Introduction. Plate fixation for distal femoral fractures is a commonly used method of fracture stabilisation. Many orthopaedic surgeons traditionally do not allow their patients to weight bear for the first 6 weeks after surgery, fearing of loss of fracture reduction and metalwork failure. The aim of this study is to investigate whether the post-operative weight bearing status after plate fixation influences the outcome in terms of loss of reduction and metalwork failure. Materials & Methods. A retrospective data collection from all patients who treated in our hospital surgically for distal femoral fractures, from January 2015 until June 2017. Inclusion criteria were the operative treatment of these fractures with plate fixation. Patients who were treated with retrograde nail, primary total knee replacement or screw fixation were excluded from the study. Patient, injury and surgery demographic data was collected. The immediate post-operative weight bearing status of these patients was noted. Weight bearing status was divided into two groups – Group 1 (Non and touch weight bear – the non-weight bearing group) and Group 2 (Weight bear as tolerated / Full weight bear – the weight bearing group). Radiological data about fracture displacement or metalwork failure was collected at the six weeks and three months follow up after the operation, using a standardised measurement for displacement performed independently by two authors (EI, TA). Results. Of 70 patients, a total of 51 fractures treated with plate fixation were included to the study. The mean age of the cohort was 64.3 ±20.7 years with the majority of the patients being female (63%). Most of the patients (40%) had a complete articular distal femoral fracture, AO Type 33C. Thirty-nine patients (76%) were treated with one lateral
The aim of the study was to describe the failure rate of locking plates used for internal fixation of distal femoral fractures and to identify independent predictors of failure. A consecutive series of 147 patients presenting to the study unit during an 8 year period with a distal femoral fracture were identified from a prospectively compiled trauma database. There were 117 females and 30 males, with a mean age of 70.7 years (13 to 99 years), of which 77 were periprosthetic fractures and 70 were supracondylar fractures around native knees. There were 35 failures of fixation. The commonest cause was non-union (n=31). The survival of the plate 2 years post-surgery was 74percnt; (95percnt; CI 64percnt; to 84percnt;), which remained static to a mean follow of 5 years. There was no difference in failure of fixation according to gender (p=0.32) or if there was a periprosthetic fracture (p=0.8). Younger age (61.8 vs. 73.6 years, p=0.004), increasing level of comorbidity (p=0.02), and fracture comminution (p=0.001) were all significant predictors of failure of fixation. Cox regression analysis confirmed younger age (p=0.04), increasing comorbidity (p=0.002), and fracture comminution (p=0.002) as independent predictors of failure of fixation and non-union after adjusting for confounding. The failure of locking plates for distal femoral fractures occurs in more than one in five patients. The independent predictors could be used to identify those patients at greatest risk of failure of the locking plate, who may benefit from alternative methods of fixation, primary bone grafting, or interventions that may aid union.
The purpose of this study was to determine the weightbearing practice of operatively managed fragility fractures in the setting of publically funded health services in the UK and Ireland. The Fragility Fracture Postoperative Mobilisation (FFPOM) multicentre audit included all patients aged 60 years and older undergoing surgery for a fragility fracture of the lower limb between 1 January 2019 and 30 June 2019, and 1 February 2021 and 14 March 2021. Fractures arising from high-energy transfer trauma, patients with multiple injuries, and those associated with metastatic deposits or infection were excluded. We analyzed this patient cohort to determine adherence to the British Orthopaedic Association Standard, “all surgery in the frail patient should be performed to allow full weight-bearing for activities required for daily livingAims
Methods
Fractures of the distal femur can be challenging to manage and
are on the increase in the elderly osteoporotic population. Management
with casting or bracing can unacceptably limit a patient’s ability
to bear weight, but historically, operative fixation has been associated
with a high rate of re-operation. In this study, we describe the outcomes
of fixation using modern implants within a strategy of early return
to function. All patients treated at our centre with lateral distal femoral
locking plates (LDFLP) between 2009 and 2014 were identified. Fracture
classification and operative information including weight-bearing
status, rates of union, re-operation, failure of implants and mortality
rate, were recorded.Aims
Patients and Methods
Periprosthetic femur fracture (PPF) are heterogeneous, complex, and thought to be increasingly prevalent. The aims were to evaluate PPF prevalence, casemix, management, and outcomes. This nationwide study included all PPF patients aged >50 years from 16 Scottish hospitals in 2019. Variables included: demographics; implant and fracture factors; management factors, and outcomes. There were 332 patients, mean age 79.5 years, and 220/332 (66.3%) were female. One-third (37.3%) were ASA1-2 and two-thirds (62.3%) were ASA3+, 91.0% were from home/sheltered housing, and median Clinical Frailty Score was 4.0 (IQR 3.0). Acute medical issues featured in 87/332 (26.2%) and 19/332 (5.7%) had associated injuries. There were 251/332 (75.6%) associated with a proximal femoral implant, of which 232/251 (92.4%) were arthroplasty devices (194/251 [77.3%] total hip, 35/251 [13.9%] hemiarthroplasty, 3/251 [1.2%] resurfacing). There were 81/332 (24.4%) associated with a
Aims. Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on
We hypothesised that an independent Notch Trial is essential on the same lines as other Component Trials-Femoral, Tibial and Patellar - in posterior stabilised total knee arthroplasty. Therefore we evolved Notch Trial to visually ascertain the adequacy of intercondylar resection and eliminate the possibility of femoral intercondylar fractures. We undertook a retrospective study to evaluate Notch Trial by the frequency of the need to remove osteophytes or file uneven surfaces in intercondylar resection by using the detachable box part of the trial femoral component, assess occurrence of
The objective of this study was to compare differences in alignment following robotic arm-assisted bi-unicompartmental knee arthroplasty (Bi-UKA) and conventional total knee arthroplasty (TKA). This was a prospective, randomised controlled trial of 70 patients. 39 TKAs were implanted manually, as per standard protocol at our institution, and 31 Bi-UKA patients simultaneously received fixed-bearing medial and lateral UKAs, implanted using robotic arm-assistance. Preoperative and 3-month postoperative CT scans were analysed to determine hip knee ankle angle (HKAA), medial
The aim of this study was to describe the management and associated outcomes of patients sustaining a femoral hip periprosthetic fracture (PPF) in the UK population. This was a multicentre retrospective cohort study including adult patients who presented to 27 NHS hospitals with 539 new PPFs between 1 January 2018 and 31 December 2018. Data collected included: management strategy (operative and nonoperative), length of stay, discharge destination, and details of post-treatment outcomes (reoperation, readmission, and 30-day and 12-month mortality). Descriptive analysis by fracture type was performed, and predictors of PPF management and outcomes were assessed using mixed-effects logistic regression.Aims
Methods
The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR). Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.Aims
Methods
Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes. In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes.Aims
Methods
Background:. Septic arthritis following intra-capsular penetration of the knee by external fixation devices is a complication of traction/fixation devices. This study aimed to demonstrate the capsular attachments and reflections of the distal femur to determine safe placements of wires. Methods:. The attachments of the capsule to the distal femur were measured in cadaveric knees. Medially and laterally measurements were expressed as percentages related to the maximal AP diameter of the distal femur. Results:. Mean distance of the anterior attachment was 79.5mm (Range 48.1–120.7mm). The medial capsular reflections were attached an average of 57% back from the anterior edge (Range 41–74%). Laterally the capsular reflections were attached an average of 48% from the anterior reference point (Range 33–57%). Discussion:. Capsular reflections varied. Medially the capsule attachment was up to 74% of diameter of distal femur at the level of the adductor tubercle. Therefore, the insertion of
The 8-plate (Orthofix, SRL, Italy) is a titanium extraperiosteal plate with 2 screws which acts as a hinge at the outer limits of the physis. It has been used for correction of both angular and sagittal deformity around the knee. To our knowledge this is the first study describing the use of 8-plates in leg length discrepancy (LLD) correction. We aimed to evaluate outcomes of temporary 8-plate epiphysiodesis in LLD, and to assess the complications associated with its usage. This retrospective study included 30 patients between 2007 and 2010 whom underwent 8-plate epiphysiodesis to address LLD. Leg length measurements were recorded using erect full leg length scanograms and comparison made between pre-operative, interval and final scanograms. Any deviations of the mechanical axis were also recorded. During the study period 34 epiphysiodeses were performed on 30 patients. There were 17 males and 14 females. The average age at the time of procedure was 10.7 years (range 3–15). Average time to final follow-up was 24 months (range 52–10). The average pre-operative LLD was 2.5 cm (range 1.5–6 cm). The mean overall rate of correction was 1.0 cm per year. The mean residual LLD at end of treatment was 1.1 cm (range 0–4.5 cm). Two patients experienced genu recurvatum deformity. This was associated with placement of
We present our results of cementless total hip arthroplasty with a tapered, rectangular stem made of titanium-aluminum-niobium alloy. This implant is used since 1979 with only minor modifications. The design of the femoral component achieves primary stability through precision rasping and press-fit implantation. Between October 1986 and November 1987, two hundred consecutive patients (208 hips) underwent total hip arthroplasty with this tapered, rectangular stem. In all cases the acetabular component was a threaded cup made of titanium. At a minimum follow-up of twenty years eighty-seven patients were still alive. Sixty-seven patients (69 hips) were available for clinical and radiographic follow-up. The probability of survival of the stem was 0.96 (95% confidence interval, 0.91 to 0.98) and that of the cup was 0.72 (0.62 to 0.80). The probability of survival of both the stem and the acetabular component with revision for any reason as the end point was 0.71 (0.61 to 0.78). Two stems have been revised due to aseptic loosening. We found various degrees of osteolysis around the acetabular and femoral component (61,7%). At the time of the 20-year follow-up no stem was deemed at risk for loosening. The key findings of our twenty-year follow-up are the very low rate of revisions of the femoral component and the low rate of
Background. In poliomyelitis; hand to knee gait is the sum of quadriceps weakness and fixed knee flexion deformity. Limb shortening is another added problem. Usually, each problem is attacked separately; with variable end results and complication rates for each procedure. Patients and methods. 22 patients (16–46 y.); with poliomyelitis with hand to knee gait due to fixed knee flexion deformity of mild to moderate degree (10–400); and limb shortening of 4.5–9.5 cm., were managed simultaneously by a single operation. A
The reconstruction of lower limb defects after oncological reconstructions is still a problem in limb salvage surgery. Large bony defects need to be treated with sound and durable reconstructions. During recent decades, the life expectancy of patients affected with cancer has improved considerably because of advances in chemotherapy, immunotherapy, hormonal treatment and radiotherapy. This improvement requires greater reliability in the reconstructive procedure in order to avoid mechanical failure during prolonged survival of the patient. The author experience with modular megaprosthesis by Link (megasystem C) allowed us to present a rapid, effective and functional solution. From June 2001 to December 2007 225 patients have been operated with a megaprosthesis C for tumoral resection. The new megaprosthesis C by Link represents a wide-ranging system that can afford a large variety of reconstructions in the inferior limb, from very short replacement of 5 cm in proximal femur, to a total femur and proximal tibia replacement. Modularity is represented by 1 cm increase in length. The different options of cemented and not cemented stem may be used with intraoperative decision. In cemented stem a rough collar seals the osteotomy and prevents polyethylene debris from entering the femoral canal by inducing a scar tissue around the stem entrance (so-called purse-string effect). Moreover in patients with solitary lesions and very good prognosis an allograft-prosthesis composite can be performed with improved clinical results on walking and function. Of the 225 patients that underwent tumoral resection and reconstruction with a modular megaprosthesis approximately 43% (97 cases) were operated for metastatic disease. Among these cases 55 cases were proximal femoral recontructions, 39 cases were
Femoral lengthening has been associated with narrowing of the joint space at the hip. We have studied the joint space before lengthening in 20 patients with a short femur due to a femoral-shaft fracture (15) or
Introduction. Malrotation following total knee replacement is directly related to poor outcome. The knowledge of proximal and distal rotational axes and angles of the femur is therefore of high importance. The aim of the study was to determine whether the most used proximal and
Background. Adequate rotation of femoral component in total knee arthroplasty(TKR) is mandatory for preventing numerous adverse sequelae. The transepicondylar axis has been a well-accepted reference for femoral component rotation in the measured resection technique. In this technique, measured resection is performed referenced off the tibial cut - perpendicular to the tibial mechanical axis with the knee in 90 ° of flexion. However, to the best of our knowledge, it is not known whether this technique apply well to a knee with tibia vara. This study evaluates the reliability of the transepicondylar axis as a rotational landmark in knees with tibia vara. Methods. We selected 101 osteoarthritis knees in 84 symptomatic patients(mean age: 69.24 ± 5.68) with proximal tibia vara (Group A). Group A was compared with 150 osteoarthritic knees without tibia vara in 122 symptomatic patients (mean age: 69.51 ± 6.01) (Group B). The guide line for selection of all these knees were based on the degree of tibia vara angle (TVA) which was formed by line perpendicular to epiphysis and by anatomical axis of the tibia - all measured in radiographs of the entire lower limb. Magnetic resonance imaging (MRI) axial images with most prominent part of both femoral condyles were used for measurement of transepicondylar axis(TE), anteroposterior axis(AP) and posterior condylar axis(PC). Results. The mean TVA of group A was 8.94° ± 3.11 and group B was 1.24° ± 0.85. The TE line in Group A showed 6.09 ° ± 1.43 of external rotation, relative to PC. This did not show statistical difference compared with 5.95 ° ± 1.58 in Group B (p=0.4717). The AP line in Group A showed 6.06 ° ± 1.93 of external rotation, relative to the line perpendicular to PC. This was statistically significant when compared to 5.44 ° ± 2.13 in Group B (p=0.020). Conclusion. There is no difference between knees without tibia vara compared those with tibia vara with regards to transepicondylar axis. In addition, both groups have almost identical external rotation of approximately 6 °. The AP axis was only approximately 0.5 ° difference between the two groups. The
Background. Computer-assisted navigation systems for total knee arthroplasty (TKA) were introduced to improve implantation accuracy and to optimize ligament balancing. Several comparative studies in the literature confirmed an effect on the component position and other studies could not confirm these results. For ligament balancing most studies found no significant influence on the clinical outcome using a navigation system for TKA. In the literature there were no reports of mid-term results after navigated TKA. With our study we wanted to show if the use of a navigation system for TKA will have an influence on the component's position and on the clinical results at 5-year follow up. Methods. We enrolled 200 patients in a prospective randomized study with a minimum follow up of 5 years. 100 TKA were operated on without using a navigation system (Group A) and 100 surgeries (Group B) were done with computer assistance. Radiological investigation by standard radiographs including a long-leg X-ray was performed with a follow up rate in Group A of 86.2% versus 80.2% in Group B. We measured the mechanical axis of the leg, lateral