Introduction. An important factor in the internal fixation of pertrochanteric fractures is the ability to maintain postoperative reduction. Excessive postoperative sliding of the lag screw or blade may result in reduction loss. We retrospectively analyzed the relationship between postoperative reduction and sliding. Methodology. From Oct. 2009 to Sept. 2011, we treated pertrochanteric fractures using J-PFNA (Synthes) and InterTAN (Smith & Nephew) in 91 cases and 82 cases, respectively. We used postoperative radiographs to classify its reduction. Fractures were classified for its interfragmentary contact using the calcar femorale as a reference on the A-P plane while using the anterior cortex as a reference on the M-L plane. Results. PFNA cases showed greater postoperative sliding than InterTAN cases. Both demonstrated greater sliding when the proximal fragment was positioned inside the medullary canal on the M-L plane than when positioned outside or anatomically. Conclusion. Although the InterTAN can maintain greater
Introduction. Although femoral neck fractures remain a concern in short term failures for hip resurfacing, acetabular component position and fixation are increasingly being recognized as causes of mid term failures for hip resurfacing. This study aimed to evaluate the migration pattern of a cobalt chrome, beaded acetabular component for a metal on metal hip resurfacing. Methods. 130 patients underwent metal on metal hip resurfacing: 66 hips in 60 patients had sufficient films to be included in this analysis. Forty-eight patients were male and 12 were female, with a mean age of 50 (range, 32–66). Ninety-five percent of the procedures were performed for osteoarthritis. In all cases acetabular migration was measured both vertically and horizontally, on serial radiographs using the computer-assisted Ein Bild Röntgen Analyse method. A minimum of three comparable radiographs is necessary for calculating the migration curves. We scored medial migration as negative horizontal movement. Results. At a mean follow up 25.3 months (24–36 months), each hip had an average of 5.1 radiographs for analysis. 12.5% of the cups showed more than 1 mm migration in the medial-lateral axis and 45.3% more than 1 mm in the vertical axis. 23% of the cups showed a combined migration of greater than 2 mm in the observation period. Two of these cases required revision for aseptic loosening at 34 months. Discussion and Conclusion. Previous studies have shown EBRA to have an excellent sensitivity and positive predictive value for mid to long term cup failure. This data raises concern about the
Objectives. The additive use of an external modular device may improve dorsal compression forces in pelvic external fixation. This would improve the efficiency of indirect reduction and stabilization with an anterior pelvic external fixator. The purpose of this study was to determine the forces of the posterior pelvis achieved by a new device improving the application of a supraacetabular anterior external fixator compared with other constructs. Material and Method. Synthetic pelvic models were used. Complete pelvic ring instability was created by symphyseal and unilateral sacroiliac joint disruption. Four different constructs of fixation were tested. A pressure-sensitive film was placed in the sacroiliac joint. The constructs were applied in a standardized way. The maximum sacroiliacal compression loads (N) of each trial was recorded. Statistics was performed with the student t-test. Results. Standard supraacetabular two-pin external fixator achieved a dorsal compression load of 13.84 (SD 8.13). The new dorsal pelvic compression device delivered 177.05N (SD 32.32) of load across the sacroiliac joint when the pins were inserted half way and 183.58N (SD 46.64) with full pin insertion. Both the half- and full-pin construct demonstrated a significant dorsal load improvement with the pelvic compressor (p<0.05) compared with the standard supraacetabular fixator group. The C-clamp revealed compression forces of 384.88N (SD 22.95), which was significantly greater than all the other groups (p<0.05). Conclusion. We tested a simple and new modular device for improved application of pelvic external fixation. The centres of rotation of supra-acetabular pins were determined and used to achieve greater dorsal compression forces in disrupted pelvic ring injuries. The compression load is less than with a C-Clamp, but significantly greater than the familiar technique of standard external supra-acetabular fixation. This improves the
Introduction. Modern cementless press fit stems rely on early fixation and stability for osteointegration and longterm success with early migration increasing the risk of failure. The Ein Bild Roentegen Analyse Femoral Component Analysis (EBRA-FCA) methods allow accurate measurement of femoral stem subsidence without the need for Tantalum markers. The degree of subsidence of femoral stems in the first two years has been shown to be highly predictive of failure when using the cut off value of 1.5 mm. We aimed to measure the early migration pattern of a titanium alloy, tapered, plasma and hydroxyapatite coated femoral stem and any factors associated with subsidence. Methods. Between January 2005-June 2007, 387 Accolade cementless femoral stems (Stryker, Allendale NJ) were implanted at our institution. Seventy-seven had a minimum of two years post operative follow up and a complete set of pre and postoperative radiographs for analysis. Our group inlcuded 45 females with a mean age of 71.4 years, and 32 males with a mean age of 68.5 years. The primary diagnosis was degenerative osteoarthritis in 71 patients, avascular necrosis in two, and post fracture in four patients. The average BMI was 27.1. We measured the canal index to assess bone quality and the canal calcar index to assess the proximal femoral morphology. Immediate postoperative radiographs were assessed for canal fill of the prosthesis and implantation varus/valgus angles. The EBRA-FCA software was used to obtain migration curves for each stem. Results. The mean follow up was 29.3months (24–48). The mean canal index was 0.55 (0.36–0.68) with a mean canal calcar index of 0.54 (0.39–0.79). The average canal fill index at the midpoint of the stem was <0.8 in 37 stems and >80 in 40 stems. The average subsidence at 24 months was 2 mm and this had risen to 2.4 mm by 36 months postoperatively. When analysed using a Kaplan Meier curve using 1.5 mm as an end point we found a survivorship of 63.4% (52.3–74.5) at 24 months and this had worsened to 41.6% (26.6–56.5) by 36 months. Multivariate and univariate regression analysis of measured variables did not reveal any significant hazard for any factor other than the larger stem sizes doing worse. Discussion. Although several cementless tapered stem designs have had an excellent track record, our migration analysis of the Accolade stem is somewhat concerning. Thirty three percent of stems had reached the 1.5 mm subsidence point by two years. This is of concern as work has previously shown this to predict failure of stems with aseptic loosening at ten years with an accuracy of 79%. If these stems go on to fail at the predicted rate this would represent an unacceptably high level of failure. Our data raises serious concerns about the overall clinical performance of this stem design due to poor
The monitoring of fracture healing is a complex process. Typically, successive radiographs are performed and an emerging calcification of the fracture area is evaluated. The aim of this study was to investigate whether different bone healing patterns can be distinguished using a telemetric instrumented femoral internal plate fixator. An electronic telemetric system was developed to assess bone healing mechanically. The system consists of a telemetry module which is applied to an internal locking plate fixator, an external reader device, a sensor for measuring externally applied load and a laptop computer with processing software. By correlation between externally applied load and load measured in the implant, the elasticity of the osteosynthesis is calculated. The elasticity decreases with ongoing consolidation of a fracture or nonunion and is an appropriate parameter for the course of bone healing. At our centre, clinical application has been performed in 56 patients suffering nonunion or fracture of the femur.Objectives
Materials and Methods
Between 2000 and 2006 we performed salvage tibiotalar arthrodesis in 17 diabetic patients (17 ankles) with grossly unstable ankles caused by bimalleolar fractures complicated by Charcot neuro-arthropathy. There were ten women and seven men with a mean age of 61.6 years (57 to 69). A crossed-screw technique was used. Two screws were used in eight patients and three screws in nine. Additional graft from the malleoli was used in all patients. The mean follow-up was 26 months (12 to 48) and the mean time to union was 5.8 months (4 to 8). A stable ankle was achieved in 14 patients (82.4%), nine of whom had bony fusion and five had a stiff fibrous union. The results were significantly better in underweight patients, in those in whom surgery had been performed three to six months after the onset of acute Charcot arthropathy, in those who had received anti-resorptive medication during the acute stage, in those without extensive peripheral neuropathy, and in those with adequate peripheral oxygen saturation (>
95%). The arthrodesis failed because of avascular necrosis of the talus in only three patients (17.6%), who developed grossly unstable, ulcerated hindfeet, and required below-knee amputation.