Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 43 - 43
1 Aug 2013
Changulani M Sankar B Deakin A Picard F
Full Access

Distal femur resection for correction of flexion contractures in total knee arthroplasty (TKA) can lead to joint line elevation, abnormal knee kinematics and patellofemoral problems. The aim of this retrospective study was to establish the contribution of soft tissue releases and bony cuts in the change in maximum knee extension in TKA. Data were available for 211 TKAs performed by a single surgeon using a medial approach. Intra-operatively pre- and post-implant extension angles and the size of bone resection were collected using a commercial navigation system. The thickness of polyethylene insert and the extent of soft tissue release performed (no release, moderate and extensive release) were collected from the patient record. A linear model was used to predict change in maximum extension from pre- to post-implant. The analysis showed that bone cuts (p<0.001), soft tissue release (p=0.001) and insert thickness (p=0.010) were all significant terms in the model (r. 2. adj. =0.170). This model predicted that carrying out a TKA with 19 mm bone cuts, 10 mm insert and no soft tissue release would give 4.2° increase in extension. It predicted that a moderate release would give a further 2.8° increase in extension with an extensive release giving 3.9°. For each mm increase in bone cuts the model predicted an 0.8° increase in extension and for each mm increase in insert size a decrease extension by 1.1°. The modelling results show that in general to increase maximum extension by the same as an extensive soft tissue release that bone cuts would have to be increased by 4–5 mm. However this model only accounted for 17% of the variation in change in extension pre- to post-implant so may not be accurate at predicting outcomes for specific patients


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 106 - 106
1 Nov 2021
Franceschetti E De Angelis D'Ossat G Palumbo A Paciotti M Franceschi F Papalia R
Full Access

Introduction and Objective. TKA have shown both excellent long-term survival rate and symptoms and knee function improvement. Despite the good results, the literature reports dissatisfaction rates around 20%. This rate of dissatisfaction could be due to the overstuff that mechanically aligned prostheses could produce during the range of motion. Either size discrepancy between bone resection and prosthetic component and constitutional mechanical tibiofemoral alignment (MTFA) alteration might increase soft tissue tension within the joint, inducing pain and functional limitation. Materials and Methods. Total knee arthroplasties performed between July 2019 and September 2020 were examined and then divided into two groups based on the presence (Group A) or absence (Group B) of patellofemoral overstuff, defined as a thickness difference of more than 2 mm between chosen component and bone resection performed, taking into account at least one of the following: femoral medial and lateral condyle, medial or lateral trochlea and patella. Based on pre and post-operative MTFA measurements, Group A was further divided into two subgroups whether the considered alignment was modified or not. Patients were assessed pre-operatively and at 6 months post-op using the Knee Society Score (KSS), Oxford Knee Score (OKS), Forgotten Joint Score (FJS), Visual Analogue Scale (VAS) and Range of Motion (ROM). Results. One hundred total knee arthroplasties were included in the present study, 69 in Group A and 31 in group B. Mean age and BMI of patients was respectively 71 and 29.2. The greatest percentage of Patellofemoral Overstuff was found at the distal lateral femoral condyle. OKS, KSS functional score, and FJS were statistically significant higher in patients without Patellofemoral Overstuff. Therefore, Group A patients with a non-modified MTFA demonstrated statistically significant better KSS, ROM and FJS. Conclusions. Patellofemoral Overstuff decrease post-operative clinical scores in patients treated with TKA. The conventional mechanically aligned positioning of TKA components might be the primary cause of prosthetic overstuffing leading to worsened clinical results. Level of evidence: III; Prospective Cohort Observational study;


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 94 - 94
11 Apr 2023
Funk G Horn E Kilway K Parrales A Iwakuma T McIff T
Full Access

Osteosarcoma and other types of bone cancers often require bone resection, and backfill with cement. A novel silorane-based cement without PMMA's drawbacks, previously developed for dental applications, has been reformulated for orthopedic use. The aim of this study is to assess each cement's ability to elute doxorubicin, maintain its potency, and maintain suitable weight-bearing strength. The silorane-based epoxy cement was synthesized using a platinum-based Lamoreaux's catalyst. Four groups of cement were prepared. Two PMMA groups, one without any additives, one with 200 mg of doxorubicin. Two silorane groups: one without any additive, one with doxorubicin, added so that the w% of drug into both cements were equal. Pellets 6 × 12 mm were used for testing (ASTM F451). n=10. Ten pellets from each group were kept dry. All others were placed into tubes containing 2.5 mL of PBS and stored at 37 °C. Elution from doxorubicin-containing groups were collected every day for 7 days, with daily PBS changeout. Antibiotic concentrations were determined via HPLC. Compressive strength and compressive modulus of all groups were determined for unsoaked specimens, and those soaked for 7 and 14 days. MTT assays were done using an MG63 osteosarcoma cell line. Both cements were able to elute doxorubicin over 7 days in clinically-favorable quantities. For PMMA samples, the incorporation of doxorubicin was shown to significantly affect the compressive strength and modulus of the samples (p<0.01). Incorporation of doxorubicin into silorane had no significant effect on either (p>.05). MTT assays indicated that doxorubicin incorporated into the silorane cement maintained its effectiveness whereas that into PMMA did not. At the dosing used, both cements remained above the 70 MPa. Both PMMA and silorane-based cements can deliver doxorubicin. Doxorubicin, however, interacts chemically with PMMA, inhibiting polymerization and lowering the chemotherapeutic's effectiveness


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 1 - 1
1 Dec 2022
Parchi P
Full Access

In the last years, 3d printing has progressively grown and it has reached a solid role in clinical practice. The main applications brought by 3d printing in orthopedic surgery are: preoperative planning, custom-made surgical guides, custom-made im- plants, surgical simulation, and bioprinting. The replica of the patient's anatomy, starting from the elaboration of medical volumetric images (CT, MRI, etc.), allows a progressive extremization of treatment personalization that could be tailored for every single patient. In complex cases, the generation of a 3d model of the patient's anatomy allows the surgeons to better understand the case — they can almost “touch the anatomy” —, to perform a more ac- curate preoperative planning and, in some cases, to perform device positioning before going to the surgical room (i.e. joint arthroplasty). 3d printing is also commonly used to produce surgical cutting guides, these guides are positioned intraoperatively on given landmarks to guide the surgeon to perform a specific surgical act (bone osteotomy, bone resection, implant position, etc.). In total knee arthroplasty, custom-made cutting guides have been developed to help the surgeon align the femoral and tibial components to the pre-arthritic condition with- out the use of the intramedullary femoral guide. 3d printed custom-made implants represent an emerging alternative to biological reconstructions especially after oncologic resection surgery or in case of complex arthroplasty revision surgery. Custom-made implants are designed to re- place the original shape and size of the patient's bone and they allow an extreme personalization of the treatment for every single patient. Patient-specific surgical simulation is a new frontier that promises great benefits for surgical training. a solid 3d model of the patient's anatomy can faithfully reproduce the surgical complexity of the patient and it allows to generate surgical simulators with increasing difficulty to adapt the difficulties of the course with the level of the trainees performing structured training paths: from the “simple” case to the “complex” case


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 25 - 25
14 Nov 2024
Taylan O Louwagie T Bialy M Peersman G Scheys L
Full Access

Introduction. This study aimed to evaluate the effectiveness of a novel intraoperative navigation platform for total knee arthroplasty (TKA) in restoring native knee joint kinematics and strains in the medial collateral ligament (MCL) and lateral collateral ligament (LCL) during squatting motions. Method. Six cadaver lower limbs underwent computed tomography scans to design patient-specific guides. Using these scans, bony landmarks and virtual single-line collateral ligaments were identified to provide intraoperative real-time feedback, aided in bone resection, implant alignment, tibiofemoral kinematics, and collateral ligament elongations, using the navigation platform. The specimens were subjected to squatting (35°-100°) motions on a physiological ex vivo knee simulator, maintaining a constant 110N vertical ankle load regulated by active quadriceps and bilateral hamstring actuators. Subsequently, each knee underwent a medially-stabilized TKA using the mechanical alignment technique, followed by a retest under the same conditions used preoperatively. Using a dedicated wand, MCL and LCL insertions—anterior, middle, and posterior bundles—were identified in relation to bone-pin markers. The knee kinematics and collateral ligament strains were analyzed from 3D marker trajectories captured by a six-camera optical system. Result. Both native and TKA conditions demonstrated similar patterns in tibial valgus orientation (Root Mean Square Error (RMSE=1.7°), patellar flexion (RMSE=1.2°), abduction (RMSE=0.5°), and rotation (RMSE=0.4°) during squatting (p>0.13). However, a significant difference was found in tibial internal rotation between 35° and 61° (p<0.045, RMSE=3.3°). MCL strains in anterior (RMSE=1.5%), middle (RMSE=0.8%), and posterior (RMSE=0.8%) bundles closely matched in both conditions, showing no statistical differences (p>0.05). Conversely, LCL strain across all bundles (RMSE<4.6%) exhibited significant differences from mid to deep flexion (p<0.048). Conclusion. The novel intraoperative navigation platform not only aims to achieve planned knee alignment but also assists in restoring native knee kinematics and collateral ligament behavior through real-time feedback. Acknowledgment. This study was funded by Medacta International (Castel San Pietro, Switzerland)


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 107 - 107
1 Nov 2021
Salini V
Full Access

Treatment of large bone defects represents a great challenge for orthopedic surgeons. The main causes are congenital abnormalities, traumas, osteomyelitis and bone resection due to cancer. Each surgical method for bone reconstruction leads its own burden of complications. The gold standard is considered the autologous bone graft, either of cancellous or cortical origin, but due to graft resorption and a limitation for large defect, allograft techniques have been identified. In the bone defect, these include the placement of cadaver bone or cement spacer to create the ‘Biological Chamber’ to restore bone regeneration, according to the Masquelet technique. We report eight patients, with large bone defect (for various etiologies and with an average size defect of 13.3 cm) in the lower and upper limbs, who underwent surgery at our Traumatology Department, between January 2019 and October 2020. Three patients were treated with both cortical and cancellous autologous bone grafts, while five received cortical or cement spacer allografts from donors. They underwent pre and postoperative radiographs and complete osseointegration was observed in all patients already undergoing monthly radiographic checks, with a restoration of length and range of motion. In our study, both the two stage-Masquelet and the cortical bone graft from a cadaver donor proved to be valid techniques in patients with very extensive defects to reconstruct the defect, restore the length, minimize implant left in situ and achieve complete functional recovery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 50 - 50
4 Apr 2023
Wang Z van den Beucken J van den Geest I Leeuwenburgh S
Full Access

Residual tumor cells left in the bone defect after malignant bone tumor resection can result in local tumor recurrence and high mortality. Therefore, ideal bone filling materials should not only aid bone reconstruction or regeneration, but also exert local chemotherapeutic efficacy. However, common bone substitutes used in clinics are barely studied in research for local delivery of chemotherapeutic drugs. Here, we aimed to use facile manufacturing methods to render polymethylmethacrylate (PMMA) cement and ceramic granules suitable for local delivery of cisplatin to limit bone tumor recurrence. Porosity was introduced into PMMA cement by adding 1-4% carboxymethylcellulose (CMC) containing cisplatin, and chemotherapeutic activity was rendered to two types of granules via adsorption. Then, mechanical properties, porosity, morphology, drug release kinetics, ex vivo reconstructive properties of porous PMMA and in vitro anti-cancer efficacy against osteosarcoma cells were assessed. Morphologies, molecular structures, drug release profiles and in vitro cytostatic effects of two different drug-loaded granules on the proliferation of metastatic bone tumor cells were investigated. The mechanical strengths of PMMA-based cements were sufficient for tibia reconstruction at CMC contents lower than 4% (≤3%). The concentrations of released cisplatin (12.1% and 16.6% from PMMA with 3% and 4% CMC, respectively) were sufficient for killing of osteosarcoma cells, and the fraction of dead cells increased to 91.3% within 7 days. Functionalized xenogeneic granules released 29.5% of cisplatin, but synthetic CaP granules only released 1.4% of cisplatin over 28 days. The immobilized and released cisplatin retained its anti-cancer efficacy and showed dose-dependent cytostatic effects on the viability of metastatic bone tumor cells. Bone substitutes can be rendered therapeutically active for anticancer efficacy by functionalization with cisplatin. As such, our data suggest that multi-functional PMMA-based cements and cisplatin-loaded granules represent viable treatment options for filling bone defects after bone tumor resection


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 5 - 5
1 Jul 2014
Porter A Snyder B Franklin P Ayers D
Full Access

Summary Statement. A prospective randomised evaluation of primary TKA utilizing patient specific instruments demonstrated great accuracy of bone resection, improved sagittal alignment and the potential to improve functional outcomes and reduce operating room costs when compared to standard TKA instrumentation. Introduction. Patient specific instruments (PSI), an alternative to standard total knee arthroplasty (TKA) technology, have been proposed to improve the accuracy of TKA implant placement and post-operative limb alignment. Previous studies have shown mixed results regarding the effectiveness of PSI. The purposes of this study were (1) to evaluate the accuracy of the pre-operative predicted PSI plan compared to intra-operative TKA resection measurements, (2) to compare patient-reported outcome measures of PSI and standard TKA patients, and (3) to compare the incremental cost savings with PSI. Patients and Methods. This randomised, prospective pilot study of 19 patients undergoing primary TKA with a cruciate-retaining cemented prosthesis (NexGen, Zimmer Inc.) was conducted by a single high-volume arthroplasty surgeon (DCA). Patients were randomised to PSI or standard instrumentation. Patients randomised to the PSI cohort received a pre-operative knee MRI for PSI fabrication using Zimmer proprietary software. 10 standard TKA and 9 PSI TKA were completed. Pre-operative baseline SF-36 and WOMAC scores were collected. Operative data collected included operating room times, implant details, femoral (medial/lateral distal and posterior) and tibial (medial/lateral) cut thicknesses, and number of instrument trays used. Hospitalization data collected included length of stay, blood loss, drain output, and transfusion requirements. Follow-up occurred at 2 weeks, 6–8 weeks, 3 months, 6 months, and 1 year, with SF-36 and WOMAC scores collected at each time point. Routine radiographic analysis was carried out in both cohorts. Extensive financial data was collected including costs of operating room use and anesthesia, implants, and hospitalization. Statistical analyses included t-tests for continuous variables and chi-square tests for categorical variables. Results. All femoral and tibial implant sizes used during TKA matched the component sizes predicted by the PSI software. Flexion gap bone resection (posterior medial/lateral femoral cuts) was extremely accurate (<1 mm on average) when compared with PSI predictions. PSI proximal tibial bone resection was also extremely accurate and within 1 mm on average of predicted values. Sagittal plane tibial component posterior slope in PSI TKA was significantly more accurate (7.33 degrees) in comparison to standard instrumentation (4.20 degrees) (p<0.025). No significant differences in coronal mechanical limb alignment existed between the two cohorts (p>0.05). There were no differences in operating room times, length of stay, or transfusions between the two groups. PSI patients used 4 fewer instrument trays per case (p<0.0001). There were no significant differences in functional outcome scores between the two groups (p>0.05). Discussion/Conclusion. PSI TKA demonstrated outstanding accuracy in bone resection when compared with the custom operative plan. There was no difference in post-operative coronal limb alignment or individual component alignment between the two groups, but an improvement in tibial component alignment in the sagittal plane in the PSI cohort was statistically significant. The number of instrument trays in PSI TKA's were significantly less than standard TKA which led to less cost for instrument sterilization and assembly, and quicker room set-up. PSI instrumentation resulted in accurate bone resection and appropriate limb and component alignment after primary TKA in this prospective randomised evaluation


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 53 - 53
1 Jan 2017
Devivier C Roques A Taylor A Heller M Browne M
Full Access

There is a critical need for safe innovation in total joint replacements to address the demands of an ageing yet increasingly active population. The development of robust implant designs requires consideration of uncertainties including patient related factors such as bone morphology but also activity related loads and the variability in the surgical procedure itself. Here we present an integrated framework considering these sources of variability and its application to assess the performance of the femoral component of a total hip replacement (THR). The framework offers four key features. To consider variability in bone properties, an automated workflow for establishing statistical shape and intensity models (SSIM) was developed. Here, the inherent relationship between shape and bone density is captured and new meshes of the target bone structures are generated with specific morphology and density distributions. The second key feature is a virtual implantation capability including implant positioning, and bone resection. Implant positioning is performed using automatically identified bone features and flexibly defined rules reflecting surgical variability. Bone resection is performed according to manufacturer guidelines. Virtual implantation then occurs through Boolean operations to remove bone elements contained within the implant's volume. The third feature is the automatic application of loads at muscle attachment points or on the joint contact surfaces defined on the SSIM. The magnitude and orientation of the forces are derived from models of similar morphology for a range of activities from a database of musculoskeletal (MS) loads. The connection to this MS loading model allows the intricate link between morphology and muscle forces to be captured. Importantly, this model of the internal forces provides access to the spectrum of loading conditions across a patient population rather than just typical or average values. The final feature is an environment that allows finite element simulations to be run to assess the mechanics of the bone-implant construct and extract results for e.g. bone strains, interface mechanics and implant stresses. Results are automatically processed and mapped in an anatomically consistent manner and can be further exploited to establish surrogate models for efficient subsequent design optimization. To demonstrate the capability of the framework, it has been applied to the femoral component of a THR. An SSIM was created from 102 segmented femurs capturing the heterogeneous bone density distributions. Cementless femoral stems were positioned such that for the optimal implantation the proximal shaft axis of the femurs coincided with the distal stem axis and the position of the native femoral head centre was restored. Here, the resection did not affect the greater trochanter and the implantations were clinically acceptable for 10000 virtual implantations performed to simulate variability in patient morphology and surgical variation. The MS database was established from musculoskeletal analyses run for a cohort of 17 THR subjects obtaining over 100,000 individual samples of 3D muscle and joint forces. An initial analysis of the mechanical performance in 7 bone-implant constructs showed levels of bone strains and implant stresses in general agreement with the literature


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 41 - 41
1 Jan 2017
Benassarou M Pazart L Gindraux F Meyer C
Full Access

Reconstructing mandibular and maxillary bone defects with free vascularized bone flaps requires to take into account the aesthetic and functional requirements to consider subsequent placement of dental implants. It implies a three-dimensional conformation of the bone fragment. This is usually done by making osteotomies on the bone harvested. The aim of our study was to evaluate the interest of virtual planning and 3D printing using free software and a consumer printer in this indication. Invesalius® software (Technology of Information Renato Archer Center, Campinas, Brazil) was used to build virtual models from the patients' CT scan imaging data. The surgical procedure was planned using Meshmixer® (Autodesk, San Rafael, United States). Meshlab® software (Visual Computing Lab, Pisa, Italy) was used to design cutting guides for the flap harvest and modelling. 3D printing of these guides with a consumer printer (Ultimaker 2® Ultimaker B.V., Geldermalsen, the Netherlands) allowed the transfer of the planning to the operating room. Three patients requiring mandibular reconstruction underwent an iliac crest free flap, a fibula free flap and a scapula free flap, and could benefit from this technique. In each case, the bone resection was performed virtually and the positioning of the bone available at the donor site was simulated on screen. This allowed to anticipate the position and orientation of the cutting planes on the bone flap. From the anatomy of the donor site and the cutting planes, harvest templates and cutting guides could be designed by computer. Planning the conformation of the bone flap to the recipient site has allowed an anatomical, aesthetic and functional reconstruction of the bone defect. Surgeon-made virtual planning and “low cost” 3D printing helps harvest the bone flap and position and orient the osteotomies to adapt it to the defect. They provide, both the patient and the surgeon, reduced operative time and better anticipation of the result, particularly in the context of the maxillofacial reconstruction. Compared to commercially available custom-made devices, this technique allows the manufacture of the guides without delay and at a cheap price


Bone & Joint Research
Vol. 9, Issue 4 | Pages 162 - 172
1 Apr 2020
Xie S Conlisk N Hamilton D Scott C Burnett R Pankaj P

Aims

Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.

Methods

This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 436 - 444
1 Apr 2000
van Loon CJM de Waal Malefijt MC Buma P Stolk PWT Verdonschot N Tromp AM Huiskes R Barneveld A

The properties of impacted morsellised bone graft (MBG) in revision total knee arthroplasty (TKA) were studied in 12 horses. The left hind metatarsophalangeal joint was replaced by a human TKA. The horses were then randomly divided into graft and control groups. In the graft group, a unicondylar, lateral uncontained defect was created in the third metatarsal bone and reconstructed using autologous MBG before cementing the TKA. In the control group, a cemented TKA was implanted without the bone resection and grafting procedure. After four to eight months, the animals were killed and a biomechanical loading test was performed with a cyclic load equivalent to the horse’s body-weight to study mechanical stability. After removal of the prosthesis, the distal third metatarsal bone was studied radiologically, histologically and by quantitative and micro CT. Biomechanical testing showed that the differences in deformation between the graft and the control condyles were not significant for either elastic or time-dependent deformations. The differences in bone mineral density (BMD) between the graft and the control condyles were not significant. The BMD of the MBG was significantly lower than that in the other regions in the same limb. Micro CT showed a significant difference in the degree of anisotropy between the graft and host bone, even although the structure of the area of the MBG had trabecular orientation in the direction of the axial load. Histological analysis revealed that all the grafts were revascularised and completely incorporated into a new trabecular structure with few or no remnants of graft. Our study provides a basis for the clinical application of this technique with MBG in revision TKA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 286 - 286
1 Jul 2014
Lee J Jeong C
Full Access

Summary Statement. The implantation of scaffold-free CTE from suspension culture into growth-plate defects resulted in a significant reduction in growth arrest of the rabbit tibia. Introduction. In childhood and adolescence, the growth plate injury can cause partial premature arrest of growth plate, which can make problems such as leg length discrepancy and angular deformity. Bone bridge resection and variable implantation materials such as fat, bone wax, silastic and craniopalst has been investigated. However, those procedures may show limitations including the control of bone growth and long term safety of implant materials in vivo. As an alternative, homogeneous or heterogeneous cartilage cells and stem cell transplants have been tried. In this method, scaffold for cell transplantation is needed. But, so far the most suitable scaffold has not been established. Recently, some authors generated a cartilage tissue equivalent (CTE) using a suspension culture with biophysical properties similar to native hyaline cartilage. Therefore we are able to transplant the CTE without scaffold to the physeal defect. The purpose of this study was to investigated the effects of a transplantation of a vitro-generated scaffold-free tissue-engineered cartilage tissue equivalent (CTE) using a suspension chondrocyte culture in a rabbit growth arrest model. Material and Method. Cartilage tissue equivalent culture. The CTE was generated by the suspension culture of chondrocytes (2 × 10. 7. /well/1 mL) which was isolated from articular cartilage of 5 weeks New Zealand white rabbit on a 24-well plate (2.4 cm. 2. /well) treated with poly HEMA (nunc, Roskide, Denmark) for up to 8 and 16 weeks. (2)Partial growth arrest animal model. An experimental model for growth arrest was created by excising the growth plate at the proximal medial side of tibia with the 4 mm in diameter and 4 mm in depth from 6-week-old New Zealand white rabbits. Two experimental groups were set to evaluate CTE implantation; group I, no implantation as controls; group II, implantation of CTE. (3) Evaluation of effect of the transplantation of CTE. Serial plain radiographs were performed at one week. The medial proximal tibial angle (MPTA) was measured for assessing the degree of angular deformity. Histologic examination using HE stain, Alcian bule and immunohistochemistry was done at 4 and 8 weeks after surgery. Results. Radiographic results: In group I, all damaged growth plates were arrested and angular deformities appeared 4 weeks later. In groups II, angular deformities were much less than in the control group. Histologic result: In group I, bone bridge formation was shown at the damaged growth plate at 4 weeks after surgery. In group II, regeneration of growth plates was recognised at 4 and 8 week after surgery. However, the thickness of regenerated growth plate at 8 weeks specimen was thinner than that of 4 weeks specimen. Discussion and Conclusion. The implantation of scaffold-free CTE from suspension culture into growth-plate defects resulted in a significant reduction in growth arrest of the rabbit tibia


Bone & Joint Research
Vol. 6, Issue 11 | Pages 631 - 639
1 Nov 2017
Blyth MJG Anthony I Rowe P Banger MS MacLean A Jones B

Objectives

This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group.

Methods

A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.


Bone & Joint Research
Vol. 6, Issue 3 | Pages 137 - 143
1 Mar 2017
Cho HS Park YK Gupta S Yoon C Han I Kim H Choi H Hong J

Objectives

We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model.

Methods

We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 865 - 874
1 Jul 2012
Mills LA Simpson AHRW

This review is aimed at clinicians appraising preclinical trauma studies and researchers investigating compromised bone healing or novel treatments for fractures. It categorises the clinical scenarios of poor healing of fractures and attempts to match them with the appropriate animal models in the literature.

We performed an extensive literature search of animal models of long bone fracture repair/nonunion and grouped the resulting studies according to the clinical scenario they were attempting to reflect; we then scrutinised them for their reliability and accuracy in reproducing that clinical scenario.

Models for normal fracture repair (primary and secondary), delayed union, nonunion (atrophic and hypertrophic), segmental defects and fractures at risk of impaired healing were identified. Their accuracy in reflecting the clinical scenario ranged greatly and the reliability of reproducing the scenario ranged from 100% to 40%.

It is vital to know the limitations and success of each model when considering its application.