Advertisement for orthosearch.org.uk
Results 1 - 20 of 123
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 10 - 10
1 Feb 2020
Clark A Hounat A MacLean A Jones B Blyth M
Full Access

We report on the 5 year results of a randomized study comparing TKR performed using conventional instrumentation versus electromagnetic computer-assisted surgery. This study analysed patient reported outcome measures (PROMs) at 5 years utilising the American Knee Society Score (AKSS), Oxford Knee Score (OKS), the Short Form 36 score and range of motion (ROM). Of the 200 patients enrolled 125 completed 5 year follow up, 62 in the navigated group and 63 in the conventional group. There were 28 deceased patients, 29 withdrawals and 16 lost to follow-up. There was improvement in clinical function in most PROMs from 1-5 year follow up across both groups. OKS improved from a mean of 26.6 (12–55) to 35.1 (5–48). AKSS increased from 75.3 (0–100) to 78.4 (−10–100), SF36 from 58.9 (2.5–100) to 53.2 (0–100). ROM improved by an average 7 degrees from 110 degrees to 117 degrees (80–135). There was no statistically significant difference in PROMs between the groups at 5 years. Patients undergoing revision surgery were identified from the dataset and global PACS. There were no revisions within 5 years in the navigated group and 3 revisions in the conventional group, two for infection and one for mid-flexion instability, giving an all cause revision rate of 3.06% at 5 years for this group. There appears to be no significant advantage in clinical function for patients undergoing TKR for OA of the knee with electromagnetic navigation when compared to conventional techniques. There may be an advantage in reducing early revision rates using this technology


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 44 - 44
1 Sep 2012
Blyth M Jones B Smith J Rowe P
Full Access

Electromagnetic navigation versus conventional Total Knee Arthroplasty: Clinical improvements Optical and electromagnetic (EM) tracking systems are widely used commercially. However in orthopaedic applications optical systems dominate the market. Optical systems suffer from deficiencies due to line of sight. EM trackers are smaller but are affected by metal. The accuracy of the two tracker systems has been seen to be comparable1. Recent advancements in optical navigated TKA have shown improved overall limb alignment, implant placement and reduce outliers when compared to conventional TKA2-4. This study is the first RCT to compare EM and conventional TKA. Two groups of 100 patients underwent TKA using either the EM navigation system or the conventional method. Frontal, sagittal and rotational alignment was analysed from a CT scan. Clinical scores including Oxford Knee Score (OKS) and Knee/Function American Knee Society Score (AKSS) were recorded pre-op, and at 3 and 12 months post-op. 3 month data presented includes 180 patients (n = 90). The 12 months data presented includes 140 (n = 70). The two groups had similar mean mechanical axis alignments (EM 0.31o valgus, conventional 0.15o valgus). The mechanical axis alignment was improved in the EM group with 92% within +/-3o of neutral compared to 84% of the conventional group (p = 0.90). The alignment of the EM group was improved in terms of frontal femoral, frontal tibial, sagittal femoral, sagittal tibial and tibial rotation alignment. However, only the sagittal femoral alignment was significantly improved in the EM group (p = 0.04). Clinically, both TKA groups showed significant improvements in OKS and AKSS scores between both pre-op to 3 month post-op and 3 months to 12 months post-op (p<0.001). The OKS and the AKSS knee score for the EM group was significantly better at 3 months post-op (OXS p = 0.02, AKSS knee p = 0.04). However there was no difference between the groups at 12 months. The mean pre-op range of motion (ROM) for both groups was 105o. This decreased to 102o in the EM group and 99o in the conventional group at 3 months. There was a significant improvement at 12 months post-op, EM = 113o (p = 0.012) and conventional = 112o (p = 0.026). There was no significant difference in ROM between the two groups at 3 or 12 months post-op. Therefore the alignment outcome of the EM TKA group was improved compared to the conventional group. The EM group also showed clinical improvements at 3 months post-op however these were not seen again at 12 months post-op. ROM was seen to decrease at 3 months post-op but then significantly improve by 12 month post-op


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 361 - 361
1 Sep 2012
Grimm B Tonino A Heyligers I
Full Access

Introduction. Large wear rate reductions have been shown for crosslinked PE in simulators and short- to mid-term clinical wear studies. However, concerns persist about long-term in-vivo oxidation (especially with annealed PE), late accelerating wear and the possibly higher osteolytic potential of crosslinked PE particle debris. This is the first long-term study comparing conventional to crosslinked PE investigating whether the wear reduction is maintained in the long-term and if reduced osteolysis becomes evident. Materials & Methods. In a prospective study 48 primary THA patients (Stryker ABG-II, 28mm CoCr heads) were randomized to either receive a first generation crosslinked PE (Stryker Duration: 3MRad gamma irradiation in N2, annealed) or then conventional, now “historic” PE (3MRad gamma irradiation in air). Both groups were statistically non-different (p>0.1) regarding age (63.9 years), gender, BMI, stem and cup size, cup inclination, liner thickness or pre- and post-op HHS leaving the insert material as the only variable. Patients were followed-up annually using the Harris Hip score, AP and lateral radiographs and digital wear measurements using Roman V1.70 [1, 2]. Wear and radiographic signs of osteolysis were analysed at a mean follow-up of 12.9 years (12.0–13.3). Groups were compared using the t-test (means) or the Fisher Exact test (proportions). Results. Thirty-one patients (18 conventional, 13 Duration) were left for analysis (8 deaths, 9 lost to FU). At 13yrs the total linear head penetration was sign. lower with Duration (0.70 ±0.36mm, range: 0.3–1.2mm) than conventional PE (1.56 ±0.83, range: 0.4–3.3mm, p=0.015). Also the annual wear rate was sign. lower (p=0.005) for Duration (0.063 ±0.027mm/yr) than conventional PE (0.122 ±0.065mm/yr). This reduction (−48%) compared well to the original simulator prediction (−45%) and even increased with time (−30% at 5yrs, −38% at 8yrs, −42% at 10yrs). In the Duration group only 1 patient had a wear rate >0.1mm/yr (osteolysis threshold) compared to 10 in the Conventional group (p=0.007). Patients with radiographic signs of acetabular osteolysis (cysts) on the AP x-ray were less frequent in the Duration (4/13=31%) than in conventional group (13/18=72%, p=0.023). This difference became even more pronounced when also the lateral view was evaluated and the affected DeLee-Charnley zones were counted (7 vs 22, p=0.017). Only in the conventional group a revision was performed (cup for wear). Discussion & Conclusions. At long-term FU the absolute wear rate of Duration crosslinked PE did not increase but decrease and the wear relative reduction did not deteriorate but increased. The incidence of osteolysis was sign. less. Thus No clinical evidence of degradation or elevated osteolytic potential for this annealed first generation crosslinked PE debris was found


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 912 - 917
1 Jul 2020
Tahir M Chaudhry EA Zimri FK Ahmed N Shaikh SA Khan S Choudry UK Aziz A Jamali AR

Aims

It has been generally accepted that open fractures require early skeletal stabilization and soft-tissue reconstruction. Traditionally, a standard gauze dressing was applied to open wounds. There has been a recent shift in this paradigm towards negative pressure wound therapy (NPWT). The aim of this study was to compare the clinical outcomes in patients with open tibial fractures receiving standard dressing versus NPWT.

Methods

This multicentre randomized controlled trial was approved by the ethical review board of a public sector tertiary care institute. Wounds were graded using Gustilo-Anderson (GA) classification, and patients with GA-II to III-C were included in the study. To be eligible, the patient had to present within 72 hours of the injury. The primary outcome of the study was patient-reported Disability Rating Index (DRI) at 12 months. Secondary outcomes included quality of life assessment using 12-Item Short-Form Health Survey questionnaire (SF-12), wound infection rates at six weeks and nonunion rates at 12 months. Logistic regression analysis and independent-samples t-test were applied for secondary outcomes. Analyses of primary and secondary outcomes were performed using SPSS v. 22.0.1 and p-values of < 0.05 were considered significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 19 - 22
1 Jan 2002
Kosygan KP Mohan R Newman RJ

We performed a randomised, prospective trial in 111 patients with intertrochanteric fractures of the hip comparing the use of the Gotfried percutaneous compression plate (PCCP) with that of the classic hip screw (CHS). Blood loss and transfusion requirement were less in the PCCP group but the operating time was significantly longer. The complication rate after operation was similar in both groups, and at a minimum follow-up of six months there was no difference in the rates of fracture healing or implant failure. The PCCP gives results which are similar to those obtained with a conventional device. Its suggested advantages seem to be theoretical rather than practical and, being a fixed-angle implant, it is not universally applicable


Bone & Joint Open
Vol. 5, Issue 2 | Pages 117 - 122
9 Feb 2024
Chaturvedi A Russell H Farrugia M Roger M Putti A Jenkins PJ Feltbower S

Aims. Occult (clinical) injuries represent 15% of all scaphoid fractures, posing significant challenges to the clinician. MRI has been suggested as the gold standard for diagnosis, but remains expensive, time-consuming, and is in high demand. Conventional management with immobilization and serial radiography typically results in multiple follow-up attendances to clinic, radiation exposure, and delays return to work. Suboptimal management can result in significant disability and, frequently, litigation. Methods. We present a service evaluation report following the introduction of a quality-improvement themed, streamlined, clinical scaphoid pathway. Patients are offered a removable wrist splint with verbal and written instructions to remove it two weeks following injury, for self-assessment. The persistence of pain is the patient’s guide to ‘opt-in’ and to self-refer for a follow-up appointment with a senior emergency physician. On confirmation of ongoing signs of clinical scaphoid injury, an urgent outpatient ‘fast’-wrist protocol MRI scan is ordered, with instructions to maintain wrist immobilization. Patients with positive scan results are referred for specialist orthopaedic assessment via a virtual fracture clinic. Results. From February 2018 to January 2019, there were 442 patients diagnosed as clinical scaphoid fractures. 122 patients (28%) self-referred back to the emergency department at two weeks. Following clinical review, 53 patients were discharged; MRI was booked for 69 patients (16%). Overall, six patients (< 2% of total; 10% of those scanned) had positive scans for a scaphoid fracture. There were no known missed fractures, long-term non-unions or malunions resulting from this pathway. Costs were saved by avoiding face-to-face clinical review and MRI scanning. Conclusion. A patient-focused opt-in approach is safe and effective to managing the suspected occult (clinical) scaphoid fracture. Cite this article: Bone Jt Open 2024;5(2):117–122


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_6 | Pages 4 - 4
20 Mar 2023
Reynolds A Kumar CS
Full Access

Midfoot arthrodesis is the conventional surgical intervention for midfoot arthritis. Arthrodesis aims to stabilise, realign and fuse the affected joints, providing patients with improved pain and function. Current research neglects the measurement of patient reported outcomes. This study aimed to investigate objective, and patient reported outcomes of midfoot arthrodesis. The secondary aim was to identify variables predicting the development of non-union. An automated search of online patient records identified 108 eligible patients (117 feet). The rates of union, re-operations, and complications were calculated using radiographs and medical records. Logistic regression was used to model variables influencing the odds of non-union. All living patients were posted a Manchester Oxford Foot Questionnaire (MOx-FQ), a patient reported outcome assessment. Pre-operative MOx-FQ results were available in a minority of cases. Students t-test was used to compare pre- and post-operative MOx-FQ scores. The rate of union achieved was 74%. The rate of re-operations was 35%. The rate of complications was 14%. Bone grafts and staple fixation independently impacted the odds of non-union. Bone grafts decreased the odds of non-union, whilst staple fixation increased the odds. This finding agrees with the opinion of other researchers. We recommend the use of bone grafts, and the avoidance of fixation with staples. Previous attempts have been made to assess patient outcomes. However, this study is the first to use the MOx-FQ, a validated questionnaire. Therefore, this study establishes a baseline for improvements in patient reported outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 6 - 6
13 Mar 2023
Pawloy K Sargeant H Smith K Rankin I Talukdar P Hancock S Munro C
Full Access

Our unit historically performed total hip replacement (THR) through either posterior or anterolateral approaches. In November 2020 a group of 5 consultants transitioned to utilising the Direct Anterior Approach (DAA). Appropriate training was undertaken and cases were performed as dual consultant procedures with intraoperative radiography or robotic assistance. Outcomes were collated prospectively. These included basic demographics, intraoperative details, complication rates and Oxford Hip Scores. A total of 48 patients underwent DAA THR over 1 year. Mean age was 67 and ASA 2. Over this time period 140 posterior approach and 137 anterolateral approach THR's were performed with available data. Propensity score matching was performed on a 1:1 basis using BMI, Age, Sex and ASA as covariates to generate a matched cohort group of conventional approach THR (n=37). Length of stay was significantly reduced at 1.95 days (p<0.001) with DAA compared to Anterolateral and Posterior approach. There was no significant difference with length of surgery, blood loss, Infection, dislocation and periprosthetic fracture rate. There was no significant difference in Oxford Hip Score between any approach at 3 months or 1 year. The transition to this approach has not made a negative impact despite its associated steep learning curve, and has improved efficiency in elective surgery. From our experience we would suggest those changing to this approach receive appropriate training in a high-volume centre, and perform cases as dual consultant procedures


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 134 - 141
1 Jan 2022
Cnudde PHJ Nåtman J Hailer NP Rogmark C

Aims. The aim of this study was to investigate the potentially increased risk of dislocation in patients with neurological disease who sustain a femoral neck fracture, as it is unclear whether they should undergo total hip arthroplasty (THA) or hemiarthroplasty (HA). A secondary aim was to investgate whether dual-mobility components confer a reduced risk of dislocation in these patients. Methods. We undertook a longitudinal cohort study linking the Swedish Hip Arthroplasty Register with the National Patient Register, including patients with a neurological disease presenting with a femoral neck fracture and treated with HA, a conventional THA (cTHA) with femoral head size of ≤ 32 mm, or a dual-mobility component THA (DMC-THA) between 2005 and 2014. The dislocation rate at one- and three-year revision, reoperation, and mortality rates were recorded. Cox multivariate regression models were fitted to calculate adjusted hazard ratios (HRs). Results. A total of 9,638 patients with a neurological disease who also underwent unilateral arthroplasty for a femoral neck fracture were included in the study. The one-year dislocation rate was 3.7% after HA, 8.8% after cTHA < 32 mm), 5.9% after cTHA (= 32 mm), and 2.7% after DMC-THA. A higher risk of dislocation was associated with cTHA (< 32 mm) compared with HA (HR 1.90 (95% confidence interval (CI) 1.26 to 2.86); p = 0.002). There was no difference in the risk of dislocation with DMC-THA (HR 0.68 (95% CI 0.26 to 1.84); p = 0.451) or cTHA (= 32 mm) (HR 1.54 (95% CI 0.94 to 2.51); p = 0.083). There were no differences in the rate of reoperation and revision-free survival between the different types of prosthesis and sizes of femoral head. Conclusion. Patients with a neurological disease who sustain a femoral neck fracture have similar rates of dislocation after undergoing HA or DMC-THA. Most patients with a neurological disease are not eligible for THA and should thus undergo HA, whereas those eligible for THA could benefit from a DMC-THA. Cite this article: Bone Joint J 2022;104-B(1):134–141


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 746 - 754
1 Apr 2021
Schnetzke M El Barbari J Schüler S Swartman B Keil H Vetter S Gruetzner PA Franke J

Aims. Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation. Methods. A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days). Results. The mean length of time until operability was 8.2 days (SD 3.0) in the intervention group and 10.2 days (SD 3.7) in the control group across all three fractures groups combined (p = 0.004). An analysis of the subgroups revealed that a significant reduction in the time to operability was achieved in two of the three: with 8.6 days (SD 2.2) versus 10.6 days (SD 3.6) in ankle fractures (p = 0.043), 9.8 days (SD 4.1) versus 12.5 days (SD 5.1) in pilon fractures (p = 0.205), and 7.0 days (SD 2.6) versus 8.4 days (SD 1.5) in calcaneal fractures (p = 0.043). A lower length of stay (p = 0.007), a reduction in pain (p. preop. = 0.05; p. discharge. < 0.001) and need for narcotics (p. preop. = 0.064; p. postop. = 0.072), an increased reduction in swelling (p < 0.001), and a lower revision rate (p = 0.044) could also be seen, and a trend towards fewer complications (p = 0.216) became apparent. Conclusion. Compared with elevation, VIT results in a significant reduction in the time to achieve operability in complex joint fractures of the lower limb. Cite this article: Bone Joint J 2021;103-B(4):746–754


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims

Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone.

Methods

Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 218 - 226
15 Mar 2024
Voigt JD Potter BK Souza J Forsberg J Melton D Hsu JR Wilke B

Aims

Prior cost-effectiveness analyses on osseointegrated prosthesis for transfemoral unilateral amputees have analyzed outcomes in non-USA countries using generic quality of life instruments, which may not be appropriate when evaluating disease-specific quality of life. These prior analyses have also focused only on patients who had failed a socket-based prosthesis. The aim of the current study is to use a disease-specific quality of life instrument, which can more accurately reflect a patient’s quality of life with this condition in order to evaluate cost-effectiveness, examining both treatment-naïve and socket refractory patients.

Methods

Lifetime Markov models were developed evaluating active healthy middle-aged male amputees. Costs of the prostheses, associated complications, use/non-use, and annual costs of arthroplasty parts and service for both a socket and osseointegrated (OPRA) prosthesis were included. Effectiveness was evaluated using the questionnaire for persons with a transfemoral amputation (Q-TFA) until death. All costs and Q-TFA were discounted at 3% annually. Sensitivity analyses on those cost variables which affected a change in treatment (OPRA to socket, or socket to OPRA) were evaluated to determine threshold values. Incremental cost-effectiveness ratios (ICERs) were calculated.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 688 - 695
1 Jun 2023
Johnston GHF Mastel M Sims LA Cheng Y

Aims

The aims of this study were to identify means to quantify coronal plane displacement associated with distal radius fractures (DRFs), and to understand their relationship to radial inclination (RI).

Methods

From posteroanterior digital radiographs of healed DRFs in 398 female patients aged 70 years or older, and 32 unfractured control wrists, the relationships of RI, quantifiably, to four linear measurements made perpendicular to reference distal radial shaft (DRS) and ulnar shaft (DUS) axes were analyzed: 1) DRS to radial aspect of ulnar head (DRS-U); 2) DUS to volar-ulnar corner of distal radius (DUS-R); 3) DRS to proximal capitate (DRS-PC); and 4) DRS to DUS (interaxis distance, IAD); and, qualitatively, to the distal ulnar fracture, and its intersection with the DUS axis.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims

The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs.

Methods

The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 57 - 57
1 Sep 2012
Cartner J Hartsell Z Cooper P Ricci W Tornetta III P
Full Access

Introduction. Conventional screws achieve sufficient insertion torque in healthy bone. In poor bone screw stripping can occur prior to sufficient torque generation. It was hypothesized that a screw with a larger major/minor diameter ratio would provide improved purchase in poor bone as compared to conventional screws. We evaluated the mechanical characteristics of such a screw using multiple poor bone quality models. Methods. Testing groups included: conventional screws, osteopenia screws used in bail-out manner (ie, larger major/minor diameter screws inserted into a hole stripped by a conventional screw), and osteopenia screws used in a preemptive manner (ie, no screw stripping occurrence). Stripping Torque: Screws were inserted through standard straight plates into a low density block of foam with a predrilled hole. Stripping torque was defined as maximum insertion torque reached by the screw before the screw began to spin freely in the foam. Pullout. Pullout tests were conducted on screws inserted into the same test media. Axial pull-out testing was then conducted by applying a tensile load to the screws. Compression. Screws were inserted through standard straight plates by hand while the amount of compression achieved between plate and bone was measured using a pressure sensor. The same foam test media was utilized in addition to osteoporotic fresh-frozen femoral diaphyseal cadaver (bone mineral density<0.60 g/cm2). The screws were tightened across a range of possible insertion torques with pressure measurements taken at multiple intervals. Results. The osteopenia bone screws showed a 67% increase in torque before stripping occurred (p<0.01) when compared to the conventional screw. The osteopenia screw used in a bail-out manner showed a 57% increase in stripping torque (p<0.01) and a 76% increase in pullout strength (p<0.01) when compared to the conventional screw. Additionally, the bail-out screw showed a minimal decrease in both stripping torque (6%, p = 0.45) and pullout strength (11%, p<0.01) when compared to the osteopenia screw tested in preemptive manner. There was a linear relationship between applied torque and compressive force generation for both osteopenia and conventional screws. The osteopenia screws were able to gain greater compression against bone across a range of insertion values as compared to conventional bone screws. Discussion. The osteopenia screw achieved superior stripping torque, pullout strength, and compressive forces when compared to conventional screws in simulated poor quality bone and osteoporotic cadaver bone. When used as a bail-out screw, it also achieved superior stripping torque and pullout strength. The results of this study indicate that a screw of larger major/minor diameter ratio could be an effective bail-out option for screw stripping associated with osteopenic fracture fixation


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 11 - 11
1 Feb 2020
Johnston WD Razii N Banger MS Rowe PJ Jones BG MacLean AD Blyth MJG
Full Access

The objective of this study was to compare differences in alignment following robotic arm-assisted bi-unicompartmental knee arthroplasty (Bi-UKA) and conventional total knee arthroplasty (TKA). This was a prospective, randomised controlled trial of 70 patients. 39 TKAs were implanted manually, as per standard protocol at our institution, and 31 Bi-UKA patients simultaneously received fixed-bearing medial and lateral UKAs, implanted using robotic arm-assistance. Preoperative and 3-month postoperative CT scans were analysed to determine hip knee ankle angle (HKAA), medial distal femoral angle (MDFA), and medial proximal tibial angle (MPTA). Analysis was repeated for 10 patients by a second rater to validate measurement reliability by calculating the intra-class correlation coefficient (ICC). Mean change in HKAA towards neutral was 2.7° in TKA patients and 2.3° in Bi-UKA patients (P=0.6). Mean change in MDFA was 2.5° for TKA and 1.0° for Bi-UKA (P<0.01). Mean change in MPTA was 3.7° for TKA and 0.8° for Bi-UKA (P<0.01). Mean postoperative MDFA and MPTA for TKAs were 89.8° and 89.6° respectively, indicating orientation of femoral and tibial components perpendicular to the mechanical axis. Mean postoperative MDFA and MPTA for Bi-UKAs were 91.0° and 86.9° respectively, indicating a more oblique joint line orientation. Inter-rater agreement was excellent (ICC>0.99). Early functional activities, according to the new Knee Society Scoring System, favoured Bi-UKAs (P<0.05). Robotic arm-assisted, cruciate-sparing Bi-UKA better maintains the natural anatomy of the knee in the coronal plane and may therefore preserve normal joint kinematics, compared to a mechanically aligned TKA. This has been achieved without significantly altering overall HKAA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 544 - 544
1 Sep 2012
Hoppe S Frauchiger L Mainzer J Ballmer P Hess R Zumstein M
Full Access

Background. Navigation in total knee replacement is controversially discussed in the literature. In our previous study, femoral component positioning was more accurate with computed navigation than with conventional implantation techniques, however tibial positioning showed similar results. Moreover there were no differences between image-free and image-based navigation techniques. To what extent more accurate femoral positioning has an impact on the clinical mid-term follow up is not known. Methods. At a mean follow-up interval of 5.3 years, seventy-one patients (84.5%) returned for a review and were examined clinically and radiographically, with use of a methodology identical to that used preop and at 2 years, using the subjective value, the Knee Society Score (KSS), and a.p. and true lateral standard radiographs respectively. Complications, re-operations, persisting pain and resulting range of motion were registered. Results. Four patients in the image-based (2x late-onset infection, 1x femoral impingement, 1x component malalignment), 2 in the conventional group (2x component malalignment) and 1 patient in the image-free navigated group (arthoscopic debridement for arthrofibrosis) needed reoperation in the mean time. 59 of the 71 patients were very satisfied and satisfied at 5.3 years folllow up: (conventional: 19 of 25 (77±8 years); image-based navigation: 18 of 22 (77±10 years); image-free navigation: 22 of 24 (78±7 years)). The mean average of the Knee Society Score was 92.3(range 47 to 98). Compared to the conventional (KSS: 93.9±8,0) and image-free (KSS: 94.0±6,43) group, the KSS in the image-based group was insignificantly lower (KSS: 90±13,6) (p< 0,05). Radiographically, two patients in the conventional group showed a lysis on the lateral and medial tibia plateau of <1 mm without any clinical significance. There was no need for reintervention. There were no significant differences concerning remainig pain (conventional: 24%; image-based 18%; image-free: 8,5%), ROM and ligamental stability. Conclusion. Radiographical and clinical mid-term results after TKA yielded good and excellent results independent of the computed navigation and its type. Even a more accurate femoral component positioning in the patients cohort has been shown, we couldn't find a significant difference concerning the clinical outcome 5.3 years after conventional, image-based and image-free total knee arthroplasty. Despite of increased costs and time for navigated techniques we cannot show a mid-term benefit in functional and subjectiv outcome compared to conventional techniques


Bone & Joint Open
Vol. 3, Issue 3 | Pages 189 - 195
4 Mar 2022
Atwan Y Sprague S Slobogean GP Bzovsky S Jeray KJ Petrisor B Bhandari M Schemitsch E

Aims

To evaluate the impact of negative pressure wound therapy (NPWT) on the odds of having deep infections and health-related quality of life (HRQoL) following open fractures.

Methods

Patients from the Fluid Lavage in Open Fracture Wounds (FLOW) trial with Gustilo-Anderson grade II or III open fractures within the lower limb were included in this secondary analysis. Using mixed effects logistic regression, we assessed the impact of NPWT on deep wound infection requiring surgical intervention within 12 months post-injury. Using multilevel model analyses, we evaluated the impact of NPWT on the Physical Component Summary (PCS) of the 12-Item Short-Form Health Survey (SF-12) at 12 months post-injury.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 55 - 55
1 Apr 2013
Kawakami Y Hiranaka T Niikura T Matsuzaki T Hida Y Uemoto H Doita M Tsuji M Kurosaka M
Full Access

Introduction. Plate fixations have been recommended for dislocated clavicle fractures. However, existing plates are inadequate for morphological compatibility with the clavicle. The aim of this study is to measure the anatomical shape of the clavicle and to compare the radiographical and clinical outcomes of our tree-dimensional (3D) reconstruction plate with conventional straight plate. Methods. Chest CT image of 15 patients with normal clavicle were analyzed. Their clavicles were reconstructed and measured their anatomical variables. A hospital-based case-control study was conducted, including a consecutive series of 52 patients with displaced midshaft clavicle fractures. 3D reconstruction plate was used for 26 patients and another 26 patients were treated with conventional straight plate. Outcome measures included the period of bone union, revision surgery, operating times and clinical symptoms using DASH score. Results. The result indicated that plates applying to any shape of the clavicle require a strong curve on the distal part and a twist on the proximal part. A case-control study demonstrated that the conventional straight plate group had higher rate of delayed union and had more symptomatic than the 3D group. Conclusion. The plates with a strong curve on the distal end and a twist on the proximal end exhibit better compatibility with the clavicle. Our 3D reconstruction plate showed superiority in both radiographical and clinical outcome than conventional straight ones