Advertisement for orthosearch.org.uk
Results 1 - 20 of 113
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 36 - 36
1 Dec 2021
Hussain A Rohra S Hariharan K
Full Access

Abstract. Background. Tibiotalocalcaneal (TTC) fusion is indicated for severe arthritis, failed ankle arthroplasty, avascular necrosis of talus and as a salvage after failed ankle fixation. Patients in our study had complex deformities with 25 ankles having valgus deformities (range 50–8 degrees mean 27 degrees). 12 had varus deformities (range 50–10 degrees mean 26 degrees) 5 ankles an accurate measurement was not possible on retrospective images. 10 out of 42 procedures were done after failed previous surgeries and 8 out of 42 had talus AVN. Methods. Retrospective case series of patients with hindfoot nails performed in our centre identified using NHS codes. Total of 41 patients with 42 nails identified with mean age of 64 years. Time to union noted from X-rays and any complications noted from the follow-up letters. Patients contacted via telephone to complete MOXFQ and VAS scores and asked if they would recommend the procedure to patients suffering similar conditions. 17 patients unable to fill scores (5 deceased, 4 nails removed, 2 cognitive impairment and 6 uncontactable). Results. In our cohort 33/38 of hindfoot nails achieved both subtalar and ankle fusion in a mean time of 7 months. 25 patients with 26 nails had mean follow up with post op scores of 4 years. Their Mean MOXFQ scores were (Pain: 12.8 Walking: 12 Social: 8) and visual analogue pain score was 3. 85% of patients wound recommend this surgery for a similar condition. 20 complications with 15 requiring surgery(5 screw removals, 1 percutaneous drilling, 1 fusion site injection, 8 nail revisions). Conclusion. In our experience hindfoot nail TTC fusion reliably improves the function of patients with severe symptoms in a variety of pathophysiological conditions and complex deformities. Most of our patients would recommend this procedure. There is a lack of studies with long-term follow-up


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 96 - 96
1 Dec 2020
Şahin E Berk H Özkal S Balcı P Balcı A
Full Access

The use of antifibrinolytic drugs and many other agents have a critical importance in bleeding control. Tranexamic acid [4- (aminomethyl) cyclohexanecarboxylic acid] is a synthetic amino acid lysine derivative with antifibrinolytic activity in humans. There are many studies in the literature that show that it is effective and effective both systemically and locally in spinal surgery. However, all of these studies have investigated the effects of topical tranexamic acid on bleeding and its effect on fusion has not been investigated yet. Aim of this study is to investigate the effect of topical tranexamic acid on fusion using macroscopic, radiologic and microscopic techniques. After approve of ethics committee with the protocol number 19/2019 for 28 Wistar Albino rats underwent intertransvers fusion. All rats were randomized into four (4) groups, using sealed envelopes. Local tranexamic acid (Transamin® 100 mg/ml, Teva İlaç, İstanbul) doses was determined based on previously conducted studies; 1mg/kg (D1 group), 10mg/kg (D10 group), 100 mg/kg (D100 group) and no tranexamic acid (D0 group). At the end of 8. th. weeks all rats were evaluated with manuel palpation, mammography and histopathologic analysis. Radiographic examination was performed two times to evaluate the intra and inter observer differences. 2 rats in-group D0 died after the radiographic examination. Assessment of fusion with manual palpation revealed that use of local 1mg / kg tranexamic acid had no effect on fusion (p=0.32), however with increasing doses of tranexamic acid had negative effect on fusion (p=0.002). On radiologic examination, spearman's rho correlation coefficient was found to be moderate in the first evaluation (r=0.46) and high in second evaluation (r=0.61). Radiological examination revealed that the control group was the best in fusion (p=0.007), and that tranexamic acid affected fusion adversely, independent of dosage (p=0.27). Among the groups in histopathologic examination, no statistical difference was found (p=0.134). Local administration of tranexamic acid affects the intertransverse fusion adversely depending on the dosage macroscopically and it also affects fusion adversely independent of the dosage radiologically and histopathologically


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 39 - 39
1 Dec 2020
Çetin E Daldal İ Eren A Dizakar SÖA Ömeroğlu S Uzuner B Çelik H Saygılı HH Koçkar B Şenköylü A
Full Access

Due to well-known disadvantages of the autologous bone graft, many alternatives have been studied for a reliable spinal fusion. Herein, we aimed to investigate the effects of human recombinant epidermal growth factor (EGF) on posterolateral lumbar fusion in a rat model. 36 male SD rats underwent posterolateral fusion at L4-5 level. They were randomly assigned to 3 groups: Sham control group, Hydoxyapatite β-tricalcium phosphate (HA/β-TCP) group and HA/β-TCP + EGF group. Rats were euthanized at 8 weeks post-surgery. 6 rats from each group were selected for manual palpation examination, micro-computed tomography analysis and histologic analysis; and the rest was used for biomechanical analysis. Based on manual palpation, there was no fusion in the sham control group. Fusion rate was 33.3% in the HA/β-TCP group and 66.7% in the HA/β-TCP + EGF group (p=0.085). Micro-CT results revealed that new bone formation was higher in the HA/β-TCP + EGF group (BV/TV: 40% vs. 65%) (p=0.004). Histologically newly formed bone tissue was more pronounced in the EGF group and compacted and bridging bone spicules were observed. The median maximum bending moment values were 0.51 Nmm (0.42– 0.59), 0.73 Nmm (0.49– 0.88) and 0.91 Nmm (0.66– 1.03) in the sham control, HA/β-TCP and HA/β-TCP + EGF groups, respectively (p=0.013). The median stiffness values were 1.69 N/mm (1.12–2.18), 1.68 N/mm (1.13–2.74) and 3.10 N/mm (1.66–4.40) as in the previous order (p=0.087). This study demonstrates that EGF enhances posterolateral lumbar fusion in the rat model. EGF in combination with ceramic grafts increased the fusion rates


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 59 - 59
2 Jan 2024
Depboylu F
Full Access

Production of porous titanium bone implants is a highly promising research and application area due to providing high osseointegration and achieving the desired mechanical properties. Production of controlled porosity in titanium implants is possible with laser powder bed fusion (L- PBF) technology. The main topics of this presentation includes the L-PBF process parameter optimization to manufacture thin walls of porous titanium structures with almost full density and good mechanical properties as well as good dimensional accuracy. Moreover, the cleaning and coating process of these structures to further increase osseointegration and then in-vitro biocompatibility will be covered


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 107 - 107
1 Dec 2020
Omidi-Kashani F Binava R Arki ZM Keshtan FG Madarshahian D
Full Access

Objective. Lumbar spinal stenosis (LSS) is a common spinal disorder mostly caused by the arthritic process. In cases with refractory complaints or significant neurologic deficit, decompressive surgery with or without instrumented fusion may be indicated. We aimed to investigate the surgical outcome of multi-level LSS in the patient with stable spine treated by simple decompression versus decompression and instrumented fusion. Methods: We retrospectively studied 51 patients (25 male, 26 female) with stable multi-level (>2 levels) LSS who were treated by decompressive surgery alone (group A, 31 cases) and decompression and instrumented fusion (group B, 20 cases) and followed them for more than two years. The patients’ disability and pain were assessed with Oswestry Disability Index (ODI) and Visual Analogue Scale (VAS), respectively. At the last follow-up visit, patient satisfaction with surgery was also scored. Results: The two groups were homogeneous in terms of age, sex, severity of disability and pain. Surgery could significantly improve pain and disability in both groups. Preoperative ODI in group A and B were 51.0±23.7 and 54.5±22.9, respectively, however at the last follow-up visit these parameters improved to 23.1±21.1 and 36.6±21.4 showing a statistical significance. Mean patient satisfaction with surgical intervention was also higher in the simple decompression group, but this difference was not significant. Conclusion: In surgical treatment of the patients with multi-level but stable LSS, simple decompression versus decompression and instrumented fusion could achieve more disability improvement for more than two years of follow-up


Introduction and Objective. Posterior and transforaminal lumbar interbody fusion (PLIF, TLIF) represent the most popular techniques in performing an interbody fusion amongst spine surgeons. Pseudarthrosis, cage migration, subsidence or infection can occur, with subsequent failed surgery, persistent pain and patient’ bad quality of life. The goal of revision fusion surgery is to correct any previous technical errors avoiding surgical complications. The most safe and effective way is to choose a naive approach to the disc. Therefore, the anterior approach represents a suitable technique as a salvage operation. The aim of this study is to underline the technical advantages of the anterior retroperitoneal approach as a salvage procedure in failed PLIF/TLIF analyzing a series of 32 consecutive patients. Materials and Methods. We performed a retrospective analysis of patients’ data in patients who underwent ALIF as a salvage procedure after failed PLIF/TLIF between April 2014 to December 2019. We recorded all peri-operative data. In all patients the index level was exposed with a minimally invasive anterior retroperitoneal approach. Results. Thirty-two patients (average age: 46.4 years, median age 46.5, ranging from 21 to 74 years hold- 16 male and 16 female) underwent salvage ALIF procedure after failed PLIF/TLIF were included in the study. A minimally invasive anterior retroperitoneal approach to the lumbar spine was performed in all patients. In 6 cases (18.7%) (2 infection and 4 pseudarthrosis after stand-alone IF) only anterior revision surgery was performed. A posterior approach was necessary in 26 cases (81.3%). In most of cases (26/32, 81%) the posterior instrumentation was overpowered by the anterior cage without a previous revision. Three (9%) intraoperative minor complications after anterior approach were recorded: 1 dural tear, 1 ALIF cage subsidence and 1 small peritoneal tear. None vascular injuries occurred. Most of patients (90.6%) experienced an improvement of their clinical condition and at the last follow-up no mechanical complication occurred. Conclusions. According to our results, we can suggest that a favourable clinical outcome can firstly depend from technical reasons an then from radiological results. The removal of the mobilized cage, the accurate endplate and disc space preparation and the cage implant eliminate the primary source of pain reducing significantly the axial pain, helping to realise an optimal bony surface for fusion and enhancing primary stability. The powerful disc distraction given by the anterior approach allows inserting large and lordotic cages improving the optimal segmental lordosis restoration


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 32 - 32
2 Jan 2024
Depboylu F Yasa E Poyraz Ö Korkusuz F
Full Access

Decreasing the bulk weight without losing the biomechanical properties of commercial pure titanium (Cp-Ti) medical implants is now possible by using Laser Powder Bed Fusion (L-PBF) technology. Gyroid lattice structures that have precious mechanical and biological advantages because of similarity to trabecular bone. The aim of the study was to design and develop L-PBF process parameter optimization for manufacturing gyroid lattice Cp-Ti structures. The cleaning process was then optimized to remove the non-melted powder from the gyroid surface without mechanical loss. Gyroid cubic designs were created with various relative densities by nTopology. L-PBF process parameter optimization was progressed using with Cp-Ti (EOS TiCP Grade2) powder in the EOS M290 machine to achieve parts that have almost full dense and dimensional accuracy. The metallography method was made for density. Dimensional accuracy at gyroid wall thicknesses was investigated between designed and manufactured via stereomicroscope, also mechanical tests were applied with real time experiment and numerical analysis (ANSYS). Mass loss and strut thickness loss were investigated for chemical etching cleaning process. Gyroid parts had 99,5% density. High dimensional accuracy was achieved during L-PBF process parameters optimization. Final L-PBF parameters gave the highest 19% elongation and 427 MPa yield strength values at tensile test. Mechanical properties of gyroid were controlled with changing relative density. A minute chemical etching provided to remove non-melted powders. Compression test results of gyroids at numerical and real-time analysis gave unrelated while deformation behaviors were compatible with each other. Gyroid Cp-Ti osteosynthesis mini plates will be produced with final L-PBF process parameters. MTT cytotoxicity test will be characterized for cell viability. Acknowledgements This project is granted by TUBITAK (120N943). Feza Korkusuz MD is a member of the Turkish Academy of Sciences (TÜBA)


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 90 - 90
1 Mar 2021
Krticka M Nekuda V Trunec M Brinek A Sedlacek R Lukasova V Göpfrt E Stastny P Kafkova M Ira D Rampichova M Planka L Vojtova L
Full Access

The use of lumbar fusion procedures in the USA and Europe has rapidly increased over the last decade and a large number of these procedures involve the use of bone grafts. Despite of technical progress of spinal surgery and operative materials the risk of vertebral fusion failure occurs in 5 – 35 % of cases. Autografting has been considered the gold standard for bone graft procedures. However, the harvesting from the iliac crest can be associated with short and long-term morbidity in up to 22 % of cases. Main goal of this experimental study was to compare newly developed hybrid biodegradable nanocomposit porous implant (HBNPI) against bone craft from iliac crest as a new and better alternative for lumbar interbody fusion. 24 male pigs 4 months old weighting around 40 Kg were included in our study. These pigs were divided into two study groups depending on fusion method. Group A – 12 pigs underwent lateral lumbal interbody fusion (L2/3) with implantation of iliac crest bonegraft. Group B - 12 pigs underwent lateral lumbal interbody fusion (L2/3) with newly developed HBNPI. Each group were divided into two subgroups from these 6 spines were harvested 8 weeks (subgroup A1, B1) and 6 spines 16 weeks (group A2, B2) after surgery. After sacrifice, the lumbar spines were taking out and micro-CT, biomechanical testing and histomorphological analysis in all groups were performed to evaluate a quality of intervertebral fusion. As controls (group N), 6 cadaveric intact lumbar spines underwent biomechanical, micro-CT and histological testing. All 24 animals recovered from general anesthesia without unusual events. The operations lasted between 50–90 minutes (mean 70) in Group A and between 35–72 minutes (mean 43) in Group B. All of the pigs from group A could stand up and were mobile within 20 hours (range 7–20). When bone graft harvesting was not necessary (group B) this time was shortened, ranging from 1 – 1,5 hour. All pigs from Group A were limping on the first postoperative day. No limping animal was observed in group B. Total body weight of the pigs increased from 37 kg (range 36–40) at the start to 85 (range 80–89) at sacrifice. Biomechanics evaluation shows that extension flexural stiffness values are statistically significantly different between A2 (16 weeks post-implant) and A1 (8 weeks post-implant). Group A2 achieves higher values than Group A1, which is attributed to the adhesion of the implant to the surrounding vertebrae. Similarly, this also applies to groups B2 and B1. The flexural stiffness at group B2 extension is statistically significantly higher than the A2 group and also than the native N group. Biomechanical evaluation supports findings on micro-CT and histological specimens, where both adjacent vertebrae are completely fused in groups B2, unlike in group A2, where there is no or incomplete fusion. Newly developed HBNPI represents new possibility how to do intervertebral fusion, and simultaneous become chance how to improve and accelerate bone healing process against standard procedures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 43 - 43
11 Apr 2023
Amirouche F Mok J Leonardo Diaz R Forsthoefel C Hussain A
Full Access

Lateral lumbar interbody fusion (LLIF) has biomechanical advantages due to the preservation of ligamentous structures (ALL/PLL), and optimal cage height afforded by the strength of the apophyseal ring. We compare the biomechanical motion stability of multiple levels LLIF (4 segments) utilising PEEK interbody 26mm cages to stand-alone cage placement and with supplemental posterior fixation with pedicle screw and rods. Six lumbar human cadaver specimens were stripped of the paraspinal musculature while preserving the discs, facet joints, and osteoligamentous structures and potted. Specimens were tested under 5 conditions: intact, posterior bilateral fixation (L1-L5) only, LLIF-only, LLIF with unilateral fixation and LLIF with bilateral fixation. Non-destructive testing was performed on a universal testing machine (MTS Systems Corp) to produce flexion-extension, lateral-bending, and axial rotation using customized jigs and a pulley system to define a non-constraining load follower. Three-dimensional spine motion was recorded using a motion device (Optotrak). Results are reported for the L3-L4 motion segment within the construct to allow comparison with previously published works of shorter constructs (1-2 segments). In all conditions, there was an observed decrease in ROM from intact in flexion/extension (31%-89% decrease), lateral bending (19%-78%), and axial rotation (37%-60%). At flexion/extension, the decreases were statistically significant (p<0.007) except for stand-alone LLIF. LLIF+unilateral had similar decreases in all planes as the LLIF+bilateral condition. The observed ROM within the 4-level construct was similar to previously reported results in 1-2 levels for stand-alone LLIF and LLIF+bilateral. Surgeons may be concerned about the biomechanical stability of an approach utilizing stand-alone multilevel LLIF. Our results show that 4-level multilevel LLIF utilizing 26 mm cages demonstrated ROM comparable to short-segment LLIF. Stand-alone LLIF showed a decrease in ROM from the intact condition. The addition of posterior supplemental fixation resulted in an additional decrease in ROM. The results suggest that unilateral posterior fixation may be sufficient


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 24 - 24
1 Apr 2018
Magill H Shaath M Hajibandeh S Hajibandeh S Chandrappa MH
Full Access

Objectives. Our objective was to perform a systematic review of the literature and conduct a meta-analysis to investigate the outcomes of open versus arthroscopic methods of ankle fusion. Methods. In accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement standards, we performed a systematic review. Electronic databases MEDLINE, EMBASE, CINAHL and the Cochrane Central Register of Controlled Trials (CENTRAL) were searched to identify randomised and non-randomised studies comparing outcomes of arthroscopic and open ankle arthrodesis. The Newcastle-Ottawa scale was used to assess the methodological quality and risk of bias of the selected studies. Fixed-effect or random-effects models were applied to calculate pooled outcome data. Results. We identified one prospective cohort study and 5 retrospective cohort studies, enrolling a total of 286 patients with ankle arthritis. Our analysis showed that open ankle fusion was associated with a lower fusion rate (OR 0.26, 95% CI 0.13–0.52, P = 0.0002), longer tourniquet time (MD 16.49, 95% CI 9.46–23.41, P<0.00001), and longer length of stay (MD 1.60,95% CI 1.10–2.10, P<0.00001) compared to arthroscopic ankle fusion; however, there was no significant difference between two groups in terms of infection rate (OR 2.41, 95% CI 0.76–7.64, P = 0.14), overall complication rate (OR: 1.54, 95% CI 0.80–2.96, P = 0.20), and operation time (MD 4.09, 95% CI −2.49–10.66, P = 0.22). The between-study heterogeneity was high for tourniquet time but low or moderate for other outcomes. The direction of the effect sizes remains unchanged throughout sensitivity analyses. Conclusions. The best available evidence demonstrates that arthroscopic ankle fusion may be associated with a higher fusion rate, shorter tourniquet time, and shorter length of stay compared to open ankle fusion. We found no significant difference between two groups in terms of infection rate, overall complication rate, and operation time. The best available evidence is not adequately robust to make definitive conclusions. Long-term results of the comparative efficacy of arthroscopic ankle fusion over open ankle fusion are not currently available. Further high quality randomised controlled trials that are adequately powered are required


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 31 - 31
1 May 2017
Ahmed K Pillai A Somasundaram K
Full Access

Background. PROMS and PREMS are a fundamental and essential part of the NHS. Chilectomy and fusion procedures for hallux rigidus produce varied outcomes due to their subjective nature. PROMS2.0, a semi-automated web-based system, which allows collection and analysis of outcome data, to compare what PROMS/PREMS for chilectomy/fusion for hallux rigidus are at UHSM including variance across osteoarthritis grades. Methods. Data was collected from March-2013 to December-2014. Scores used to assess outcomes included EQ-5D-VAS, EQ-5D Health-Index, and MOxFQ, collected pre-operatively and post-operatively. Patient-Personal-Experience (PPE-15) was collected postoperatively. Data was compared. Results. 10 patients (4F, 6M) (9R, 1L) had a 1st MTPJ chilectomy. Average age- 47.3 (range 34–70). 16 patients (12F, 4M) (9RT, 7LT) had a 1st-MTPJ fusion. Average age-60.3yrs (range19–83). Chilectomy pre-op average MOXFQ scores for pain, walking and social interaction: 33.5 (range 5–70), 27.6 (range 0–64) and 24.9 (range 0–75) respectively. Post operatively these improved to 25.0 (range 0–70), 24.3 (range 0–68) and 21.9 (range 0–50). EQ5D scores showed a regression; pre-op index average of 0.72 and post op 0.70. Pre-op VAS score average of 86.8 with post-op 80.4. Fusion pre-op average MOXFQ scores for pain, walking and social interaction: 50.7 (range 25–75), 49.1 (range 4–75) and 48.4 (range 25–75) respectively. Post-operatively improved to 9.7 (range 0–57), 16.1 (range 0–57) and 20.1 (range 0–50). EQ5D scores showed improvement; with pre-op index average of 0.68 and post-op 0.83. Pre-op VAS score average of 72.5 and post-op 83.6. Higher grades of OA responded better to fusion and lower grades better to chilectomy. 17 patients (10 fusion/7 chilectomy) filled PPE-questionnaires. Results show overall satisfactory experience for both sets of patients. Conclusion. Both procedures show improved outcomes. Fusions have greater improvements than chilectomy based on reported outcomes. Higher grades of OA do better with fusion. Level of Evidence. Prospective case series- Level 3


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 70 - 70
1 Jan 2017
Peters M Brans B Wierts R Jutten L Weijers T Broos W Mottaghy F van Rhijn L Willems P
Full Access

The clinical success of posterior lumbar interbody fusion (PLIF) may be limited by pseudarthrosis, defined as the absence of solid fusion 1 year after surgery. Currently, CT is used to diagnose pseudarthrosis but is not able to be conclusive earlier than 1 year after surgery. No non-invasive technique is available to reliably assess bone graft incorporation in the early phase after PLIF. Positron Emission Tomography (PET) is a nuclear imaging modality that is able to identify changes at the cellular and molecular level in an early stage, well before manifestation of anatomical changes. PET/CT with the bone seeking tracer . 18. F-fluoride allows localization and quantification of bone metabolism. This study investigates whether an . 18. F-fluoride PET/CT scan early after PLIF is able to predict the fusion status at 1 year postoperative on CT. Twenty patients after PLIF were enrolled after written informed consent. At 6 weeks and at 1 year after PLIF, intravenous injection of . 18. F-fluoride was followed by a static scan at 60 minutes (Philips, Gemini TF PET/CT). Processing of images resulted in a bone metabolism parameter i.e. standardized uptake value (SUV). This parameter was determined for 3 regions of interest (ROIs): the intervertebral disc space (IDS) and the upper and lower endplate (UE and LE, respectively) of the operated segment. Interbody fusion was scored on a diagnostic CT scan made 1 year postoperatively and was defined as the amount of complete bony bridges between vertebrae, i.e 0, 1 or 2. Based on these scores, patients were divided in either the pseudarthrosis group (score 0) or the fusion group (scores 1 and 2). Differences between groups were analyzed using the independent samples Mann-Whitney U-test. Ten patients were classified as pseudarthrosis (0 bridges: n=10) and 10 patients as fused (1 bridge: n=5, 2 bridges: n=5). Patients in the pseudarthrosis group showed significantly lower bone metabolism values in the IDS on the 6 weeks PET/CT scan compared to patients in the fusion group (SUV. IDS,6w. 13.3±5.62 for pseudarthrosis and 22.6±6.42 for the fusion group, p=0.003), whereas values at the endplates were similar (SUV. UE,6w. 20.3±5.85 for pseudarthrosis and 21.6±4.24 for the fusion group, p=0.282). Furthermore, only in the pseudarthrosis group, bone metabolism in the IDS was significantly lower than at the endplates (p=0.006). In the fusion group, bone metabolism in the IDS and at the endplates was similar (p=0.470). The PET/CT scan at 1 year postoperative showed that in the pseudarthrosis group, bone metabolism of the IDS remained lower compared to the endplates (SUV. IDS,1y. 13.2±4.37, SUV. UE,1y. 16.4±5.33, p=0.004), while in the fusion group, IDS and endplate bone metabolism was similar (SUV. IDS,1y. 13.6±2.91, SUV. UE,1y. 14.4±3.14, p=0.397). This study shows that low bone metabolism values in the IDS of the operated segment as seen on . 18. F-fluoride PET/CT 6 weeks after PLIF, is related to development of pseudarthrosis 1 year postoperatively. These results suggest that . 18. F-fluoride PET/CT might be an early diagnostic tool to identify patients prone to develop pseudarthrosis after PLIF


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 39 - 39
1 Apr 2018
Daldal I Şenköylü A Değim T Tamer Sİ Ömeroğlu S Akarca O Çelik HH Ocak M Uzuner MB Saygılı HH Tuğrul HO Koçkar B Eren A
Full Access

Background context. Fusion is a fundamental procedure in spine surgery. Although autogenous grafts have ideal bone graft characteristics, their use may remain limited due to various morbidities. Even though ceramic based synthetic bone grafts are used commonly at present, in order to enhance their efficacy, their combined use with other materials has been investigated. The use of carbon nanotubes (CNTs) together with synthetic bone grafts such as hydroxyapatite (HA) has contributed to positive developments in bone tissue engineering. Purpose. The aim of the present study was to investigate the effect of CNTs/ HA- tricalcium phosphate (TCP) composite prepared in posterolateral spinal fusion model. Study Design/Setting. Experimental animal study. Methods. At first, CNTs and CNTs/HA-TCP composites were prepared. Twenty adult male Spraque Dawley rats were randomized into four groups with five rats in each group. Decortication was carried out in standard manner in all animals. Group 1 (only decortication), group 2 (CNTs), group 3 (HA-TCP) and group 4 (CNTs/HA-TCP) were formed. Eight weeks later all animals were sacrificed and obtained fusion segments were evaluated by manual palpation, histomorphometry and micro computed tomography (mCT). Results. In all evaluations, highest fusion values were obtained in Group 4. In mCT investigations, bone volume/ tissue volume (BV/TV) ratio was found to be significantly higher in composite group (group 4) only compared to ceramic group (group 3). Although in Group 2, in which only CNTs were used, the ratio was found to be significantly higher than group 1, the difference was not considered significant in terms of fusion and in addition in group 2, CNTs were completely surrounded by fibrous tissue, i.e. no bone formation was observed. Conclusions. The combined use of carbon nanotubes with ceramic based bone grafts enhances spinal fusion markedly. Although CNTs are inadequate in producing spinal fusion when they are used by themselves, due to especially their high biocompatibillity and unique bicomechanic characteristics compatible with bone tissue, they increase fusion rates significantly, particularly together with ceramic based synthetic grafts. Keywords. Spinal fusion; Rat; Carbon nanotube(s); Ceramic(s); Bone graft subsitutes; Hydroxyapatite


The current study aims to find the role of Enhance Recovery Pathway (ERP) as a multidisciplinary approach aimed to expedite rapid recovery, reduce LOS, and minimize morbidity associated with Non Fusion Anterior Scoliosis Correction (NFASC) surgery. A retrospective analysis of 35 AIS patients who underwent NFASC with Lenke 1 and Lenke 5 curves with a minimum of 1 year of follow-up was done. Patient demographics, surgical details, postoperative analgesia, mobilization, length of stay (LOS), patient satisfaction survey score with respect to information and care, and 90 days complications were collected. The cohort included 34 females and 1 male with a mean age of 15.2 years at the time of surgery. There were 16 Lenke 1 and 19 Lenke 5 in the study. Mean preoperative major thoracic and thoracolumbar/lumbar Cobb's angle were 52˚±7.6˚ and 51˚±4.5˚ respectively. Average blood loss and surgical time were 102 ±6.4 ml and 168 ± 10.2 mins respectively. Average time to commencing solid food was 6.5±1.5 hrs. Average time to mobilization following surgery was 15.5± 4.3 hrs. The average duration to the stopping of the epidural was 42.5±3.5 hrs. The average dose of opioid consumption intraoperatively was 600.5±100.5 mcg of fentanyl i.v. and 12.5±4.5 mg morphine i.v. Postoperatively opioids were administered via an epidural catheter at a dose of 2 mg of morphine every 24 hours up to 2 days and an infusion of 2mcg/hr of fentanyl along with 0.12-0.15% ropivacaine. The average duration to transition to oral analgesia was 55.5±8.5 hrs .20 patients had urinary catheter and the average time to removal of the catheter was 17.5±1.4 hrs. 25 patients had a chest tube and the average time to remove of chest tube was 25.5±3.2 hrs. The average length of hospital stay was 3.1±0.5 days. No patient had postoperative ileus or requirement of blood transfusion or any other complications. No correlation was found between LOS and initial cobb angle. The application of ERP in AIS patients undergoing NFASC results in reduced LOS and indirectly the cost, reduced post-operative opioid use, and overall improve patient satisfaction score


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 101 - 101
1 May 2012
Singh HP Dias PJJ
Full Access

Introduction. Isolated midcarpal motion during radioulnar deviation could be approximated to be a rotation in a plane of a radiodorsal/ulnopalmar rotation of the wrist, which may coincide with a motion plane of one of the most essential human wrist motions, known as the dart-throwing motion. This has been studied before in normal volunteers using Magnetic Resonance Imaging to study in vivo kinematics of the midcarpal joint in the wrists of normal volunteers. We present the early results of use of biaxial flexible electrogoniometer to study the range of motion in patients with four-corner fusion. Methods. Ten patients with four-corner fusion for SLAC/SNAC wrist were assessed to study flexion-extension, radial-ulnar deviation, and circumduction motions using flexible electrogoniometers. Opposite unaffected wrist was studied to provide normal data. Angle-angle curves (Lissajous's figures) were generated to study the area under the curve and comparison with the normal wrists and also to study the deviation from the neutral axis. Five normal volunteers were also studied to calculate the area under the curve and the axis of deviation during circumduction of the wrist. Results. The coupling action of mid-carpal motion was revealed as obliquity of the axis of motion with extension combined with radial deviation in normal wrists. This was lost in patients with four-corner fusion as revealed with decrease of obliquity in Lissajous's figures from 19 degrees to 5 degrees. There was 80% reduction in the area in the curve of the figures in comparison to normal wrists (4000 to 960 degree-degrees). Discussion. Electrogoniometer and Lissajous's figures provide a useful method of assessment of range of motion in patients with four-corner fusion. They could be used in future for comparison with patients undergoing limited wrist fusion to study the disability experienced and for counselling regarding the postoperative limitation in activities of daily living experienced by these patients


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 19 - 19
1 Jul 2014
Hart R Komzák M Puskeiler M Jajtner P
Full Access

Background. Posterolateral fusion (PLF) is a commonly accepted surgical procedure and overall the most common technique performed to obtain fusion in the lumbar spine. Harvesting autologous bone from the iliac crest is associated with increased operation time, blood loss, and chronic donor site pain. Allograft material has an insufficient osteoinductive potential. Bone marrow concentrate (BMC) could be an option how to promote allograft PLF healing. The purpose of the presented study was to investigate the validity of BMC addition to allografts in instrumented lumbar PLF surgery. Methods. The study was prospective, randomised, controlled and blinded. Eighty patients with degenerative disease of the lumbar spine underwent instrumented (S. 4. , Aesculap, Tuttlingen, Germany) lumbar or lumbosacral PLF. In forty cases, the PLF was done with spongious allograft chips alone (Group I). In another forty cases, spongious allograft chips were mixed with BMC (Group II), where the mesenchymal stem cell (MSCs) concentration was 1.74 × 10. 4. /L at average (range, 1.06–1.98 × 10. 4. /L). Patients were scheduled for anteroposterior and lateral radiographs at 12 and 24 months after the surgery and for CT scanning at 24 months after the surgery. Fusion status and the degree of mineralization of the fusion mass were evaluated separately by two radiologists blinded to patient group affiliation. Results. In Group I at 12 months, the bone graft mass was assessed in X-rays as fused in no case (0 %) and at 24 months in 4 cases (10 %). In Group II, 6 cases (15 %) achieved fusion at 12 months and 14 cases (35 %) at 24 months. The statistically significant difference between both groups was proven for complete fusion at 12 months (p = 0.041) and at 24 months (p = 0.011), too. CT scans showed that 16 cases (40 %) in Group I and 32 cases (80 %) in Group II had evidence of at least unilateral continuous bridging bone between neighboring vertebrae at 24 months (p < 0.05). We have confirmed the hypothesis that the autologous BMC together with the allograft is a better alternative for the PLF than the allograft alone. Conclusions. The use of autologous MSCs in form of the BMC in combination with allograft is an effective option how to enhance the PLF healing. Allograft by itself is not an effective material as a posterior onlay graft for the PLF in adult surgery


The current study aims to compare the clinico radiological outcomes between Non-Fusion Anterior Scoliosis (NFASC) Correction and Posterior Spinal Fusion (PSF) for Lenke 5 curves at 2 years follow up. Methods:38 consecutive Lenke 5 AIS patients treated by a single surgeon with NFASC (group A) or PSF (group B) were matched by age, Cobb's angle, and skeletal maturity. Intraoperative blood loss, operative time, LOS, coronal Cobbs, and SRS22 scores at 2 years were compared. Flexibility was assessed by modified Schober's test. Continuous variables were compared using student t-tests and categorical variables were compared using chi-square. The cohort included 19 patients each in group A and B . Group A had M:F distribution of 1:18 while group B had 2:17. The mean age in group A and group B were 14.8±2.9 and 15.3±3.1 years respectively. The mean follow-up of patients in groups A and B were 24.5±1.8 months and 27.4±2.1 months respectively. Mean pre-op thoracolumbar/lumbar (TL/L) cobbs for group A and group B were 55°±7° and 57.5°±8° respectively. At two years follow up, the cobbs for group A and B were 18.2°±3.6° and 17.6°±3.5° respectively (p=0.09). The average operating time for groups A and B were 169±14.2 mins and 219±20.5 mins respectively (p<0.05). The average blood loss of groups A and B were 105.3±15.4 and 325.3±120.4 respectively (p<0.05). The average number of instrumented vertebra between groups A and B were 6.2 and 8.5 respectively (p<0.05). The average LOS for NFASC and PSF was 3.3±0.9 days and 4.3±1.1 days respectively (p<0.05). No statistically significant difference in SRS 22 score was noted between the two groups. No complications were recorded. Our study shows no significant difference in PSF and NFASC in terms of Cobbs correction and SRS scores, but the NFASC group had significantly reduced blood loss, operative time, and fewer instrumented levels. NFASC is an effective alternative technique to fusion to correct and stabilize Lenke 5 AIS curves with preservation of spinal motion


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 98 - 98
4 Apr 2023
Lu V Tennyson M Zhang J Zhou A Thahir A Krkovic M
Full Access

Fragility ankles fractures in the geriatric population are challenging to manage, due to fracture instability, soft tissue compromise, patient co-morbidities. Traditional management options include open reduction internal fixation, or conservative treatment, both of which are fraught with high complication rates. We aimed to present functional outcomes of elderly patients with fragility ankle fractures treated with tibiotalocalcaneal nails.

171 patients received a tibiotalocalcaneal nail over a six-year period, but only twenty met the inclusion criteria of being over sixty and having poor bone stock, verified by radiological evidence of osteopenia or history of fragility fractures. Primary outcome was mortality risk from co-morbidities, according to the Charlson co-morbidity index (CCI), and patients’ post-operative mobility status compared to pre-operative mobility. Secondary outcomes include intra-operative and post-operative complications, six-month mortality rate, time to mobilisation and union.

The mean age was 77.82 years old, five of whom are type 2 diabetics. The average CCI was 5.05. Thirteen patients returned to their pre-operative mobility state. Patients with low CCI are more likely to return to pre-operative mobility status (p=0.16; OR=4.00).

Average time to bone union and mobilisation were 92.5 days and 7.63 days, respectively. Mean post-operative AOFAS ankle-hindfoot and Olerud-Molander scores were 53.0 (range 17-88) and 50.9 (range 20-85), respectively. There were four cases of broken distal locking screws, and four cases of superficial infection. Patients with high CCI were more likely to acquire superficial infections (p=0.264, OR=3.857). There were no deep infections, periprosthetic fractures, nail breakages, non-unions.

TTC nailing is an effective treatment methodology for low-demand geriatric patients with fragility ankle fractures. This technique leads to low complication rates and early mobilisation. It is not a life-changing procedure, with many able to return to their pre-operative mobility status, which is important for preventing the loss of socioeconomic independence.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 760 - 766
1 Jul 2001
Suzuki H Takahashi K Yamagata M Shimizu S Moriya H Yamazaki M

We have examined the process of fusion of the intertransverse processes and bone graft in the rabbit by in situ hybridisation and evaluated the spatial and temporal expression of genes encoding pro-α1 (I) collagen (COL1A1), pro-α1 (II) collagen (COL2A1) and pro-α1 (X) collagen (COL10A1). Beginning at two weeks after operation, osteogenesis and chondrogenesis occurred around the transverse process and the grafted bone at the central portion of the area of the fusion mass. Osteoblasts and osteocytes at the newly-formed woven bone expressed COL1A1. At the cartilage, most chondrocytes expressed COL2A1 and some hypertrophic chondrocytes COL10A1. In some regions, co-expression of COL1A1 and COL2A1 was observed. At four weeks, such expressions for COL1A1, COL2A1 and COL10A1 became prominent at the area of the fusion mass. From four to six weeks, bone remodelling progressed from the area of the transverse processes towards the central zone. Osteoblasts lining the trabeculae expressed a strong signal for COL1A1. At the central portion of the area of the fusion mass, endochondral ossification progressed and chondrocytes expressed COL2A1 and COL10A1. Our findings show that the fusion process begins with the synthesis of collagens around the transverse processes and around the grafted bone independently. Various spatial and temporal osteogenic and chondrogenic responses, including intramembranous, endochondral and transchondroid bone formation, progress after bone grafting at the intertransverse processes. Bone formation through cartilage may play an important role in posterolateral spinal fusion


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 289 - 294
1 Mar 2002
Phillips FM Reuben J Wetzel FT

Our study establishes a rabbit model of disc degeneration which requires neither a chemical nor physical injury to the disc. Disc degeneration similar to that seen in man was created at levels proximal (L4-L5) and caudal (L7-S1) to a simulated lumbar fusion and was studied for up to nine months after arthrodesis. Loss of the normal parallel arrangement of collagen bundles within the annular lamellae was observed in intervertebral discs adjacent to the fusion at three months. By six months there was further disorganisation as well as loss of distinction between the lamellae themselves. By nine months the structure of the disc had been replaced by disorganised fibrous tissue, and annular tears were seen. There was an initial cellular proliferative response followed by loss of chondrocytes and notochordal cells in the nucleus pulposus. Degeneration was accompanied by a decrease in the monomer size of proteoglycans. Narrowing of the disc space, endplate sclerosis and the formation of osteophytes at adjacent disc spaces were observed radiologically