Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 12 - 12
17 Apr 2023
Van Oevelen A Burssens A Krähenbühl N Barg A Audenaert E Hintermann B Victor J
Full Access

Several emerging reports suggest an important involvement of the hindfoot alignment in the outcome of knee osteotomy. At present, studies lack a comprehensive overview. Therefore, we aimed to systematically review all biomechanical and clinical studies investigating the role of the hindfoot alignment in the setting of osteotomies around the knee. A systematic literature search was conducted on multiple databases combining “knee osteotomy” and “hindfoot/ankle alignment” search terms. Articles were screened and included according to the PRISMA guidelines. A quality assessment was conducted using the Quality Appraisal for Cadaveric Studies (QUACS) - and modified methodologic index for non-randomized studies (MINORS) scales. Three cadaveric, fourteen retrospective cohort and two case-control studies were eligible for review. Biomechanical hindfoot characteristics were positively affected (n=4), except in rigid subtalar joint (n=1) or talar tilt (n=1) deformity. Patient symptoms and/or radiographic alignment at the level of the hindfoot did also improve after knee osteotomy (n=13), except in case of a small pre-operative lateral distal tibia- and hip knee ankle (HKA) angulation or in case of a large HKA correction (>14.5°). Additionally, a pre-existent hindfoot deformity (>15.9°) was associated with undercorrection of lower limb alignment following knee osteotomy. The mean QUACS score was 61.3% (range: 46–69%) and mean MINORS score was 9.2 out of 16 (range 6–12) for non-comparative and 16.5 out of 24 (range 15–18) for comparative studies. Osteotomies performed to correct knee deformity have also an impact on biomechanical and clinical outcomes of the hindfoot. In general, these are reported to be beneficial, but several parameters were identified that are associated with newly onset – or deterioration of hindfoot symptoms following knee osteotomy. Further prospective studies are warranted to assess how diagnostic and therapeutic algorithms based on the identified criteria could be implemented to optimize the overall outcome of knee osteotomy. Remark: Aline Van Oevelen and Arne Burssens contributed equally to this work


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 57 - 57
1 Dec 2020
Ateş YB Çullu E Çobanoğlu M
Full Access

Aim. To investigate the effect of the eight plate position in sagittal plane on tibial slope in temporary epiphysiodesis technique applied to the proximal tibia and whether there is a rebound effect after removing the plate. Method. Forty New Zealand rabbits (6 weeks old) were divided into four groups. In all groups, two 1.3 mm mini plates and cortical screws implantation were placed on both medial and lateral side of the proximal epiphysis of the right tibia. In Group 1 and 3, the plates were placed on anterior of the proximal tibial anatomical axis in the sagittal plane, and placed posteriorly in Group 2 and 4. The left tibia was examined as control in all groups. Group 1 and Group 2 were sacrificed after four week-follow-up. In Group 3 and Group 4, the implants were removed four weeks after index surgery and the rabbits were followed four more weeks to investigate the rebound effect. The tibial slope was measured on lateral X-rays every two weeks. Both medial and lateral plateau slopes were evaluated on photos of the dissected tibia. Results. In Group 1, right MTPA (medial tibial plateau angle) and left MTPA, right LTPA (lateral tibial plateau angle) and left LTPA, and right 4wTPPA (the tibial proximal posterior angle at 4th week) and left 4wTPPA values were compared with each other. There was a significant difference in MTPA, LTPA, and 4wTPPA in Group 1 (p: 0.003, 0.006, 0.004). In Group 1, the medial and lateral slope significantly decreased after 4 weeks. There was no significant difference in MTPA, LTP and 4wTPPA measurements in Group 2 (p= 0.719, 0.306, 0.446, respectively). In Group 2, the slope did not change in four weeks. There was a significant difference in MTPA, LTPA, 4wTPPA, and 8wTPPA (tibial proximal posterior angle at 8th week) in Group 3 (p= 0.005, 0.002, <0.001, <0.001, respectively). In Group 3, the slope decreased at 4th week and remained stabile during the next four week-follow up and no rebound effect was observed. There was no significant difference in MTPA, LTPA, 4wTPPA, and 8wTPPA measurements in Group 4 (p= 0.791, 0.116, 0.232, 0.924), respectively. In group 4, slope did not change at 4th week of index surgery and no rebound effect was observed in the next four week-follow up. Conclusion. If eight plates were placed on anterior of lateral proximal tibia axis on both medial and lateral side, the tibial slope would reduce, and remain stabile after implant removal. Care should be taken to place the plates on the line of proximal tibial axis in sagittal plane in temporary epiphysiodesis technique performed due to angular knee deformities. Changing the slope due to plate placement can be used as a secondary gain for patients who will benefit from slope change, such as adolescent ACL surgery


Bone & Joint Research
Vol. 2, Issue 6 | Pages 102 - 111
1 Jun 2013
Patel RA Wilson RF Patel PA Palmer RM

Objectives

To review the systemic impact of smoking on bone healing as evidenced within the orthopaedic literature.

Methods

A protocol was established and studies were sourced from five electronic databases. Screening, data abstraction and quality assessment was conducted by two review authors. Prospective and retrospective clinical studies were included. The primary outcome measures were based on clinical and/or radiological indicators of bone healing. This review specifically focused on non-spinal orthopaedic studies.