Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 10 - 10
1 Dec 2022
Behman A Bradley C Maddock C Sharma S Kelley S
Full Access

There is no consensus regarding the optimum frequency of ultrasound for monitoring the response to Pavlik harness (PH) treatment in developmental dysplasia of hip (DDH). The purpose of our study was to determine if a limited-frequency hip ultrasound (USS) assessment in children undergoing PH treatment for DDH had an adverse effect on treatment outcomes when compared to traditional comprehensive ultrasound monitoring. This study was a single-center non-inferiority randomized controlled trial. Children aged less than six months of age with dislocated, dislocatable and stable dysplastic hips undergoing a standardized treatment program with a PH were randomized, once stability had been achieved, to our current standard USS monitoring protocol (every clinic visit) or to a limited-frequency ultrasound protocol (USS only until hip stability and then end of treatment). Groups were compared based on alpha angle at the end of treatment, acetabular indices (AI) and IHDI grade on follow up radiographs at one-year post harness and complication rates. The premise was that if there were no differences in these outcomes, either protocol could be deemed safe and effective. One hundred patients were recruited to the study; after exclusions, 42 patients completed the standard protocol (SP) and 36 completed the limited protocol (LP). There was no significant difference between the mean age between both groups at follow up x-ray (SP: 17.8 months; LP: 16.6 months; p=0.26). There was no difference between the groups in mean alpha angle at the end of treatment (SP: 69°; LP: 68.1°: p=0.25). There was no significant difference in the mean right AI at follow up (SP: 23.1°; LP: 22.0°; p=0.26), nor on the left (SP:23.3°; LP 22.8°; p=0.59). All hips in both groups were IHDI grade 1 at follow up. The only complication was one femoral nerve palsy in the SP group. In addition, the LP group underwent a 60% reduction in USS use once stable. We found that once dysplastic or dislocated hips were reduced and stable on USS, a limited- frequency ultrasound protocol was not associated with an inferior complication or radiographic outcome profile compared to a standardized PH treatment pathway. Our study supports reducing the frequency of ultrasound assessment during PH treatment of hip dysplasia. Minimizing the need for expensive, time-consuming and in-person health care interventions is critical to reducing health care costs, improving patient experience and assists the move to remote care. Removing the need for USS assessment at every PH check will expand care to centers where USS is not routinely available and will facilitate the establishment of virtual care clinics where clinical examination may be performed remotely


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_3 | Pages 7 - 7
1 Apr 2019
Sakale H Agrawal AC
Full Access

Incidence of Congenital talipes equino varus [CTEV] is 1 to 2 per 1000 birth, Out of all cases 20% cases are Non-idiopathic. The management of non-idiopathic CTEV, however, continues to be challenging due to Rigidity, Poor skin condition, Bony changes, Vascularity and Associated congenital abnormalities. In recent literature, short term results of Ponseti method for correction of non-idiopathic CTEV have been encouraging. As Ponseti method decreases the severity of deformity and hence decreases the need for extensive surgery. The aim of current study is to evaluate the results of Ponseti method in Non-idiopathic CTEV. Total 7 children below the age of one year with Non idiopathic clubfoot presented to us in the duration of 2013 to 2015 who were treated by us. The cases included are Streeters Dysplasia with congenital constriction rings 3, Arthrogryposis multiplex congenita with Developmental dysplasia of hip 2, Arthrogryposis multiple congenita spina Bifida 1, Pierre Robinson Syndrome with Ichthiosis 1. Initially all the patients treated with Ponseti casting technique and scoring was done using modified pirani scoring. At an average we could correct the foot from Pirani 7 to 2.5 with a relapse in 4 patients. 2 patients were treated again by Ponseti's method with success while treatment was discontinued in 2 feet. We recommended Ponseti's technique in Syndromic clubfoot as an non-surgical initial modality with good results given. The final outcome may depend more on the underlying condition than the CTEV


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_3 | Pages 11 - 11
1 Apr 2019
Syam K Saraogi A Siney P Nagai H WynnJones H Purbach B Kay P
Full Access

Revision total hip arthroplasty (THA) is a challenging scenario following complex primary THA for developmental dysplasia of hip (DDH). Our study envisages the long-term outcomes of revision DDH and the role of lateral structural support in socket fixation in these young patients who may require multiple revisions in their life-time. Hundred and eighteen consecutive cemented revision THAs with minimum follow up of 5 years following primary diagnosis of DDH operated between January 1974 and December 2012 were analysed for their clinical and radiological outcomes. The mean follow-up of 118 patients was 11.0 years (5.1–39.6 years). The Kaplan Mier survivorship at 11 years with end point as revision for any reason was 89.8% (CI 81.1–98.4). Of 118 revisions, 88 acetabular revisions were for aseptic loosening. Out of the acetabular revisions, 21 had pre-existing structural bone grafts from primary surgery, of which only 3 needed structural re-grafting during revision. Amongst the remaining 18 hips, the lateral support from the previous graft facilitated revision with no requirement of additional structural graft. Sixty-three hips did not have any form of grafting during primary operation. Amongst them, 35 had bone grafting in revision surgery (18 structural grafting). This study reports the largest number of revision THAs with primary diagnosis of DDH with the longest follow up. In our experience, the lateral support from the structural graft done in primary operation appears to have provided benefit in subsequent revision socket fixation


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 530 - 530
1 Dec 2013
Sharma RK
Full Access

INTRODUCTION:. Management of developmental dysplasia of hip in adult is challenging and needs more to be understood in terms of ideal implant, position of acetabulum and operative technique. Patient may present very late, usually when osteoarthritic changes develop followed by pain. Operative management is difficult because of hypoplastic femoral medullary canal and shallow acetabulum filled with soft tissues. Altered anatomy of neurovascular structures also pose a risk of being injured during surgery. AIMS:. The goal of this study was to evaluate late results of total hip arthroplasty in adults after a minimum of 5 years follow-up. MATERIAL:. 45 Total hip arthroplasties in 40 patients were performed for painful hip dysplasia between 2003 and 2012. These 45 procedures were performed in 40 patients mean aged 32 +/− 14 years [17–56]. 29 patients (32 hips) were males and 11 patients (13 hips) were females. Non cemented total hip arthroplasty was done in all cases with mean follow up of 6 years. Of the 45 hips, 6 were neglected, dislocated hips with proximal migration of femoral head. In such patients sub-trochanteric osteotomy was done to bring the femoral head up to the level of Acetabulum. 5 patients (5 hips) were lost to follow up; consequently, the functional results were evaluated for 40 hips (35 patients). Harris hip score was used to evaluate the functional and clinical results. RESULTS and CONCLUSION:. Harris hip score improved in all patients. We concluded from this series that total hip replacement should be considered in all patients with painful dysplastic hip. Key words: Developmental Dyplasia Hip, Total Hip Arthroplasty


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 146 - 146
1 Sep 2012
Naqvi G Malik S Adamec O
Full Access

Aim. The aim of this study is to assess the effectiveness of clinic based ultrasound screening by Orthopaedic surgeon for early diagnosis and treatment of developmental dysplasia of hip (DDH) in one stop clinic. Methods. This prospective study included 395 infants (185 male and 210 female) (5.2% of study population) who were referred for screening on the basis of abnormal findings or the presence of risk factors for DDH. Average age was 12.5 weeks (1 day to 15 months). All infants were assessed for risk factors of DDH. Clinical examinations were performed by the senior author followed by ultrasonography of both of the infant's hips, using the Graf's technique. Alpha and beta angles were calculated and hips were classified according to Graf's classification system. Results. Out of 790 hips examined 670 (84.8%) were labelled as normal. 120 (15.1%) hips in 84 patients were diagnosed as dysplastic or dislocated. Clinical examination only detected 39 patients out of 84, sensitivity of 46%. Average age of diagnosis was 12 weeks (3days-11 months). 79 patients were successfully treated with pavlic harness, 2 required traction and 3 were referred for surgical treatment. There were 14 cases of late diagnosis during one year period (> 4 months of age) (1.8/1000). Conclusion. Selective ultrasound screening is effective in early diagnosis of DDH and significantly reduces the duration of non operative treatment as well as the need for surgical intervention but does not completely eliminate late diagnosis of DDH. We find the concept of one stop DDH clinic highly effective and recommend that ultrasound training should be a part of orthopaedic curriculum


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 14 - 14
1 Sep 2012
Ahmad R L. Kerr H Spencer RF
Full Access

There are a growing number of younger patients with developmental dysplasia of hip, proximal femoral deformity and osteonecrosis seeking surgical intervention to restore quality of life, and the advent of ISTCs has resulted in a greater proportion of such cases being referred to existing NHS departments. Bone-saving hip athroplasty is often advocated for younger active patients, as they are potential candidates for subsequent revision arthroplasty. If resurfacing is contraindicated, short bone-conserving stems may be an option. The rationale for short stems in cementless total hip arthroplasty is proximal load transfer and absence of distal fixation, resulting in preserved femoral bone stock and avoidance of thigh pain. We have carried out 17 short stem hip replacements (Mini-hip, Corin Medical, Cirencester, UK) using ceramic bearings in 16 patients since June 2010. There were 14 females and 2 males, with a mean age of 50.1 years (range 35–63 years) at the time of the surgery. The etiology was osteoarthritis in 11, developmental dysplasia in 4, and osteonecrosis of the femoral head in one patient. All operations were performed through a conservative anterolateral (Bauer) approach. These patients are being followed and evaluated clinically with the Harris and Oxford hip scores, with follow-up at 6 weeks, 3 months, and annually thereafter. Initital results have been encouraging in terms of pain relief, restoration of leg length (one of the objectives in cases of shortening) and rage of movement. Radiological assessment has shown restoration of hip biomechanics. Specific techniques are required to address varus, valgus and femoral deformity with leg length inequality. There are two main groups of short stems, those that are neck-preserving and those that do not preserve the femoral neck. The latter group requires traditional techniques for revision. Another feature that differentiates them is the availability of modularity. The device we employed is neck-preserving and available with different neck lengths and offsets, which help in restoration of hip biomechanics. The advantage of such short stems may be preservation of proximal femoral bone stock, decreased stress shielding and the ease of potential revision. Such devices may be a consideration for patients with malformations of the proximal femur. Long-term follow-up will be of value in determining if perceived benefits are realised in practice


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 14 - 14
1 Jul 2012
Islam SU Henry A Khan T Davis N Zenios M
Full Access

Through the paediatric LCP Hip plating system (Synthes GmBH Eimattstrasse 3 CH- 4436 Oberdorff), the highly successful technique of the locking compression plate used in adult surgery, has been incorporated in a system dedicated to pediatrics. We are presenting the outcome of the paediatric LCP hip plating system used for a variety of indications in our institution. We retrospectively reviewed the notes and radiographs of all those children who have had Paediatric LCP Plate for the fixation of proximal femoral osteotomy and proximal femur fractures in our institution, between October 2007 and July 2010, for their clinical progress, mobilization status, radiological healing and any complications. Forty-three Paediatric LCP hip plates were used in forty patients (24 males and 13 females) for the fixation of proximal femoral osteotomies (n=40) and proximal femur fractures (n=3). The osteotomies were performed for a variety of indications including Perthes disease, developmental dysplasia of hip, Cerebral Palsy, Down's syndrome, coxa vara, Leg length discrepancy and previous failed treatment of Slipped Upper Femoral Epiphysis. Twenty-five children were allowed touch to full weight bearing post operatively. Two were kept non-weight bearing for 6 weeks. The remaining 13 children were treated in hip spica due to simultaneous pelvic osteotomy or multilevel surgery for cerebral palsy. All osteotomies and fractures radiologically healed within 6 months (majority [n=40] within 3 months). There was no statistically significant difference (p= 0.45) in the neck shaft angle between the immediately postoperative and final x-rays after completion of bone healing. Among the children treated without hip spica, 1 child suffered a periprosthetic fracture. Of the children treated in hip spica, 2 had pressure sores, 3 had osteoporotic distal femur fractures and 2 had posterior subluxations requiring further intervention. There were no implant related complications. The Paediatric LCP Hip Plate provides a stable and reliable fixation of the proximal femoral osteotomy performed for a variety of paediatric orthopaedic conditions


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 56 - 56
1 Jan 2016
Tamaki T Oinuma K Miura Y Higashi H Kaneyama R Shiratsuchi H
Full Access

Background. In total hip arthroplasty (THA), the importance of preserving muscle is widely recognized. It is important to preserve the short external rotator muscles because they contribute to joint stability and prevent postoperative dislocation. However, despite careful capsular release and femoral rasping, damage to the short external rotator muscles may occur. The Optymis Shot Stem preserves more bone and surrounding tissue than does a traditional primary stem. We investigated the usefulness of the stem in terms of the extent of preservation of the tendon attachment on the greater trochanter. Method. In this study, we enrolled 31 consecutive patients (39 hips; 6 males, 25 females) who underwent THA. Simultaneous bilateral THA was performed in 8 patients. The patients’ mean age was 56.1 years. Diagnoses included developmental dysplasia in 35 hips (Crowe group 1: 31 hips, group 2: 4 hips), and sequel of Perthes disease in 4 hips. All THAs were performed via the direct anterior approach without traction tables. The femoral procedure was performed with the hip hyperextended, and posterior capsular release was performed if the femoral procedure became technically difficult. We compared the following among patients: the operative time, intraoperative blood loss, length of hospital stay, rate of posterior capsular release, postoperative radiographic findings, WOMAC score before and after surgery, and any complications. Results. The mean operative time was 42.0 ± 8.9 min, the mean intraoperative blood loss was 308 ± 196 g, and the mean hospital stay was 6.7 ± 1.3 days. Posterior capsular release was performed in 17 hips [44%; 10 hips (32%) in Crowe group 1, 8 hips (88%) for other diagnoses]. The total WOMAC score improved significantly from 42.4 points preoperatively to 11.2 points at 3 months preoperatively. A postoperative stem subsidence ≥3 mm was observed in 1 hip (2.6%), whereas postoperative dislocation, intra- and postoperative periprosthetic fracture, and thigh pain were not observed. Conclusions. The Optymis Short Stem could be placed without performing posterior capsular release in 68% of patients with Crowe group 1 developmental dysplasia. We therefore consider the stem as useful for preserving the tendon attachment on the greater trochanter


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 23 - 23
1 Jun 2012
Cho YJ Kwak SJ Chun YS Rhyu KH Lee SM Yoo MC
Full Access

Purpose. To evaluate the clinical and radiologic midterm results of rotational acetabular osteotomy (RAO) in incongruent hip joints. Material and Methods. A consecutive series of 15 hips in 14 patients who underwent RAO in incongruent hip joint were evaluated at an average follow-up of 52.3 months (range from 36 to 101 months). The average age at operation was 27 years (range from 12 to 38 years) old. The preoperative diagnoses were developmental dysplasia in 4 hips, sequelae of Legg-Calvé-Perthes disease in 8 hips, and multiple epiphyseal dysplasia in 3 hips. The RAO procedures were combined with a femoral valgus oseotomy in 10 hips, advance osteotomy of greater trochanter in 4 hips, derotational osteotomy in 2 hips. Clinically, Harris hip score, range of motion, leg length discrepancy(LLD) and hip joint pain were evaluated. Radiological changes of anterior and lateral center-edge(CE) angle, acetabular roof angle, acetabular head index(AHI), ratio of body weight moment arm to abductor moment arm, and a progression of osteoarthritis were analyzed. Results. The Harris hip score ha been improved from average from 67.5 points preoperatively to 97.6 points postoperatively. There have been no significant changes in the range of motion. The anterior CE angle increased from an average of 9.0°(-19.7□18.6°) to 32.5°(22.6□39.1°), the lateral CE angle from 7.6°(-12.1□14.1)° to 31.7°(26.5□37.8°) and the AHI from 61%(33□73%) to 86%(65□100%). The average ratio of body weight moment arm to abductor moment arm was changed 1.88 to 1.49. There was no case showing progression of osteoarthritis. None of the patients experienced revision surgery. Conclusion. The conventional salvage operation, such as Chiari osteotomy, has been recommended in incongruent hip. However, if we can expect to have a congruency after RAO with/without any femoral osteotomies, it would be a hopeful procedure for the incongruent joints by enhancing acetabular coverage, taking joint surface with normal articular cartilage, increasing abductor moment arm with additional improvement in LLD


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 185 - 185
1 Sep 2012
Takao M Nishii T Sakai T Sugano N
Full Access

Introduction. Preoperative planning is an essential procedure for successful total hip arthroplasty. Many studies reported lower accuracy of two-dimensional analogue or digital templating for developmentally dysplastic hips (DDH). There have been few studies regarding the utility of three-dimensional (3D) templating for DDH. The aim of the present study is to assess the accuracy and reliability of 3D templating of cementless THA for hip dysplasia. Methods. We used 86 sets of 3D-CT data of 84 patients who underwent consecutive cementless THA using an anatomical stem and a rim-enlarged cup. There were six men and 78 women with the mean age of 58 years. The diagnosis was developmental dysplasia in 70 hips and osteonecrosis in 14 hips and primary osteoarthritis in 2 hips. There were 53 hips in Crowe group I, 11 hips in Crowe group II and 6 hips in Crowe group III. Each operator performed 3D templating prior surgery using a planning workstation of CT-based navigation system. Planned-versus-achieved accuracy was evaluated. The templating results were categorized as either exact size or +/− 1 size of implanted size. To assess the intra- and inter-planner reliabilities, 3D templating was performed by two authors blinded to surgery twice at an interval of one month. Kappa values were calculated. The accuracy and the intra- and inter-planner reliabilities were compared between the DDH group (70 hips) and the non DDH group (16 hips). Results. There was no significant difference in accuracy of component sizes between the DDH group and the non-DDH group. The accuracy of templating for cup sizes was 76 % for DDH and 75 % for non-DDH group (p=0.95). If accuracy was expanded to include all cups within one size of the implanted size, the accuracy was 97 % and 94 %, respectively (p=0.51). The accuracy of templating for stem sizes was 60 % for the DDH group and 75 % for the non-DDH group (p=0.27). The accuracy within 1 size was 99 % and 94 %, respectively (p=0.25). Regarding intra-planner reliability, mean kappa value for the cup size was 0.67 in the DDH group and 0.81 for the non-DDH group (p=0.18). Mean kappa value for the stem size was 0.64 in the DDH group and 0.79 for the non-DDH group (p=0.18). There were no significant differences in intra-planner reliability between the DDH and non-DDH group. Regarding inter-planner reliability for the cup size, mean kappa value was 0.33 in the DDH group and 0.37 in the non-DDH group (p=0.14). Mean kappa value for the stem size was 0.46 in the DDH group and 0.69 in the non-DDH group (p=0.07). There were no significant differences in inter-planner reliability between the DDH and non-DDH group. Conclusion. The 3D templating for cementless THA was accurate for hip dysplasia. Intra- and inter-planner reliabilities of the 3D templating were comparable with those of other primary diagnosis, while intra-planner reliability of cup sizes was fair regardless of diagnosis