Introduction: We compared
The aims of this study were to report functional
outcomes of salvage procedures for patients with cerebral palsy (CP)
who have chronic dislocation of the hip using validated scoring
systems, and to compare the results of three surgical techniques. We reviewed 37 patients retrospectively. The mean age at the
time of surgery was 12.2 years (8 to 22) and the mean follow-up
was 56 months (24 to 114). Patients were divided into three groups:
14 who underwent proximal femoral resection arthroplasty (PFRA group
1), ten who underwent subtrochanteric valgus osteotomy (SVO group 2),
and 13 who underwent subtrochanteric valgus osteotomy with resection
of the femoral head (SVO with FHR group 3). All patients were evaluated
using the Caregiver Priorities and Child Health Index of Life with
Disabilities (CPCHILD) and the Pediatric Quality of Life Inventory
(PedsQL). Significant improvements occurred in most CPCHILD and PedsQL
subsection scores following surgery in all patients, without significant
differences between the groups. There were 12 post-operative complications.
Less severe complications were seen in group 1 than in groups 2
and 3. Salvage surgery appears to provide pain relief in patients with
CP who have painful chronic dislocation of the hip. The three salvage
procedures produced similar results, however, we recommend the use
of PFRA as the complications are less severe. Take home message: Salvage surgery can be of benefit to patients
with CP with chronic painful hip dislocation, but should be limited
to selected patients considering complications. Cite this article:
Introduction. Patient-specific cutting guides entered into clinical practice few years ago, first introduced in total knee replacement and recently also for other joint replacements. Advantages claimed are improving accuracy and repeatability in implant placement. New patient-specific guides to perform an accurate femoral neck resection and provide a precise alignment reference for acetabular reaming in total hip arthroplasty (THA) were recently developed by Medacta International: MyHip Technology. To date femoral guides can be designed for both anterior and posterior approaches, whereas acetabular guides are available only for posterior approach. Evaluation of the repeatability and reproducibility of MyHip guides placement on cadavers is performed using a navigation system. Accuracy of femoral MyHip guides is evaluated also through one author's clinical experience (RP). Materials and Methods. During each cadaveric session one body (2 hips) was available. A pre-operative CT scan has been obtained and used in order to create the 3D bone model of the pelvis and proximal femurs. Afterwards, a surgical planning for THA has been performed for each case, and, once it was approved by the surgeons, the designed patient-specific blocks were made. Intraobserver and interobserver agreement in positioning the guides was assessed getting measures of
Direct anterior approach (DAA) is an inter-muscular approach that needs no muscle detached. In THA through DAA approach, exposure of the acetabulum is facilitated, while the key points of this approach are femoral lift-up and hip extension to get sufficient access to the femoral canal. To investigate the strategy for femoral lift-up, we released the capsule step by step and measured the distance of femoral lift-up at each step in cadavers and clinical cases. The effects of hip extension on femoral lift-up were also evaluated. Three fresh frozen cadavers were used. In supine position, the hip joint was exposed through DAA by two experienced surgeons. After anterior capsulotomy and
In order to enhance the acceptance of computer assisted surgery in joint replacement, a development-cooperation with BrainLAB, Germany was set up to develop a user-friendly handheld navigation device. A sterile draped Apple® IPod-Touch which is placed into a hardcover cradle, is used as navigation monitor and touchscreen control. Different instruments, such as navigation-pointer are attached to the cradle. In addition the workflows for TKR and THR procedures have been optimised. Therefore the main focus for TKR is navigation of femoral and tibial resection as well as leg alignment control. For the THR the system enables an intraoperative control of leg-length and femoral-offset measurement in comparison with the preoperative situation. Each step of the procedure is supported by video animations of the specific navigation workflow. Between September and December 2010 the first clinical study on the usability in TKR and THR was performed for 20 cases using a prototype system. The study was approved by the local ethic committee and the “German Federal Institute for Drugs and Medical Devices (BfArM)”. Special interest was taken to the aspects of usability and the necessary time periods for specific steps of the procedure. Usability was measured for specific time periods of the procedure assessment of the usability of the surgical team. In addition postoperative x-rays were evaluated for implant position, leg alignment for TKR and hip joint geometry for THR cases. Throughout the study for each assigned patient the procedure could be performed as planned. Several design inputs were identified for further improvement of the final system. Therefore time measurements of the first five cases were excluded. For the TKR cases the registration process of the last 5 cases was less than 3 minutes. The interval for the tibial resection was between 3 and 7 minutes (aligning tibial cutting block – end of tibial verification). The interval for the distal femur resection was between 7 and 11 minutes (aligning femoral cutting block – end of femoral verification). All 10 Patients showed a final leg alignment on the postoperative standing x-ray within the save-zone of +/− 3° from neutral alignment. For the THR cases the preoperative registration period including the
Severe femoral head deformities due to Perthes' disease are characterized by limitation of ROM, pain, and early degeneration, eventually becoming intolerable already in early adulthood. Morphological adaptation of the acetabulum is substantial and complex intra- and extraarticular impingement sometimes combined with instability are the underlying pathologies. Improvement is difficult to achieve with classic femoral and acetabular osteotomies. Since 15 years we have executed a head size reduction. With an experience of more than 50 cases no AVN of the femoral head was recorded. In two hips fracture of the medial column of the neck has been successfully treated with subsequent screw fixation. The clinical mid-term results are characterized by substantial increase of hip motion and pain reduction. Surgical goal is to obtain a smaller head, well contained in the acetabulum. It should become as spherical as possible and the gliding surface should be covered with best available cartilage. Together, it has to be accomplished under careful consideration of the blood supply to the femoral head. In the majority of cases acetabular reorientation is necessary to optimize joint stability.
Hip displacement, common in patients with cerebral palsy (CP), causes pain and hinders adequate care. Hip reconstructive surgery (HRS) is performed to treat hip displacement; however, only a few studies have quantitatively assessed femoral head sphericity after HRS. The aim of this study was to quantitatively assess improvement in hip sphericity after HRS in patients with CP. We retrospectively analyzed hip radiographs of patients who had undergone HRS because of CP-associated hip displacement. The pre- and postoperative migration percentage (MP), femoral neck-shaft angle (NSA), and sphericity, as determined by the Mose hip ratio (MHR), age at surgery, Gross Motor Function Classification System level, surgical history including Dega pelvic osteotomy, and triradiate cartilage status were studied. Regression analyses using linear mixed model were performed to identify factors affecting hip sphericity improvement.Aims
Methods
Purpose of the study: During resurfacing arthroplasty, excessive valgus of the femoral neck or an insufficient surgical technique can lead to formation of a notch in the femoral head. Although the mechanisms weakening the femoral neck and subsequent fractures are well described, the effects of altered blood supply via the retinacular vessels on potential ischemia of the femoral head are largely unknown. The purpose of our study was to assess blood supply to the femoral head when a notch occurred in the femoral neck during total hip replacement surgery and to deduct possible implications concerning the resurfacing procedure. Material and methods: Blood supply to the femoral head was measured with laser Doppler fluorometry in 14 hips undergoing total hip replacement for osteoarthritis via a lateral approach with anterior dislocation. An optical laser probe for the fluorometry (Moor Instruments, Wilmington Delewar, 20 mW laser, probe length 780 nm) was introduced via a 3.5 mm hole drilled in the antrolaeral quadrant of the femoral head (leg in neutral position). The position of the probe was checked on the x-ray of the
The June 2014 Children’s orthopaedics Roundup360 looks at: plaster wedging in paediatric forearm fractures; the medial approach for DDH; Ponseti – but not as he knew it?; Salter osteotomy more accurate than Pemberton in DDH; is the open paediatric fracture an emergency?; bang up-to-date with femoral external fixation; indomethacin, heterotopic ossification and cerebral palsy hips; lengthening nails for congenital femoral deformities, and is MRI the answer to imaging of the physis?
In patients with severe quadriplegic cerebral palsy and painful hip dislocation proximal femoral resection arthroplasty can reduce pain, but the risk of heterotopic ossification is significant. We present a surgical technique of autologous capping of the femoral stump in order to reduce this risk, using the resected femoral head as the graft. A retrospective study of 31 patients (43 hips) who had undergone proximal femoral resection arthroplasty with (29 hips) and without autologous capping (14 hips) was undertaken. Heterotopic ossification was less frequent in patients with autologous capping, and a more predictable pattern of bony overgrowth was found. For a selected group of non-ambulatory patients with long-standing painful dislocation of the hip, we recommend femoral resection arthroplasty over more complicated reconstructive operations. The risk of heterotopic ossification, which is a major disadvantage of this operation, is reduced by autologous capping.
The clinical and radiological results of 50 consecutive acetabular reconstructions in 48 patients using impaction grafting have been retrospectively reviewed. A 1:1 mixture of frozen, ground irradiated bone graft and Apapore 60, a synthetic bone graft substitute, was used in all cases. There were 13 complex primary and 37 revision procedures with a mean follow-up of five years (3.4 to 7.6). The clinical survival rate was 100%, with improvements in the mean Harris Hip Scores for pain and function. Radiologically, 30 acetabular grafts showed evidence of incorporation, ten had radiolucent lines and two acetabular components migrated initially before stabilising. Acetabular reconstruction in both primary and revision surgery using a 1:1 mixture of frozen, ground, irriadiated bone and Apapore 60 appears to be a reliable method of managing acetabular defects. Longer follow-up will be required to establish whether this technique is as effective as using fresh-frozen allograft.
A clinical and radiological study was conducted on 97 total hip replacements performed for congenital hip dislocation in 79 patients between 1989 and 1998 using a three-dimensional custom-made cementless stem. The mean age at operation was 48 years (17 to 72) and the mean follow-up was for 123 months (83 to 182). According to the Crowe classification, there were 37 class I, 28 class II, 13 class III and 19 class IV hips. The mean leg lengthening was 25 mm (5 to 58), the mean pre-operative femoral anteversion was 38.6° (2° to 86°) and the mean correction in the prosthetic neck was −23.6° (−71° to 13°). The mean Harris hip score improved from 58 (15 to 84) to 93 (40 to 100) points. A revision was required in six hips (6.2%). The overall survival rate was 89.5% (95% confidence interval 89.2 to 89.8) at 13 years when two hips were at risk. This custom-made cementless femoral component, which can be accommodated in the abnormal proximal femur and will correct the anteversion and frontal offset, provided good results without recourse to proximal femoral corrective osteotomy.