Advertisement for orthosearch.org.uk
Results 1 - 20 of 437
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 6 - 6
17 Apr 2023
Maslivec A Leon D Cobb J
Full Access

Reports of improved functional outcome of Metal on Metal Hip Resurfacing Arthroplasty (mHRA) to Total Hip Replacement needs to be balanced with concerns of metal ion release. By removing cobalt-chrome, cHRA reduces these risks. To the author's knowledge, there is no data available on functional outcomes of cHRA, therefore the aim of the study was to compare the function between cHRA patients and mHRA patients. 24 patients received a unilateral cHRA (H1, Embody) and was compared to 24 age and gender matched patients with a unilateral mHRA (BHR, Smith and Nephew). All patients completed the Oxford Hip Score (OHS)[T2] and underwent gait analysis on an instrumented treadmill before and at a mean of 74wks (+/− 10) for mHRA and 53wks (+/− 2) for cHRA post op. Walking trials started at 4km/h and increased in 0.5km/h increments until a top walking speed (TWS) was achieved. Vertical ground reaction forces (GRF) were recorded along with the symmetry index (SI). Spatiotemporal measures of gait were also recorded. Vertical GRF were captured for the entire normalised stance phase using statistical parametric mapping (SPM; CI = 95%). The gain in OHS was similar: H1 (25-46), BHR(27-47). TWS increased by 19% with H1 (6.02 – 8.0km/hr), and 20% with BHR (6.02 – 7.37km/hr). SPM of the entire gait cycle illustrated the restoration of symmetry in both groups with no difference in GRF across the stance phase between groups at 5km/hr pre-op and post-op. At faster speeds (6.5km/hr), H1 patients had a mid-support GRF slightly closer to normal compared to BHR. Both groups increased step length similar from pre to post op (H1:0.76 – 0.85cm, BHR:0.77-0.86cm). In this study, subjective and objective functional outcome measures suggest that short term functional outcomes of ceramic resurfacing is not inferior to metal resurfacing


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 3 - 3
17 Nov 2023
Mahajan U Mehta S Chan S
Full Access

Abstract. Introduction. Intra-articular distal humerus OTA type C fractures are challenging to treat. When osteosynthesis is not feasible one can choose to do a primary arthroplasty of elbow or manage non-operatively. The indications for treatment of this fracture pattern are evolving. Objectives. We present our outcomes and complications when this cohort of patients was managed with either open reduction internal fixator (ORIF), elbow arthroplasty or non-operatively. Methods. Retrospective study to include OTA type C2 and C3 fracture distal humerus of 36 patients over the age of 50 years managed with all the three modalities. Patient's clinical notes and radiographs were reviewed. Results. Between 2016 and 2022, 21 patients underwent ORIF – group 1, 10 patients were treated with arthroplasty – group 2 and 5 were managed conservatively- group 3. The mean age of patients was 62 years in group 1, 70 years in group 2 and 76 years in group 3. The mean range of movement (ROM) arc achieved in the group 1 & 2 was 103 while group 3 was 68. At least follow up was 6 months. 5 patients in group 1 underwent metalwork removal and 2 patients in group 3 under arthroplasty. Conclusion. The outcomes of arthroplasty and ORIF are comparable, but reoperation rates and stiffness were higher in ORIF and conservative group. Surgeon choice and patient factors play important role in decision towards choosing treatment modality. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 14 - 14
17 Apr 2023
Bartolo M Newman S Dandridge O Provaggi E Accardi M Dini D Amis A
Full Access

No proven long-term joint-preserving treatment options exist for patients with irreparable meniscal damage. This study aimed to assess gait kinematics and contact pressures of novel fibre-matrix reinforced polyvinyl alcohol-polyethylene glycol (PVA-PEG) hydrogel meniscus implanted ovine stifle joints against intact stifles in a gait simulator. The gait simulator controlled femoral flexion-extension and applied a 980N axial contact force to the distal end of the tibia, whose movement was guided by the joint natural ligaments (Bartolo; ORS 2021;p1657- LB). Five right stifle joints from sheep aged >2 years were implanted with a PVA-PEG total medial meniscus replacement, fixed to the tibia via transosseous tunnels and interference screws. Implanted stifle joint contact pressures and kinematics in the simulator were recorded and compared to the intact group. Contact pressures on the medial and lateral condyles were measured at 55° flexion using Fujifilm Prescale Low Pressure film inserted under the menisci. 3D kinematics were measured across two 30 second captures using the Optotrak Certus motion-tracking system (Northern Digital Inc.). Medial peak pressures were not significantly different between the implanted and intact groups (p>0.4), while lateral peak pressures were significantly higher in the implanted group (p<0.01). Implanted stifle joint kinematics in the simulator did not differ significantly from the intact baseline (p>0.01), except for in distraction-compression (p<0.01). Our findings show that the fibre-matrix reinforced PVA-PEG hydrogel meniscal replacement restored the medial peak contact pressures. Similar to published literature (Fischenich; ABE 2018;46(11):1–12), the lateral peak pressures in the implanted group were higher than the intact. Joint kinematics were similar across groups, with slightly increased internal-external rotation in the implanted group. These findings highlight the effectiveness of the proposed approach and motivate future work on the development of a total meniscal replacement


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 73 - 73
17 Apr 2023
Condell R Flanagan C Kearns S Murphy C
Full Access

Despite considerable legacy issues, Girdlestone's Resection Arthroplasty (GRA) remains a valuable tool in the armoury of the arthroplasty surgeon. When reserved for massive lysis in the context of extensive medical comorbidities which preclude staged or significant surgical interventions, and / or the presence of pelvic discontinuity, GRA as a salvage procedure can have satisfactory outcomes. These outcomes include infection control, pain control and post-op function. We describe a case series of 13 cases of GRA and comment of the indications, peri, and post-operative outcomes. We reviewed all cases of GRA performed in our unit during an 8 year period, reviewing the demographics, indications, and information pertaining to previous surgeries, and post op outcome for each. Satisfaction was based on a binary summation (happy/unhappy) of the patients’ sentiments at the post-operative outpatient consultations. 13 cases were reviewed. They had a mean age of 75. The most common indication was PJI, with 10 cases having this indication. The other three cases were performed for avascular necrosis, pelvic osteonecrosis secondary to radiation therapy and end stage arthritis on a background of profound learning disability in a non-ambulatory patient. The average number of previous operations was 5 (1-10). All 13 patients were still alive post girdlestone. 7 (54%) were satisfied, 6 were not. 3 patients were diabetic. 5 patients developed a sinus tract following surgery. With sufficient pre-op patient education, early intensive physiotherapy, and timely orthotic input, we feel this procedure remains an important and underrated and even compassionate option in the context of massive lysis and / or the presence of pelvic discontinuity / refractory PJI. GRA should be considered not a marker of failure but as a definitive procedure that gives predictability to patients and surgeon in challenging situations


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 119 - 119
1 Jul 2014
Razak A Ebinesan A Charalambous C
Full Access

Summary Statement. Routine metal allergy screening prior to joint arthroplasty is not essential and the use of cobalt chromium or stainless steel implants is recommended regardless of the patient's metal allergy status. Introduction. This study was undertaken to obtain a consensus amongst joint arthroplasty experts with regards to metal allergy screening prior to joint arthroplasty and the choice of implant in patients with potential metal allergy. Patients & Methods. A web based Delphi consensus study was used including orthopaedic surgeons that had previously published on the topic of knee, hip or shoulder arthroplasty. Two rounds of questionnaires were sent via electronic mail. Consensus was considered if agreement was 60% or higher. Results. 18 surgeons responded to the first and 17 to the second round of questionnaires. There was consensus that patients having metal arthroplasty surgery should not be routinely questioned about metal allergy prior to surgery. There was consensus that patch testing is not necessary even if metal allergy is suspected. Most respondents agreed in proceeding with cobalt chromium or stainless steel implant in patients suspected of metal allergy regardless of the results of cutaneous patch testing. Discussion/Conclusion. This consensus study suggests that routine metal allergy screening prior to joint arthroplasty is not essential. The use of traditional cobalt chromium/stainless steel implants is recommended regardless of the patient's metal allergy status


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 32 - 32
4 Apr 2023
Pareatumbee P Yew A Meng Chou S Koh J Zainul-Abidin S Howe T Tan M
Full Access

To analyse bone stresses in humerus-megaprosthesis construct in response to axial loading under varying implant lengths in proximal humeral replacement following tumour excision. CT scans of 10 cadaveric humeri were processed in 3D Slicer to obtain three-dimensional (3D) models of the cortical and cancellous bone. Megaprostheses of varying body lengths (L) were modelled in FreeCAD to obtain the 3D geometry. Four FE models: group A consisting of intact bone; groups B (L=40mm), C (L=100mm) and D (L=120mm) comprising of humerus-megaprosthesis constructs were created. Isotropic linear elastic behaviour was assigned for all materials. A tensile load of 200N was applied to the elbow joint surface with the glenohumeral joint fixed with fully bonded contact interfaces. Static analysis was performed in Abaqus. The bone was divided at every 5% bone length beginning distally. Statistical analysis was performed on maximum von Mises stresses in cortical and cancellous bone across each slice using one-way ANOVA (0-45% bone length) and paired t-tests (45-70% bone length). To quantify extent of stress shielding, average percentage change in stress from intact bone was also computed. Maximum stress was seen to occur distally and anteriorly above the coronoid fossa. Results indicated statistically significant differences between intact state and shorter megaprostheses relative to longer megaprostheses and proximally between intact and implanted bones. Varying levels of stress shielding were recorded across multiple slices for all megaprosthesis lengths. The degree of stress shielding increased with implant lengthening being 2-4 times in C and D compared to B. Axial loading of the humerus can occur with direct loading on outstretched upper limbs or indirectly through the elbow. Resultant stress shielding effect predicted in longer megaprosthesis models may become clinically relevant in repetitive axial loading during activities of daily living. It is recommended to use shorter megaprosthesis to prevent failure


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 118 - 118
1 Nov 2021
Pareatumbee P Yew A Koh JSB Howe TS Abidin SZ Tan MH
Full Access

Introduction and Objective. Curative resection of proximal humerus tumours is now possible in this era of limb salvage with endoprosthetic replacement considered as the preferred reconstructive option. However, it has also been linked with mechanical and non-mechanical failures such as stem fracture and aseptic loosening. One of the challenges is to ensure that implants will endure the mechanical strain under physiological loading conditions, especially crucial in long surviving patients. The objective is to investigate the effect of varying prosthesis length on the bone and implant stresses in a reconstructed humerus-prosthesis assembly after tumour resection using finite element (FE) modelling. Methods. Computed tomography (CT) scans of 10 humeri were processed in Mimics 17 to create three-dimensional (3D) cortical and cancellous solid bone models. Endoprostheses of different lengths manufactured by Stryker were modelled using Solidworks 2020. The FE models were divided into four groups namely group A consisting of the intact humerus and groups B, C and D composed of humerus-prosthesis assemblies with a body length of 40, 100 and 120 mm respectively and were meshed using linear 4-noded tetrahedral elements in 3matic 13. The models were then imported into Abaqus CAE 6.14. Isotropic linear elastic behaviour with an elastic modulus of 13400, 2000 and 208 000 MPa were assigned to the cortical bone, cancellous bone and prosthesis respectively and a Poisson's ratio of 0.3 was assumed for each material. To represent the lifting of heavy objects and twisting motion, a tensile load of 200 N for axial loading and a 5 Nm torsional load for torsional loading was applied separately to the elbow joint surface with the glenohumeral joint fixed and with all contact interfaces defined as fully bonded. A comparative analysis against literature was performed to validate the intact model. Statistical analysis of the peak von Mises stress values collected from predicted stress contour plots was performed using a one-way repeated measure of analysis of variance (with a Bonferroni post hoc test) using SPSS Statistics 26. The average change in stress of the resected models from the intact state were then determined. Results. The validation of the intact humerus displayed a good agreement with literature values. The peak bone stress occurred distally above the coronoid and olecranon fossa closer to the load application region in the intact and resected bone models with a significant amount of loading borne by the cortical bone, while the peak implant stress occurred at the bone-prosthesis contact interface under both loading conditions. Based on the results obtained, a statistically significant difference (p =.013) in implant stress was only seen to occur between groups B and C under tension. Results illustrate initiation of stress shielding with the bone bearing lesser stress with increasing resection length which may eventually lead to implant failure by causing bone resorption according to Wolff's law. The peak implant stress under torsion was 3–5 times the stress under tension. The best biomechanical behaviour was exhibited in Group D, having the least average change in stress from the intact model, 5% and 3.8% under tension and torsion respectively. It can be deduced that the shorter the prosthesis length, the more pronounced the effect on cortical bone remodelling. With the maximum bone and implant stresses obtained being less than their yield strength, it can be concluded that the bone-implant construct is safe from failure. Conclusions. The developed FE models verified the influence of varying the prosthesis length on the bone and implant stresses and predicted signs of stress shielding in longer endoprostheses. By allowing for 2 cm shortening in the upper extremity and post-surgical scarring, it is beneficial to err towards a shorter endoprosthesis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 47 - 47
17 Apr 2023
Akhtar R
Full Access

To compare the efficacy of intra-articular and intravenous modes of administration of tranexamic acid in primary total knee arthroplasty in terms of blood loss and fall in haemoglobin level.

Study Design: Randomized controlled trial.

Duration of Study: Six months, from May 2019 to Nov 2019.

Seventy-eight patients were included in the study. All patients undergoing unilateral primary total knee replacement were included in the study. Exclusion criteria were patients with hepatitis B and C, history of previous knee replacement, bilateral total knee replacement, allergy to TXA, Hb less than 11g/dl in males and less than 10g/dl in females, renal dysfunction, use of anticoagulants for 7 days prior to surgery and history of thromboembolic diseases. Patients were randomly divided into group A and B. Group A patients undergoing unilateral primary total knee replacement (TKR) were given intravenous tranexamic acid (TXA) while group B were infiltrated with intra-articular TXA. Volume of drain output, fall in haemoglobin (Hb) level and need for blood transfusion were measured immediately after surgery and at 12 and 24 hours post operatively in both groups.

The study included 35 (44.87%) male and 43 (55.13%) female patients. Mean age of patients was 61 ± 6.59 years. The mean drain output calculated immediately after surgery in group A was 45.38 ± 20.75 ml compared with 47.95 ± 23.86 ml in group B (p=0.73). At 24 hours post operatively, mean drain output was 263.21 ± 38.50 ml in intravenous group versus 243.59 ± 70.73 ml in intra-articular group (p=0.46). Regarding fall in Hb level, both groups showed no significant difference (p>0.05). About 12.82% (n=5) patients in group A compared to 10.26% (n=4) patients required blood transfusion post operatively (p=0.72).

Intra-articular and intravenous TXA are equally effective in patients undergoing primary total knee arthroplasty in reducing post-operative blood loss.


Bone & Joint Research
Vol. 6, Issue 9 | Pages 566 - 571
1 Sep 2017
Cheng T Zhang X Hu J Li B Wang Q

Objectives. Surgeons face a substantial risk of infection because of the occupational exposure to blood-borne pathogens (BBPs) from patients undergoing high-risk orthopaedic procedures. This study aimed to determine the seroprevalence of four BBPs among patients undergoing joint arthroplasty in Shanghai, China. In addition, we evaluated the significance of pre-operative screening by calculating a cost-to-benefit ratio. Methods. A retrospective observational study of pre-operative screening for BBPs, including hepatitis B and C viruses (HBV and HCV), human immunodeficiency virus (HIV) and Treponema pallidum (TP), was conducted for sequential patients in the orthopaedic department of a large urban teaching hospital between 01 January 2009 and 30 May 2016. Medical records were analysed to verify the seroprevalence of these BBPs among the patients stratified by age, gender, local origin, type of surgery, history of previous transfusion and marital status. Results. Of the subjects who underwent arthroplasty surgery in our institution, pre-operative screening tests were available for 96.1% (11 609 patients). The seroprevalence of HBV, HCV, HIV and TP was 5.47%, 0.45%, 0.08% and 3.6%, respectively. A total of 761 seropositive cases (68.4%) were previously undiagnosed. Pre-operative screening for HIV resulted in a low cost to benefit ratio, followed by HCV and HBV. Conclusion. Routine HCV and HIV screening prior to joint arthroplasty is not a cost-effective strategy. Considering the high rate of undiagnosed patients and the shortage of protective options, targeted pre-operative screening for HBV and syphilis should be considered for the protection of healthcare workers in China who have not been vaccinated. Cite this article: Bone Joint Res 2017;6:566–571


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 65 - 65
1 Apr 2017
Patel A Li L Rashid A
Full Access

Background. Radial head fractures are the commonest fractures involving the elbow. The goals of treatment are to restore stability, preserve motion, and maintain the relative length of the radius. Fortunately, most simple uncomplicated fractures can be treated non-operatively. Choosing between fixation and radial head replacement for comminuted fractures remains difficult. Excision of radial head fractures is not an ideal option in unstable elbow injuries. The purpose of this systematic review was to search for and critically appraise articles directly comparing functional outcomes and complications for fixation (open reduction internal fixation, ORIF) versus arthroplasty for comminuted radial head fractures (Mason type 3) in adults. Method. A comprehensive search of Medline, Embase and Cochrane databases using specific search terms and limits was conducted. Strict eligibility criteria were applied to stringently screen resultant articles. Three comparative studies were identified and reviewed. Results. Three comparative studies were identified and reviewed: two studies found significantly better Broberg & Morrey functional scores after replacement compared with ORIF in Mason type 3 fractures. The third study found no significant differences in Mayo functional score or range of motion, but did find that grip strength was better after ORIF. Complication rates were too heterogenous for conclusion. Conclusion. Fixation with good reduction may be attempted in unstable Mason type 3 fractures, and arthroplasty may be considered if this is not possible. Further randomised comparative trials are required to clarify the decision-making between fixation and replacement. Functional outcomes and complications were conflicting in the studies included here. Ideally, treatment decision should take into account elbow stability and degree of comminution


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 27 - 27
1 May 2017
Matthews A Jagodzinski N Westwood M Metcalfe J Trimble K
Full Access

The Cobb Stainsby forefoot arthroplasty for claw and hammer toes combines excision arthroplasty (Stainsby) with extensor tendon transfer to the metatarsal head (Cobb). We present a retrospective, three surgeon case series of 218 toes in 128 patients over four years. Clinical notes were reviewed for all patients and 77 could be contacted for a telephone survey. Follow up ranged from 12–82 months. All patients presented with pain and shoe wear problems from dislocated metatarsophalangeal joints either from arthritis, hallux valgus, Freiberg's disease or neurological disorders. Ipsilateral foot procedures were performed simultaneously in 24 (30%) patients. Seventy-two patients (94%) were satisfied, 72 (94%) reported pain relief, 55 (71%) were happy with toe control, 61 (79%) were pleased with cosmesis, 59 (77%) returned to normal footwear and 56 (73%) reported unlimited daily activities. Minor complications occurred in 17 (13%) and 3 (2%) developed complex regional pain syndrome. Four (5%) developed recurrent clawing. The Stainsby procedure permits relocation of the plantar plate under the metatarsal head for cushioned weight-bearing but can create a floppy, unsightly toe. By combining this with the Cobb procedure, our case series demonstrates improved outcomes from either procedure alone with benefits over alternatives such as the Weil's osteotomy. Oxford Level 4 evidence – retrospective case series


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 84 - 84
1 May 2017
Wylde V Sayers A Lenguerrand E Beswick A Gooberman-Hill R Pyke M Dieppe P Blom A
Full Access

Background. Chronic pain after joint replacement is common, affecting approximately 10% of patients after total hip replacement (THR) and 20% of patients after total knee replacement (TKR). Heightened generalised sensitivity to nociceptive input could be a risk factor for the development of this pain. The primary aim of this study was to investigate whether preoperative widespread pain sensitivity was associated with chronic pain after joint replacement. Methods. Data were analysed from 254 patients receiving THR and 239 patients receiving. TKR. Pain was assessed preoperatively and at 12 months after surgery using the Western Ontario and McMaster Universities Osteoarthritis Pain Scale. Preoperative widespread pain sensitivity was assessed through measurement of pressure pain thresholds (PPTs) at the forearm using an algometer. Statistical analysis was conducted using linear regression and linear mixed models, and adjustments were made for confounding variables. Results. In both the THR and TKR cohort, lower PPTs (heightened widespread pain. sensitivity) were significantly associated with higher preoperative pain severity. Lower PPTs were also significantly associated with higher pain severity at 12 months after surgery in the THR cohort. However, PPTs were not associated with the change in pain severity from preoperative to 12 months postoperative in either the TKR or THR cohort. Conclusions. These findings suggest that although preoperative widespread pressure pain sensitivity is associated with pain severity before and after joint replacement, it is not a predictor of the amount of pain relief that patients gain from joint replacement surgery, independent of preoperative pain severity. Level of Evidence. 2. Approvals. The APEX trials were registered as an International Standardised Randomised Controlled Trial (96095682), approved by Southampton and South West Hampshire Research Ethics Committee(09/H0504/94) and all participants provided informed written consent


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 1 - 1
1 Jan 2019
Logishetty K Van Arkel R Muirhead-Allwood S Ng G Cobb J Jeffers J
Full Access

The hip's capsular ligaments (CL) passively restrain extreme range of motion (ROM) by wrapping around the native femoral head/neck, and protect against impingement and instability. We compared how CL function was affected by device (hip resurfacing arthroplasty, HRA; dual mobility total hip arthroplasty, DM-THA; and conventional THA, C-THA), and surgical approach (anterior and posterior), with and without CL surgical-repair. We hypothesized that CL function would only be preserved when native head-size (HRA/DM-THA) was restored. CL function was quantified on sixteen cadaveric hips, by measuring ROM by internally (IR) and externally rotating (ER) the hip in six functional positions, ranging from full extension with abduction to full flexion with adduction (squatting). Native ROM was compared to ROM after posterior capsulotomy (right hips) or anterior capsulotomy (left hips), and HRA, and C-THA and DM-THA, before and after CL repair. Independent of approach, ROM increased most following C-THA (max 62°), then DM-THA (max 40°), then HRA (max 19°), indicating later CL engagement and reduced biomechanical function with smaller head-size. Dislocations also occurred in squatting after C-THA and DM-THA. CL-repair following HRA restored ROM to the native hip (max 8°). CL-repair following DM-THA reduced ROM hypermobility in flexed positions only and prevented dislocation (max 36°). CL-repair following C-THA did not reduce ROM or prevent dislocation. For HRA and repair, native anatomy was preserved and ligament function was restored. For DM-THA with repair, ligament function depended on the movement of the mobile-bearing, with increased ROM in positions when ligaments could not wrap around head/neck. For C-THA, the reduced head-size resulted in inferior capsular mechanics in all positions as the ligaments remained slack, irrespective of repair. Choosing devices with anatomic head-sizes (HRA/DM-THA) with capsular repair may have greater effect than surgical approach to protect against instability in the early postoperative period


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 54 - 54
1 Dec 2021
Maslivec A Ng KCG Cobb J
Full Access

Abstract

Objectives

Although hip replacement and resurfacing procedures both aim to restore mobility, improve joint function, and relieve pain, it is unclear how each differ in terms of gait mechanics and if they are affected by varying walking speeds. We compared limb symmetry and ground reaction force (GRF) profiles between bilateral total hip arthroplasty patients (THA), bilateral hip resurfacing arthroplasty patients (HRA), and healthy control participants (CON) during level-treadmill walking at different speeds.

Methods

Bilateral THA and bilateral HRA patients (nTHA = 15; nHRA = 15; postoperative 12–18 months), and age-, mass-, and height-matched CON participants (nCON = 20) underwent gait analysis on an instrumented treadmill. Walking trials started at 4 km/h and increased in 0.5 km/h increments until top walking speed (TWS) was achieved. Gait symmetry index (SI = 0% for symmetry) was assessed between limbs during weight-acceptance, mid-stance and push-off phases of gait; and vertical GRFs were captured for the normalised stance phase using statistical parametric mapping (SPM; CI = 95%).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 46 - 46
1 Nov 2018
Tuleubayev B Saginova D Arutyunyan M Kerimbekov T Uulu AD
Full Access

Recently in traumatology various methods of impregnation biodegradable implants and allografts with antibiotics are widely used. Among them the soaking, shaking and ionophores are common used. We aimed to choose the optimal method of impregnation with the antibiotic of the head of the femur, taken from patients after arthroplasty. We studied 6 femoral heads after hip replacement. Head №1 the iohexol (Omnipaque) was injected through circular ligament and through the neck of the femur. Head №2 through the circular ligament, head №3 through the neck of the femur, head №4 through the circular ligament and through the neck of the femur, head №5 through 4 pre-drilled channels a brilliant green solution was injected. The head №6 was soaked in a brilliant green solution. Head №1 assessed by radiology. All the heads, treated with brilliant green, were cut in half to assess the degree of impregnation. On the X-ray image of head №1 the contrast agent has spread enough. In osteotomy, the impregnation with brilliant green head №2, №3, №4, №5 was seen in 3–4 mm around the needle passage place. Head №6 the bone was not impregnated. Despite the fact that the radiograph showed a sufficient spread of contrast agent, on the sections of the head, treated with brilliant green, showed the spread of liquid 3–4 mm around the needle passage place. This indicates that the impregnation of large bone is not effective


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 8 - 8
1 Apr 2015
Russo L Ferguson K Winter A MacGregor M Holt G
Full Access

Introduction. Acute kidney injury is a recognised post-operative complication in primary joint replacement. Recently it has been demonstrated that antibiotic regimen can significantly impact on the proportion of patients who develop acute kidney impairment post-operatively. Within our unit an increased rate of acute kidney injury had been noted post-operatively over the last 5 years. This increase followed the introduction of a rapid recovery protocol for arthroplasty patients. Our aim was determine whether we could identify a causative factor or those who were at increased risk of post-operative renal impairment. Methods. Data were collected for 413 patients initially retrospectively but continued prospectively. Univariable and multivariable analysis was performed to determine any causative factors. The primary increase was 150% increase in baseline creatinine, but as some authors recognise an increase in 125% this was also analysed. Results. Within the 12 month period studied 23.3% of patients developed acute kidney injury, with an increase of 125% of their baseline creatinine. 8.23% of patients developed an increase of 150% in their creatinine levels. Age, previous renal failure and the pre-operative use of an ACE inhibitor were found to be statistically higher in the renal failure group. The uni-variable analysis also demonstrated that patients who received a small volume of post-operative intravenous fluids had a lower rate of renal failure than those who received no fluids (10% vs. 23%; p = 0.04). The multivariable regression analysis demonstrated that age was the only statistically significant positive predictive factor in developing renal failure. Antibiotic regimen had no effect. Discussion. Renal impairment has significant impact on patient morbidity and post-operative management. It increases the length of stay, and may potentially require more invasive therapy. We have demonstrated that the identified risk factors are non-modifiable but that a gentamicin and teicoplanin regimen was not an implicated causative factor


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 75 - 75
1 Jan 2017
Anand A Li L Trigkilidas D Patel A
Full Access

We performed a systematic review to compare outcomes of cemented versus uncemented trapezio-metacarpal joint (TMCJ) replacement for treatment of base-of-thumb arthritis. We assessed improvements in pain and function, range of movement (ROM), strength, complications and need for revision surgery. A thorough literature search was performed. A total of 481 studies were identified from the literature search (179 Medline, 253 Embase, 27 CINAHL, 22 Cochrane). Of 43 relevant titles 28 were selected for full-text review after assessment of the abstracts. Duplicate studies were removed. 18 studies met inclusion criteria on full-text review. All studies were of level IV evidence. There were no randomised controlled trials or meta-analyses. The studies were critically appraised using a validated scoring system. Most studies reported good outcomes for pain and strength, and functional outcome was comparable for both groups. ROM was generally improved for both prosthetic types, however statistical calculation was lacking in many studies. Trapezial component loosening was the main problem for both cemented and uncemented prostheses, however radiological loosening did not necessarily correlate with implant failure. This systematic review has found that both cemented and uncemented replacements generally give good outcomes for the treatment of TMCJ arthritis, however young, male, patients with manual occupations and with disease in the dominant hand and patients with poor trapezial bone stock appear to be at higher risk for implant failure due to cup loosening. We recommend the construction of a joint registry to record implantation and revision rates


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 741 - 744
1 May 2005
Beaulé PE Krismer M Mayrhofer P Wanner S Le Duff M Mattesich M Stoeckl B Amstutz HC Biedermann R

Studies on the migration of an implant may be the only way of monitoring the early performance of metal-on-metal prostheses. The Ein Bild Roentgen Analyse - femoral component analysis (EBRA-FCA) method was adapted to measure migration of the femoral component in a metal-on-metal surface arthroplasty of the hip using standard antero-posterior radiographs. In order to determine the accuracy and precision of this method a prosthesis was implanted into cadaver bones. Eleven series of radiographs were used to perform a zero-migration study. After adjustment of the femoral component to simulate migration of 3 mm the radiographs were repeated. All were measured independently by three different observers. The accuracy of the method was found to be ± 1.6 mm for the x-direction and ± 2 mm for the y-direction (95% percentile). The method was validated using 28 hips with a minimum follow-up of 3.5 years after arthroplasty. Seventeen were sound, but 11 had failed because of loosening of the femoral component. The normal (control) group had a different pattern of migration compared with that of the loose group. At 29.2 months, the control group showed a mean migration of 1.62 mm and 1.05 mm compared with 4.39 mm and 4.05 mm in the failed group, for the centre of the head and the tip of the stem, respectively (p = 0.001). In the failed group, the mean time to migration greater than 2 mm was earlier than the onset of clinical symptoms or radiological evidence of failure, 19.1 versus 32.2 months (p = 0.001) and 24.8 months (p = 0.012), respectively. EBRA-FCA is a reliable and valid tool for measuring migration of the femoral component after surface arthroplasty and can be used to predict early failure of the implant. It may be of value in determining the long-term performance of surface arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 22 - 22
1 Oct 2016
Ramakrishnan P Maclean M MacGregor SJ Anderson J Grant MH
Full Access

Healthcare associated infections (HAI) pose a major threat to patients admitted to hospitals, and infection rates following orthopaedic arthroplasty surgery are as high as 4%, while the infection rates are even higher after revision surgery. 405 nm High-Intensity Narrow Spectrum (HINS) light has been proven to reduce environmental contamination in hospital isolation rooms, and there is potential to develop this technology for application in orthopaedic surgery. Cultured rat osteoblasts were exposed to 405 nm light to investigate if bactericidal doses of light could be used safely in the presence of mammalian cells. Cell viability was measured by MTT reduction and microscopy techniques, function by alkaline phosphatase activity, and proliferation by the BrdU assay. Exposures of up to a dose of 36 J/cm. 2. had no significant effect on osteoblast cell viability, whilst exposure of a variety of clinically relevant bacteria, to 36 J/cm. 2. resulted in up to 100% kill. Exposure to a higher dose of 54 J/cm. 2. significantly affected the osteoblast cell viability, indicating dose dependency. Work also demonstrated that 405 nm light exposure induces reactive oxygen species (ROS) production in both mammalian and bacterial cells, as shown by fluorescence generated from 6-carboxy-2′,7′-dichlorodihydrofluorescein diacetate dye. The mammalian cells were significantly protected from dying at 54 J/cm. 2. by catalase, which detoxifies H. 2. O. 2. Bacterial cells were significantly protected by sodium pyruvate (H. 2. O. 2. scavenger) and by a combination of free radical scavengers (sodium pyruvate, dimethyl thiourea (·OH scavenger), catalase) at 162 and 324 J/cm. 2. Thus the cytotoxic mechanism of 405 nm light in mammalian cells and bacteria is likely oxidative stress involving predominantly H. 2. O. 2. generation, with other ROS contributing to the damage. Additional work describing the potential for incorporation of this antimicrobial light within operating theatre lighting systems will also be discussed, and this, coupled with the cell viability and cytotoxicity results, suggests that 405 nm light could have great potential for continual patient safe decontamination during orthopaedic replacement surgeries and thereby reduce the incidence of infections


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 29 - 29
1 Jul 2014
Hamilton D Lane J Gaston P Patton J MacDonald D Simpson H Howie C
Full Access

Summary Statement. Service industry metrics (the net promoter score) are being introduced as a measure of UK healthcare satisfaction. Lower limb arthroplasty, as a ‘service’, scores comparably with the most successful commercial organisations. Background. Satisfaction with care is important to both the patient and the payer. The Net Promoter Score, widely used in the service industry, has been recently introduced to the UK National Health Service as an overarching metric of patient satisfaction and to monitor performance. This questionnaire asks ‘customers’ if they would recommend a service or products to others. Scores range from −100 (everyone is a detractor) to +100 (everyone is a promoter). In industry, a positive score is well regarded, with those over 50 regarded as excellent. Our aims were to assess net promoter scores for joint arthroplasty, to compare these scores with direct measures of patient satisfaction, and to evaluate which factors contributed to net promoter response. Methods. 6912 individuals undergoing primary lower limb joint replacement over a five year period (Jan 2007 – Dec 2011) took part in a prospective cohort study at a single NHS University hospital. Net promoter score, clinical outcomes as measured by PROMS (Oxford Hip or Knee Score and SF-12 score), multi-faceted patient satisfaction questionnaire, demographic data and length of hospital stay were recorded. Data was collected preoperatively and at 1 year post-surgery. Multivariate regression was performed to determine which factors could predict an outcome of ‘promoter’ and ‘detractor’ at 1 year post-surgery. Significance was accepted at p = 0.1 to accommodate the confounding effect of other variables. Results. Net promoter scores for knee and hip replacements were 49 and 71 respectively. Strong correlation was seen between overall satisfaction and whether the patient would recommend the operation to another (r = 0.637), though regression of these factors was modest (R. 2. = 0.406). Only 4 factors were relevant to the net promoter response: pain relief (OR 2.13, CI 1.83 – 2.49), meeting expectations (OR 2.57, CI 2.24 – 2.97), hospital experience (OR 2.33, CI 2.03 – 2.68) and arthroplasty type (OR 2.31, CI 1.68 – 3.17). These factors drove a model able to explain 95% of the variation in net promoter score. Conclusions. This is the first analysis of net promoter score for joint arthroplasty, and demonstrates values that compare favourably with the services provided by the most successful commercial organizations. The UK Department of Health describes this score as a measure of patient satisfaction. This is perhaps not completely accurate, as only a third of the variation in one response can be explained by the other, suggesting that although clearly related, these concepts are not the same. Pain relief, meeting of expectations of surgery, the hospital experience and whether the hip or knee joint is replaced are the only relevant factors in determining the net promoter response. Factors thought to influence clinical outcome such as depression, number of comorbidities, age and gender carry no influence with this metric