Objective. We reviewed clinical results with minimally invasive method and using a new developed plate for unstable pelvic ring fractures, especially vertically unstable sacral fractures. Materials & Methods. Between 2002 and 2010, 35 patients with vertically unstable sacral fractures were treated with minimally invasive method and using an M-Shaped transiliac plate which was developed by the author. This plate is anatomically designed for posterior pelvic ring, and achieved rigid fixation. Patients included 19 male and 16 female, with the mean age of 46.2 (range, 17∼79) years old. According to the AO classification, 23 patients had a C1 injury, 9 had a C2 fracture, and 3 patients sustained a C3 injury of the pelvic ring. Functional outcome was assessed using the Majeed's functional evaluation and radiography. Minimum follow-up was one year. Results. All patients were not fixed anterior of pelvic ring. The average of surgical time was 85 minutes (range: 45∼150), and
Purpose. In stabilisations of atlantoaxial instabilities it holds risks to injure the A. vertebralis as well as neurological structures. Furthermore the posterior approach of the upper part of the cervical spine requires a huge and traumatic preparation of the soft tissue. However the anterior transarticular C1-2 fusion (ATF) is less traumatic and offers almost the same strengh of the stabilisation. Methods. Since the 01/2007 22 multimorbid patients with atlanto-axial instabilities of different entities were treated via the ATF, were regular examined radiologicaly (x-ray/CT) and the procedure critically judged. Results. C1-2 fusions were performed in 22 patients (17f, 5m, Ø 81,67 years). Main symptoms was pain radiating in the upper cervical spine and the occiput, 2 Patients complaining radiating pain with paraesthesia. The average operation-time took 64,5 min. Leftside the screws of Ø 39,5mm (32–44mm), rightside of 36mm (32–44mm) were inserted in addiction to the point of access and the angle of insertion (mediolateral angle Ø 32,0°, ventrodorsal Ø17,6°). No introperative complications occured, one revision had to be done because of p.o. bleeding, one because of screw dislocation. Postoperative x-ray and CT control of the upper cervical spine showed 30/44 screws in 22 patients in correct position. 8 (18,2%) screws were too long, 3 (6,8%) screws were placed too anterior and 3 (6,8%) too medial. 8 additional positionated dens-screws were in correct position. After a clear learning curve both screws of the 6th patient were positoinated correct. Two aspects are important for success: Correct entry point and right insertion of the angle in the coronar and sagittal view. A low
Introduction. Surgical treatment of spinal metastasis belongs to the standards of oncology. The risk of spinal cord compression represents an operative indication. Intraoperative bleeding may vary, depending on the extent of the surgical technique. Some primary tumors, such as the renal cell carcinoma, present a major risk for hemorrhage and preoperative embolisation is mandatory. The purpose of this study is to evaluate the possible benefit of embolisation in different types of primary tumors. Material and Methods. The charts of 93 patients (42 women, 51 men, mean age 60.5 years) who were operated for spinal metastasis, 30 cases with multiple levels, were reviewed. Surgical procedures were classified as: (1) thoracolumbar laminectomy and instrumentation, (2) thoracolumbar corpectomy or vertebrectomy, (3) cervical corpectomy. A preoperative microsphere embolisation was performed in 35 patients. The following parameters, describing blood loss, were evaluated: hemoglobin variation from beginning to end of surgery, blood volume in suction during the intervention, number transfused packed red blood cells units until day 5 after surgery. A Poisson model was used for statistical evaluation. Results. The origins of spinal metastasis were: 28 breast cancer (30.1%), 19 pulmonary carcinoma (20.4%), 16 renal cell carcinoma (17.2%), 30 other cancers (32.3%). An embolisation was always performed in metastasis of renal cell carcinoma. An embolisation was performed in 8 cases in breast, 3 in pulmonary and 9 in other cancers. In the breast cancer group, there was no difference between embolisation versus non-embolisation concerning
The aim of this study was to examine perioperative blood transfusion practice, and associations with clinical outcomes, in a national cohort of hip fracture patients. A retrospective cohort study was undertaken using linked data from the Scottish Hip Fracture Audit and the Scottish National Blood Transfusion Service between May 2016 and December 2020. All patients aged ≥ 50 years admitted to a Scottish hospital with a hip fracture were included. Assessment of the factors independently associated with red blood cell transfusion (RBCT) during admission was performed, alongside determination of the association between RBCT and hip fracture outcomes.Aims
Methods
Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes. In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes.Aims
Methods
A lack of supporting clinical studies have been published to determine the ideal length of intramedullary nail in fixation of trochanteric fractures of the hip. Nevertheless, there has been a trend to use shorter intramedullary nails for the internal fixation of trochanteric hip fractures. Our aim was to determine if the length of nail affected the outcome. We randomized 229 patients with a trochanteric hip fracture between two implants: a ‘standard’ nail of 220 mm and a shorter nail of 175 mm, which had decreased proximal angulation (4° vs 7°) and a reduced diameter at the level of the lesser trochanter. Patients were followed up for one year by a nurse blinded to the type of implant used to determine if there were differences in mobility and pain with two nail designs. Pain was assessed on a scale of 1 (none) to 8 (severe and constant) and mobility on a scale of 1 (full mobility) to 9 (immobile).Aims
Methods