Aims. Precise implant positioning, tailored to individual spinopelvic biomechanics and phenotype, is paramount for stability in total hip arthroplasty (THA). Despite a few studies on instability prediction, there is a notable gap in research utilizing artificial intelligence (AI). The objective of our pilot study was to evaluate the
Aims. This study aims to assess the
Objectives. The number of surgical procedures performed each year to treat
femoroacetabular impingement (FAI) continues to rise. Although there
is evidence that surgery can improve symptoms in the short-term,
there is no evidence that it slows the development of osteoarthritis
(OA). We performed a
Studies have shown that 10–30% patients do not achieve optimal function outcomes after total hip replacement (THR). High quality randomised controlled trials (RCTs) evaluating the clinical and cost-effectiveness of techniques to improve functional outcomes after THR are lacking. We performed this study to evaluate the
Current treatment options for displaced acetabular fractures in elderly patients include non-surgical management, surgical fixation and surgical fixation with simultaneous hip replacement, the so-called “fix-and-replace”™. There remains a paucity of evidence to guide surgeons in decision making for these difficult injuries. The aim of this study was to assess the
Aims. Perthes’ disease is an uncommon hip disorder with limited data on the long-term outcomes in adulthood. We partnered with community-based foundations and utilized web-based survey methodology to develop the Adult Perthes Survey, which includes demographics, childhood and adult Perthes’ disease history, the University of California Los Angeles (UCLA) Activity Scale item, Short Form-36, the Hip disability and Osteoarthritis Outcome Score, and a body pain diagram. Here we investigate the following questions: 1) what is the
Aims. Computer-assisted 3D preoperative planning software has the potential to improve postoperative stability in total hip arthroplasty (THA). Commonly, preoperative protocols simulate two functional positions (standing and relaxed sitting) but do not consider other common positions that may increase postoperative impingement and possible dislocation. This study investigates the
Aims. Type 2 diabetes mellitus (T2DM) impairs bone strength and is a significant risk factor for hip fracture, yet currently there is no reliable tool to assess this risk. Most risk stratification methods rely on bone mineral density, which is not impaired by diabetes, rendering current tests ineffective. CT-based finite element analysis (CTFEA) calculates the mechanical response of bone to load and uses the yield strain, which is reduced in T2DM patients, to measure bone strength. The purpose of this
The purposes of this study were to evaluate the accuracy and
Aims. The objectives of this study were to investigate the patient characteristics and mortality of Vancouver type B periprosthetic femoral fractures (PFF) subgroups divided into two groups according to femoral component stability and to compare postoperative clinical outcomes according to treatment in Vancouver type B2 and B3 fractures. Methods. A total of 126 Vancouver type B fractures were analyzed from 2010 to 2019 in 11 associated centres' database (named TRON). We divided the patients into two Vancouver type B subtypes according to implant stability. Patient demographics and functional scores were assessed in the Vancouver type B subtypes. We estimated the mortality according to various patient characteristics and clinical outcomes between the open reduction internal fixation (ORIF) and revision arthroplasty (revision) groups in patients with unstable subtype. Results. The one-year mortality rate of the stable and unstable subtype of Vancouver type B was 9.4% and 16.4%. Patient demographic factors, including residential status and pre-injury mobility were associated with mortality. There was no significant difference in mortality between patients treated with ORIF and Revision in either Vancouver B subtype. Patients treated with revision had significantly higher Parker Mobility Score (PMS) values (5.48 vs 3.43; p = 0.00461) and a significantly lower visual analogue scale (VAS) values (1.06 vs 1.94; p = 0.0399) for pain than ORIF in the unstable subtype. Conclusion. Among patients with Vancouver type B fractures, frail patients, such as those with worse scores for residential status and pre-injury mobility, had a high mortality rate. There was no significant difference in mortality between patients treated with ORIF and those treated with revision. However, in the unstable subtype, the PMS and VAS values at the final follow-up examination were significantly better in patients who received revision. Based on postoperative activities of daily life, we therefore recommend evision in instances when either treatment option is
Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The
There is still no clear consensus regarding which cup position might provide better functional performance for developmental dysplasia of the hip (DDH). This study aimed to evaluated the
Mixed Reality has the potential to improve accuracy and reduce required dissection for the performance of peri-acetabular osteotomy. The current work assesses initial proof of concept of MR guidance for PAO. A PAO planning module, based on preoperative computed tomography (CT) imaging, allows for the planning of PAO cut planes and repositioning of the acetabular fragment. 3D files (holograms) of the cut planes and native and planned acetabulum positions are exported with the associated spatial information. The files are then displayed on mixed reality head mounted device (HoloLens2, Microsoft) following intraoperative registration using an FDA-cleared mixed reality application designed primary for hip arthroplasty (HipInsight). PAO was performed on both sides of a bone model (Pacific Research). The osteotomies and acetabular reposition were performed in accordance with the displayed holograms. Post-op CT imaging was performed for analysis. Cutting plane-accuracy was evaluated using a best-fit plane and 2D angles (°) between the planned and achieved supra (SA)- and retroacetabular (RA) osteotomy and retroacetabular and ischial osteotomies (IO) were measured. To evaluate the accuracy of acetabular reorientation, we digitized the acetabular rim and calculated the acetabular opening plane. Absolute errors of planned and achieved operative inclination and anteversion (°) of the acetabular fragment, as well as 3D lateral-center-edge (LCE) angles were calculated. The mean absolute difference between the planned and performed osteotomy angles was 3 ± 3°. The mean absolute error between planned and achieved operative anteversion and inclination was 1 ± 0° and 0 ± 0° respectively. Mean absolute error between planned and achieved 3D LCE angle was 0.5 ± 0.7°. Mixed-reality guidance for the performance of pelvic osteotomies and acetabular fragment reorientation was
Dislocation after total hip replacement (THR) is a devastating complication. Risk factors include patient and surgical factors. Mitigation of this complication has proven partially effective. This study investigated a new innovating technique to decrease this problem using rare earth magnets. Computer simulations with design and magnetic finite element analysis software were used to analyze and quantitate the forces around hip implants with embedded magnets into the components during hip range of motion. N52 Neodymium-Iron-Boron rare earth magnets were sized to fit within the existing acetabular shells and the taper of a hip system. Additionally, magnets placed within the existing screw holes were studied. A 50mm titanium acetabular shell and a 36mm ceramic liner utilizing a taper sleeve adapter were modeled which allowed for the use of a 12mm × 5mm magnet placed in the center hole, an 18mm × 15mm magnet within the femoral head, and 10mm × 5mm magnets in the screw holes. Biomechanical testing was also performed using in-vitro bone and implant models to determine retention forces through a range of hip motion. The novel system incorporating magnets generated retentive forces between the acetabular cup and femoral head of between 10 to 20 N through a range of hip motion. Retentive forces were stronger at the extreme position hip range of motion when additional magnets were placed in the acetabular screw holes. Greater retentive forces can be obtained with specially designed femoral head bores and acetabular shells specifically designed to incorporate larger magnets. Mechanical testing validated the loads obtained and demonstrated the
Genetic skeletal disorders constitute a rare and heterogeneous bone diseases often leading to poor quality of life. Several surgical options are available. The surgeon must deal with specific features (bone deformity, previous procedures, abnormal bone quality, stiffness or instability, muscle weakness). The questions concern the
Arthroplasties are widely performed to improve mobility and quality of life for symptomatic knee/hip osteoarthritis patients. With increasing rates of Total Joint Replacements in the United Kingdom, predicting length of stay is vital for hospitals to control costs, manage resources, and prevent postoperative complications. A longer Length of stay has been shown to negatively affect the quality of care, outcomes and patient satisfaction. Thus, predicting LOS enables us to make full use of medical resources. Clinical characteristics were retrospectively collected from 1,303 patients who received TKA and THR. A total of 21 variables were included, to develop predictive models for LOS by multiple machine learning (ML) algorithms, including Random Forest Classifier (RFC), K-Nearest Neighbour (KNN), Extreme Gradient Boost (XgBoost), and Na¯ve Bayes (NB). These models were evaluated by the receiver operating characteristic (ROC) curve for predictive performance. A feature selection approach was used to identify optimal predictive factors. Based on the ROC of Training result, XgBoost algorithm was selected to be applied to the Test set. The areas under the ROC curve (AUCs) of the 4 models ranged from 0.730 to 0.966, where higher AUC values generally indicate better predictive performance. All the ML-based models performed better than conventional statistical methods in ROC curves. The XgBoost algorithm with 21 variables was identified as the best predictive model. The feature selection indicated the top six predictors: Age, Operation Duration, Primary Procedure, BMI, creatinine and Month of Surgery. By analysing clinical characteristics, it is
Displaced acetabular fractures in the older patient present significant treatment challenges. There is evidence the morbidity and mortality associated is similar to the fractured neck of femur cohort. Despite growing literature, there remains significant controversy regarding treatment algorithms; varying between conservative management, to fracture fixation and finally surgical fixation and simultaneous THA to allow immediate full weight bearing. £250k NIHR, Research for Patient Benefit (Ref: PB-PG-0815-20054). Trial ethical approval (17/EE/0271). After national consultation, 3 arms included; conservative management, fracture fixation and simultaneous fracture fixation with THA. Statistical analysis required minimum 12 patients/3 arms to show
Waiting times for arthroplasty surgery in Northern Ireland are among the longest in the National Health Service, which have been further lengthened by the onset of the SARS-CoV-19 global pandemic in March 2020. The Department of Health (DoH) in Northern Ireland has announced a new Elective Care Framework (ECF), with the framework proposing that by March 2026 no patient will wait more than 52 weeks for inpatient/day case treatment. We aimed to assess the
Introduction. MAVRIC-SL (MVSL), a multi-spectral magnetic resonance imaging (MRI) sequence [1] used for visualization of tissues near hip arthroplasty, can be accelerated by a short calibration scan [2], permitting an isotropic acquisition in a clinically
Aims. This