Background. Cement implantation syndrome characterized by hypotension, hypoxemia, cardiac arrhythmia or arrest has been reported in the literature. The purpose of the present study was to monitor
Purpose: Cement implantation syndrome characterized by hypotension, hypoxemia, cardiac arrhythmia or arrest has been reported in the literature. Pulmonary embolization is thought to be the main reason. In our institute, however, we have not experienced major hypotension during THA. To improve longevity of THA, interface bioactive bone cement technique combined with modern cementing technique has been used in our institute. Main principle of this technique is smearing hydroxyapatite granules on the dry bony surface followed by cement pressurization. The purpose of the present study was to monitor
This study reports the comparison of the clinical use of a new tourniquet system for total knee arthroplasty that can determine its pressure in synchrony with systolic
Aims. Hip fractures are some of the most common fractures encountered in orthopaedic practice. We aimed to identify whether perioperative hypotension is a predictor of 30-day mortality, and to stratify patient groups that would benefit from closer monitoring and early intervention. While there is literature on intraoperative
Prompt mobilisation after the Fracture neck of femur surgery is one of the important key performance index (‘KPI caterpillar charts’ 2021) affecting the overall functional outcome and mortality. Better control of peri-operative
Purpose of study and background. Psychological factors are considered to play a role in development and maintenance of chronic low back pain (CLBP). Stress or anxiety can change pain sensitivity; however, this has predominantly been studied in healthy individuals with limited work in individuals with musculoskeletal pain. The objective of this study was to quantify the effect of acute exposure to a psychosocial stressor on mechanical pain sensitivity in individuals with and without CLBP. Summary of methods and results. Six individuals with CLBP and 10 individuals without CLBP performed a 10-minute computer task under conditions of low and high psychosocial stress. Psychosocial stress was manipulated using mental maths and memory tasks combined with social evaluative threat. The effect of the stressor was evaluated using
Abstract. Objective. To investigate the safety and cost-effectiveness of interscalene brachial plexus block/regional anaesthesia (ISB-RA) in patients undergoing reverse total shoulder replacement. Methods. This retrospective study included 15 patients with symptomatic rotator cuff arthropathy who underwent reverse total shoulder arthroplasty (rTSA) under ISB-RA without general anaesthesia in the beach chair position from 2010 to 2018. The mean patient age was 77 years (range 59–82 years). Patients had associated medical comorbidities: American Society of Anesthesiologists (ASA) grade 2–4. Assessed parameters were: duration of anaesthesia, intra-operative systolic
To compare the incidence of Bone Cement Implantation Syndrome (BCIS), perioperative thromboembolic events and mortality in patients with a femoral neck fracture (FNF) treated with a hybrid total hip arthroplasty (THA) without intraoperative unfractioned heparin (UFH) (control) versus a group of patients who received intraoperative UFH before femoral cementation. We retrospectively reviewed 273 patients who underwent hybrid THA due to a FNF between 2015 and 2020. We compared a group of 139 patients without intraoperative administration of UFH (group A) with 134 patients who underwent THA with intraoperative administration of 10 UI/kg UFH (group B). UFH indication was dependent on surgeon´s preference. We assessed the advent of BCIS and 30-day thromboembolic events, as well as 90-day and 1-year mortality. BCIS was observed in 51 cases (18%), defined as Grade 1 (O2% < 94% or fall in systolic
Purpose. The purposes of this study are as follows; 1) to compare postoperative blood loss between general anesthesia(GA) and spinal anesthesia(SA) and 2) to analyze the affecting factors of postoperative blood loss through the subgroup analysis. METHODS. A retrospective analysis was made on the clinical data of 122 patients with osteoarthritis undergoing primary TKA between January 2012 and December 2013. According to different anesthetic method, the patients were divided into the General Anesthesia group (73 cases) and the Spinal Anesthesia group (49 cases). Each group was divided subgroup as age, BMI, Preoperative
Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial
Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial
Despite advances in treating acute spinal cord injury (SCI), measures to mitigate permanent neurological deficits in affected patients are limited. Augmentation of mean arterial
Tourniquet use in total knee arthroplasty (TKA) remains a subject of considerable debate. A recent study questioned the need for tourniquets based on associated risks. However, the study omitted analysis of crucial tourniquet-related parameters which have been demonstrated in numerous studies to be associated with safe tourniquet use and reduction of adverse events. The current utilization and preferences of tourniquet use in Canada remain unknown. Our primary aim was to determine the current practices, patterns of use, and opinions of tourniquet use in TKA among members of the Canadian Arthroplasty Society (CAS). Additionally, we sought to determine the need for updated best practice guidelines to inform optimal tourniquet use and to identify areas requiring further research. A self-administered survey was emailed to members of the CAS in October 2021(six-week period). The response rate was 57% (91/161). Skip logic branching was used to administer a maximum of 59 questions related to tourniquet use, beliefs, and practices. All respondents were staff surgeons and 88% were arthroplasty fellowship trained. Sixty-five percent have been in practice for ≥11 years and only 16% for 50 TKA/year, 59% have an academic practice, and >67% prefer cemented TKA. Sixty-six percent currently use tourniquets, 25% no longer do but previously did, and 9% never used tourniquets. For those not using tourniquets, the most common reasons are potential harm/risks and publications/conferences. Among current users, 48% use in all cases and an additional 37% use in 76-99% of cases. The top reason for use was improved visualization/bloodless field (88%), followed by performing a cemented TKA, used in training, and faster operative times. The main patient factor influencing selective tourniquet use was peripheral vascular disease and main surgical factors were operative duration and cementless TKA. The most frequent adverse events reported were bruising/pinching under the tourniquet and short-term pain, which majority believed were related to improper tourniquet use (prolonged time, high-pressures, poor cuff fit), yet only 8% use contoured tourniquets and 32% don't use limb protection. Despite substantial evidence in literature that tourniquet safety and probability of harm are affected by tourniquet time and pressure, only 83% and 72% of respondents believe reducing tourniquet time and pressure respectively reduce the probability of harm. In addition, no surgeon utilizes personalized limb occlusion pressure which has been demonstrated to substantially reduce tourniquet pressure while being safe and effective. Furthermore, 62% always use fixed pressure and 37% will modify the pressure based on patient parameters, most often systolic
Aims. Tranexamic acid (TXA) has been shown to reduce blood loss and transfusion requirements in patients undergoing orthopaedic surgery. There remains a lack of prospective evidence for the use of TXA in patients undergoing periacetabular osteotomy (PAO). The purpose of this study was to determine if intravenous (IV) TXA is effective in reducing calculated blood loss and transfusions after PAO. Methods. This was a single-centre prospective double-blind placebo-controlled randomized trial of 81 patients aged 12 to 45 years undergoing elective PAO by a single surgeon. The intervention group (n = 40) received two doses of IV TXA of a maximum 1 g in each dose; the control group (n = 41) received two doses of 50 ml 0.9% saline IV. The primary outcome was perioperative calculated blood loss. Secondary outcomes included allogenic transfusions and six-week postoperative complications. Results. There were no differences in demographics or intraoperative variables between study groups. The TXA group demonstrated lower mean calculated blood loss (1,265 ml, (SD 321) vs 1,515 ml, (SD 394); p = 0.002) and lower frequency of allogenic transfusion (10%/n = 4 vs 37%/n = 15; p = 0.008). Regression analyses associated TXA use with significant reductions in calculated blood loss (p < 0.001) and transfusion (p = 0.007) after adjusting for age, sex, body mass index, preoperative haemoglobin, cell-saver volume, intraoperative mean arterial
The circulatory effects of multilevel balloon kyphoplasty (BK) are not adequately addressed, neither the effectiveness of egg shell cementoplasty in preventing anticipated cement leakage in difficult cases. The purpose of this study was to evaluate. the effect of multilevel BK to
Background. Aseptic loosening of cemented femoral stems results from migration of wear particles along the bone-cement interface, producing a foreign body reaction. After cement insertion,
Introduction: Compartment syndrome is one of the most devastating complications in orthopaedic trauma cases. The aim of this study is to investigate whether the intra-compartmental pressure changes rise and stay above the dangerous limits during percutaneous bridge plating of tibial shaft fractures necessitating fascial release or not. Patients and Methods: Between January 2007 and April 2009 17 isolated tibial fractures of the 17 patients were treated with percutaneous bridge plating technique by a single orthopaedic trauma surgeon. During the operation before, during and after the plating leg compartmental pressures were measured by using invasive
The pathogenesis of Perthes' disease has been related to increased intra-articular pressure secondary to a joint effusion. The pressure within the hip in different positions was measured in eight children with transient synovitis and four with the synovial stage of Perthes' disease. In the position of comfort for the hip this pressure was always less than the arteriolar
Objective: To assess the impact of EPP on physiological parameters in hemodynamically unstable patients with blunt pelvic trauma. Methods: Of 661 patients treated for pelvic trauma, 18 consecutive patients in shock underwent EPP with the intent to control massive pelvic bleeding. These patients constituted the study population. Data collected from the medical records and the Ullev̊l Trauma Registry included: demographics, fracture classification, additional injuries, blood transfusions, surgical interventions, angiographic procedure, physiological parameters and outcome. An association between continuous variables was calculated using the Spearman correlation coefficient. A comparison between means was calculated using the t-test. Results: Mean patient age was 44 years (range 16–80). ISS 47 (9–66). 39 % had non-measurable