Advertisement for orthosearch.org.uk
Results 1 - 20 of 3748
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 69 - 69
17 Apr 2023
Day G Jones A Mengoni M Wilcox R
Full Access

Autologous osteochondral grafting has demonstrated positive outcomes for treating articular cartilage defects by replacing the damaged region with a cylindrical graft consisting of bone with a layer of cartilage, taken from a non-loadbearing region of the knee. Despite positive clinical use, factors that cause graft subsidence or poor integration are relatively unknown. The aim of this study was to develop finite element (FE) models of osteochondral grafts within a tibiofemoral joint and to investigate parameters affecting osteochondral graft stability. Initial experimental tests on cadaveric femurs were performed to calibrate the bone properties and graft-bone frictional forces for use in corresponding FE models, generated from µCT scan data. The effects of cartilage defects and osteochondral graft repair were measured by examining contact pressure changes using in vitro tests on a single cadaveric human tibiofemoral joint. Six defects were created in the femoral condyles which were subsequently treated with osteochondral autografts or metal pins. Matching µCT scan-based FE models were created, and the contact patches were compared. Sensitivity to graft bone properties was investigated. The bone material properties and graft-bone frictional forces were successfully calibrated from the initial tests with good resulting levels of agreement (CCC=0.87). The tibiofemoral joint experiment provided a range of cases to model. These cases were well captured experimentally and represented accurately in the FE models. Graft properties relative to host bone had large effects on immediate graft stability despite limited changes to resultant cartilage contact pressure. Model confidence was built through extensive validation and sensitivity testing, and demonstrated that specimen-specific properties were required to accurately represent graft behaviour. The results indicate that graft bone properties affect the immediate stability, which is important for the selection of allografts and design of future synthetic grafts. Acknowledgements. Supported by the EPSRC-EP/P001076


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 124 - 124
1 Dec 2020
CETIN M SOYLEMEZ MS OZTURK BY MUTLU I KARAKUS O
Full Access

Bone-patellar tendon-bone autografts, hamstring autografts or allografts are widely used grafts for ACL revision surgeries. Also use of quadriceps autograft for both primary and revision ACL surgeries is in an increasing popularity due to its biomechanical superior properties and less donor site morbidity. However, although several fixation techniques and devices for quadriceps tendon graft fixation on femoral side have been reported, literature lacks about biomechanical studies comparing properties of these different fixation techniques and devices. We aimed to investigate whether there is a difference between the fixation techniques of quadriceps tendon graft by using different fixation techniques and devices on the femoral side in terms of stiffness and amount of slippage in the tunnel. Full-thickness central parts of quadriceps tendons from paired knees of twenty five calf knees were fixed through a 10mm x 25mm tunnel in twenty five paired sheep femurs. Quadriceps tendon patellar side with soft tissue ending fixed with four different fixation devices (adjustable suspensory system (group 1), absorbable interference screw (group 2), titanium interference screw (group 3) and adjustable suspensory system + absorbable interference screw (group 4)) and quadriceps tendon with a patellar bone plug fixed with a titanium interference screw (group 5) were tested in a servohydraulic materials testing machine. 10 samples were included in each group. After applying a preload of 10 N, a cyclic force was applied for 20 cycles from 10N to 110N at a 1 hertz frequency. Amount of slippage in the tunnel was calculated as the difference measured in millimeters between length at 10 N after 20 cycles and starting length at 10 N (Graph 1). To determine the stiffness, a single load-to-failure cycle was performed at a strain rate of 20 mm/min as the last step (Figure 1). Rupture of the graft was not seen in any of the samples. Median values of amount of slippage in the tunnel were 6,41mm, 5,99mm, 3,01mm, 4,83mm, and 3,94mm respectively. Median values of maximum load at failure were 464N, 160N, 350N, 350N and 389N respectively. Amount of slippage in the tunnel was highest in the group 1 and was lowest in the group 3 (p<0.001). Group 1 was found to be most resistant group against load-to-failure test and group 2 was the weakest (p<0.001). However inter-group analyses between group 3 and 5 revealed that, although group 3 had the least slippage in the tunnel, group 5 was better in terms of stiffness, but there was no statistically significant difference (p=0,124 and 0,119 respectively). There was a significant difference between group 2 and 3 in both amount of slippage in the tunnel and stiffness (p=0,001 and 0.028 respectively)(Table 1). Our study revealed that, although quadriceps graft with a bone plug fixed with metal interference screws is widely presumed to be a stable fixation technique, there was no significant difference in terms of stiffness when compared with quadriceps graft with soft tissue ending fixed with a metal interference screw. Although adjustable suspensory device group was the best in the terms of resistance against load-to-failure, it was the worst in terms of amount of slippage from the tunnel. Thus, if a suspensory device is to be used, it must be kept in mind that a strong 20 cycles of intra-operative tension force must be applied to prevent further slippage of the graft in the tunnel which can result in failure of reconstruction. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 100 - 100
1 Mar 2017
Gabaran N Mirghasemi S Rashidinia S Sadeghi M Talebizadeh M
Full Access

Background. Surgical reconstruction of the anterior cruciate ligament is a common practice to treat the disability or chronic instability of the knee. Several factors associated with success or failure of the ACL reconstruction, including surgical technique and graft material and graft tension. We aimed to show how we can optimize the graft properties and achieve better post surgical outcomes during ACL reconstruction using 3-dimensional computational finite element simulation. Methods. In this paper, 3-dimensional model of the knee was constructed to investigate the effect of graft tensioning on the knee joint biomechanics. Four different grafts were compared: 1) bone-patellar tendon-bone graft (BPTB) 2) Hamstring tendon 3) BPTB and a band of gracilis 4) Hamstring and a band of gracilis. The initial graft tension was set as “0, 20, 40, or 60N”. The anterior loading was set to 134 N. Findings. Our study shows that the use of the discarded gracilis tendon, which usually excised after graft fixation, could be associated with a host of merits. Our results show that preserving this excess part of gracilis would decrease the required pretention load and, subsequently, could optimize biomechanical properties of the knee. Conclusion. Required pretension during surgery will have decreased significantly by adding a band of gracilis to the proper graft. Therefore, in addition to achieving normal stability of the knee, we can have lower risk of degradation


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1567 - 1573
7 Nov 2020
Sambri A Dalla Rosa M Scorianz M Guido D Donati DM Campanacci DA De Paolis M

Aims. The aim of this study was to report the results of three forms of reconstruction for patients with a ditsl tibial bone tumour: an intercalary resection and reconstruction, an osteoarticular reconstruction, and arthrodesis of the ankle. Methods. A total of 73 patients with a median age of 19 years (interquartile range (IQR) 14 to 36) were included in this retrospective, multicentre study. Results. Reconstructions included intercalary resection in 17 patients, osteoarticular reconstruction in 11, and ankle arthrodesis in 45. The median follow-up was 77 months (IQR 35 to 130). Local recurrence occurred in eight patients after a median of 14 months (IQR 9 to 36), without a correlation with adequacy of margins or reconstructive technique. Major complications included fracture of the graft in ten patients, nonunion of the proximal osteotomy in seven, and infection in five. In the osteoarticular group, three of 11 patients developed radiological evidence of severe osteoarthritis, but only one was symptomatic and required conversion to ankle arthrodesis. Functional evaluation showed higher values of the Musculoskeletal Tumour Society (MSTS) and American Orthopaedic Foot and Ankle Society (AOFAS) scores in the intercalary group compared with the others. Conclusion. Preservation of the epiphysis in patients with a distal tibial bone tumour is a safe and effective form of limb-sparing treatment. It requires rigorous preoperative planning after accurate analysis of the imaging. When joint-sparing resection is not indicated, ankle arthrodesis, either isolated tibiotalar or combined tibiotalar and subtalar arthrodesis, should be preferred over osteoarticular reconstruction. Cite this article: Bone Joint J 2020;102-B(11):1567–1573


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 5 - 5
23 Jan 2024
Awad F Khan F McIntyre J Hathaway L Guro R Kotwal R Chandratreya A
Full Access

Introduction. Anterior cruciate ligament (ACL) injuries represent a significant burden of disease to the orthopaedic surgeon and often necessitate surgical reconstruction in the presence of instability. The hamstring graft has traditionally been used to reconstruct the ACL but the quadriceps tendon (QT) graft has gained popularity due to its relatively low donor site morbidity. Methods. This is a single centre comparative retrospective analysis of prospectively collected data of patients who had an ACL reconstruction (either with single tendon quadrupled hamstring graft or soft tissue quadriceps tendon graft). All surgeries were performed by a single surgeon using the All-inside technique. For this study, there were 20 patients in each group. All patients received the same post-operative rehabilitation protocol and were added to the National Ligament Registry to monitor their patient related outcome scores (PROM). Results. The average age of patients in the QT group was 29 years (16 males, 4 females) and in the hamstring group was 28 years (18 males, 2 females). The most common mechanism of injury in both groups was a contact twisting injury. There were no statistical differences between the two patient groups in regards to PROMS and need for further revision surgery as analysed on the National Ligament Registry. Conclusions. The all soft tissue QT graft seems to be equivocal to quadrupled hamstring graft in terms of patient function and recovery graft characteristics. Further research may be needed to elucidate the long-term results of the all soft tissue QT graft given its recent increase in use


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 46 - 46
1 Jul 2022
Soumpasis K Duncan K Wilson AJ Risebury MJ Yasen SK
Full Access

Abstract. Introduction. We present a case series of patients that underwent knee ligament reconstruction with graft reinforcement using FibreTape (Arthrex), a 2mm wide non-biodegradable polyethylene tape. Outcomes and safety of this novel technique are reported. Methods. Data were collected from a prospectively maintained database from 03/2011 to 11/2019. All skeletally mature patients that underwent reinforced knee ligament reconstruction surgery at Basingstoke and North Hampshire Hospital were included. The cohort was interrogated for outcomes including failure, complications, and subjective patient reported outcomes at 6,12 and 24 months postoperatively. Results. 438 patients were eligible. The mean age was 33.4 years and 68% of them were males. This included 171 ACL reconstructions, 96 ACL with anterolatreal ligament reconstructions, 59 bicruciate reconstructions, 30 ACL with posterolateral corner, 49 posterior cruciate ligament with one other ligament and 33 other ligament reconstruction. Allograft was used for 125 patients. 338 cases related to primary reconstruction. The overall complication rate was 5.3%, with a 2.1% re-rupture rate. There were 9 patients with a re-rupture and 5 of them had undergone multiligament reconstruction. We found a statistically significant improvement in all subjective scoring indices post-operatively up to 2 years. There were no complications directly related to the use of ligament reinforcement. Conclusion. Graft reinforcement is a safe option in the management of knee ligament injuries. Encouraging results were observed in patient reported outcomes. Reinforcement is technically reproducible and may represent an answer for graft failure rates, especially in multiligament reconstructions. Further application and evaluation is necessary to confirm its benefit


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 79 - 79
1 Mar 2012
Jneidi M Mahmud H Adra K
Full Access

Purpose of Study. 1- To introduce a new graft technique for ACL reconstruction using the patellar tendon with its attachment on the tibial tuberosity as bone-tendon (B PT) auto graft sparing the patella. 2-To assess the above described technique prospectively in a group of patients with ACL deficient knees. Type of study. Prospective case series of a newly describedACL graft technique. Material and methods. 44 patients with ACL deficient knee (with no other ligament injuries) were recruited to have ACL reconstruction using the above mentioned graft technique, there was 39 males and 5 females, average age at the index surgery was 24,4 year (range 20-40), the average time from injury to operation was 4 months (range 1 week to 1 year), the average follow up period was 30 months (ranged 24-35), there was 19 patients with isolated ACL injury and 25 with associated intra articular pathology including 22 meniscal tear, 8 with articular cartilage injury (3 of them associated with the meniscal tears). Those injuries were treated with meniscal repair (12 cases), partial menisectomy (10 cases), debridement and shaving +/− micro fracture technique for the articular cartilage injuries. Results. at the final follow up all patients were satisfied with their knees, the IKDC improved from 68 +- 2.8(pre-op) to 92 +- 2.7 (CI-95%), and Lysholm score from 65 +- 3.2 to 93 +- 3(CI-95%) at the final visit. Anterior knee pain was reported in 4 patients (9%) on moderate to strenuous activities. 7 patients (16%) could not return to their pre-injury activity level. The mean difference in KT-1000 measurement was 2 +- 0.8. Conclusion. our technique is effective with compatible results with other ACL graft's technique with less complications rate when compared with PBTB auto graft, it avoids the remote incidence of patellar fractures, and reducing the incidence of anterior knee pain


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 155 - 155
1 Apr 2005
MacDonald A Venner R
Full Access

Aim: To compare the outcome of primary ACL reconstruction in patients who had either an autograft or allograft ACL procedure for symptomatic instability. Methods: 21 patients reviewed and assessed between 2 and 8 years post ACL reconstruction using patient centred scoring methods. Results: 21 patients underwent isolated primary ACL reconstruction. 14 patients underwent reconstruction with autologous patellar tendon “bone-tendon-bone” ipsilateral graft (mean time post op 3.55 years) and 7 had “bone-tendon-bone” allografts (mean time post op 2.13 years). Both operations were performed through an open approach. Previously validated Knee Outcome Survey of the Activities of Daily Living Scale questionnaires were completed for all patients and also a single score for overall satisfaction with the outcome. Overall levels of patient satisfaction and function were good. Testing the data with a one-sample t-test showed that donor graft patients showed higher levels of satisfaction, higher knee scores and less pain than autologous graft patients (p< 0.01). These data suggest that although autologous grafts are more commonly performed, there is an improved outcome in the group of patients following donor grafting of the ACL


Increasing expectations from arthroscopic anterior cruciate ligament (ACL) reconstructions require precise knowledge of technical details such as minimum intra-femoral tunnel graft lengths. A common belief of having ≥20mm of grafts within the femoral tunnel is backed mostly by hearsay rather than scientific proof. We examined clinico-radiological outcomes in patients with intra-femoral tunnel graft lengths <20 and ≥20mm. Primary outcomes were knee scores at 1-year. Secondarily, graft revascularization was compared using magnetic resonance imaging (MRI). We hypothesized that outcomes would be independent of intra-femoral tunnel graft lengths. This prospective, single-surgeon, cohort study was conducted at a tertiary care teaching centre between 2015–2018 after obtaining ethical clearances and consents. Eligible arthroscopic ACL reconstruction patients were sequentially divided into 2 groups based on the intra-femoral tunnel graft lengths (A: < 20 mm, n = 27; and B: ≥ 20 mm, n = 25). Exclusions were made for those > 45 years of age, with chondral and/or multi-ligamentous injuries and with systemic pathologies. All patients were postoperatively examined and scored (Lysholm and modified Cincinnati scores) at 3, 6 and 12 months. Graft vascularity was assessed by signal-to-noise quotient ratio (SNQR) using MRI. Statistical significance was set at p<0.05. Age and sex-matched patients of both groups were followed to 1 year (1 dropout in each). Mean femoral and tibial tunnel diameters (P =0.225 and 0.595) were comparable. Groups A (<20mm) and B (≥20mm) had 27 and 25 patients respectively. At 3 months, 2 group A patients and 1 group B patient had grade 1 Lachman (increased at 12 months to 4 and 3 patients respectively). Pivot shift was negative in all patients. Lysholm scores at 3 and 6 months were comparable (P3= 0.195 and P6= 0.133). At 1 year both groups showed comparable Cincinnati scores. Mean ROM was satisfactory (≥130 degrees) in all but 2 patients of each group (125–130 degrees). MRI scans at 3 months and 1 year observed anatomical tunnels in all without any complications. Femoral tunnel signals in both groups showed a fall from 3–12 months indicating onset of maturation of graft at femoral tunnel. Our hypothesis, clinical and radiological outcomes would be independent of intra-tunnel graft lengths on the femoral aspect, did therefore prove correct. Intra-femoral tunnel graft lengths of <20 mm did not compromise early clinical and functional outcomes of ACL reconstructions. There seems to be no minimum length of graft within the tunnel below which suboptimal results should be expected


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 213 - 213
1 Jan 2013
Ajuied A Norris M Wong F Clements J Back D Davies A
Full Access

Introduction. The advent of double bundle ACL (Anterior Cruciate Ligament) reconstruction had been hailed as potentially allowing for more anatomically and physiologically functioning graft, however until recently there had been little evidence of enhanced functional outcomes. The aim of this study is to explore whether the dimensions of hamstring two strand single bundle grafts, are predictive of the combined four strand single bundle graft that results from combining the single bundle grafts, as well as the impact of double bundle grafts upon the available healing and attachment area within the bony tunnels. Methods. Grafts of all likely two strand single bundle graft sizes, measured to the nearest 0.5mm in diameter using unslotted sizing block, were prepared using porcine flexor tendons,. These two strand single bundles were then systematically combined, and re-measured. By geometrical calculation, the sum of the circumferences of the two, two strand double bundle grafts were compared to the combined four strand single bundle graft formed by combining the two smaller bundles. Results. Measuring to the closest 0.5mm, we identified that the predicted four strand single bundle diameters were statistically larger (P < 0.001) than those that were measured. Geometric assessment reveals that dividing a four stand single bundle graft into it's two stand double bundle components, results in an increase in total graft circumference of 32% to 41%. Conclusions. We identified a statistically significant difference between measured and predicted four strand single bundle graft sizes. This result suggests that the viscoelastic properties of the tendon tissue increases as the cross sectional area of the graft increases. Our geometric assessment also demonstrates an increase in available graft to bone contact and healing area, of between 32% to 41%. Therefore one may theorise that double bundle ACL reconstruction results in earlier attainment of graft integration


Bone & Joint Research
Vol. 12, Issue 12 | Pages 722 - 733
6 Dec 2023
Fu T Chen W Wang Y Chang C Lin T Wong C

Aims. Several artificial bone grafts have been developed but fail to achieve anticipated osteogenesis due to their insufficient neovascularization capacity and periosteum support. This study aimed to develop a vascularized bone-periosteum construct (VBPC) to provide better angiogenesis and osteogenesis for bone regeneration. Methods. A total of 24 male New Zealand white rabbits were divided into four groups according to the experimental materials. Allogenic adipose-derived mesenchymal stem cells (AMSCs) were cultured and seeded evenly in the collagen/chitosan sheet to form cell sheet as periosteum. Simultaneously, allogenic AMSCs were seeded onto alginate beads and were cultured to differentiate to endothelial-like cells to form vascularized bone construct (VBC). The cell sheet was wrapped onto VBC to create a vascularized bone-periosteum construct (VBPC). Four different experimental materials – acellular construct, VBC, non-vascularized bone-periosteum construct, and VBPC – were then implanted in bilateral L4-L5 intertransverse space. At 12 weeks post-surgery, the bone-forming capacities were determined by CT, biomechanical testing, histology, and immunohistochemistry staining analyses. Results. At 12 weeks, the VBPC group significantly increased new bone formation volume compared with the other groups. Biomechanical testing demonstrated higher torque strength in the VBPC group. Notably, the haematoxylin and eosin, Masson’s trichrome, and immunohistochemistry-stained histological results revealed that VBPC promoted neovascularization and new bone formation in the spine fusion areas. Conclusion. The tissue-engineered VBPC showed great capability in promoting angiogenesis and osteogenesis in vivo. It may provide a novel approach to create a superior blood supply and nutritional environment to overcome the deficits of current artificial bone graft substitutes. Cite this article: Bone Joint Res 2023;12(12):722–733


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 63 - 63
7 Aug 2023
Kumar D Agarwal A Kushwaha N
Full Access

Abstract. Purpose. Since arthroscopic reconstruction of the anterior cruciate ligament (ACL) started, the use of peroneus longus grafts for primary ACL reconstruction (ACLR) was never thought of as there is very scant literature on it. So, our study aims to compare the functional outcome and complications in patients with ACL injury managed by ACLR with peroneus longus tendon (PLT) and hamstring tendons (HT) respectively. Materials and Methods. Patients with 16–50 years of either gender presenting with symptomatic ACL deficiency were admitted for arthroscopic single bundle ACLR and allocated into two groups (PLT and HT) operated and observed. Functional scores (IKDC and Lysholm score), clinical knee evaluation, donor site morbidity (AOFAS score) and thigh circumference were recorded preoperatively and at six months, one year post-operatively. The same post-op rehabilitation protocol was followed in both groups. Results. 194 patients (hamstring n=96, peroneus n=98) met the inclusion criteria. There were no significant differences between the pre-op, six months post-op and one-year postoperative score between the hamstring and peroneus longus groups in the IKDC (p=0.356) and Lysholm knee score (p=0.289). The mean for the AOFAS was 99.05±3.56 and 99.80±0.70 in the PLT and HT group respectively showing no statistical difference, with a significant improvement in thigh muscle wasting among the PLT group at final follow-up (p<0.001). Conclusion. We observed similar knee stability, functional outcome and no obvious donor site morbidity among both groups and recommend that a PL graft may be a safe, effective, and viable option for arthroscopic single bundle ACL reconstruction


Bone & Joint Research
Vol. 8, Issue 11 | Pages 518 - 525
1 Nov 2019
Whitaker S Edwards JH Guy S Ingham E Herbert A

Objectives. This study investigated the biomechanical performance of decellularized porcine superflexor tendon (pSFT) grafts of varying diameters when utilized in conjunction with contemporary ACL graft fixation systems. This aimed to produce a range of ‘off-the-shelf’ products with predictable mechanical performance, depending on the individual requirements of the patient. Methods. Decellularized pSFTs were prepared to create double-bundle grafts of 7 mm, 8 mm, and 9 mm diameter. Femoral and tibial fixation systems were simulated utilizing Arthrex suspension devices and interference screws in bovine bone, respectively. Dynamic stiffness and creep were measured, followed by ramp to failure from which linear stiffness and load at failure were measured. The mechanisms of failure were also recorded. Results. Dynamic stiffness was found to increase with greater graft diameter, with significant differences between all groups. Conversely, dynamic creep reduced with increasing graft diameter with significant differences between the 7 mm and 9 mm groups and the 8 mm and 9 mm groups. Significant differences were also found between the 7 mm, 8 mm, and 9 mm groups for linear stiffness, but no significant differences were found between groups for load at failure. The distribution of failure mechanisms was found to change with graft diameter. Conclusion. This study showed that decellularized pSFTs demonstrate comparable biomechanical properties to other ACL graft options and are a potentially viable option for ACL reconstruction. Although grafts can be stratified by their diameter to provide varying biomechanical properties, it may be more appropriate to alter the fixation technique to stratify for a greater diversity of biomechanical requirements. Cite this article: Bone Joint Res 2019;8:518–525


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 116 - 122
1 Jun 2020
Bedard NA Cates RA Lewallen DG Sierra RJ Hanssen AD Berry DJ Abdel MP

Aims. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11). Results. Survival free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at five years. Survival free from any revision of the construct and free from any reoperation were 92% and 73% at five years, respectively. A total of six patients (six TKAs, 17%) required a further revision, four for infection or wound issues, and two for periprosthetic fracture. Radiologically, one unrevised TKA had evidence of loosening which was asymptomatic. In all unrevised TKAs the impacted diaphyseal bone graft appeared to be incorporated radiologically. Conclusion. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this technique combining diaphyseal impaction grafting with a metaphyseal cone provided near universal success in relation to implant fixation. Moreover, radiographs revealed incorporation of the bone graft and biological fixation of the cone. While long-term follow-up will be important, this technique provides an excellent option for the management of complex revision TKAs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):116–122


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 99 - 99
23 Feb 2023
Woodfield T Shum J Linkhorn W Gadomski B Puttlitz C McGilvray K Seim H Nelson B Easley J Hooper G
Full Access

Polyetheretherketone (PEEK) interbody fusion cages combined with autologous bone graft is the current clinical gold standard treatment for spinal fusion, however, bone graft harvest increases surgical time, risk of infection and chronic pain. We describe novel low-stiffness 3D Printed titanium interbody cages without autologous bone graft and assessed their biological performance in a pre-clinical in vivo interbody fusion model in comparison to the gold standard, PEEK with graft. Titanium interbody spacers were 3D Printed with a microporous (Ti1: <1000μm) and macroporous (Ti2: >1000μm) design. Both Ti1 and Ti2 had an identical elastic modulus (stiffness), and were similar to the elastic modulus of PEEK. Interbody fusion was performed on L2-L3 and L4-L5 vertebral levels in 24 skeletally mature sheep using Ti1 or Ti2 spacers, or a PEEK spacer filled with iliac crest autograft, and assessed at 8 and 16 weeks. We quantitatively assessed bone fusion, bone area, mineral apposition rate and bone formation rate. Functional spinal units were biomechanically tested to analyse range of motion, neutral zone, and stiffness. Results: Bone formation in macroporous Ti2 was significantly greater than microporous Ti1 treatments (p=.006). Fusion scores for Ti2 and PEEK demonstrated greater rates of bone formation from 8 to 16 weeks, with bridging rates of 100% for Ti2 at 16 weeks compared to just 88% for PEEK and 50% for Ti1. Biomechanical outcomes significantly improved at 16 versus 8 weeks, with no significant differences between Ti and PEEK with graft. This study demonstrated that macroporous 3D Printed Ti spacers are able to achieve fixation and arthrodesis with complete bone fusion by 16 weeks without the need for bone graft. These significant data indicate that low-modulus 3D Printed titanium interbody cages have similar performance to autograft-filled PEEK, and could be reliably used in spinal fusion avoiding the complications of bone graft harvesting


Abstract. Objectives. To determine the effectiveness of LIA compared to ACB in providing pain relief and reducing opiates usage in hamstring graft ACL reconstructions. Materials and Methods. In a consecutive series of hamstring graft ACL reconstructions, patients received three different regional and/or anaesthetic techniques for pain relief. Three groups were studied: group 1: general anaesthetic (GA)+ ACB (n=38); group 2: GA + ACB + LIA (n=31) and group 3: GA+LIA (n=36). ACB was given under ultrasound guidance. LIA involved infiltration at skin incision site, capsule, periosteum and in the hamstring harvest tunnel. Analgesic medications were similar between the three groups as per standard multimodal analgesia (MMA). Patients were similar in demographics distribution and surgical technique. The postoperative pain and total morphine requirements were evaluated and recorded. The postoperative pain was assessed using the visual analogue scores (VAS) at 0hrs, 2hrs, 4hrs, weight bearing (WB) and discharge (DC). Results. There was no statistically significant difference in opiates intake amongst the three groups. When comparing VAS scores; there were no statistical difference between the groups at any of the time intervals that VAS was measured. However, the GA+LIA group hospital's LOS (m=2.31hrs, SD=0.75) was almost half that of GA+ACB group (m=4.24hrs, SD=1.08); (conditions t(72)=8.88; p=0.000). There was no statistical significance in the incidence of adverse effects amongst the groups. Conclusion. The LIA technique provided equally good pain relief following hamstring graft ACL reconstructions when compared to ACB, while allowing for earlier rehabilitation, mobilisation and discharge


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 714 - 723
1 Jun 2017
Grassi A Nitri M Moulton SG Marcheggiani Muccioli GM Bondi A Romagnoli M Zaffagnini S

Aims. Our aim was to perform a meta-analysis of the outcomes of revision anterior cruciate ligament (ACL) reconstruction, comparing the use of different types of graft. Materials and Methods. A search was performed of Medline and Pubmed using the terms “Anterior Cruciate Ligament” and “ACL” combined with “revision”, “re-operation” and “failure”. Only studies that reported the outcome at a minimum follow-up of two years were included. Two authors reviewed the papers, and outcomes were subdivided into autograft and allograft. Autograft was subdivided into hamstring (HS) and bone-patellar tendon-bone (BPTB). Subjective and objective outcome measures were analysed and odds ratios with confidence intervals were calculated. Results. A total of 32 studies met the inclusion criteria. Five studies used HS autografts, eight reported using BPTB autografts, two used quadriceps tendon autografts and eight used various types. Seven studies reported using allografts, while the two remaining used both BPTB autografts and allografts. Overall, 1192 patients with a mean age of 28.7 years (22.5 to 39) and a mean follow-up of 5.4 years (2.0 to 9.6) were treated with autografts, while 269 patients with a mean age of 28.4 years (25 to 34.6) and a mean follow-up of 4.0 years (2.3 to 6.0) were treated with allografts. Regarding allografts, irradiation with 2.5 mrad was used in two studies while the graft was not irradiated in the seven remaining studies. Reconstructions following the use of autografts had better outcomes than those using allograft with respect to laxity, measured by KT-1000/2000 (MEDmetric Corporation) and the rates of complications and re-operations. Those following the use of allografts had better mean Lysholm and Tegner activity scores compared with autografts. If irradiated allografts were excluded from the analysis, outcomes no longer differed between the use of autografts and allografts. Comparing the types of autograft, all outcomes were similar except for HS grafts which had better International Knee Documentation Committee scores compared with BPTB grafts. Conclusion. Autografts had better outcomes than allografts in revision ACL reconstruction, with lower post-operative laxity and rates of complications and re-operations. However, after excluding irradiated allografts, outcomes were similar between autografts and allografts. Overall, the choice of graft at revision ACL reconstruction should be on an individual basis considering, for instance, the preferred technique of the surgeon, whether a combined reconstruction is required, the type of graft that was previously used, whether the tunnels are enlarged and the availability of allograft. Cite this article: Bone Joint J 2017;99-B:714–23


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 72 - 72
1 Jul 2020
Kerslake S Tucker A Heard SM Buchko GM Hiemstra LA Lafave M
Full Access

The primary purpose of this study was to assess whether patients presenting with clinical graft laxity following primary anatomic anterior cruciate ligament (ACL) reconstruction using hamstring autograft reported a significant difference in disease-specific quality-of-life (QOL) as measured by the ACL-QOL questionnaire. Clinical ACL graft laxity was assessed in a cohort of 1134/1436 (79%) of eligible patients using the Lachman and Pivot-shift tests pre-operatively and at 12- and 24-months following ACL reconstruction. Post-operative ACL laxity was assessed by an orthopaedic surgeon and a physical therapist who were blinded to each other's examination. If there was a discrepancy between the clinical examination findings from these two assessors, then a third impartial examiner assessed the patient to ensure a grading consensus was reached. Patients completed the ACL-QOL questionnaire pre-operatively, and 12- and 24-months post-operatively. Descriptive statistics were used to assess patient demographics, rate of post-operative ACL graft laxity, surgical failures, and ACL-QOL scores. A Spearman rho correlation coefficient was utilised to assess the relationships between ACL-QOL scores and the Lachman and Pivot-shift tests at 24-months post-operative. An independent t-test was used to determine if there were differences in the ACL-QOL scores of subjects who sustained a graft failure compared to the intact graft group. ACL-QOL scores and post-operative laxity were assessed using a one-way analysis of variance (ANOVA). There were 70 graft failures (6.17%) in the 1134 patients assessed at 24-months. A total of 226 patients (19.9%) demonstrated 24-months post-operative ACL graft laxity. An isolated positive Lachman test was assessed in 146 patients (12.9%), an isolated positive Pivot-shift test was apparent in 14 patients (1.2%), and combined positive Lachman and Pivot-shift tests were assessed in 66 patients (5.8%) at 24-months post-operative. There was a statistically significant relationship between 24-month post-operative graft laxity and ACL-QOL scores (p < 0.001). Specifically, there was a significant correlation between the ACL-QOL and the Lachman test (rho = −0.20, p < 0.001) as well as the Pivot-shift test (rho = −0.22, p < 0.001). There was no significant difference between the scores collected from the graft failure group prior to failure occurring (mean = 74.38, SD = 18.61), and the intact graft group (mean = 73.97, SD = 21.51). At 24-months post-operative, the one-way ANOVA demonstrated a statistically significant difference between the ACL-QOL scores of the no laxity group (mean = 79.1, SD = 16.9) and the combined positive Lachman and Pivot-shift group (mean = 68.5, SD = 22.9), (p = 0, mean difference = 10.6). Two-years post ACL reconstruction, 19.9% of patients presented with clinical graft laxity. Post-operative graft laxity was significantly correlated with lower ACL-QOL scores. The difference in ACL-QOL scores for patients with an isolated positive Lachman or Pivot-shift test did not meet the threshold of a clinically meaningful difference. Patients with clinical laxity on both the Lachman and Pivot-shift tests demonstrated the lowest patient-reported ACL-QOL scores, and these results exceeded the minimal clinically important difference


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 999 - 1005
1 Jul 2010
Akiyama T Clark JCM Miki Y Choong PFM

Internal hemipelvectomy is a standard treatment for malignant tumours of the pelvis. Reconstruction using a non-vascularised fibular graft is relatively straightforward compared to other techniques. We describe the surgical and functional outcomes for a series of ten patients who underwent an internal hemipelvectomy (type I or I/IV) with reconstruction by a non-vascularised fibular graft between 1996 and 2009. A key prerequisite for this procedure was a preserved sciatic notch, confirmed pre-operatively on MRI. Graft-host union was achieved in all patients with a single fibular graft, and in the lower graft where two grafts had been used. The mean time to union was 7.3 months (3 to 12). The upper graft did not unite in four of six cases where two grafts had been used. Seven patients were eventually able to walk without a stick. The mean post-operative Musculoskeletal Tumour Society score was 75.4% (16.7 to 96.7). There were no cases of deep post-operative infection. The mean pelvic shortening was 0.9 cm (0.2 to 3.4). Recurrent tumour occurred in three cases, and death from tumour-related disease occured in one. Patients who need an internal hemipelvectomy will do well if their pelvic ring is reconstructed with a non-vascularised fibular graft. The complication rate is low, and they attain a good functional outcome


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 134 - 138
1 Jan 2017
Houdek MT Bayne CO Bishop AT Shin AY

Aims. Free vascularised fibular grafting has been used for the treatment of large bony defects for more than 40 years. However, there is little information about the risk factors for failure and whether newer locking techniques of fixation improve the rates of union. The purpose of this study was to compare the rates of union of free fibular grafts fixed with locking and traditional techniques, and to quantify the risk factors for nonunion and failure. Patients and Methods. A retrospective review involved 134 consecutive procedures over a period of 20 years. Of these, 25 were excluded leaving 109 patients in the study. There were 66 men and 43 women, with a mean age of 33 years (5 to 78). Most (62) were performed for oncological indications, and the most common site (52) was the lower limb. Rate of union was estimated using the Kaplan-Meier method and risk factors for nonunion were assessed using Cox regression. All patients were followed up for at least one year. Results. The rate of union was 82% at two years and 97% at five years. Union was achieved after the initial procedure in 76 patients (70%) at a mean of ten months (3 to 19), and overall union was achieved in 99 patients (91%). No surgical factor, including the use of locked fixation or supplementary corticocancellous bone grafts increased the rate of union. A history of smoking was significantly associated with a risk of nonunion. Discussion. Free vascularised fibular grafting is a successful form of treatment for large bony defects. These results suggest that the use of modern techniques of fixation does not affect the risk of nonunion when compared with traditional forms of fixation, and smoking increases the risk of nonunion following this procedure. Cite this article: Bone Joint J 2017;99-B:134–8