Advertisement for orthosearch.org.uk
Results 1 - 20 of 49
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 91 - 96
1 Jun 2019
Smith A Denehy K Ong KL Lau E Hagan D Malkani A

Aims. Cephalomedullary nails (CMNs) are commonly used for the treatment of intertrochanteric hip fractures. Total hip arthroplasty (THA) may be used as a salvage procedure when fixation fails in these patients. The aim of this study was to analyze the complications of THA following failed intertrochanteric hip fracture fixation using a CMN. Patients and Methods. Patients who underwent THA were identified from the 5% subset of Medicare Parts A/B between 2002 and 2015. A subgroup involving those with an intertrochanteric fracture that was treated using a CMN during the previous five years was identified and compared with the remaining patients who underwent THA. The length of stay (LOS) was compared using both univariate and multivariate analysis. The incidence of infection, dislocation, revision, and re-admission was compared between the two groups, using multivariate analysis adjusted for demographic, hospital, and clinical factors. Results. The Medicare data yielded 56 522 patients who underwent primary THA, of whom 369 had previously been treated with a CMN. The percentage of THAs that were undertaken between 2002 and 2005 in patients who had previously been treated with a CMN (0.346%) more than doubled between 2012 and 2015 (0.781%). The CMN group tended to be older and female, and to have a higher Charlson Comorbidity Index and lower socioeconomic status. The mean LOS was 1.5 days longer (5.3 vs 3.8) in the CMN group (p < 0.0001). The incidence of complications was significantly higher in the CMN group compared with the non-CMN group: infection (6.2% vs 2.6%), dislocation (8.1% vs 4.5%), revision (8.4% vs 4.3%), revision for infection (1.1% vs 0.37%), and revision for dislocation (2.2% vs 0.6%). Conclusion. The incidence of conversion to THA following failed intertrochanteric hip fracture fixation using a CMN continues to increase. This occurs in elderly patients with increased comorbidities. There is a significantly increased risk of infection, dislocation, and LOS in these patients. Patients with failed intertrochanteric hip fracture fixation using a CMN who require THA should be made aware of the increased risk of complications, and steps need to be taken to reduce this risk. Cite this article: Bone Joint J 2019;101-B(6 Supple B):91–96


Bone & Joint Research
Vol. 6, Issue 5 | Pages 270 - 276
1 May 2017
Gosiewski JD Holsgrove TP Gill HS

Objectives. Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Methods. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm. 3. , 0.16 g/cm. 3. and 0.24 g/cm. 3. ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. Results. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm. 3. polyurethane foam). In 0.08 g/cm. 3. density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm. 3. density bone substitute. Conclusions. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article: J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation. Bone Joint Res 2017;6:270–276. DOI: 10.1302/2046-3758.65.BJR-2017-0287.R1


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 47 - 47
1 Mar 2008
Vasarhelyi T Long W Mayman D Rudan J Pichora D Ellis R
Full Access

A fluoroscopic based computer enhancement system was designed for accurate insertion of guide wires for hip fracture fixation while decreasing fluoroscopy time. A saw bone model was created. The femur was imaged with fluoroscopy and a three-dimensional computer model was created. The femur, fluoroscopy drum, and drill were tracked with an optical tracking device. Guide wire position was planned on the computer model. Using a tracked drill the guide wire was inserted. The number of fluoroscopic images was decreased by 85% and the number of passes required to place the guide wire in acceptable position was decreased by 60% using computer enhanced technique. A fluoroscopic based computer enhancement system was designed for accurate insertion of guide wires for hip fracture fixation while decreasing fluoroscopy time. The number of fluoroscopic images and passes required to place the guide wire in acceptable position were decreased using computer enhanced technique. Final guide wire position was not different between the two groups. Orthopedic surgeons are exposed to radiation from fluoroscopy on a daily basis. This system allowed us to insert guide wires using substantially less fluoroscopy, without compromising accuracy. An average of 13.5 images were taken for each standard technique trial compared to two images for each computer enhanced trial, representing a reduction in fluoroscopy of 85%. One pass was used for each computer enhanced trial. An average of 2.4 trials was used for standard technique. Average final error was 3.6mm using standard technique and 3.8mm using computer technique. A saw bone model with a soft tissue sleeve was created. A DRB (dynamic referencing body) was fixed to the femur. The DRB, fluoroscopy drum, and drill were tracked with an optical tracking device. The system created a 3D model from two orthogonal fluoroscopic images. Guide wire position was then planned on the computer model. Using a tracked drill the guide wire was inserted. Computer enhanced trials were compared to standard techniques in regards to number of fluoroscopic images taken, number of trials to obtain acceptable guide wire position, and accuracy of guide wire placement. Guide wire position was measured on AP and lateral x-rays. Funding: This project was funded in part through a grant from the Canadian Foundation for Innovation


Bone & Joint Open
Vol. 4, Issue 8 | Pages 602 - 611
21 Aug 2023
James HK Pattison GTR Griffin J Fisher JD Griffin DR

Aims. To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. Methods. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty). Results. Eight female (29%) and 20 male trainees (71%), mean age 29.4 years, performed 317 DHS operations and 243 hemiarthroplasties during ten months of follow-up. Primary analysis was a random effect model with surgeon-level fixed effects of patient condition, patient age, and surgeon experience, with a random intercept for surgeon. Under the intention-to-treat principle, for hemiarthroplasty there was better implant position in favour of cadaveric training, measured by leg length discrepancy ≤ 10 mm (odds ratio (OR) 4.08 (95% confidence interval (CI) 1.17 to 14.22); p = 0.027). There were significantly fewer postoperative blood transfusions required in patients undergoing hemiarthroplasty by cadaveric-trained compared to standard-trained surgeons (OR 6.00 (95% CI 1.83 to 19.69); p = 0.003). For DHS, there was no significant between-group difference in implant position as measured by tip-apex distance ≤ 25 mm (OR 6.47 (95% CI 0.97 to 43.05); p = 0.053). No between-group differences were observed for any secondary clinical outcomes. Conclusion. Trainees randomized to additional cadaveric training performed hip fracture fixation with better implant positioning and fewer postoperative blood transfusions in hemiarthroplasty. This effect, which was previously unknown, may be a consequence of the intervention. Further study is required. Cite this article: Bone Jt Open 2023;4(8):602–611


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_18 | Pages 3 - 3
1 Apr 2013
Bradford OJ Niematallah I Berstock JR Trezies A
Full Access

Intra-operative Tip-Apex Distance (TAD) estimation optimises dynamic hip screw (DHS) placement during hip fracture fixation, reducing risk of cut-out. Thread-width of a standard DHS screw measures approximately 12.5 millimetres. We assessed the effect of introducing screw thread-width as an intra-operative distance reference to surgeons. The null hypothesis was that there were no differences between hip fracture fixation before and after this intervention. Primary outcome measure was TAD. Secondary outcome measures included position of the screw in the femoral head, quality of reduction, cut-out and surgeon accuracy of estimating TAD. 150 intra-operative DHS radiographs were assessed before and after introducing screw thread-width distance reference to surgeons. Mean TAD reduced from 19.37mm in the control group to 16.49mm in the prospective group (p=<0.001). The number of DHS with a TAD > 25mm reduced from 14% to 6%. Screw position on lateral radiographs was significantly improved (p=0.004). There were no significant differences in screw position on antero-posterior radiographs, quality of reduction, or rate of cut-out. Significant improvement in accuracy (p=0.05) and precision (p=0.005) of TAD estimation was demonstrated. Awareness and use of screw-thread width improves estimation and positioning of a DHS screw in the femoral head during fixation of hip fractures


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 551 - 552
1 Oct 2010
Khunda A Hui A Rookmoneea M
Full Access

Aim: To compare the acute haemoglobin level drop following hip fracture fixation with IMHS and CHS at James Cook University Hospital and assess whether the surgeon’s seniority has any effect on the amount of blood loss in these two procedures. Methods: Trauma data base was searched for all IMHS procedures performed from January 2002 till March 2007 both included and CHS procedures performed from January 2007 till March 2008 both included. There were 159 CHS procedures and 146 IMHS procedures. 137 CHS and 123 IMHS procedures fulfilled the blood testing and transfusion criteria. Haemoglobin levels were used as an indication for blood loss attributable to surgery. The difference between the last level of haemoglobin checked preoperatively and the first post operative level performed between 12–48 hours postoperatively is calculated. Cases where blood transfusion was carried out preoperatively without further preoperative haemoglobin check were excluded, so were cases receiving intra or post operative blood transfusion prior to the defined postoperative haemoglobin check was carried out. Results: SPSS 13.0 statistical package was used to analyse the results. Levene’s test proved equality of variances of blood loss within the two groups of patients undergoing one of the two procedures, P=0.5. Hence, Independent Samples T test was applicable and showed that patients undergoing an IMHS procedure dropped their haemoglobin levels by 2.96 g/dl. While, those undergoing a CHS procedure dropped their haemoglobin levels by 2.32 g/dl. The 0.64 g/dl difference in haemoglobin drop was statistically significant at 5% significance level with 95% CI (0.27 to 1.01), P=0.001. The surgeons’ grades were classified into three groups as: Consultants, Registrars and Senior House Officers. Levene’s test again proved the variances of haemoglobin drop within each group to be homogeneous. Hence a One-Way ANOVA test was carried out showing that the differences in haemoglobin drop were not statistically significant when comparing the three groups of surgeons to each other. This was true for both IMHS and CHS procedures. Conclusion: Patients undergoing a CHS procedure drop their haemoglobin levels by 0.64 g/dl less than those undergoing an IMHS procedure. The surgeon’s seniority does not make difference to the amount of haemoglobin level drop following either of the two procedures. We recommend the use of CHS for stable fractures and reserve the IMHS for the unstable ones due to the increased blood loss with IMHS procedures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 34 - 34
1 Sep 2012
Singisetti K Mereddy P Cooke N
Full Access

Introduction

Internal fixation of pertrochanteric fractures is evolving as newer implants are being developed. Proximal Femoral Nail Antirotation (PFNA) is a recently introduced implant from AO/ASIF designed to compact the cancellous bone and may be particularly useful in unstable and osteoporotic hip fractures. This study is a single and independent centre experience of this implant used in management of acute hip fractures.

Methods

68 patients involving 68 PFNA nailing procedures done over a period of 2 years (2007–09) were included in the study. Average follow-up period of patients was 1 year. AO classification for trochanteric fractures was used to classify all the fractures. Radiological parameters including tip-apex distance and neck shaft angle measurement were assessed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 55 - 55
11 Apr 2023
Raina D Markeviciute V Arvidsson L Törnquist E Stravinskas M Kok J Jacobson I Liu Y Tengattini A Sezgin E Vater C Zwingenberger S Isaksson H Tägil M Tarasevicius S Lidgren L
Full Access

Majority of osteoporosis related fractures are treated surgically using metallic fixation devices. Anchorage of fixation devices is sometimes challenging due to poor osteoporotic bone quality that can lead to failure of the fracture fixation. Using a rat osteoporosis model, we employed neutron tomography and histology to study the biological effects of implant augmentation using an isothermally setting calcium sulphate/hydroxyapatite (CaS/HA) biomaterial with synthetic HA particles as recruiting moiety for systemically administered bisphosphonates. Using an osteoporotic sawbones model, we then provide a standardized method for the delivery of the CaS/HA biomaterial at the bone-implant interface for improved mechanical anchorage of a lag-screw commonly used for hip fracture fixation. As a proof-of-concept, the method was then verified in donated femoral heads and in patients with osteoporosis undergoing hip fracture fixation. We show that placing HA particles around a stainless-steel screw in-vivo, systemically administered bisphosphonates could be targeted towards the implant, yielding significantly higher peri-implant bone formation compared to un-augmented controls. In the sawbones model, CaS/HA based lag-screw augmentation led to significant increase (up to 4 times) in peak extraction force with CaS/HA performing at par with PMMA. Micro-CT imaging of the CaS/HA augmented lag-screws in cadaver femoral heads verified that the entire length of the lag-screw threads and the surrounding bone was covered with the CaS/HA material. X-ray images from fracture fixation surgery indicated that the CaS/HA material could be applied at the lag-screw-bone interface without exerting any additional pressure or risk of venous vascular leakage.: We present a new method for augmentation of lag-screws in fragile bone. It is envisaged that this methodcould potentially reduce the risk of fracture fixation failure especially when HA seeking “bone active” drugs are used systemically


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 145 - 145
11 Apr 2023
Mariscal G Jover N Balfagón A Barrés M
Full Access

Solid organ transplant (SOT) recipients present an increased medical risk; however, few studies analyze the outcomes of these patients undergoing hip fracture surgery. This study aimes to determine the incidence of hip fracture in SOT patients and to compare the outcomes of SOT patients with matched non-SOT controls after hip fracture fixation. A retrospective review identified 20 SOT patients with hip fracture at a single center from 2016 to 2021 and were matched (1:1) with a cohort of 20 patients with hip fracture without SOT. Patient outcomes, mortality/survival and clinical outcomes were compared between two groups. The incidence of hip fracture in SOT patients was 20/1787, 1.1%. There were significant differences in mortality rate (73.3% SOT group vs. 26.7% non-SOT group; p<0.05). There were no differences in survival time (p=0.746). There were no differences in time to surgery (5.0 days SOT group vs. 3.1 days non-SOT group; p=0.109), however, there were significant differences in the hospital length of stay (14 days SOT group vs. 8.6 days non-SOT group; p=0.018). There were no differences regarding the complication rate between the two groups (9/20, 45% vs. 6/20, 30% in the SOT and non-SOT groups, respectively). SOT patients with associated hip fracture required longer hospital length of stay than non-SOT patients. SOT patients did not show greater clinical complications; however, they presented higher mortality rate compared to non-SOT patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 13 - 13
7 Jun 2023
Diffley T Ferry J Sumarlie R Beshr M Chen B Clement N Farrow L
Full Access

Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering hip fracture fixation strategies. A retrospective cohort study using Scottish hip fracture audit (SHFA) data was performed for the period 2016–2022. Patients ≥50 with a hip fracture and treated with IMN or SHS constructs at Scottish Hospitals were included. Comparative analyses, including adjustment for confounders, were performed utilising Multivariable logistic regression for dichotomous outcomes and Mann-Whitney-U tests for non-parametric data. A sub-group analysis was also performed focusing on AO-A1/A2 configurations which utilised additional regional data. Cost differences in Length of Stay (LOS) were calculated using defined costs from the NHS Scotland Costs book. In all analyses p<0.05 denoted significance. 13638 records were included (72% female). 9867 received a SHS (72%). No significant differences were identified in 30 or 60-day survival (Odds Ratio [OR] 1.05, 95%CI 0.90–1.23; p=0.532), (OR 1.10, 95%CI 0.97–1.24; p=0.138) between SHS and IMN's. There was however a significantly lower early mobilisation rate with IMN vs SHS (OR 0.64, 95%CI 0.59–0.70; p<0.001), and lower likelihood of discharge to domicile by day-30 post-admission (OR 0.77, 95%CI 0.71–0.84; p<0.001). Acute and overall, LOS were significantly lower for SHS vs IMN (11 vs 12 days and 20 vs 24 days respectively; p<0.001). Findings were similar across a sub-group analysis of 559 AO A1/A2 fracture configurations. Differences in LOS potentially increases costs by £1230 per-patient, irrespective of the higher costs of IMN's v SHS. Appropriate SHS use is associated with early mobilisation, reduced LOS and likely with reduced cost of treatment. Further research exploring potential reasons for the identified differences in early mobilisation are warranted


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 32 - 32
1 Nov 2021
Huo M
Full Access

Thru purpose of this study was to evaluate the clinical outcomes of a consecutive series of conversion total hip arthroplasty (cTHA) following previous hip fractures. A retrospective chart review of patients who underwent cTHAs from 2008–2017 at an urban academic teaching institution was performed. Eighty-eight patients were included in this study. The mean age at the cTHA was 66 years (range 27 to 89). 67% of the patients wre women. The mean BMI was 28 kg/m. 2. (range 17 to 41). The mean Charlson Comorbidity Index was 3 (range 0 to 9). The mean follow-up was 49 months (range 24 to 131). The mean duration from the hip fracture fixation to the cTHA was 51 months (range 10 to 144). The mean operating time was 188 minutes, (range 71 to 423) with a mean estimated blood loss of 780 ml (range 300 to 2500). Revision-type (long-stem) designs were used in 65% of the cases. The mean length of hospital stay was 8 days (range 2 to 61). The readmission rate was 37% within 90 days after the CTHAs. Of these, 57% were due to non-orthopaedic complications. There were 10 orthopaedic complications: 7 PJIs, all of which required I&D and 3 required staged revision. There were 2 dislocations treated with closed reduction and 1 case of intraoperative periprosthetic femur fracture during femoral component insertion. There was no revision for aseptic loosening within the follow-up period. The one-year mortality rate was 0%. cTHAs were associated with longer operating time, more blood loss, longer length of hospital stay, and higher readmission rates than the primary THAs in our institutional database. We believe utilizing a multi-disciplinary care protocol to optimize these patients is needed to reduce the high rate of readmissions, and the complications in this patient population


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 84 - 84
19 Aug 2024
Cordero-Ampuero J
Full Access

Debate continues about the best treatment for patients over 65 years with non-displaced subcapital hip fractures: internal fixation (IF) or hemiarthroplasty (HA). Surgical aggression, mortality, complications and recovery of walking ability after 1year have been compared between both treatments. Match-paired comparison of 2 retrospective cohorts. 220 patients with IF vs 220 receiving a cemented bipolar HA. Matching by age (82.6±7.16 years (65–99)), sex (74.5% women), year of intervention (2013–2021) and ASA scale (24.2% ASA II, 55.8% III, 20.0% IV). Age (p=0.172), sex (p=0.912), year of intervention (p=0.638) and ASA scale (p=0.726) showed no differences. Surgical aggression smaller in IF: Surgical time (p< 0,00001), haemoglobin/haematocrit loss (p <0,00001), need for transfusion (p<0,00008), in-hospital stay (p<0,00001). Mortality: higher in-hospital for hemiarthroplasties (12 deaths (5.5%) vs 1 (0.5%) (p=0.004) (RR=12, 1.5–91.5)). But no significant differences in 1-month (13 hemiarthroplasties, 6%, vs 9 osteosynthesis, 4.1%) and 1-year mortality (33 hemiarthroplasties, 15%, vs 35, 16%). Medical complications: no differences in urinary/respiratory infections, heart failure, ictus, myocardial infarction, digestive bleeding, pressure sores or pulmonary embolus (p=0.055). Surgical complications: no significant differences. HA: 6 intraoperative (2,7%) and 5 postoperative periprosthetic fractures (2,3%), 5 infections (2,3%), 10 dislocations (4,5%), 3 neurovascular injuries. IF: 10 acute fixation failures (4,5%), 2 infections (0,9%), 9 non-unions (4,1%), 16 ischemic necrosis (7,3%). Functional results: no significant differences; 12 patients in each group (5,5%) never walked again (p=1), 110 HA (50%) and 100 IF (45.5%) suffered worsening of previous walking ability (p=0.575), 98 HA (44%) and 108 IF patients (49%) returned to pre-fracture walking ability (p=0.339). Fixation with cannulated screws may be a better option for non-displaced femoral neck fractures because recovery of walking ability and complications are similar, while surgical aggression and in-hospital mortality are lower


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 35 - 35
1 Dec 2020
Scattergood SD Berry AL Flannery O Fletcher JWA Mitchell SR
Full Access

Intracapsular neck of femur fractures may be treated with fixation or arthroplasty, depending on fracture characteristics and patient factors. Two common methods of fixation are the sliding hip screw, with or without a de-rotation screw, and cannulated screws. Each has its merits, and to date there is controversy around which method is superior, with either method thought to risk avascular necrosis of the femoral head (AVN) rates in the region of 10–20%. Fixation with cannulated screws may be performed in various ways, with current paucity of evidence to show an optimum technique. There are a multitude of factors which are likely to affect patient outcomes: technique, screw configuration, fracture characteristics and patient factors. We present a retrospective case series analysis of 65 patients who underwent cannulated screw fixation of a hip fracture. Electronic operative records were searched from July 2014 until July 2019 for all patients with a neck of femur fracture fixed with cannulated screws: 68 were found. Three patients were excluded on the basis of them having a pathological fracture secondary to malignancy, cases were followed up for 2 years post-operatively. Electronic patient records and X-rays were reviewed for all included patients. All X-rays were examined by each team member twice, with a time interval of two weeks to improve inter-observer reliability. 65 patients were included with 2:1 female to male ratio and average age of 72 years. 36 patients sustained displaced fractures and 29 undisplaced. Ten patients sustained a high-energy injury, none of which developed AVN. Average time to surgery was 40 hours and 57 patients mobilised on day one post-operatively. All cases used either 7 or 7.3mm partially threaded screws in the following configurations: 2 in triangle apex superior, 39 triangle apex inferior, 22 rhomboid and 2 other, with 9 cases using washers. All reductions were performed closed. Five (8%) of our patients were lost to follow-up as they moved out of area, 48 (74%) had no surgical complications, seven (11%) had mild complications, three (5%) moderate and two (3%) developed AVN. Both of these sustained displaced fractures with low mechanism of injury, were female, ASA 2 and both ex-smokers. One received three screws in apex inferior configuration and one rhomboid, neither fixed with washers. Our AVN rate following intracapsular hip fracture fixation with cannulated screws is much lower than widely accepted. This study is under-powered to comment on factors which may contribute to the development of AVN. However, we can confidently say that our practice has led to low rates of AVN. This may be due to our method of fixation; we use three screws in an apex inferior triangle or four screws in a rhomboid, our consultant-led operations, closed reduction of all fractures, or our operative technique. We pass a short thread cannulated screw across the least comminuted aspect of the fracture first in order to achieve compression, followed by two or three more screws (depending on individual anatomy) to form a stable construct. Our series shows that fixation of intracapsular hip fractures with cannulated screws as we have outlined remains an excellent option. Patients retain their native hip, have a low rate of AVN, and avoid the risks of open reduction


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 430 - 434
1 May 2024
Eardley WGP


Bone & Joint 360
Vol. 11, Issue 5 | Pages 34 - 36
1 Oct 2022


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1266 - 1272
1 Nov 2022
Farrow L Brasnic L Martin C Ward K Adam K Hall AJ Clement ND MacLullich AMJ

Aims

The aim of this study was to examine perioperative blood transfusion practice, and associations with clinical outcomes, in a national cohort of hip fracture patients.

Methods

A retrospective cohort study was undertaken using linked data from the Scottish Hip Fracture Audit and the Scottish National Blood Transfusion Service between May 2016 and December 2020. All patients aged ≥ 50 years admitted to a Scottish hospital with a hip fracture were included. Assessment of the factors independently associated with red blood cell transfusion (RBCT) during admission was performed, alongside determination of the association between RBCT and hip fracture outcomes.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 399 - 407
1 Jun 2023
Yeramosu T Ahmad W Satpathy J Farrar JM Golladay GJ Patel NK

Aims

To identify variables independently associated with same-day discharge (SDD) of patients following revision total knee arthroplasty (rTKA) and to develop machine learning algorithms to predict suitable candidates for outpatient rTKA.

Methods

Data were obtained from the American College of Surgeons National Quality Improvement Programme (ACS-NSQIP) database from the years 2018 to 2020. Patients with elective, unilateral rTKA procedures and a total hospital length of stay between zero and four days were included. Demographic, preoperative, and intraoperative variables were analyzed. A multivariable logistic regression (MLR) model and various machine learning techniques were compared using area under the curve (AUC), calibration, and decision curve analysis. Important and significant variables were identified from the models.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 329 - 337
8 May 2023
Khan AQ Chowdhry M Sherwani MKA McPherson EJ

Aims

Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal femoral neck fractures. However, in many countries this option is economically unviable. To improve outcomes in financially disadvantaged populations, we studied the technique of concomitant valgus hip osteotomy and operative fixation (VOOF). This prospective serial study compares two treatment groups: VOOF versus operative fixation alone with cannulated compression screws (CCSs).

Methods

In the first series, 98 hip fixation procedures were performed using CCS. After fluoroscopic reduction of the fracture, three CCSs were placed. In the second series, 105 VOOF procedures were performed using a closing wedge intertrochanteric osteotomy with a compression lag screw and lateral femoral plate. The alignment goal was to create a modified Pauwel’s fracture angle of 30°. After fluoroscopic reduction of fracture, lag screw was placed to achieve the calculated correction angle, followed by inter-trochanteric osteotomy and placement of barrel plate. Patients were followed for a minimum of two years.


Aims

Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance.

Methods

We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 180 - 189
1 Feb 2023
Tohidi M Mann SM Groome PA

Aims

This study aimed to describe practice variation in the use of total hip arthroplasty (THA) for older patients with femoral neck fracture and to determine the association between patient, surgeon, and institution factors and treatment with THA.

Methods

We performed a cross-sectional analysis of 49,597 patients aged 60 years and older from Ontario, Canada, who underwent hemiarthroplasty or THA for femoral neck fracture between 2002 and 2017. This population-based study used routinely collected healthcare databases linked through ICES (formerly known as the Institute for Clinical Evaluative Sciences). Multilevel logistic regression modelling was used to quantify the association between patient, surgeon, and institution-level variables and whether patients were treated with THA. Variance partition coefficient and median odds ratios were used to estimate the variation attributable to higher-level variables and the magnitude of effect of higher-level variables, respectively.