Advertisement for orthosearch.org.uk
Results 1 - 20 of 32
Results per page:
Bone & Joint Research
Vol. 5, Issue 9 | Pages 419 - 426
1 Sep 2016
Leichtle CI Lorenz A Rothstock S Happel J Walter F Shiozawa T Leichtle UG

Objectives. Cement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of different screw types and amount of cement applied. Therefore, the aim of this biomechanical in vitro study was to evaluate the effect of cement augmentation on the screw pull-out force in osteoporotic vertebrae, comparing different pedicle screws (solid and fenestrated) and cement volumes (0 mL, 1 mL or 3 mL). Materials and Methods. A total of 54 osteoporotic human cadaver thoracic and lumbar vertebrae were instrumented with pedicle screws (uncemented, solid cemented or fenestrated cemented) and augmented with high-viscosity PMMA cement (0 mL, 1 mL or 3 mL). The insertion torque and bone mineral density were determined. Radiographs and CT scans were undertaken to evaluate cement distribution and cement leakage. Pull-out testing was performed with a material testing machine to measure failure load and stiffness. The paired t-test was used to compare the two screws within each vertebra. Results. Mean failure load was significantly greater for fenestrated cemented screws (+622 N; p ⩽ 0.001) and solid cemented screws (+460 N; p ⩽ 0.001) than for uncemented screws. There was no significant difference between the solid and fenestrated cemented screws (p = 0.5). In the lower thoracic vertebrae, 1 mL cement was enough to significantly increase failure load, while 3 mL led to further significant improvement in the upper thoracic, lower thoracic and lumbar regions. Conclusion. Conventional, solid pedicle screws augmented with high-viscosity cement provided comparable screw stability in pull-out testing to that of sophisticated and more expensive fenestrated screws. In terms of cement volume, we recommend the use of at least 1 mL in the thoracic and 3 mL in the lumbar spine. Cite this article: C. I. Leichtle, A. Lorenz, S. Rothstock, J. Happel, F. Walter, T. Shiozawa, U. G. Leichtle. Pull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae. Bone Joint Res 2016;5:419–426


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 127 - 127
1 Apr 2012
Luo J Gibson J Robson-Brown K Annesley-Williams D Adams M Dolan P
Full Access

To investigate whether restoration of mechanical function and spinal load-sharing following vertebroplasty depends upon cement distribution. Fifteen pairs of cadaver motion segments (51-91 yr) were loaded to induce fracture. One from each pair underwent vertebroplasty with PMMA, the other with a resin (Cortoss). Various mechanical parameters were measured before and after vertebroplasty. Micro-CT was used to determine volumetric cement fill, and plane radiographs (sagittal, frontal, and axial) to determine areal fill, for the whole vertebral body and for several specific regions. Correlations between volumetric fill and areal fill for the whole vertebral body, and between regional volumetric fill and changes in mechanical parameters following vertebroplasty, were assessed using linear regression. For Cortoss, areal and volumetric fills were significantly correlated (R=0.58-0.84) but cement distribution had no significant effect on any mechanical parameters following vertebroplasty. For PMMA, areal fills showed no correlation with volumetric fill, suggesting a non-uniform distribution of cement that influenced mechanical outcome. Increased filling of the vertebral body adjacent to the disc was associated with increased intradiscal pressure (R=0.56, p<0.05) in flexed posture, and reduced neural arch load bearing (F. N. ) in extended posture (R=0.76, p<0.01). Increased filling of the anterior vertebral body was associated with increased bending stiffness (R=0.55, p<0.05). Cortoss tends to spread evenly within the vertebral body, and its distribution has little influence on the mechanical outcome of vertebroplasty. PMMA spreads less evenly, and its mechanical benefits are increased when cement is concentrated in the anterior vertebral body and adjacent to the intervertebral disc


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 23 - 23
1 Jun 2012
Sidaginamale RP Gunaratne M Fadero P Kotrba M
Full Access

Purpose. To evaluate the complications following percutaneous balloon kyphoplasty and assess the advantage of introducing eggshell technique. Methods and Results. We performed 138 Balloon kyphoplasty procedures in 85 patients during august 2007 to march 2010. Data was collected and analyzed in all these cases. Gender distribution was 60 females and 25 males. Age distribution was 33 to 85 years, with an average age of 67.4 years. Indications of surgery were vertebral fractures due to osteoporosis in 81% of the procedures, trauma in 13% and malignancy in 6%. The most common vertebral levels of the kyphoplasty were at T12 in 32 procedures (23%) and L1 in 28 procedures (20%). Eggshell technique was introduced in 2009 where technical problems were encountered during cementing process. All patients had reduced pain levels, which was assessed by visual analog score. The average length of hospital stay was 2.5 days. Complications were 9 (6.5%) cement leaks (all within one cm from the vertebral body) in procedures performed before the introduction of eggshell technique and no cement leak following the introduction of eggshell technique, 5 (3.6%) fresh fractures, 2 (1.4%) intra-operative fractures and 1 (0.73%) rupture of balloon. There were no complications of cord compression, motor deficit, infection, allergy to cement or pulmonary embolism noted. 30-day mortality rate was zero. Conclusion. Our series had 6.5% incidence of cement leak compared to 11-21% quoted in current literature. Since the introduction of eggshell technique, cement leak rate was reduced to zero%. Hence adopting of eggshell technique during percutaneous balloon kyphoplasty procedure may eliminates the risk of cement leak thereby minimizing complications


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 83 - 89
1 Jan 2003
Yeom JS Kim WJ Choy WS Lee CK Chang BS Kang JW

We analysed the CT scans and radiographs of 76 vertebrae in 49 patients who underwent vertebroplasty for painful osteoporotic compression fractures. Leaks of cement were classified into three types: those via the basivertebral vein (type B), via the segmental vein (type S), and through a cortical defect (type C). More leaks were identified on CT scans than on radiographs by a factor of 1.5 (74/49). Most type-B (93%) and type-S (86%) leaks were missed or underestimated on a lateral radiograph which is usually the only view used during the injection of cement. Of the leaks into the spinal canal, only 7% (2/28) were correctly identified on radiographs. The areas on lateral radiographs where this type of leak may be observed were divided into four zones, and their diagnostic value in predicting a leak into the spinal canal was evaluated. The results showed that cement in the neural foramina had the highest positive predictive value (86%)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 11 - 11
7 Aug 2024
Warren JP Khan A Mengoni M
Full Access

Objectives. Understanding lumbar facet joint involvement and biomechanical changes post spinal fusion is limited. This study aimed to establish an in vitro model assessing mechanical effects of fusion on human lumbar facet joints, employing synchronized motion, pressure, and stiffness analysis. Methods and Results. Seven human lumbar spinal units (age 54 to 92, ethics 15/YH/0096) underwent fusion via a partial nucleotomy model mimicking a lateral cage approach with PMMA cement injection. Mechanical testing pre and post-fusion included measuring compressive displacement and load, local motion capture, and pressure mapping at the facet joints. pQCT imaging (82 microns isotropic) was carried out at each stage to assess the integrity of the vertebral endplates and quantify the amount of cement injected. Before fusion, relative facet joint displacement (6.5 ± 4.1 mm) at maximum load (1.1 kN) exceeded crosshead displacement (3.9 ± 1.5 mm), with loads transferred across both facet joints. After fusion, facet displacement (2.0 ± 1.2 mm) reduced compared to pre-fusion, as was the crosshead displacement (2.2 ± 0.6 mm). Post-fusion loads (71.4 ± 73.2 N) transferred were reduced compared to pre-fusion levels (194.5 ± 125.4 N). Analysis of CT images showed no endplate damage post-fusion, whilst the IVD tissue: cement volume ratio did not correlate with the post-fusion behaviour of the specimens. Conclusion. An in vitro model showed significant facet movement reduction with stand-alone interbody cage placement. This technique identifies changes in facet movement post-fusion, potentially contributing to subsequent spinal degeneration, highlighting its utility in biomechanical assessment. Conflicts of interest. None. Sources of funding. This work was funded by EPSRC, under grant EP/W015617/1


Bone & Joint Research
Vol. 10, Issue 12 | Pages 797 - 806
8 Dec 2021
Chevalier Y Matsuura M Krüger S Traxler H Fleege† C Rauschmann M Schilling C

Aims. Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods. Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S. 4. ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results. Experimental pull-out strengths were excellently correlated to the µFE pull-out stiffness of the ROI (R. 2. > 0.87) and FV (R. 2. > 0.84) models. No significant difference due to screw design was observed. Cement augmentation increased pull-out stiffness by up to 94% and 48% for L and R screws, respectively, but only increased bending stiffness by up to 6.9% and 1.5%, respectively. Cementing involving only one screw tip resulted in lower stiffness increases in all tested screw designs and loading cases. The stiffening effect of cement augmentation on pull-out and bending stiffness was strongly and negatively correlated to local bone density around the screw (correlation coefficient (R) = -0.95). Conclusion. This combined experimental, µCT and µFE study showed that regional analyses may be sufficient to predict fixation strength in pull-out and that full analyses could show that cement augmentation around pedicle screws increased fixation stiffness in both pull-out and bending, especially for low-density bone. Cite this article: Bone Joint Res 2021;10(12):797–806


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 679 - 687
1 Jun 2023
Lou Y Zhao C Cao H Yan B Chen D Jia Q Li L Xiao J

Aims

The aim of this study was to report the long-term prognosis of patients with multiple Langerhans cell histiocytosis (LCH) involving the spine, and to analyze the risk factors for progression-free survival (PFS).

Methods

We included 28 patients with multiple LCH involving the spine treated between January 2009 and August 2021. Kaplan-Meier methods were applied to estimate overall survival (OS) and PFS. Univariate Cox regression analysis was used to identify variables associated with PFS.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 97 - 102
1 Jan 2022
Hijikata Y Kamitani T Nakahara M Kumamoto S Sakai T Itaya T Yamazaki H Ogawa Y Kusumegi A Inoue T Yoshida T Furue N Fukuhara S Yamamoto Y

Aims

To develop and internally validate a preoperative clinical prediction model for acute adjacent vertebral fracture (AVF) after vertebral augmentation to support preoperative decision-making, named the after vertebral augmentation (AVA) score.

Methods

In this prognostic study, a multicentre, retrospective single-level vertebral augmentation cohort of 377 patients from six Japanese hospitals was used to derive an AVF prediction model. Backward stepwise selection (p < 0.05) was used to select preoperative clinical and imaging predictors for acute AVF after vertebral augmentation for up to one month, from 14 predictors. We assigned a score to each selected variable based on the regression coefficient and developed the AVA scoring system. We evaluated sensitivity and specificity for each cut-off, area under the curve (AUC), and calibration as diagnostic performance. Internal validation was conducted using bootstrapping to correct the optimism.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 629 - 633
1 May 2006
Ha K Lee J Kim K Chon J

We present the clinical and radiological results of percutaneous vertebroplasty in the treatment of 58 vertebral compression fractures in 51 patients at a minimum follow-up of two years. Group 1 consisted of 39 patients, in whom there was no associated intravertebral cleft, whilst group 2 comprised 12 patients with an intravertebral cleft. The Oswestry disability index (ODI) and visual analogue scale (VAS) scores were recorded prospectively. The radiological evidence of kyphotic deformity, vertebral height, leakage of cement and bone resorption around the cement were studied restrospectively, both before and after operation and at the final follow-up. The ODI and VAS scores in both groups decreased after treatment, but the mean score in group 2 was higher than that in group 1 (p = 0.02 (ODI), p = 0.02 (VAS)). There was a greater initial correction of the kyphosis in group 2 than in group 1, although the difference was not statistically significant. However, loss of correction was greater in group 2. Leakage of cement was seen in 24 (41.4%) of 58 vertebrae (group 1, 32.6% (15 of 46); group 2, 75% (9 of 12)), mainly of type B through the basal vertebral vein in group 1 and of type C through the cortical defect in group 2. Resorption of bone around the cement was seen in three vertebrae in group 2 and in one in group 1. There were seven adjacent vertebral fractures in group 1 and one in group 2. Percutaneous vertebroplasty is an effective treatment for osteoporotic compression fractures with or without an intravertebral cleft. Nonetheless, higher rates of complications related to the cement must be recognised in patients in the presence of an intravertebral cleft


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1282 - 1288
1 Sep 2010
Shen GW Wu NQ Zhang N Jin ZS Xu J Yin GY

This study prospectively compared the efficacy of kyphoplasty using a Jack vertebral dilator and balloon kyphoplasty to treat osteoporotic compression fractures between T10 and L5. Between 2004 and 2009, two groups of 55 patients each underwent vertebral dilator kyphoplasty and balloon kyphoplasty, respectively. Pain, function, the Cobb angle, and the anterior and middle height of the vertebral body were assessed before and after operation. Leakage of bone cement was recorded. The post-operative change in the Cobb angle was significantly greater in the dilator kyphoplasty group than in the balloon kyphoplasty group (−9.51° (. sd. 2.56) vs −7.78° (. sd. 1.19), p < 0.001)). Leakage of cement was less in the dilator kyphoplasty group. No other significant differences were found in the two groups after operation, and both procedures gave equally satisfactory results in terms of all other variables assessed. No serious complications occurred in either group. These findings suggest that vertebral dilator kyphoplasty can facilitate better correction of kyphotic deformity and may ultimately be a safer procedure in reducing leakage of bone cement


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 379 - 384
1 Mar 2009
Muijs SPJ Nieuwenhuijse MJ Van Erkel AR Dijkstra PDS

In a prospective study between August 2002 and August 2005, we studied the quantitative clinical and radiological outcome 36 months after percutaneous vertebroplasty for intractable type-II osteoporotic vertebral compression fractures which had been unresponsive to conservative treatment for at least eight weeks. We also examined the quality of life (QoL). The clinical follow-up involved the use of a pain intensity numerical rating scale (PI-NRS, 0 to 10), the Short-Form 36 (SF-36) QoL questionnaire and an anamnestic questionnaire before and at seven days (PI-NRS only), and one, three, 12 and 36 months post-operatively. A total of 30 consecutive patients received percutaneous vertebroplasty for 62 vertebral compression fractures with a mean time between fracture and treatment of 7.7 months (2.2 to 39). An immediate, significant and lasting reduction in the average and worst back pain was found, represented by a decrease of 3.1 and 2.7 points after seven days and 3.1 and 2.8 points after 36 months, respectively (p < 0.00). Comparison of the pre- and post-vertebroplasty scores on the various SF-36 domains showed an ultimate significant increase in six of eight domains and both summary scores. Asymptomatic leakage of cement was found in 47 of 58 (81%) of treated vertebrae. Two minor complications occurred, an asymptomatic pulmonary cement embolism and a cement spur along the needle track. Percutaneous vertebroplasty in the treatment of chronic vertebral compression fractures results in an immediate, significant and lasting reduction in back pain, and overall improvement in physical and mental health


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 401 - 406
1 Mar 2013
Rebolledo BJ Gladnick BP Unnanuntana A Nguyen JT Kepler CK Lane JM

This is a prospective randomised study comparing the clinical and radiological outcomes of uni- and bipedicular balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures. A total of 44 patients were randomised to undergo either uni- or bipedicular balloon kyphoplasty. Self-reported clinical assessment using the Oswestry Disability Index, the Roland-Morris Disability questionnaire and a visual analogue score for pain was undertaken pre-operatively, and at three and twelve months post-operatively. The vertebral height and kyphotic angle were measured from pre- and post-operative radiographs. Total operating time and the incidence of cement leakage was recorded for each group. Both uni- and bipedicular kyphoplasty groups showed significant within-group improvements in all clinical outcomes at three months and twelve months after surgery. However, there were no significant differences between the groups in all clinical and radiological outcomes. Operating time was longer in the bipedicular group (p < 0.001). The incidence of cement leakage was not significantly different in the two groups (p = 0.09). A unipedicular technique yielded similar clinical and radiological outcomes as bipedicular balloon kyphoplasty, while reducing the length of the operation. We therefore encourage the use of a unipedicular approach as the preferred surgical technique for the treatment of osteoporotic vertebral compression fractures. Cite this article: Bone Joint J 2013;95-B:401–6


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1099 - 1105
1 Aug 2016
Weiser L Dreimann M Huber G Sellenschloh K Püschel K Morlock MM Rueger JM Lehmann W

Aims. Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation. Materials and Methods. A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11/12 to L2/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force. Results. Augmentation showed no significant increase in the mean cycles to failure and fatigue force (SHORT p = 0.067; EXTENDED p = 0.239). Extending the instrumentation resulted in a significantly increased number of cycles to failure and a significantly higher fatigue force compared with the SHORT instrumentation (EXTENDED non-augmented + 76%, p < 0.001; EXTENDED augmented + 87%, p < 0.001). Conclusion. The stabilising effect of cement augmentation of pedicle screws might not be as beneficial as expected from biomechanical pull-out tests. Lengthening the dorsal instrumentation results in a much higher increase of stability during fatigue testing in the osteoporotic spine compared with cement augmentation. Cite this article: Bone Joint J 2016;98-B:1099–1105


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1553 - 1557
1 Nov 2010
Wang G Yang H Chen K

We investigated the safety and efficacy of treating osteoporotic vertebral compression fractures with an intravertebral cleft by balloon kyphoplasty. Our study included 27 patients who were treated in this way. The mean follow-up was 38.2 months (24 to 54). The anterior and middle heights of the vertebral body and the kyphotic angle were measured on standing lateral radiographs before surgery, one day after surgery, and at final follow-up. Leakage of cement was determined by CT scans. A visual analogue scale and the Oswestry disability index were chosen to evaluate pain and functional activity. Statistically significant improvements were found between the pre- and post-operative assessments (p < 0.05) but not between the post-operative and final follow-up assessments (p > 0.05). Asymptomatic leakage of cement into the paravertebral vein occurred in one patient, as did leakage into the intervertebral disc in another patient. We suggest that balloon kyphoplasty is a safe and effective minimally invasive procedure for the treatment of osteoporotic vertebral compression fractures with an intravertebral cleft


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 119 - 119
1 Apr 2012
Borse VH Millner P Hall R Kupur N
Full Access

To investigate and compare the biomechanical characteristics of Bipedicular versus Unipedicular Vertebroplasty in cadaveric vertebra. Cadaveric single level vertebra were used to evaluate Bipedicular versus Unipedicular Vertebroplasty as an intervention for vertebral compression fractures. Cadaveric vertebra were assigned to two arms: Arm A simulated a wedge fracture followed by bipedicular cement augmentation; Arm B simulated a wedge fracture followed by unipedicular cement augmentation. Micro-CT imaging was performed to assess vertebral dimension, cement fill volumes and bone mineral density. All augmented specimens were then compressed under a static eccentric flexion load to failure. Pre and post augmentation failure load and stiffness were used to compare the two groups. Results suggest, when compared with actual failure strength, that the product of bone mineral density and endplate surface area gave a good prediction of failure strength for specimens in both arms. The mean cement volume fill of augmented vertebral bodies was 22.8% ± 7.21%. The bipedicular group showed a reduction in stiffness but an increase in post augmentation failure load of 1.09. The unipedicular group also showed a reduction in stiffness but showed a much greater increase in post augmentation failure load of 1.68. Preliminary data from this study suggests there is a significant reduction in stiffness following both bipedicular and unipedicular vertebroplasty. There is a significant increase in failure load post augmentation in the unipedicular group


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 144 - 144
1 Apr 2012
John J Bommireddy R Klezl Z
Full Access

Clinical and radiological assessment of results of vertebral body stenting procedure. Introduction: Use of metallic stents along with cement have shown good restoration of the vertebral body in cadaveric spines. We have presented the early results of vertebral body stenting done at Royal Derby Hospitals. Patients and Methods: All patients had a transpedicular approach to the vertebral body. The vertebral body stent was expanded using a balloon as in balloon kyphoplasty. The balloon was removed leaving the stent in place. The resultant cavity was filled with partially cured polymethyl methacrylate in osteoporotic fractures and calcium phosphate cement in traumatic fractures. Radiological assessment included pre operative measurement of vertebral body angle, correction achieved and maintenance of correction at follow up. All patients were assessed using the visual analogue score and oswestry disability index. The procedure was done in 14 fractures (10 patients). 9 fractures were traumatic while 5 were osteoporotic fractures. The mean age of the traumatic fractures was 54.28 years while the mean age of osteoporotic fractures was 82.34 years. Mean follow up was 10 months. All traumatic fractures were type A 3.1. Mean vertebral body angle correction achieved was 8.3° (4° to 14.2°). None of the patients lost the reduction at follow up. The mean VAS for pain at 6 months was 3.8. The mean oswestry disability index was 22% for traumatic fractures, while it was 44% for osteoporotic fractures. Vertebral body stenting is a safe procedure. It was successful in restoring the anterior column with encouraging radiological and clinical results


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_I | Pages 29 - 29
1 Jan 2012
Luo J Annesley-Williams D Adams M Dolan P
Full Access

Introduction. Vertebral osteoporotic fracture increases both elastic and time-dependent (‘creep’) deformations of the fractured vertebral body during subsequent loading. This is especially marked in central and anterior regions of the vertebral body, and could explain the development of kyphotic deformity in life. We hypothesise that vertebroplasty can reduce these creep deformations. Methods. Twelve pairs of spine specimens, each comprising three vertebrae and the intervening soft tissue, were obtained from cadavers aged 67-92 yr. They were compressed to failure, after which one of each pair underwent vertebroplasty with polymethylmethacrylate cement, the other with a resin (Cortoss). A 1kN compressive force was applied for 1 hour before fracture, after fracture, and after vertebroplasty, while creep deformation was measured in the anterior, middle, and posterior region of each vertebral body using a MacReflex optical tracking system. Results. Cement type had little influence on creep deformation, so data from all 24 specimens were pooled. After fracture, creep in the anterior vertebral body increased from 4,863 (STD 5060) to 57,674 (STD 57,663) microstrains (P<0.001), and creep in the central vertebral body increased from 738 (STD 5,643) to 37,025 (STD 43,519) microstrain (P<0.001). Vertebroplasty reduced creep deformations by 67% (P=0.002) and 66% (P=0.011) in the anterior and central regions respectively. Conclusion. Vertebroplasty reduces progressive creep deformations of a fractured vertebral body. These findings suggest that vertebroplasty may slow or prevent the development of kyphotic deformity following vertebral osteoporotic fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 495 - 502
1 Apr 2007
Hadjipavlou A Tosounidis T Gaitanis I Kakavelakis K Katonis P

Vertebral haemangiomas are usually asymptomatic and discovered fortuitously during imaging. A small proportion may develop variable degrees of pain and neurological deficit. We prospectively studied six patients who underwent eight surgical procedures on 11 vertebral bodies. There were 11 balloon kyphoplasties, six lumbar and five thoracic. The mean follow-up was 22.3 months (12 to 36). The indications for operation were pain in four patients, severe back pain with Frankel grade C paraplegia from cord compression caused by soft-tissue extension from a thoracic vertebral haemangioma in one patient, and acute bleeding causing Frankel grade B paraplegia from an asymptomatic vascular haemangioma in one patient. In four patients the exhibited aggressive vascular features, and two showed lipomatous, non-aggressive, characteristics. One patient who underwent a unilateral balloon kyphoplasty developed a recurrence of symptoms from the non-treated side of the vertebral body which was managed by a further similar procedure. Balloon kyphoplasty was carried out successfully and safely in all patients; four became asymptomatic and two showed considerable improvement. Neurological recovery occurred in all cases but bleeding was greater than normal. To avoid recurrence, complete obliteration of the lesion with bone cement is indicated. For acute bleeding balloon kyphoplasty should be combined with emergency decompressive laminectomy. For intraspinal extension with serious neurological deficit, a combination of balloon kyphoplasty with intralesional alcohol injection is effective


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_15 | Pages 28 - 28
1 Oct 2014
Molloy S Sewell MD Patel AS Fahmy A Platinum J Selvadurai S Hargunani R Kyriakou C
Full Access

This study assesses whether balloon kyphoplasty (BKP) can safely restore height and correct deformity for cancer-related vertebral compression fractures (VCFs) involving the posterior vertebral body wall (PVBW), which is normally considered a relative contraindication. Retrospective cohort study of 158 patients (99M:59F; mean age 63 years) with 228 cancer-related VCFs, who underwent BKP. 112 had VCFs with PVBW defects, and 46 had VCFs with no PVBW defect. Data was assessed preoperatively and at 3 months. In the PVBW defect group, mean pain score decreased from 7.5 to 3.6 (p<0.001). There was a significant decrease in kyphotic angle (p<0.01), anterior vertebral body height (AVBH) (p<0.01) and mid-vertebral body height (MVBH) (p<0.05). In the PVBW intact group, mean pain score decreased from 7.3 to 3.3 (p<0.001). There was a significant improvement in AVBH and MVBH (p<0.001). When comparing groups, kyphotic angle, AVBH and MVBH were significantly worse in the PVBW defect group (P<0.05). More cement leaks occurred in the PVBW defect group. BKP can alleviate pain but does not restore height or correct kyphosis in patients with cancer-related VCFs and PVBW defects. There is no appreciable increase in surgical risk


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 516 - 521
1 Apr 2018
Qian L Jiang C Sun P Xu D Wang Y Fu M Zhong S Ouyang J

Aims

The aim of this study was to compare the peak pull-out force (PPF) of pedicle-lengthening screws (PLS) and traditional pedicle screws (TPS) using instant and cyclic fatigue testing.

Materials and Methods

A total of 60 lumbar vertebrae were divided into six groups: PLS submitted to instant pull-out and fatigue-resistance testing (groups A1 and A2, respectively), TPS submitted to instant pull-out and fatigue-resistance testing (groups B1 and B2, respectively) and PLS augmented with 2 ml polymethylmethacrylate, submitted to instant pull-out and fatigue-resistance testing (groups C1 and C2, respectively). The PPF and normalized PPF (PPFn) for bone mineral density (BMD) were compared within and between all groups.