header advert
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 305 - 305
1 Sep 2012
Majeed H Klezl Z Bommireddy R
Full Access

Introduction. The main symptoms in multiple myeloma are the result of skeletal destruction mainly the vertebral column. The current treatments for multiple myeloma include radiotherapy and chemotherapy but unfortunately it is still incurable. However, the symptoms and quality of life of these patients can be improved by cement augmentation which has gained popularity in the recent years. Aim. To analyse the efficacy and safety of cement augmentation and to assess the survival and outcome of the patients with vertebral fractures secondary to multiple myeloma. Material and Methods. In this retrospective study, we reviewed the data over the last 3 years. Medical records review included correction of vertebral angle (VA), assessment of disability, survival and postoperative improvement in pain and functional status. Results. We reviewed 12 patients with 48 vertebral compression fractures including 9 male and 3 female patients. Mean age was 62.5 years (41–85). 5 patients had single vertebral involvement while 7 had multiple fractures at different levels in thoracolumbar spine. Average length of follow-up was 20.3 months (14–33 months). Based on Modified Tokuhashi score, the expected survival was less than 12 months in 2 patients and more than 12 months in the remaining patients. 11 patients are alive till date with average survival of 26 months (18–42 months) while 1 patient died, 23 months after the initial correction surgery. Prior to correction, the average vertebral angle (VA) was 10.60 (2.30 to 25.20) and after cement augmentation the average VA was 7.00 (1.60–22.80). Mean correction achieved was 3.60. There was no loss of vertebral height in any patient until their latest follow-up. Karnofsky performance score was more than 70 in 5 patients, 50–70 in 6 and less than 50 in 1 patient preoperatively while it improved to more than 70 in all patients postoperatively which indicates improvement in their functional status. All patients reported improvement in their pain level after surgery. No cement leakage or major complication occurred in these patients. Conclusion. Cement augmentation is a safe and effective way of treating the symptoms of multiple myeloma which occur due to vertebral metastases. It results in excellent pain control and improvement in quality of life


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 418 - 418
1 Sep 2012
Goost H Karius T Deborre C Kabir K Randau T Burger C Wirtz D Pflugmacher R
Full Access

Introduction

Pedicle screw pullout or loosening is increased in the osteoporotic spine. Recent studies showed a significant increase of pullout forces especially for PMMA-augmentation. With application of conventional viscosity PMMA the risk of cement extravasation is associated. This risk can be reduced by using radiofrequency-responsive, ultrahigh viscosity bone cement.

Method

11 fresh-frozen lumbar vertebral bodies (VB) from 5 cadavers were collected and freed from soft-tissue and ligaments. By DEXA scan (Siemens QDR 2000) 8 VB were identified as severely osteoporotic (BMD 0.8 g/cm3), 3 VB were above this level. Two screws (6×45 mm, WSI-Expertise Inject, Peter Brehm, Weisendorf, Germany) were placed in the pedicles. Through the right screw 3ml of radiofrequency-responsive bone cement (StabiliT® ER2 Bone Cement, DFine, Germany) were injected via hydraulic cement delivery system (StabiliT® Vertebral Augmentation System, DFine, Germany). As control group, left pedicle screws remained uncemented. After potting the whole VB in technical PMMA (Technovit 4004, Heraeus Kulzer, Germany) axial pullout test was performed by a material testing device (Zwick-Roell, Zmart-Pro, Ulm, Germany).


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1406 - 1409
1 Oct 2013
Wähnert D Lange JH Schulze M Gehweiler D Kösters C Raschke MJ

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (sd 0.08) vs augmented 0.13 mm (sd 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (sd 0.02) vs augmented 0.15 mm (sd 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017).

Cite this article: Bone Joint J 2013;95-B:1406–9.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 997 - 1008
1 Aug 2022

Aims

The aim of this study was to describe the management and associated outcomes of patients sustaining a femoral hip periprosthetic fracture (PPF) in the UK population.

Methods

This was a multicentre retrospective cohort study including adult patients who presented to 27 NHS hospitals with 539 new PPFs between 1 January 2018 and 31 December 2018. Data collected included: management strategy (operative and nonoperative), length of stay, discharge destination, and details of post-treatment outcomes (reoperation, readmission, and 30-day and 12-month mortality). Descriptive analysis by fracture type was performed, and predictors of PPF management and outcomes were assessed using mixed-effects logistic regression.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 37 - 45
19 Jan 2024
Alm CE Karlsten A Madsen JE Nordsletten L Brattgjerd JE Pripp AH Frihagen F Röhrl SM

Aims

Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone.

Methods

Overall, 31 patients with AO/OTA 31-A2 trochanteric fractures were randomized to either a SHS alone or a SHS with an additional TSP. To compare postoperative fracture motion, radiostereometric analysis (RSA) was performed before and after weightbearing, and then at four, eight, 12, 26, and 52 weeks. With the “after weightbearing” images as baseline, we calculated translations and rotations, including shortening and medialization of the femoral shaft.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 951 - 957
1 Jul 2017
Poole WEC Wilson DGG Guthrie HC Bellringer SF Freeman R Guryel E Nicol SG

Aims

Fractures of the distal femur can be challenging to manage and are on the increase in the elderly osteoporotic population. Management with casting or bracing can unacceptably limit a patient’s ability to bear weight, but historically, operative fixation has been associated with a high rate of re-operation. In this study, we describe the outcomes of fixation using modern implants within a strategy of early return to function.

Patients and Methods

All patients treated at our centre with lateral distal femoral locking plates (LDFLP) between 2009 and 2014 were identified. Fracture classification and operative information including weight-bearing status, rates of union, re-operation, failure of implants and mortality rate, were recorded.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 391 - 397
1 Mar 2015
van Embden D Stollenwerck GANL Koster LA Kaptein BL Nelissen RGHH Schipper IB

The aim of this study was to quantify the stability of fracture-implant complex in fractures after fixation. A total of 15 patients with an undisplaced fracture of the femoral neck, treated with either a dynamic hip screw or three cannulated hip screws, and 16 patients with an AO31-A2 trochanteric fracture treated with a dynamic hip screw or a Gamma Nail, were included. Radiostereometric analysis was used at six weeks, four months and 12 months post-operatively to evaluate shortening and rotation.

Migration could be assessed in ten patients with a fracture of the femoral neck and seven with a trochanteric fracture. By four months post-operatively, a mean shortening of 5.4 mm (-0.04 to 16.1) had occurred in the fracture of the femoral neck group and 5.0 mm (-0.13 to 12.9) in the trochanteric fracture group. A wide range of rotation occurred in both types of fracture. Right-sided trochanteric fractures seem more rotationally stable than left-sided fractures.

This prospective study shows that migration at the fracture site occurs continuously during the first four post-operative months, after which stabilisation occurs. This information may allow the early recognition of patients at risk of failure of fixation.

Cite this article: Bone Joint J 2015;97-B:391–7.