead to poor patient satisfaction, potentially unnecessary readmissions, and greater overall healthcare costs. Reasons for post-operative ED visits are often entirely medical in nature and can be independent of the recent operation. Several strategies have been developed to help reduce ED visits. However, one major factor that can play a critical role in addressing potentially avoidable visits is provider and patient education. A major factor that can play a crucial role in addressing potentially avoidable visits is provider and patient education. It follows that a thorough understanding of which patients are visiting the ED and why can help in avoiding the visits. Therefore, the purpose of this study was to investigate: 1) causes and 2) patient-related factors (demographics and comorbidities) associated with ED visits following primary TKA. Methods. A national private payer database was queried for primary TKAs performed between 2007 and 2016 using the International Classification of Disease, ninth revision (ICD-9) procedural code 81.54. ED visits were identified using Current Procedural Terminology (CPT) codes 99281 to 99285. Patients with 90-day ED visits were in the study group (n=28,044) whereas those without 90-day ED visits served as controls (n=82,289). Causes for ED visits were divided into cardiopulmonary, gastrointestinal, renal, thromboembolic,
The restoration of knee alignment is an important
goal during total knee arthroplasty (TKA). In the past surgeons aimed
to restore neutral limb alignment during surgery. However, previous
studies have demonstrated alignment to be dynamic, varying depending
on the position of the limb and the degree of weight-bearing, and
between patients. We used a validated computer navigation system
to measure the femorotibial mechanical angle (FTMA) in 264 knees in
77 male and 55 female healthy volunteers aged 18 to 35 years (mean
26.2). We found the mean supine alignment to be a varus angle of
1.2° (standard deviation ( Knee alignment is different in different individuals and is dynamic
in nature, changing with different postures. This may have implications
for the assessment of alignment in TKA, which is achieved in non-weight-bearing conditions
and which may not represent the situation observed during weight-bearing. Cite this article:
We performed a randomised, controlled trial involving 150 patients with a pre-operative level of haemoglobin of 13.0 g/dl or less, to compare the effect of either topical fibrin spray or intravenous tranexamic acid on blood loss after total knee replacement. A total of 50 patients in the topical fibrin spray group had 10 ml of the reconstituted product applied intra-operatively to the operation site. The 50 patients in the tranexamic acid group received 500 mg of tranexamic acid intravenously five minutes before deflation of the tourniquet and a repeat dose three hours later, and a control group of 50 patients received no pharmacological intervention. There was a significant reduction in the total calculated blood loss for those in the topical fibrin spray group (p = 0.016) and tranexamic acid group (p = 0.041) compared with the control group, with mean losses of 1190 ml (708 to 2067), 1225 ml (580 to 2027), and 1415 ml (801 to 2319), respectively. The reduction in blood loss in the topical fibrin spray group was not significantly different from that achieved in the tranexamic acid group (p = 0.72).