Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Bone & Joint Open
Vol. 3, Issue 8 | Pages 648 - 655
1 Aug 2022
Yeung CM Bhashyam AR Groot OQ Merchan N Newman ET Raskin KA Lozano-Calderón SA

Aims

Due to their radiolucency and favourable mechanical properties, carbon fibre nails may be a preferable alternative to titanium nails for oncology patients. We aim to compare the surgical characteristics and short-term results of patients who underwent intramedullary fixation with either a titanium or carbon fibre nail for pathological long-bone fracture.

Methods

This single tertiary-institutional, retrospectively matched case-control study included 72 patients who underwent prophylactic or therapeutic fixation for pathological fracture of the humerus, femur, or tibia with either a titanium (control group, n = 36) or carbon fibre (case group, n = 36) intramedullary nail between 2016 to 2020. Patients were excluded if intramedullary fixation was combined with any other surgical procedure/fixation method. Outcomes included operating time, blood loss, fluoroscopic time, and complications. Fisher’s exact test and Mann-Whitney U test were used for categorical and continuous outcomes, respectively.


Aims

The use of frozen tumour-bearing autograft combined with a vascularized fibular graft (VFG) represents a new technique for biological reconstruction of massive bone defect. We have compared the clinical outcomes between this technique and Capanna reconstruction.

Methods

From June 2011 to January 2016 a retrospective study was carried out of patients with primary osteosarcoma of lower limbs who underwent combined biological intercalary reconstruction. Patients were categorized into two groups based on the reconstructive technique: frozen tumour-bearing autograft combined with concurrent VFG (Group 1) and the Capanna method (Group 2). Demographics, operating procedures, oncological outcomes, graft union, limb function, and postoperative complications were compared.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 177 - 185
1 Feb 2020
Lim CY Liu X He F Liang H Yang Y Ji T Yang R Guo W

Aims

To investigate the benefits of denosumab in combination with nerve-sparing surgery for treatment of sacral giant cell tumours (GCTs).

Methods

This is a retrospective cohort study of patients with GCT who presented between January 2011 and July 2017. Intralesional curettage was performed and patients treated from 2015 to 2017 also received denosumab therapy. The patients were divided into three groups: Cohort 1: control group (n = 36); cohort 2: adjuvant denosumab group (n = 9); and cohort 3: neo- and adjuvant-denosumab group (n = 17).


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 667 - 674
1 May 2018
Lauthe O Soubeyrand M Babinet A Dumaine V Anract P Biau DJ

Aims

The primary aim of this study was to determine the morbidity of a tibial strut autograft and characterize the rate of bony union following its use.

Patients and Methods

We retrospectively assessed a series of 104 patients from a single centre who were treated with a tibial strut autograft of > 5 cm in length. A total of 30 had a segmental reconstruction with continuity of bone, 27 had a segmental reconstruction without continuity of bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity was defined as any event that required a modification of the postoperative management. Union was assessed clinically and radiologically at a median of 36 months (IQR, 14 to 74).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 814 - 816
1 Jun 2007
Nawabi DH Sinisi M

Schwannomas are the most common tumours of the sheath of peripheral nerves. The clinical diagnosis is usually straightforward, but may be delayed for many years in a schwannoma of the posterior tibial nerve. The symptoms are often attributed to entrapment neuropathy or to lumbosacral radiculopathy.

We describe 25 patients with a schwannoma of the posterior tibial nerve. Only three were diagnosed within a year of presentation. The mean time to diagnosis was 86.5 months with a median of 48 months (2 to 360). All the patients complained of pain, which was felt specifically in the sole of the foot in 18. A Tinel sign was detected in all 25 patients. MRI confirmed the diagnosis in all the cases in which it had been undertaken. Surgical resection of the lesion abolished the neuropathic pain. In patients with a long history of neuropathic pain in the lower limb in whom lumbar and pelvic lesions have been excluded, a benign tumour of the sheath of a peripheral nerve may explain the symptoms. Surgical resection of the tumour is safe and effective.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 786 - 794
1 Jun 2008
Aksnes LH Bauer HCF Jebsen NL Foller̊s G Allert C Haugen GS Hall KS

We evaluated the long-term functional outcome in 118 patients treated for osteosarcoma or Ewing’s sarcoma in the extremities a minimum of five years after treatment. We also examined if impaired function influenced their quality of life and ability to work.

The function was evaluated according to the Musculoskeletal Tumor Society (MSTS) score and the Toronto Extremity Salvage Score (TESS). Quality of life was assessed by using the Short Form-36 (SF-36).

The mean age at follow-up was 31 years (15 to 57) and the mean follow-up was for 13 years (6 to 22). A total of 67 patients (57%) initially had limb-sparing surgery, but four had a secondary amputation. The median MSTS score was 70% (17% to 100%) and the median TESS was 89% (43% to 100%). The amputees had a significantly lower MSTS score than those with limb-sparing surgery (p < 0.001), but there was no difference for the TESS. Tumour localisation above knee level resulted in significantly lower MSTS scores and TESS (p = 0.003 and p = 0.02, respectively).

There were no significant differences in quality of life between amputees and those with limb-sparing surgery except in physical functioning. Of the patients 11% (13) did not work or study. In multivariate analysis, amputation, tumour location above the knee and having muscular pain were associated with low physical function.

We conclude that most of the bone tumour survivors managed well after adjustment to their physical limitations. A total of 105 are able to work and have an overall good quality of life.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1111 - 1117
1 Aug 2011
Sewell MD Hanna SA McGrath A Aston WJS Blunn GW Pollock RC Skinner JA Cannon SR Briggs TWR

The best method of reconstruction after resection of malignant tumours of the tibial diaphysis is unknown. In the absence of any long-term studies analysing the results of intercalary endoprosthetic replacement, we present a retrospective review of 18 patients who underwent limb salvage using a tibial diaphyseal endoprosthetic replacement following excision of a malignant bone tumour. There were ten men and eight women with a mean age of 42.5 years (16 to 76). Mean follow-up was 58.5 months (20 to 141) for all patients and 69.3 months (20 to 141) for the 12 patients still alive. Cumulative patient survival was 59% (95% confidence interval (CI) 32 to 84) at five years. Implant survival was 63% (95% CI 35 to 90) at ten years. Four patients required revision to a proximal tibial replacement at a mean follow-up of 29 months (10 to 54). Complications included metastases in five patients, aseptic loosening in four, peri-prosthetic fracture in two, infection in one and local recurrence in one. The mean Musculoskeletal Tumor Society score and the mean Toronto Extremity Salvage Score were 23 (17 to 28) and 74% (53 to 91), respectively.

Although rates of complication and revision were high, custom-made tibial diaphyseal replacement following resection of malignant bone tumours enables early return to function and provides an attractive alternative to other surgical options, without apparent compromise of patient survival.