Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 70 - 70
1 Mar 2021
Scattergood S Flannery O Berry A Fletcher J Mitchell S
Full Access

Abstract. Objectives. The use of cannulated screws for femoral neck fractures is often limited by concerns of avascular necrosis (AVN) occurring, historically seen in 10–20% of fixed intracapsular fractures. The aim of this study was to investigate the rate of AVN with current surgical techniques within our unit. Methods. A single centre retrospective review was performed. Operative records between 1st July 2014 and 31st May 2019 were manually searched for patients with an intracapsular neck of femur fracture fixed with cannulated screws, with minimum one year follow up. Patient records and radiographs were reviewed for clinical and radiographic diagnoses of AVN and/or non-union. Fracture pattern and displacement, screw configuration and reduction techniques were recorded, with radiographs independently analysed by five orthopaedic surgeons. Results. Sixty-five patients were identified, average age of 72 years (range 48–87). Thirty-six patients (55%) sustained displaced fractures and 29 patients (45%) had undisplaced fractures. Two (3%) patients developed AVN, with no cases of fracture non-union. Ten patients (15%) sustained a high-energy injury, though none of these patients developed AVN. Screws configurations were: two (3%) triangle apex-superior, 39 (60%) triangle apex-inferior, 22 (34%) rhomboid and two (3%) other, with nine (14%) cases using washers. All fractures required closed reduction; no open reductions performed. Conclusions. Our observed AVN rate is much lower than widely reported, especially given the proportion of displaced fractures that were fixed. With adequate fixation, even in displaced fracture patterns with imperfect reduction, cannulated screws are an excellent option for intracapsular neck of femur fractures. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 35 - 35
1 Dec 2020
Scattergood SD Berry AL Flannery O Fletcher JWA Mitchell SR
Full Access

Intracapsular neck of femur fractures may be treated with fixation or arthroplasty, depending on fracture characteristics and patient factors. Two common methods of fixation are the sliding hip screw, with or without a de-rotation screw, and cannulated screws. Each has its merits, and to date there is controversy around which method is superior, with either method thought to risk avascular necrosis of the femoral head (AVN) rates in the region of 10–20%. Fixation with cannulated screws may be performed in various ways, with current paucity of evidence to show an optimum technique. There are a multitude of factors which are likely to affect patient outcomes: technique, screw configuration, fracture characteristics and patient factors. We present a retrospective case series analysis of 65 patients who underwent cannulated screw fixation of a hip fracture. Electronic operative records were searched from July 2014 until July 2019 for all patients with a neck of femur fracture fixed with cannulated screws: 68 were found. Three patients were excluded on the basis of them having a pathological fracture secondary to malignancy, cases were followed up for 2 years post-operatively. Electronic patient records and X-rays were reviewed for all included patients. All X-rays were examined by each team member twice, with a time interval of two weeks to improve inter-observer reliability. 65 patients were included with 2:1 female to male ratio and average age of 72 years. 36 patients sustained displaced fractures and 29 undisplaced. Ten patients sustained a high-energy injury, none of which developed AVN. Average time to surgery was 40 hours and 57 patients mobilised on day one post-operatively. All cases used either 7 or 7.3mm partially threaded screws in the following configurations: 2 in triangle apex superior, 39 triangle apex inferior, 22 rhomboid and 2 other, with 9 cases using washers. All reductions were performed closed. Five (8%) of our patients were lost to follow-up as they moved out of area, 48 (74%) had no surgical complications, seven (11%) had mild complications, three (5%) moderate and two (3%) developed AVN. Both of these sustained displaced fractures with low mechanism of injury, were female, ASA 2 and both ex-smokers. One received three screws in apex inferior configuration and one rhomboid, neither fixed with washers. Our AVN rate following intracapsular hip fracture fixation with cannulated screws is much lower than widely accepted. This study is under-powered to comment on factors which may contribute to the development of AVN. However, we can confidently say that our practice has led to low rates of AVN. This may be due to our method of fixation; we use three screws in an apex inferior triangle or four screws in a rhomboid, our consultant-led operations, closed reduction of all fractures, or our operative technique. We pass a short thread cannulated screw across the least comminuted aspect of the fracture first in order to achieve compression, followed by two or three more screws (depending on individual anatomy) to form a stable construct. Our series shows that fixation of intracapsular hip fractures with cannulated screws as we have outlined remains an excellent option. Patients retain their native hip, have a low rate of AVN, and avoid the risks of open reduction


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 70 - 70
1 Dec 2021
McCabe-Robinson O Nesbitt P
Full Access

Abstract

Introduction

Bipolar hemiarthroplasty(BPHA) for displaced intracapsular neck of femur fractures(DICNOF) is a controversial topic as conflicting evidence exists. The most common reason for revision to total hip arthroplasty(THA) from BPHA is acetabular erosion. In our study, we sought to quantify the direction of migration of the bipolar head within the first 3 years post-operatively.

Methods

A proportional index in the horizontal and vertical planes of the pelvis were used to quantify migration. This method removed the need to account for magnification and rotation of the radiographs.


Abstract. Objectives. Hip instability following total hip arthroplasty in treatment of intracapsular neck of femur fractures is reported at 8–11%. Utilising the principle of a small articulation to minimize the problems of wear coupled with a large articulation, dual-mobility total hip arthroplasty prostheses stabilise the hip further than conventional fixed-bearing designs. The aim of this study is to compare the rate of dislocation and complication between standard fixed-bearing and dual-mobility prostheses for the treatment of intracapsular neck of femur fractures. Methods. A four-year retrospective review in a large district general hospital was completed. All cases of intracapsular neck of femur fractures treated with total hip arthroplasty were identified through the theatre logbooks. Patient's operative and clinical notes were retrospectively reviewed to collect data. Results. A total of 91 patients underwent total hip arthroplasty for intracapsular neck of femur fracture in the four-year period. 61.5% were dual-mobility design versus 28.5% had fixed-bearing implants. There were no statistical differences between patient group characteristics. Choice of implant was dependent on surgeon preference. There was a 0.0% dislocation rate in the dual-mobility group versus 8.6% in the fixed-bearing prosthesis group. All dislocations occurred in patients who underwent total hip arthroplasty with 36.0mm fixed-bearing prosthesis via posterior surgical approach. There was no statistical difference in mortality between both groups. Conclusion. There was an increasing trend of towards the use of dual-mobility prosthesis for fractured neck of femur within this department with excellent outcomes. Dual-mobility designs provide reduced dislocation rates in total hip arthroplasty in intracapsular neck of femur fractures compared to standard fixed-bearing designs at this institution. The authors recommend that all orthopaedic staff consider the use of dual-mobility prostheses in suitable patients and ensure trainees are suitably trained in use of dual-mobility designs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 28 - 28
1 May 2017
Woods S Vidakovic I Alloush A Mayahi R
Full Access

Background. Intracapsular neck of femur fractures are one of the most common injuries seen in Orthopaedics. When the fracture is amenable to internal fixation there are 2 main treatment options, namely multiple cannulated hip screws (MCS) and 2-hole sliding hip screws (SHS). In this retrospective study we examine the outcomes associated with these two methods of internal fixation. At present there is little consensus regarding which treatment should be used. Methods. 161 patients were found to have suffered intracapsular neck of femur fracture treated with either SHS or MCS fixation over a 5 year period from April 2009 to April 2014, allowing at least 1 year follow up following injury. The patients imaging and clinical notes were then reviewed to ascertain the outcome of their treatment and any complications. Results. 93 patients were treated with a sliding hip screw compared to 68 that had been treated with cannulated screws. To ensure the fractures in each group were comparable in terms of fracture severity they were classified using gardens and pauwels score. The mean age of the group treated with SHS was 75.15 years, 7.69 years higher than those treated with MCS. The mean length of inpatient stay was 4.7 days longer for patients treated with sliding hip screws than those treated with cannulated screws, which is significantly more than would be predicted by age difference alone. Further patients were excluded for analysis of failure rate if they had not been sufficiently followed up, leaving 122 patients, 58 treated with MCS and 64 with SHS. A significantly higher (p=0.0136) proportion of patients treated with SHS (32%) suffered failure of their fixation compared to those treated with MCS (10%). The SHS group was further classified by whether or not a permanent derotation screw was employed. The use of a derotation screw provided protection against failure with a number needed to treat of 3.82, decreasing the failure rate to 14% which was not significantly more than the failure rate for MCS. Conclusions. We recommend that the first choice treatment for intracapsular neck of femur fractures amenable to internal fixation should be cannulated screws due to a lower rate of failure and shorter length of inpatient stay. If a surgeon has a strong preference for sliding hip screw we strongly recommend inserting a permanent derotation screw


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 65 - 65
1 Nov 2021
Awadallah M Ong J Kumar N Rajata P Parker M
Full Access

Introduction and Objective. Dislocation of a hip hemiarthroplasty is a significant complication with a high mortality rate in elderly patients. Previous studies have shown a higher risk of dislocation in patients with neuromuscular conditions. In this study, we reviewed our larger cohort of patients to identify if there is a link between neuromuscular disorders and dislocation of hip hemiarthroplasty in patients with neuromuscular conditions. Materials and Methods. We have retrospectively analysed a single-centre data that was collected over 34 years for patients with intracapsular neck of femur fracture who underwent hip hemiarthroplasty. The study population was composed of four groups: patients with no neuromuscular disorders, patients with Parkinson's disease, patients with previous stroke, and patients with mental impairment. Results. A total of 3827 patients were included in the analysis. 3371 patients had no neuromuscular condition (Group I) with a dislocation rate of 1.1%. 219 patients had Parkinsonism (Group II) with a dislocation rate of 3.2%, 104 patients had a previous stroke with weakness on the fracture side with a dislocation rate of 1.0% (Group III), and 984 patients had severe mental impairment with a dislocation rate of 1.8% (Group IV). The increased dislocation rate for those with Parkinson's disease was statistically significant (p=0.02) while none of the other neuromuscular conditions were statistically significant. Conclusions. Our study has shown an increased risk of dislocation of hemiarthroplasty in patients with Parkinson's disease in comparison to other groups. No increase was apparent for patients with mental impairment or weakness from a previous stroke


Bone & Joint 360
Vol. 12, Issue 6 | Pages 49 - 51
1 Dec 2023
Burden EG Whitehouse MR Evans JT


Bone & Joint 360
Vol. 10, Issue 6 | Pages 48 - 50
1 Dec 2021
Evans JT French JMR Whitehouse MR