Advertisement for orthosearch.org.uk
Results 1 - 20 of 273
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 11 - 11
1 Apr 2019
Wong M Desai B Bautista M Kwon O Chimento G
Full Access

PURPOSE. YouTube is a video sharing platform that is a common resource for patients seeking medical information. The objective of this study is to assess the educational quality of YouTube videos pertaining to total knee arthroplasty and knee arthritis. METHODS. A systematic search for the terms “knee replacement” and “knee arthritis” was performed using Youtube's search function. Data from the 60 most relevant videos were collected for each search term. Videos not in English or those without audio or captions were excluded. Quality assessment checklists with a scale of 0 to 10 points were developed to evaluate the video content. Videos were grouped into poor quality (grade 0–3), acceptable quality (grade 4–7) and excellent quality (grade 8– 10), respectively. Four independent reviewers assessed the videos using the same grading system and independently scored all videos. Discrepancies regarding the scoring were clarified by consensus discussion. RESULTS. Overall 106 videos were categorized. For videos regarding total knee replacements, the average number of views was 135,074 with an average duration of 14.53 minutes. Half of the videos were published by a physician or hospital sponsor and were for educational purposes. 64% of videos were of poor educational quality (32/50), 28% were of acceptable quality (14/50), and 8% were of good educational quality (4/50). Common missing information included discussion of surgical complications and implant duration. For videos regarding knee arthritis, the average number of views was 243,346 with an average duration of 4.97 minutes. 39% were published by a physician or hospital sponsor, with 64% of videos made for educational purposes. 66% of videos were of poor educational quality (37/56), 32% were of acceptable quality (18/56), and 2% were of good educational quality. The most common missing information were causes and risk factors for knee arthritis and long-term prognosis. CONCLUSIONS. The present study suggests that YouTube is a poor educational source for patients regarding knee arthroplasty and knee arthritis. Recognizing the limitations of YouTube as well as which topics are not commonly presented may guide clinicians to better educate their patients


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 63 - 63
1 Nov 2021
Visscher L White J Tetsworth K McCarthy C
Full Access

Introduction and Objective. Malunion after trauma can lead to coronal plane malalignment in the lower limb. The mechanical hypothesis suggests that this alters the load distribution in the knee joint and that that this increased load may predispose to compartmental arthritis. This is generally accepted in the orthopaedic community and serves as the basis guiding deformity correction after malunion as well as congenital or insidious onset malalignment. Much of the literature surrounding the contribution of lower limb alignment to arthritis comes from cohort studies of incident osteoarthritis. There has been a causation dilemma perpetuated in a number of studies - suggesting malalignment does not contribute to, but is instead a consequence of, compartmental arthritis. In this investigation the relationship between compartmental (medial or lateral) arthritis and coronal plane malalignment (varus or valgus) in patients with post traumatic unilateral limb deformity was examined. This represents a specific niche cohort of patients in which worsened compartmental knee arthritis after extra-articular injury must rationally be attributed to malalignment. Materials and Methods. The picture archiving system was searched to identify all 1160 long leg x ray films available at a major metropolitan trauma center over a 12-year period. Images were screened for inclusion and exclusion criteria, namely patients >10 years after traumatic long bone fracture without contralateral injury or arthroplasty to give 39 cases. Alignment was measured according to established surgical standards on long leg films by 3 independent reviewers, and arthritis scores Osteoarthritis Research Society International (OARSI) and Kellegren-Lawrence (KL) were recorded independently for each compartment of both knees. Malalignment was defined conservatively as mechanical axis deviation outside of 0–20 mm medial from centre of the knee, to give 27 patients. Comparison of mean compartmental arthritis score was performed for patients with varus and valgus malalignment, using Analysis of Variance and linear regression. Results. In knees with varus malalignment there was a greater mean arthritis score in the medial compartment compared to the contralateral knee, with OARSI scores 5.69 vs 3.86 (0.32, 3.35 95% CI; p<0.05) and KL 2.92 vs 1.92 (0.38, 1.62; p<0.005). There was a similar trend in valgus knees for the lateral compartment OARSI 2.98 vs 1.84 (CI −0.16, 2.42; p=0.1) and KL 1.76 vs 1.31 (CI −0.12, 1.01; p=0.17), but the evidence was not conclusive. OARSI arthritis score was significantly associated with absolute MAD (0.7/10mm MAD, p<0.0005) and Time (0.6/decade, p=0.01) in a linear regression model. Conclusions. Malalignment in the coronal plane is correlated with worsened arthritis scores in the medial compartment for varus deformity and may similarly result in worsened lateral compartment arthritis in valgus knees. These findings support the mechanical hypothesis that arthritis may be related to altered stress distribution at the knee, larger studies may provide further conclusive evidence


Bone & Joint Open
Vol. 1, Issue 7 | Pages 339 - 345
3 Jul 2020
MacDessi SJ Griffiths-Jones W Harris IA Bellemans J Chen DB

Aims. An algorithm to determine the constitutional alignment of the lower limb once arthritic deformity has occurred would be of value when undertaking kinematically aligned total knee arthroplasty (TKA). The purpose of this study was to determine if the arithmetic hip-knee-ankle angle (aHKA) algorithm could estimate the constitutional alignment of the lower limb following development of significant arthritis. Methods. A matched-pairs radiological study was undertaken comparing the aHKA of an osteoarthritic knee (aHKA-OA) with the mechanical HKA of the contralateral normal knee (mHKA-N). Patients with Grade 3 or 4 Kellgren-Lawrence tibiofemoral osteoarthritis in an arthritic knee undergoing TKA and Grade 0 or 1 osteoarthritis in the contralateral normal knee were included. The aHKA algorithm subtracts the lateral distal femoral angle (LDFA) from the medial proximal tibial angle (MPTA) measured on standing long leg radiographs. The primary outcome was the mean of the paired differences in the aHKA-OA and mHKA-N. Secondary outcomes included comparison of sex-based differences and capacity of the aHKA to determine the constitutional alignment based on degree of deformity. Results. A total of 51 radiographs met the inclusion criteria. There was no significant difference between aHKA-OA and mHKA-N, with a mean angular difference of −0.4° (95% SE −0.8° to 0.1°; p = 0.16). There was no significant sex-based difference when comparing aHKA-OA and mHKA-N (mean difference 0.8°; p = 0.11). Knees with deformities of more than 8° had a greater mean difference between aHKA-OA and mHKA-N (1.3°) than those with lesser deformities (-0.1°; p = 0.009). Conclusion. This study supports the arithmetic HKA algorithm for prediction of the constitutional alignment once arthritis has developed. The algorithm has similar accuracy between sexes and greater accuracy with lesser degrees of deformity. Cite this article: Bone Joint Open 2020;1-7:339–345


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 62 - 62
1 Oct 2012
Deep K Menna C Picard F
Full Access

The aim of the study was to investigate rotational behaviour of the arthritic knee before (preimplant) and after (postimplant) total knee replacement (TKR) using (image-free navigation system as a measurement tool which recorded the axial plane alignment between femur and tibia, in addition to the coronal and sagittal alignment as the knee is flexed through the range of motion. The data on the rotation of the arthritic knee was collected after the knee exposure and registration of the lower limb (preimplant data). The position of rotation between the femur and tibia was recorded in 30° flexion, 45°, 60°, 90° and maximum degrees of flexion of the knee. The data was divided into subsets of varus and valgus knees and these were analysed pre and postimplant for their rotational position using SPSS for statistics. The system was used in 117 knees of which 91 had full data set available (43 male 48 female). These included 71 varus knees, 16 valgus knees and 4 neutral knees to start in extension. Preimplant data analysis revealed there is tendency for the arthritic knees to first go in internal rotation in the initial part of flexion to 30 degrees and then the rotation is reversed back. This happens irrespective of the initial starting rotational relationship between femur and tibia in full extension. This happens in both varus as well as valgus arthritic knees. This trend of internal rotation in this initial part of flexion is followed in TKR as well implanted with fixed bearing CR knees irrespective of the preoperative deformity. Also noteworthy was the difference in rotation at 30°, 60° and 90 degrees of flexion between preimplant and postimplant knees (irrespective of varus and valgus groups). When calculated at different points of flexion, there was statistically significant difference in the change of rotation at each point of flexion except 45 degree of flexion. The pre-operative values of change in rotation (internal being positive) at each step from the extended position being 5.4° (SD 4.5°) at 30 ° flexion, 4.7°(5.2°) at 45°, 3.6°(6.1°) at 60°, 3.5°(7.2°) at 90° and 4.2°(8.3°) at maximum flexion. Corresponding post-operative rotations were 2.2°(4.8°), 4.1°(6.4°), 6.6°(7.3°), 9.9°(8.8°) and 7.7°(8.9°). There was also an increase in the total range of rotation that the knee goes through after it has been implanted with prosthesis although it may not happen in every knee. This is statistically significant (p value <0.001) and seems more so in valgus group. The rotational movements and interrelationship of the femur and tibia is a complex issue, especially in the arthritic knees. Preimplant arthritic knee behaved generally similarly to normal knees according to the literature. Normal gait pattern demonstrates that the tibia moved through a 4° to 8° arc of internal rotation relative to the femur. The overall range (10.2° =/−4.2°) of knee rotation in this study greater than 8° might be explained by preimplant data acquired after the knee was approached and therefore releasing knee soft tissue envelop. This study confirmed that during the first 30° both varus and valgus knees moved internally. In our study there is increased range of total rotation postimplant (14° =/−6.8°) which may be explained by the fact that the anterior cruciate ligament is lost in all the TKRs and the posterior cruciate ligament may be dysfunctional as well. Thus the constraints on the knee rotation are decreased postimplant leading to increased rotation. We found some difference between varus and valgus post implant knees in that internal rotation seen in initial 30 degrees of flexion is much more pronounced in valgus knees as compared to varus knees (p value <0.001). This study confirmed knee internal rotation in initial stages of flexion, preimplant in arthritic knees during a passive knee flexion assessment. Varus and valgus knee seemed to behave similarly. This mimics the normal knee rotation. Postimplant knees in TKR behave differently


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims. This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults. Methods. This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded. Results. Nearly half of the fractures were Schatzker II AO B3.1 fractures (n = 85; 47%). Radiological knee OA was present at fracture in 59/182 TPFs (32.6%). Primary management was fixation in 174 (95.6%) and acute TKA in eight (4.4%). A total of 13 patients underwent late TKA (7.5%), most often within two years. By five years, 21/182 12% (95% confidence interval (CI) 6.0 to 16.7) had required TKA. Larger volume defects of greater depth on CT (median 15.9 mm vs 9.4 mm; p < 0.001) were significantly associated with TKA requirement. CT-measured joint depression of > 12.8 mm was associated with TKA requirement (area under the curve (AUC) 0.766; p = 0.001). Severe joint depression of > 15.5 mm (hazard ratio (HR) 6.15 (95% CI 2.60 to 14.55); p < 0.001) and pre-existing knee OA (HR 2.70 (95% CI 1.14 to 6.37); p = 0.024) were independently associated with TKA requirement. Where patients with severe joint depression of > 15.5 mm were managed with fixation, 11/25 ultimately required TKA. Conclusion. Overall, 12% of patients aged ≥ 60 years underwent TKA within five years of TPF. Severe joint depression and pre-existing knee arthritis were independent risk factors for both post-traumatic OA and TKA. These features should be investigated as potential indications for acute TKA in older adults with TPFs. Cite this article: Bone Joint J 2024;106-B(1):28–37


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 400 - 400
1 Sep 2009
Confalonieri N Manzotti A Motavalli K
Full Access

The Authors performed a matched paired study between 2 groups UKR or CA-TKR implanted with a mini-incision (MICA group) in the treatment of isolated medial compartment knee arthritis. The Authors hypothesized that UKR offers a real less invasive surgery with lower economical costs despite a worse limb/implant alignment. Furthermore at a minimum 40 months follow-up they hypothesized that this small implant guarantees still both better clinical score and patient satisfaction than in the MICA group. Thirty two patients with isolated medial compartment knee arthritis who underwent to a medial UKR from February 2001 to September 2002 were included in the study (UKR group). In all 32 knees the arthritic change was graded according to the classification of Älback . 1. Arthritic change did not exceed grade IV in the medial compartment and grade II in the patello-femoral compartment. All patients had an asymptomatic patello-femoral joint. All patients had a varus deformity lower than 8° and a body mass index lower than 30. No patient had any clinical evidence of ACL laxity or flexion deformity and all had a preoperative range of motion of a least 110°. At a minimum follow-up of 48 months, every single patients in group A was matched with a patient who had undergone a computer assisted TKR performed with a less invasive approach (shorter than 12 cm) for an isolated medial compartment knee arthritis between August 1999 and September 2002 (MICA group) in our hospital. At latest follow-up the clinical outcome was evaluated using both the Knee Society Score and a dedicated UKR score developed by the Italian Orthopaedic UKR Users Group (GIUM). The HKA angle and the Frontal Tibial Component angle (FTC) were measured at latest follow up on long leg standing anterior-posterior radiographs and the mean values between the 2 surgeons assessments were used as final values. Furthermore during the hospital staying we registered in both the groups when each patient was standing comfortably in full weight-bearing according to a self- answered questionnaire and the data were compared. Statistical analysis of the results was performed using parametric test (Student’s t-test). A statistical comparison of the percentage of results for the GIUM score was performed using the Chi-square test. A statistically significant result was given a p≤ 0.05. Both hospital stay and operative time were statistically longer obviously in MICA group. In the UKR group the mean surgical time was 51.5 minutes (range: 36–75) (p< 0.001) while in the MICA group was 108.8 minutes (range: 80–132) (p< 0.001). In the UKR group the patients remained in the hospital for a mean of 5.1 days (range: 3–7) and in the MICA group 8.2 days (range: 4–16). At the latest follow-up the mean Knee Society Score was 80.5 (range: 70–100) and 78.4 (range: 70–87) for group A and B respectively. No statistically significant difference was seen for the Knee Society score between the 2 groups (p=0.08). The mean Functional score was 83.5 (range: 73–100) for group A and 78.8 (range: 59–90) for group B. A statistically significant difference was seen for the Functional score with superior results for group A (p=0.02). A statistically significant difference was seen for the GIUM score with better results for group A (p=0.01). The mean GIUM score was 76 (range: 67–90) and 73.02 (mean: 65–85) for group A and B respectively. At latest follow up the mean HKA angle was 176.8° for group A (range: 174°–182°) and 179.3° for group B (range 177–182) (p< 0.001). The mean FTC angle was 86.9° (range: 84°–90°) and 89.4° (range: 87°–92°) for group A and B respectively (p< 0.001). All TKR implants were positioned within 4 degrees of a HKA angle of 180° and FTC angle of 90°. At the latest follow-up (minimum 48 months) no statistically significant difference was seen in the postoperative Knee Society score for either group. However, significant differences were seen between the 2 groups in the functional results and in the GIUM score with better results in the UKR group. All the patients achieved a range of motion greater than 120° and could walk for longer distances. During the hospital staying in this group the patients reported a statistically significant earlier full weight-bearing. This was despite a significant less accurate limb alignment. In addition to inferior results for the computer assisted mini-invasive TKR group the costs of the procedure were obviously greater because of the expensive implants and technology along with statistically significant longer surgical times and hospital stay


Introduction. Septic knee arthritis with severe osteoarthritis (OA) presents challenging clinical situations because of unexpected and long time for treatment and less satisfactory clinical outcomes. Septic arthritis with damage to articular cartilage developed osteomyelitis (OM) frequently. Although arthroscopic debridement was the common treatment of septic arthritis, there was some limitation on the management of infected bone structures and then open arthrotomy should be reserved. In the patients of OM located only periarticular areas, the author used the PROSTALAC system for infected total knee arthroplasty (TKA) and achieved good results. Objectives. In periarticular OM with septic knee arthritis in patients with severe OA, we report the rate of control of infection using the PROSTALAC articulating spacer and to assess the clinical outcome after staged TKA. Methods. This study was conducted on a total of 11 patients (11 knees) treated for septic knee arthritis in patients with Kellgren-Lawrence classification grade 3–4 OA between April, 2014 and April, 2015. Of these, we retrospectively reviewed 6 knees of 6 patients (54.5%) who underwent staged TKA using the PROSTALAC articulating spacer. The inclusion criteria were periarticular OM confirmed by magnetic resonance imaging (MRI) and whole body bone scan (WBBS), affected bone could be resected and covered by the PROSTALAC system. There were 2 males and 4 females with a mean age of 64 years (range, 61 to 68 years). Prior to the initial surgery, the average erythrocyte sedimentation rate (ESR) 87mm/h, and C-reactive protein (CRP) 8.8 mg/dl. The mean follow-up period was 14 months (range, 12 to 24 months). For clinical assessment, WOMAC, UCLA, Patient Satisfaction scores and postoperative complications were evaluated. For radiological assessment, weight-bearing radiographs of the knee were obtained to evaluate bone change, component loosening, and recurrence of infection. Results. The mean interval between initial operation using the PROSTALAC system and staged TKA was 8.2 weeks (range, 8–10 weeks). The species could be identified in the culture of aspiration of joint fluid prior to the initial operation. The most frequently found etiologic agent was gram-positive cocci (66.6%), followed by MRSA (16.7%) and yeast like fungi (16.7%). At last review, ESR and CRP returned to normal and follow-up cultures were negative in all patients. We observed improvements in mean WOMAC, UCLA, and Patient Satisfaction scores at last review. Radiographs at final follow-up showed well-fixed implants with no radiographic evidence of loosening or infection. Conclusions. In this study, we observed a 100% microbiologic cure and 89% clinical cure in patients who underwent a staged TKA using the PROSTALAC system with a 14-months follow-up. This method appears to have several important advantages (1) there is less possibility of additional bone resection due to uncontrolled infection of adjacent bone; (2) there are possibly expected interval between two stages and more good patient satisfaction. The staged TKA using the PROSTALAC spacer would have a predictable, favorable effect on the control of infection and improvements in the functional outcomes for the treatment periarticular OM with septic knee arthritis in patients with severe arthritis


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 363 - 363
1 Nov 2002
Synder M Marciniak M Drobniewski M
Full Access

Introduction: The knee arthritis is a very common seen chronic disease in an orthopaedic practice. It is mostly seen in patients after 6 decade of life and connected with a severe knee pain. In most of the cases the surgical intervention is indicated because of unicondylar arthritis changes. Because of the costs of the hemiarthroplasty we choose a high tibial osteotomy for tibial axis correction to prevent further gonarthrosis. The aim of this study was to evaluate the late results after high tibial osteotomy in patients with unicondylar gonarthrosis. Material and Methods: In our Institution during last 20 years 94 high tibial osteotomy were performed because of unicondylar, medial gonarthrosis. The mean age of the patient at the time of surgery was 56 years (from 19 to 72 years). The mean follow-up was 16 years. Only patients with arthritic changes on the medial compartment of the knee with a “good” lateral part of the knee were scheduled for this type of surgery. In every case the dome type of osteotomy was performed followed by 1cm resection of fibula. After surgery the limb was stabilized with plate in 16 cases, K-wires in 4 cases, Ilizarov frame in 43 cases, orthofix device in 8 cases and other type of external fixator in remaining 23 cases. In patients where external fixator was used the full weight bearing was recommended as soon as patient tolerated the pain. The external fixator was removed after an average period of 6 weeks when bone callus was diagnosed. To assess of the clinical results based on HSS score and radiological results were evaluated using the modified Dihlmann classification. Results: In 88,8% of all cases the final result was graded as excellent and good, in 1,9% the final results was satisfactory and in 7.8% the final results was poor. From analyzed patients 46% was scheduled for TKR at an average time of 12 years after initial surgical procedure. In 28% after average 16 years after high tibial osteotomy the good shape of the knee joint was observed with good clinical function and radiographic appearance. Pain was reduced in 82% of all cases, increased range of the knee motion was observed in 65% and improved walking ability in 64% of all cases. The poor results were connected with not adequate patients selection for this type of surgery (patients after 7 decade of life) and with advanced arthritic knee changes before the surgery. Conclusions : The high tibial osteotomy is a good method for preventing gonarthrosis. When early performed gives good long-lasting result. In our opinion is recommended for unicondylar gonarthrosis as an alternative to the knee hemiarthroplasty


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 31 - 31
1 Dec 2018
Bonnet E Limozin R Giordano G Fourcade C
Full Access

Aim. The aim of our study was to identify pathogens involved in septic knee arthritis after ACLR and to describe clinical features, treatment and outcome of infected patients. Methods. We conducted a retrospective observational study including all patients with ACLR infection in 3 orthopedic centers sharing the same infectious disease specialists. Results. During a seven-year period (2011–2017) we identified 74 infected patients among 9858 patients who had ACLR (incidence rate = 0.0075). Fourteen patients had polymicrobial infection. We identified 89 pathogens. Twenty four patients (34.4 %) were infected with S. aureus (27% of all isolates)(only one oxacillin-resistant strain). C. acnes was the second most frequent pathogen, identified in 14 patients (18.9%) (15.7% of all isolates). S. lugdunensis was identified in 9 patients (12.2%) (10.1% of all isolates). S. caprae was as frequent as S. epidermidis identified in 8 patients each (10.8%) (9 % of all isolates for each). No strain of S. lugdunensis and S. caprae was resistant to oxacillin, levofloxacin or rifampicin. Ten patients infected by C. acnes, 8 infected by S. lugdunensis, and 7 infected by S. caprae had an early acute infection. In all cases but one an arthroscopic lavage was performed, in 14 cases two lavages were required and in 4, 3 lavages. All patients infected by a strain susceptible to levofloxacin and rifampicin, including those with C. acnes, S. caprae and S. lugdunensis infection, were treated with an oral combination of levofloxacin and rifampicin, after a couple of days of IV empirical treatment with vancomycin and a broad spectrum beta-lactam. The median duration of treatment was 6 weeks. Seventy one patients were considered cured. Conclusions. To our knowledge this is the largest reported series of infection after ACLR. S. aureus is the main pathogen (27% of all strains). C. acnes, S. lugdunensis and S. caprae accounted for almost 35% of pathogens and 38% of infections. A conservative strategy consisting in arthroscopic lavage(s) and a 6-week treatment with levofloxacin and rifampicin was effective


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 81 - 81
1 Jan 2016
Narita A Asano T Suzuki A Takagi M
Full Access

Background. Septic knee arthritis is one of the most serious complications after total knee arthroplasty (TKA), and the effectiveness of its treatment affects the patient's quality of life. In our super-aging society, the frequency of TKA in the elderly, often combined with various comorbidities, is increasing. Careful management should be considerd during the management of septic arthritis after TKA in these patients. Purpose. To analyze the clinical features and outcomes of septic arthritis after TKA in our institution. Materials and Methods. Between April 1999 and March 2014, 534 TKAs (osteoarthritis [OA]; 381, rheumatoid arthritis [RA]; 154) were performed. Of these patients, 8 with post-operative infected TKA were retrospectively surveyed. Results. The TKA-associated infection rates were 0.83% (0.35%, OA; 1.7%, RA) during the study period. Five male and 3 female patients were included, with a mean age of 68 years (range, 39–88 years) and primary diagnoses of OA (5) and RA (3). Malignant rheumatoid arthritis (MRA) was present in 1 patient. The infection was affected by a comorbidity in 2 (diabetes mellitus and mixed connective tissue disease). Microorganisms were detectable in 7 patients (methicillin-resistant Staphylococcus aureus [MRSA], 1; methicillin-sensitive Staphylococcus aureus, 2; Streptococcus pyogens, 1; Streptococcus oralis, 1; Escherichia coli, 1; Staphylococcus epidermidis, 1; and unknown, 1) (Fig. 1). The use of the Segawa/Leone classification resulted in 5 patients with type III (acute hematogenous) and 3 with type IV (late) infections. Four patients with type III (80%) infection underwent open debridement, continuous irrigation, and successful implant retention (Fig. 2). The MRA patient had type III infection and an MRSA infection that was treated with two-stage revision, but the infection recurred. We could not perform a re-implantation, and resection arthroplasty was needed. Arthroscopic irrigation in 1 patient with type III infection ended in failure, and open debridement was required. We attempted to retain the implant in 1 patient with type IV infection, but implant removal was required. Three patients with type IV infection underwent two-stage revision successfully. Discussion. The post-TKA infection rate was 0.83% in our institution. Of the implants, 50% (type III, 80%; type IV, 0%) were successfully retained. Early open debridement and irrigation are important for implant retention in patients with infected TKAs, while arthroscopic debridement does not appear to be effective for infected TKA. Implant retention was difficult in the presence of resistant microorganisms. Two-stage revision was required in patients with type IV infection, with a success rate of 75%


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 663 - 666
1 Jul 1999
Sawant MR Bendall SP Kavanagh TG Citron ND

In two years we treated four women with ununited stress fractures of their proximal tibial diaphyses. They all had arthritis and valgus deformity. The stress fractures had been treated elsewhere by non-operative means in three patients and by open reduction and internal fixation in one, but had failed to unite. After treatment with a modular total knee prosthesis with a long tibial stem extension, all the fractures united. A modular total knee prosthesis is suitable for the rare and difficult problem of ununited tibial stress fractures in patients with deformed arthritic knees since it corrects the deformity and the adverse biomechanics at the fracture site, stabilises the fracture and treats the arthritis


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 424 - 424
1 Sep 2009
Indluru R Khanna A Kumar A
Full Access

Aim: To evaluate results of fully congruent Mobile bearing knee arthroplasty for valgus arthritic knees using lateral capsular approach and realignment of vastus lateralis. Material and Method: We reviewed results of 50 mobile bearing total knee arthroplasties performed consecutively between 2001 and 2006 for Valgus arthritic knees, using lateral capsular approach and realignment of vastus lateralis. Patients were evaluated using oxford and International knee society Score. Radiographs were examined for alignment of the component, evidence of loosening and scanograms assessed to evaluate the restoration of mechanical axis. Results: The study group consisted of 47 patients, 20 men and 27 women who received fifty knees. The mean age at the primary operation was 71.57 years (range 47–82 years; SD, 9.5). The mean follow up was 4.2 years (range 1–6 years; SD, 1.35). The mean Valgus deformity was 15.92° (rang from 15–20 SD 1.89). Fixed flexion deformity was seen in 15 knees. The mean Oxford Knee Society ratings was 52 (range 47–55; SD, 3.18) preoperatively, and 19 (range 14–24; SD, 3.72) at final follow up. The pre op mean range motion was 84.28° (range 45°–120°; SD 21.73). At final follow up the average range of motion was 107.5° (range 95°–120°; SD 8.93). According to the system of the Knee Society, the average knee score was 94 points and the average functional score was 89 points at final follow up. There were no clinical failures or cases of postoperative instability and no cases of radiographic loosening or wear. Radiological evaluation: None of these knees had radiographic evidence of loosening or osteolysis. Mechanical axis was restored in all the patients. Conclusion: This study demonstrates satisfactory results of Mobile bearing knee arthroplasty using lateral parapatellar with proximal realignment of vastus lateralis for Valgus arthritic knees


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 168 - 168
1 Jun 2012
Nasser E Tarabichi S
Full Access

We hypothesize that tethering adhesions of the quadriceps muscle are the major pathological structures responsible for a limited range of motion in the stiff arthritic knee. Forty-two modified quadriceps muscle releases were performed on 24 patients with advanced osteoarthritis scheduled for total knee arthroplasty. The ranges of motion were documented intraoperatively both before and immediately after the release. Passive flexion improved significantly in all patients (mean, 32.4 degrees of improvement, P < .001) following a modified quadriceps release, despite any presence of osteophytes or severe deformities. These results strongly implicate adhesions of the quadriceps muscle to the underlying femur, which prevent the distal excursion of the quadriceps tendon, as the restrictive pathology preventing deep flexion in patients with osteoarthritis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_16 | Pages 4 - 4
1 Oct 2017
Miller A Abdullah A Hague C Hodgson P Blain E
Full Access

The lifetime prevalence of symptomatic osteoarthritis at the knee is 50% osteoarthritis of the ankle occurs in only 1% of the population. This variation in prevalence has been hypothesised to result from the differential responsiveness of the joint cartilages to catabolic stimuli. Human cartilage explants were taken from the talar domes (n=12) and the femoral condyles (n=7) following surgical amputation. Explants were cultured in the presence of either a combination of high concentration cytokines (TNFα, OSM, IL-1α) to resemble a post traumatic environment or low concentration cytokines to resemble a chronic osteoarthritic joint. Cartilage breakdown was measured by the percentage loss of Sulphated glycosaminoglycan (sGAG) from the explant to the media during culture. Expression levels of the pro-inflammatory molecules nitric oxide and prostaglandin E. 2. were also measured. Significantly more sGAG was lost from knee cartilage exposed to TNFα (22.2% vs 13.2%, P=0.01) and TNFα in combination with IL-1α (27.5% vs 16.0%, P=0.02) compared to the ankle; low cytokine concentrations did not affect sGAG release. Significantly more PGE. 2. was produced by knee cartilage compared to ankle cartilage however no significant difference in nitrite production was noted. Cartilage from the knee and ankle has a divergent response to stimulation by pro-inflammatory cytokines, with high concentrations of TNFα alone, or in combination with IL-1α amplifying cartilage degeneration. This differential response may account for the high prevalence of knee arthritis compared to ankle OA and provide a future pharmacological target to treat post traumatic arthritis of the knee


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 97 - 97
1 Mar 2006
Benzakour A Hefti M Lemseffer
Full Access

We have reviewed 183 patients (215 knees) assessing results and indications of High Tibial Osteotomies in medial gonarthrosis. Material: 128 females and 55 males. Follow up is 11.5 years, 120 cases with average varus angle 13° had opening ; 95 cases with average varus angle 10° had closing wedges. Ahlback classification showed stages I: 54, II: 71, III: 66 and IV: 24. H.S.S. scoring was 61 for opening and 68 for closing wedge. Results: 27 re-operations and 13 other complications. Healing delay was 55 days for closing and 70 for opening. R.O.M. was 125°. 25 knees are painful. 1/After opening, scoring is 77 and valgus angle is 3°. 2/After closing, scoring is 80 and valgus angle is 5°. 3/Global results: very good: 26%, good: 33%, medium: 28% and poor: 13%. Discussion: H.T.O. decreases stresses on medial compartment and widens joint space. No significant aggravation is observed at follow up. Clinical results are satisfying in early surgery. Reaxation is good for delaying or managing arthritis. The average of 5° mechanical valgus at osteotomy seems to be effective. Conclusions: -Opening wedge for medium severity and wide varus angle, till the age of 70. -Closing wedge for medium varus in younger patients. H.T.O. allows quite pain-free knees, restores axes and avoids or delays T.K.R. H.T.O. gives satisfactory results and should be then considered the best choice for early prevention and treatment of varus knee arthritis


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 67 - 67
1 Dec 2021
MacLeod A Belvedere C Fabbro GD Grassi A Nervuti G Leardini A Casonato A Zaffagnini S Gill H
Full Access

Abstract

Objectives

High tibial osteotomy for knee realignment is effective at relieving symptoms of knee osteoarthritis but the operation is surgically challenging. A new personalised treatment with simpler surgery using pre-operatively planned measurements from computed tomography (CT) imaging and 3D-printed implants and instrumentation has been designed and is undergoing clinical trial. The aim of this study was to evaluate the early clinical results of a preliminary pilot study evaluating the safety of this new personalised treatment.

Methods

The single-centre prospective clinical trial is ongoing (IRCCS Istituto Ortopedico Rizzoli; IRB-0013355; ClinicalTrials.gov NCT04574570), with recruitment completed and all patients having received the novel custom surgical treatment. To preserve the completeness of the trial reporting, only surgical aspects were evaluated in the present study. Specifically, the length of the implanted osteosynthesis screws was considered, being determined pre-operatively eliminating intraoperative measurements, and examined post-operatively (n=7) using CT image processing (ScanIP, Synopsys) and surface distance mapping. The surgical time, patient discharge date and ease of wound closure were recorded for all patients (n=25).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 63 - 63
1 Dec 2019
Schwab P Varady N Chen A
Full Access

Aim

Traditionally, serum white blood count (WBC), C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) have been utilized as markers to evaluate septic arthritis (SA). Recently, neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) have been identified as prognostic factors for treatment failure, mortality and morbidity in various clinical settings. To date, these markers have not been utilized for evaluating outcomes after hip and knee SA.

Thus, the purpose of this study was to determine the ability of admission NLR and PLR to predict treatment failure and postoperative 90-day mortality in hip and knee SA.

Method

A retrospective study was performed using our institutional research patient database to identify 235 patients with native hip and knee septic arthritis from 2000–2018. Patient demographics, comorbidities and social factors (alcohol intake, smoking and intravenous drug use) were obtained, and NLR and PLR were calculated based on complete blood count values (absolute neutrophil, lymphocyte and platelet count) on admission. Treatment failure was defined as any reoperation or readmission within 90 days after surgery. Receiver operating curves were analyzed, and optimal thresholds for NLR and PLR were determined using Youden's test. Univariate and multivariate analyses were performed to determine if these ratios were independent predictors of treatment failure and 90-day mortality after surgery. These ratios were compared to serum WBC, CRP, and ESR.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 464 - 464
1 Apr 2000
BERNARD J


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 358 - 358
1 May 2010
Tarabichi S Tarabichi Y
Full Access

Introduction: Patients with advanced osteoarthritis tend to have limited range of motion; the purpose of this in vivo anatomical study is to identify the anatomical structures responsible for limited knee movement in patient with osteoarthritis.

Materials and Methods: 42 quadriceps releases were performed in patients who had TKA. The releases were carried out utilizing subvastus approach and just before proceeding with the knee replacement surgery. The ranges of motion were documented before and after the release using digital photography and lateral portable x-ray. No bony resection was done, and no ligament release was performed. Quadriceps excursion was also studied under fluoroscopy in six volunteers throughout the range of movement

Results: The quadriceps release improved the range of motion in all patients; at least 135 degrees of flexion were obtained. The average of improvement in knee flexion after the release was 36 degrees. The presence of osteophytes or gross deformity did not influence the degree of improvement. The fluoroscopy study has shown that the average excursion of quadriceps muscle from 0 to 145 degrees is 7 cm. The excursion per degree varies throughout the range of motion; it is more per degree near full flexion and extension than around 90 degree of flexion

Conclusion: The limited excursion of the quadriceps muscle is the main limiting factor to knee flexion. Other pathological changes such as osteophytes, surface pathology, posterior capsule and the cruciate ligaments play very limited roles.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 64 - 71
1 Feb 1977
Freeman M Sculco T Todd R

A multi-centre clinical trial of ICLH (Freeman-Swanson) arthroplasty has been in progress since 1971. In this paper the results up to two years after operation are reported in seventy-one knees displaying at least 30 degrees of fixed flexion, 25 degrees of valgus or 20 degrees of varus, before operation. It has been found that knees displaying 70 degrees of fixed flexion, 70 degrees of valgus, 30 degrees of varus or 50 degrees of valgus/varus instability can be satisfactorily aligned and stabilised with acceptable function. Three knees required revision. The other complications are listed and were unremarkable in nature. These results depend upon the prosthesis and upon the operative technique. The latter avoids damage to healthy bone but does involve the replacement of the tissues in the midline of the knee.