The hip's capsular ligaments (CL) passively restrain extreme range of motion (ROM) by wrapping around the native femoral head/neck, and protect against impingement and instability. We compared how CL function was affected by device (hip resurfacing arthroplasty, HRA; dual mobility total hip arthroplasty, DM-THA; and conventional THA, C-THA), and surgical approach (anterior and posterior), with and without CL surgical-repair. We hypothesized that CL function would only be preserved when native head-size (HRA/DM-THA) was restored. CL function was quantified on sixteen cadaveric hips, by measuring ROM by internally (IR) and externally rotating (ER) the hip in six functional positions, ranging from full extension with abduction to full flexion with adduction (squatting). Native ROM was compared to ROM after posterior
We have developed an animal model to examine the formation of heterotopic ossification using standardised muscular damage and implantation of a beta-tricalcium phosphate block into a hip
Introduction. Even in localized collapse due to osteonecrosis of the femoral head, a femoral head can be preserved by rotational osteotomy. In addition to anterior rotation, originally described by Sugioka, much more correction can be obtained by posterior rotation. But, transtrochanteric rotational osteotomy needs rather extensive soft tissue release, such as complete
Introduction. The purpose of this study was to examine if Sugioka's transtrochanteric rotational osteotomy (TRO) of the femoral head could be a valid option in treating idiopathic osteonecrosis of the femoral head. Methods. Thirty-two TROs performed in 29 patients between 1985 and 2006 were studied. Patient age at operation ranged from 16 to 56 years (average, 36 years). Thirteen hips were in women and 19 hips in men. Height was 165 cm and weight 63 kg (Body Mass Index 23) on average. Risk factors were corticosteroid use in 18 hips and excessive alcohol consumption in 15 hips (2 of them had both backgrounds), while neither of them was found with 1 hip. Bilateral hips were affected in 19 patients and 3 of them underwent bilateral TROs sequentially. The femoral head was rotated anteriorly in 26 hips and posteriorly in 6 hips. For fixation of the osteotomy site, large femoral screws had been used till 1995 (Group 1, 9 hips), and since 1996 an AO angle plate or a compression hip screw has been used (Group 2, 13 hips). Since 2003, pre-operative planning was performed more meticulously and the distal part of the joint capsule was cut after osteotomy as described by Atsumi (Group 3, 10 hips). The average follow-up period was 6.5 years (range, 2 to 21 years). Results. The average Japanese Orthopaedic Association hip score was 55 points pre-operatively, 63 points at 1 year, and 61 points at the latest follow-up. With pain increase, re-collapse of the rotated femoral head, fracture of the proximal fragment, nonunion, trochanteric detachment, joint space narrowing, osteoarthritic changes, or infection as the endpoint, the survival rate was 58% at 1 year, 53% at 4 - 9 years. The endpoint developed in 14 hips (re-collapse of the rotated femoral head in 9, fracture of the proximal fragment in 3, joint space narrowing in 1, and infection in 1). The changes in the surgical techniques were suggested to have improved the 3-year survivorship: 25% in Group 1, 54% in Group 2, and 74% in Group 3. The 4- to 9-year survival of this procedure was 53%. The majority of the endpoints developed within the first year, which may suggest that most of them were surgery-related. Conclusion. This procedure requires precise and meticulous precautions in pre-operative planning, preservation of the posterior column vessels during surgery,
Reported rates of dislocation in hip hemiarthroplasty
(HA) for the treatment of intra-capsular fractures of the hip, range
between 1% and 10%. HA is frequently performed through a direct
lateral surgical approach. The aim of this study is to determine
the contribution of the anterior capsule to the stability of a cemented
HA through a direct lateral approach. A total of five whole-body cadavers were thawed at room temperature,
providing ten hip joints for investigation. A Thompson HA was cemented
in place via a direct lateral approach. The cadavers were then positioned
supine, both knee joints were disarticulated and a digital torque
wrench was attached to the femur using a circular frame with three
half pins. The wrench applied an external rotation force with the
hip in extension to allow the hip to dislocate anteriorly. Each
hip was dislocated twice; once with a capsular repair and once without
repairing the capsule. Stratified sampling ensured the order in
which this was performed was alternated for the paired hips on each
cadaver. Comparing peak torque force in hips with the capsule repaired
and peak torque force in hips without repair of the capsule, revealed
a significant difference between the ‘capsule repaired’ (mean 22.96
Nm, standard deviation ( Cite this article:
The objective of this study was to develop a test for the rapid (within 25 minutes) intraoperative detection of bacteria from synovial fluid to diagnose periprosthetic joint infection (PJI). The 16s rDNA test combines a polymerase chain reaction (PCR) for amplification of 16s rDNA with a lateral flow immunoassay in one fully automated system. The synovial fluid of 77 patients undergoing joint aspiration or primary or revision total hip or knee surgery was prospectively collected. The cohort was divided into a proof-of-principle cohort (n = 17) and a validation cohort (n = 60). Using the proof-of-principle cohort, an optimal cut-off for the discrimination between PJI and non-PJI samples was determined. PJI was defined as detection of the same bacterial species in a minimum of two microbiological samples, positive histology, and presence of a sinus tract or intra-articular pus.Objectives
Methods
An experimental piglet model induces avascular necrosis (AVN)
and deformation of the femoral head but its secondary effects on
the developing acetabulum have not been studied. The aim of this
study was to assess the development of secondary acetabular deformation
following femoral head ischemia. Intracapsular circumferential ligation at the base of the femoral
neck and sectioning of the ligamentum teres were performed in three
week old piglets. MRI was then used for qualitative and quantitative
studies of the acetabula in operated and non-operated hips in eight
piglets from 48 hours to eight weeks post-surgery. Specimen photographs and
histological sections of the acetabula were done at the end of the
study. Objectives
Methods
In order to determine the potential for an internervous safe zone, 20 hips from human cadavers were dissected to map out the precise pattern of innervation of the hip capsule. The results were illustrated in the form of a clock face. The reference point for measurement was the inferior acetabular notch, representing six o’clock. Capsular branches from between five and seven nerves contributed to each hip joint, and were found to innervate the capsule in a relatively constant pattern. An internervous safe zone was identified anterosuperiorly in an arc of 45° between the positions of one o’clock and half past two. Our study shows that there is an internervous zone that could be safely used in a capsule-retaining anterior, anterolateral or lateral approach to the hip, or during portal placement in hip arthroscopy.
Repeated trauma to the radial head may be one of the causative factors in the genesis of osteochondritis dissecans of the capitellum. We measured the force, contact area and pressure across the radiocapitellar articulation of the elbow before and after radial shortening osteotomy in five fresh-frozen cadaver upper limbs with loads of 45, 90 and 135 N, respectively. Measurements were made on pressure-sensitive film placed in the radiocapitellar articulation with the forearm in the supinated, neutral and pronated positions before and after radial shortening. Radial shortening significantly reduced the mean force and contact area across the radiocapitellar articulation in all positions of the forearm.
A cadaver study using six pairs of lower limbs was conducted to investigate the accuracy of computer navigation and standard instrumentation for the placement of the Birmingham Hip Resurfacing femoral component. The aim was to place all the femoral components with a stem-shaft angle of 135°. The mean stem-shaft angle obtained in the standard instrumentation group was 127.7° (120° to 132°), compared with 133.3° (131° to 139°) in the computer navigation group (p = 0.03). The scatter obtained with computer-assisted navigation was approximately half that found using the conventional jig. Computer navigation was more accurate and more consistent in its placement of the femoral component than standard instrumentation. We suggest that image-free computer-assisted navigation may have an application in aligning the femoral component during hip resurfacing.