We report the ten-year survival of a cemented
total knee replacement (TKR) in patients aged <
55 years at the
time of surgery, and compare the functional outcome with that of
patients aged >
55 years. The data were collected prospectively
and analysed using Kaplan-Meier survival statistics, with revision
for any reason, or death, as the endpoint. A total of 203 patients
aged <
55 years were identified. Four had moved out of the area
and were excluded, leaving a total of 221 TKRs in 199 patients for
analysis (101 men and 98 women, mean age 50.6 years (28 to 55));
171 patients had osteoarthritis and 28 had inflammatory arthritis.
Four patients required revision and four died. The ten-year survival
using revision as the endpoint was 98.2% (95% confidence interval
94.6 to 99.4). Based on the Oxford knee scores at five and ten years,
the rate of dissatisfaction was 18% and 21%, respectively. This
was no worse in the patients aged <
55 years than in patients
aged >
55 years. These results demonstrate that the cemented PFC Sigma knee has
an excellent survival rate in patients aged <
55 ten years post-operatively,
with clinical outcomes similar to those of an older group. We conclude
that TKR should not be withheld from patients on the basis of age.
Abstract. Introduction. Secondary osteonecrosis of the knee affects young population and causes bilateral extensive lesions. Arthroplasty is the last resort in younger population and joint preserving options questionable in pathological bone. Conservative measures have shown failure in multiple studies and hence no gold standard treatment advocated. We aimed at identifying and analysing various treatment options for secondary osteonecrosis with respect to the outcomes and studying features of symptomatic secondary osteonecrosis with regards to demographic pattern, radiological features and causative factors. Methods. A systematic review of literature was performed in accordance with the Cochrane handbook for systematic reviews and reported according to the PRISMA guidelines. Results. Six studies which included a total of 192 patients with data on 240 knee joints were included in the final review. Follow up period ranged from 1 year to 16 years. The mean age of the patients was 34.7. 3 studies were on arthroplasty and 3 on joint preserving interventions. Majority of patients were in Stage 2 or Stage 4 of osteonecrosis. Steroid induced osteonecrosis was the majority followed by SLE and sickle cell disease. The pooled analysis showed an improvement of pre-operative knee score from 50.47 to 89.21 post-operatively. The pooled effect size for failure rate was 8.7% in joint preserving interventions and 9.2% in joint replacement group. Conclusion. Joint preserving techniques with bone marrow aspirate infiltration showed promising functional outcome and to a certain extent reversal of the pathological process. For advanced stages with subchondral collapse
Abstract. Introduction. COMPOSE describes the demographics, fracture characteristics, management and associated outcomes of knee femoral periprosthetic fractures (KFPPF). Methods. Multicentre retrospective cohort study conducted 01/01/2018-31/12/2018. Data collected included: patient demographics, social and mobility characteristics, fracture characteristics, management strategy and post-treatment outcomes (length of stay, reoperation, readmission, 30-day and 12-month mortality). Results. 785 PPFs from 27 NHS sites were included in the COMPOSE cohort. Of these 162 (21%) were related to an isolated knee prosthesis (151 femur, 10 tibia and 1 patella). The KFPPF group had a mean age of 81.1 years, 127 (84%) female, 114 (76%) living in their own home, with 99 (63%) reliant on walking aids/bedbound. Most fractures were B (58%) or C (35%) type and occurred around a primary
We describe the survivorship of the Medial Rotation total knee replacement (TKR) at ten years in 228
This prospective study compares the outcome of
157 hydroxyapatite (HA)-coated tibial components with 164 cemented
components in the ROCC Rotating Platform total knee replacement
in 291 patients. The mean follow-up was 7.6 years (5.2 to 11). There
were two revisions for loosening: one for an HA-coated and one for
a cemented tibial component. Radiological evaluation demonstrated
no radiolucent lines with the HA-coated femoral components. A total
of three HA-coated tibial components exhibited radiolucent lines
at three months post-operatively and these disappeared after three
further months of protected weight-bearing. With HA-coated components
the operating time was shorter (p <
0.006) and the radiological
assessment of the tibial interface was more stable (p <
0.01).
Using revision for aseptic loosening of the tibial component as
the end point, the survival rates at nine years was identical for
both groups at 99.1%. Our results suggest that HA-coated components perform at least
as well as the same design with cemented components and compare
favourably with those of series describing
We evaluated the rates of survival and cause
of revision of seven different brands of
We have evaluated prospectively the incidence and location of deep-vein thrombosis (DVT), the risk factors for pulmonary embolism, and the natural history of thrombosis after total knee replacement (TKR) in patients who did not receive prophylactic or therapeutic treatment for DVT. We studied 227 patients who underwent primary TKR; 116 had one-stage bilateral and 111 unilateral procedures. Coagulation assays, the full blood count and blood typing tests for the serum chemical profile were undertaken in all patients on three separate occasions. Bilateral simultaneous or unilateral venograms were carried out at six or seven days after operation. Perfusion lung scanning was undertaken before and at seven or eight days after operation. Bilateral simultaneous or unilateral venograms were repeated six months after operation in all patients who had thrombi. In the 116 patients with a bilateral replacement, 97 of 232 venograms (41.8%) were positive for fresh thrombi while there were 46 positive venograms (41.4%) in the 111 patients with a unilateral replacement (p = 1.000). Of the 116 venograms in knees with a
We analysed at a mean follow-up of 7.25 years the clinical and radiological outcome of 117 patients (125 knees) who had undergone a primary, cemented, modular Freeman-Samuelson total knee replacement. While the tibial and femoral components were cemented, the patellar component was uncemented. A surface-cementing technique was used to secure the tibial components. A total of 82 knees was available for radiological assessment. Radiolucent lines were seen in 41 knees (50%) and osteolytic lesions were seen in 13 knees (16%). Asymptomatic, rotational loosening of the patellar implant was seen in four patients and osteolysis was more common in patients with a patellar resurfacing. Functional outcome scores were available for 41 patients (41 knees, 35%) and the mean Western Ontario McMasters Universities score was 77.5 (
Systemic emboli released during total knee replacement have been implicated as a cause of peri-operative morbidity and neurological dysfunction. We undertook a prospective, double-blind, randomised study to compare the cardiac embolic load sustained during computer-assisted and conventional, intramedullary-aligned, total knee replacement, as measured by transoesophageal echocardiography. There were 26 consecutive procedures performed by a single surgeon at a single hospital. The embolic load was scored using the modified Mayo grading system for echogenic emboli. Fourteen patients undergoing computer-assisted total knee replacement had a mean embolic score of 4.89 (3 to 7) and 12 undergoing conventional total knee replacement had a mean embolic score of 6.15 (4 to 8) on release of the tourniquet. Comparison of the groups using a two-tailed This study demonstrates that computer-assisted knee replacement results in the release of significantly fewer systemic emboli than the conventional procedure using intramedullary alignment.