The standard of surgical treatment for lower limb neoplasms had been characterized by highly interventional techniques, leading to severe kinetic impairment of the patients and incidences of phantom pain. Rotationplasty had arisen as a potent limb salvage treatment option for young cancer patients with lower limb bone tumours, but its impact on the gait through comparative studies still remains unclear several years after the introduction of the procedure. The aim of this study is to assess the effect of rotationplasty on gait parameters measured by gait analysis compared to healthy individuals. The MEDLINE, Scopus, and Cochrane databases were systematically searched without time restriction until 10 January 2022 for eligible studies. Gait parameters measured by gait analysis were the outcomes of interest.Aims
Methods
Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively.Aims
Methods
Aims. This study aimed to analyze the accuracy and errors associated with 3D-printed, patient-specific resection guides (3DP-PSRGs) used for
Objectives. We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of
Aims. Iliac wing (Type I) and iliosacral (Type I/IV) pelvic resections for a primary
INTRODUCTION.
Recently, several preliminary reports have been issued on the application of computer assistance to
Primary
Aims. We present a retrospective review of patients treated with extracorporeally
irradiated allografts for primary and secondary
Primary
Amputation was once widely practised for primary
Needle biopsy is an established technique for the histological diagnosis of
Background:The study aimed to analyse the demographic, clinical, and histological features of patients with a malignant primary
Between 1988 and 2006, 18 patients had a custom-made endoprosthetic replacement of the distal humerus for
Introduction: Only 4–13 % of all spine tumours are primary
The surgical treatment of
Endoprosthetic replacement of the distal tibia and ankle joint for a primary
INTRODUCTION. We conducted a review of the Leeds Regional
We report our experience with a new technique for cryosurgical ablation of