Advertisement for orthosearch.org.uk
Results 1 - 20 of 106
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 73 - 73
11 Apr 2023
Nüesch A Kanelis E Alexopoulos L Williams F Geris L Gantenbein B Lacey M Le Maitre C
Full Access

A key cause of low back pain is the degeneration of the intervertebral disc (IVD). Causality between infection of the IVD and its degenerative process gained great interest over the last decade. Granville Smith et al. (2021) identified 36 articles from 34 research studies investigating bacteria in human IVDs. Bacteria was identified in 27 studies, whereas 9 attributed bacterial presence to contamination. Cutibacterium acnes was the most abundant, followed by coagulase-negative staphylococcus. However, whether bacteria identified were present in vivo or represent perioperative contamination remains unclear. This study investigated whether bacteria are present in IVDs and what potential effects they may have on native disc cells. Immunohistochemical staining for Gram positive bacteria was performed on human IVD tissue to identify presence and characterise bacterial species. Nucleus pulposus (NP) cells in monolayer and 3D alginate were stimulated with LPS and Peptidoglycan (0.1-50 µg/ml) for 48hrs. Following stimulation qPCR for factors associated with disc degeneration including matrix genes, matrix degrading enzymes, cytokines, neurotrophic factors and angiogenic factors and conditioned media collected for ELISA and luminex analysis. Gram positive bacteria was detected within human IVD tissue. Internalisation of bacteria by NP cells influenced the cell and nuclei morphology. Preliminary results of exposure of NP cells to bacterial components indicate that LPS as well as Peptidoglycan increase IL-8 and ADAMTS-4 gene expression following 48 hours of stimulation with a dose response seen for IL-8 induction by peptidoglycan compared to the control group. Underlining these results, IL-8 protein release was increased for treated groups compared to non-treated control. Further analysis is underway investigating other output measures and additional biological repeats. This study has demonstrated bacteria are present within IVD cells within IVD tissue removed from degenerate IVD and is determining the potential influence of these on disc degeneration


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 17 - 17
2 Jan 2024
Wildemann B
Full Access

The Global Burden of Disease Study 2019 showed a 33.4% increase in fractures and a 65.3% increase in Years lived with disability (YLD) since 1990. Although the overall rate of fracture related infection (FRI) is low, it increases to 30% in complex fractures. In addition, the implantation of foreign materials, such as fracture stabilizing implants, decreases the number of bacteria needed to cause an infection. Then, when infections do occur, they are difficult to treat and often require multiple surgeries to heal. The bacteria can persist in the canaliculi of the bony tissue, in cells, in a biofilm on material or necrotic bone or in abscess communities. In the last decades, different approaches have been pursued to modify biomaterials as well as implant surface and to develop antimicrobial surfaces or local drug release strategies. This talk will give an introduction to the problem of bony and implant associated infections and presents the development and preclinical (as well as clinical) studies of two approaches for local drug delivery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 18 - 18
2 Jan 2024
Ghezzi D Sartori M Boi M Montesissa M Sassoni E Fini M Baldini N Cappelletti M Graziani G
Full Access

Prosthetic joint infections represent complications connected to the implantation of biomedical devices, they have high incidence, interfere with osseointegration, and lead to a high societal burden. The microbial biofilm, which is a complex structure of microbial cells firmly attached to a surface, is one of the main issues causing infections. Biofilm- forming bacteria are acquiring more and more resistances to common clinical treatments due to the abuse of antibiotics administration. Therefore, there is increasing need to develop alternative methods exerting antibacterial activities against multidrug-resistant biofilm-forming bacteria. In this context, metal-based coatings with antimicrobial activities have been investigated and are currently used in the clinical practice. However, traditional coatings exhibit some drawbacks related to the insufficient adhesion to the substrate, scarce uniformity and scarce control over the toxic metal release reducing their efficacy. Here, we propose the use of antimicrobial silver-based nanostructured thin films to discourage bacterial infections. Coatings are obtained by Ionized Jet Deposition, a plasma-assisted technique that permits to manufacture films of submicrometric thickness having a nanostructured surface texture, allow tuning silver release, and avoid delamination. To mitigate interference with osseointegration, here silver composites with bone apatite and hydroxyapatite were explored. The antibacterial efficacy of silver films was tested in vitro against gram- positive and gram-negative species to determine the optimal coatings characteristics by assessing reduction of bacterial viability, adhesion to substrate, and biofilm formation. Efficacy was tested in an in vivo rabbit model, using a multidrug-resistant strain of Staphylococcus aureus showing significant reduction of the bacterial load on the silver prosthesis both when coated with the metal only (>99% reduction) and when in combination with bone apatite (>86% reduction). These studies indicate that IJD films are highly tunable and can be a promising route to overcome the main challenges in orthopedic prostheses


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 60 - 60
1 Apr 2018
Romera D Conde A Arenas MA De-Damborenea JJ Esteban J Aguilera-Correa JJ
Full Access

In the past decades, titanium-based biomaterials have been broadly used in maxillofacial and periodontology surgery. The main aetiological agents related to complications in this procedures are Porphyromonas gingivalis, a Gram-negative anaerobic bacteria that is also responsible for the development of chronic gingivitis, and Streptococcus oralis, a Gram positive facultative anaerobic bacteria. In previous studies, we have demonstrated that the fluorine doping of titanium-based alloys reduces bacterial adherence. The aim of this study is to evaluate the bacterial adherence on fluorine-doped titanium (TiF) probes compared to chemical polishing titanium (Ti) probes. The P. gingivalis ATCC 33277 and S. oralis ATCC 9811 adherence study was performed by introducing each probe in a well of 6-well plate with 5 ml containing 106 colony forming units (CFU/ml) in sterile 0.9% NaCl and was incubated 37°C 5% CO2 for 90 minutes, in anaerobiosis in the case of P. gingivalis. After incubation, samples were stained with LIVE/DEAD BacLight Bacterial Viability Kit. Proportion of live and dead bacteria was calculated and studied by using ImageJ software. The experiments were performed in triplicate. The statistical data were analyzed by nonparametric Wilcoxon test with a level of statistical significance of 0.05. Our results showed a significant (p<0.0053) 14.41% decrease of the adherence of P. gingivalis on TiF and an increase of 30% of dead cells. For S. oralis we did not get significant results. In conclusion, TiF can be considered a promising approach to prevent and treat infections related to maxillofacial and periodontology surgery


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 59 - 59
1 Apr 2018
Aguilera-Correa JJ Conde A Arenas MA De-Damborenea JJ Marin M Esteban J
Full Access

Prosthetic joint infections (PJI) occur infrequently, but they represent the most devastating complication with high morbidity and substantial cost. Staphylococcus aureus and coagulase-negative S. epidermidis are the most commonly infecting agents associated with PJI. Nowadays, Gram-negative species like Escherichia coli and Pseudomonas aeruginosa are gaining relevance. The use of TiO2 conical nanotubular doped with fluorine and phosphorous (FP-cNT) surfaces is an interesting approach to prevent surface bacterial colonization during surgery and favouring the osseointegration. Despite of there are serum markers related with PJI, to date there is described no biomaterial-related marker that allows detecting PJI. Here we describe the adherence and the bactericidal effect of FP-cNT and its capacity of marking the non-fermenting bacteria that have been in contact with it by Al. This metal is delivered by FP-cNT in non-toxic concentrations (between 25 and 29 ng/mL). F-P-cNT layers on Ti6Al4V alloy were produced as described previously by our group. Ti6Al4V chemical polishing (CP) samples without nanostructure were used as control and produced as described previously. S. aureus 15981, S. epidermidis ATCC 35984, E. coli ATCC 25922, and P. aeruginosa ATCC 27853 strains adherence study was performed using the protocol described by Kinnari et al. in 0.9% NaCl sterile saline with a 120 min incubation. After incubation, the samples were stained with LIVE/DEAD BacLight Bacterial Viability Kit. Proportion of live and dead bacteria was calculated and studied by using ImageJ software. The experiments were performed in triplicate. The aluminum concentration was estimated in the supernatant after incubation and in the 0.22 µm filtered supernatant by atomic absorption in graphite furnace. The statistical data were analyzed by nonparametric Kruskal-Walis test and by pairwise comparisons using the nonparametric unilateral Wilcoxon test with a level of statistical significance of p<0.05. The values are cited as medians. Our results show that the bacterial adherence of all tested species significantly decreased on FP-cNT compared to CP except P. aeruginosa ATCC 27853: 19.8% for S. aureus 15981, 45.3% for S. epidermidis ATCC 35984 and 8.1% for E. coli ATCC 25922. The bacterial viability decreased 2-fold for S. aureus 15981, and 5-fold for S. epidemidis ATCC 35984, but increased 95% for P. aeruginosa ATCC 27853 and there no was variation for E. coli ATCC 25922 on FP-cNT compared to CP. Only supernatant P. aeruginosa ATCC 27853 shows significant Al detection after 120 min incubation (p<0.05). In summary, F-P cNT is a promising biomaterial that besides favoring osseointegration and potential usefulness as drug carrier, present bactericidal, non-stick ability (at least for staphylococci and E. coli) and is able to mark P. aeruginosa with Al, which could be potentially monitored in serum and urine in patients with PJI


Bone & Joint Research
Vol. 6, Issue 5 | Pages 323 - 330
1 May 2017
Pijls BG Sanders IMJG Kuijper EJ Nelissen RGHH

Objectives. Infection of implants is a major problem in elective and trauma surgery. Heating is an effective way to reduce the bacterial load in food preparation, and studies on hyperthermia treatment for cancer have shown that it is possible to heat metal objects with pulsed electromagnetic fields selectively (PEMF), also known as induction heating. We therefore set out to answer the following research question: is non-contact induction heating of metallic implants effective in reducing bacterial load in vitro?. Methods. Titanium alloy cylinders (Ti6Al4V) were exposed to PEMF from an induction heater with maximum 2000 watts at 27 kHz after being contaminated with five different types of micro-organisms: Staphylococcus epidermidis; Staphylococcus aureus; Pseudomonas aeruginosa; spore-forming Bacillus cereus; and yeast Candida albicans. The cylinders were exposed to incremental target temperatures (35°C, 45°C, 50°C, 55°C, 60°C, 65°C, 70°C) for up to 3.5 minutes. Results. There was an average linear heating rate of 0.39°C per second up to the target temperature, and thereafter the target temperature was maintained until the end of the experiment. At 60°C and higher (duration 3.5 minutes), there was a 6-log reduction or higher for every micro-organism tested. At 60°C, we found that the shortest duration of effective induction heating was 1.5 minutes. This resulted in a 5-log reduction or higher for every micro-organism tested. Conclusion. Non-contact induction heating of a titanium disk is effective in reducing bacterial load in vitro. These promising results can be further explored as a new treatment modality for infections of metal orthopaedic implants. Cite this article: B. G. Pijls, I. M. J. G. Sanders, E. J. Kuijper, R. G. H. H. Nelissen. Non-contact electromagnetic induction heating for eradicating bacteria and yeasts on biomaterials and possible relevance to orthopaedic implant infections: In vitro findings. Bone Joint Res 2017;6:323–330. DOI: 10.1302/2046-3758.65.BJR-2016-0308.R1


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 85 - 85
4 Apr 2023
Wulfhorst M Büssemaker H Meinshausen A Herbster M Döring J Mai V Lohmann C Kautz A Laube T Wyrwa R Schnabelrauch M Bertrand J
Full Access

The implantation of endoprosthesis is a routine procedure in orthopaedics. Endoprosthesis are mainly manufactured from ceramics, polymers, metals or metal alloys. To ensure longevity of the implants they should be as biocompatible as possible and ideally have antibacterial properties, to avoid periprosthetic joint infections (PJI). Various antibacterial implant materials have been proposed, but have so far only been used sporadically in patients. PJI is one of the main risk factors for revision surgeries. The aim of the study was to identify novel implant coatings that both exhibit antibacterial properties whilst having optimal biocompatibility.

Six different novel implant coatings and surface modifications (EBM TiAl6V4, strontium, TiCuN, TiNbN, gentamicin phosphate (GP), gentamicin phosphate+cationic polymer (GP+CP)) were compared to standard CoCrMo-alloy. The coatings were further characterized with regard to the surface roughness. E. coli and S. capitis were cultured on the modified surfaces to investigate the antibacterial properties. To quantify bacterial proliferation the optical density (OD) was measured and viability was determined using colony forming units (CFU). Murine bone marrow derived macrophages (BMMs) were cultured on the surfaces and differentiated into osteoblasts to quantify the mineralisation using the alizarin red assay.

All novel coatings showed reduced bacterial proliferation and viability compared to standard CoCrMo-alloy. A significant reduction was observed for GP and GP+CP coated samples compared to CoCrMo (ODGP,E.coli = 0.18±0.4; ODGP+CP,E.coli = 0.13±0.3; p≤0.0002; N≥7-8). An increase in osteoblast-mediated mineralisation was observed on all surfaces tested compared to CoCrMo. Furthermore, GP and GP+CP coated samples showed a statistically significant increase (MGP = 0.21±0.1; MGP+CP = 0.25±0.2; p<0.0001; N≥3-6).

The preliminary data indicates that the gentamicin containing surfaces have the most effective antibacterial property and the highest osseointegrative capacity. The use of antibiotic coatings on prostheses could reduce the risk of PJI while being applied on osseointegrative implant surfaces.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 49 - 49
1 May 2012
McLaren J Shakesheff K Quirk R Goodship A Bayston R Scammell B
Full Access

Introduction. Open fractures occur with an annual incidence of 11.5 per 100,000 (6900 pa in UK). Infection rates, even with intravenous broad-spectrum antibiotics, remain as high as 22%. For this reason necessary bone grafting is usually delayed until soft-tissue cover of the bone injury is achieved. A biodegradable bone graft that released sustained high concentrations of antibiotics and encouraged osteogenesis, that could be implanted safely on the day of injury would reduce infection rates and avoid reoperation and secondary grafting. The non –union rate (approx 350 pa in UK) should also be reduced. Such a graft, consisting of a PLA/PGA co –polymer and containing antibiotics, is under development and here we report assessment of spectrum and duration of antimicrobial activity and effect of addition of antibiotics on mechanical properties. Methods. Varying concentrations of gentamicin, colistin, clindamycin and trimethoprim, singly and in combination, were added to the copolymer and test pieces were made. These were then tested using an established method (SPTT) which determines degree and duration of antimicrobial activity as well as risk of emerging resistance. Test bacteria were Staphylococcus epidermidis, Staphylococcus aureus, MRSA and Escherichia coli. Mechanical properties (compressive strength and porosity) were determined using established methods. Results. A combination of gentamicin (4%w/w) and clindamycin (2.5% w/w) gave best results, with inhibitory activity persisting for over 21 days (the target duration) without emergence of resistance. No significant effect of this combination/concentration on mechanical properties was found. Conclusions. The experimental PLA/PGA scaffold containing antibiotics showed activity against the common pathogens of open fractures for a period considered long enough to eradicate contamination acquired at or soon after trauma. At the optimum concentration, they had no significant effect on mechanical properties. In vivo performance is currently being investigated in a sheep model


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 97 - 97
1 Nov 2018
Greenfield E
Full Access

Considerable evidence exists that aseptic loosening is initiated by wear particles that recruit macrophages and stimulate their production of pro-inflammatory cytokines. The cytokines primarily act indirectly by inducing production of RANKL, which stimulates osteoclast differentiation, osteolysis, and inflammatory bone loss. There is also considerable evidence that activation of macrophage Toll-like Receptors (TLRs) contributes to this cascade of events. It is however controversial whether bacterially-derived immunostimulatory molecules known as Pathogen-Associated Molecular Patterns (PAMPs) can contribute to aseptic loosening by stimulating their cognate TLRs on macrophages. Priming and subsequent activation of the NLRP3 inflammasome is essential for macrophage production of mature, active IL-1β in response to wear particles. We recently confirmed that wear particles can activate pre primed NLRP3 inflammasomes in the absence of PAMPs. Thus, activation of the NLRP3 inflammasome is the only macrophage-based event in the aseptic loosening cascade that we have found to date is independent of PAMPs. In contrast, priming of the NLRP3 inflammasome by wear particles requires PAMPs as well as their cognate TLRs. These results add to the growing body of evidence that bacterially-derived PAMPs can contribute to aseptic loosening.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 43 - 43
17 Nov 2023
Wilkinson H Cool P
Full Access

Abstract. Objectives. The objective of this study is to investigate if genomic sequencing is a useful method to diagnose orthopaedic infections. Current methods used to identify the species of bacteria causing orthopaedic infections take considerable time and the results are frequently insufficient for guiding antibiotic treatment. The aim here is to investigate if genomic sequencing is a faster and more reliable method to identify the species of bacteria causing infections. Current methods include a combination of biochemical markers and microbiological cultures which frequently produce false positive results and false negative results. Methods. Samples of prosthetic fluid were obtained from surgical interventions to treat orthopaedic infections. DNA is extracted from these samples lab and nanopore genomic sequencing is performed. Initial investigations informed that a sequencing time of 15 minutes was sufficient. The resulting genomic sequence data was classified using Basic Local Alignment Tool (BLAST) against the NCBI bacterial database and filtered by only including reads with an identity score of 90 and E-value of 1e-50. An E-value of 1e-50 suggests a high-quality result and is commonly used when analysing genomic data. This data was then filtered in R Studio to identify if any species were associated with orthopaedic infections. The results from genomic sequencing were compared to microbiology results from the hospital to see if the same species had been identified. The whole process from DNA extraction to output took approximately 2 hours, which was faster than parallel microbiological cultures. Results. In these preliminary analyses, 15 samples have been collected from patients with confirmed/suspected orthopaedic infections. To date, 11 samples from confirmed infected patients have been sequenced and a summary of the findings are presented in the table attached. As well as finding bacteria species to match microbiological cultures, genomic sequencing has also identified bacteria when culture results have been negative, but the patient is known to have an infection due to clinical indication and previous culture results. This example suggests genomic sequencing may have higher sensitivity than microbiological cultures at detecting bacteria causing orthopaedic infections. Results in table indicate the identification of bacteria from genomic sequencing that match microbiological cultures are high quality. Conclusions. Preliminary data presented using genomic sequencing suggests that the technique may be useful to identify bacterial species causing orthopaedic infections and can do so in a shorter time frame than current microbial methods. The results from genomic sequencing all produced a number of false positive results which hopefully can be reduced by improving the bioinformatic techniques used and increasing the sample number to include individuals without an infection. Further analysis will also look at identifying antibiotic resistance genes in the sequencing data and seeing if this ca be used to predict which patients will and will not respond to antibiotic treatment. The aim at the end of this project is to demonstrate if genomic sequencing is a more sensitive method to identify bacteria causing orthopaedic infections that current methods and if it can be used to guide antibiotic treatment. Include limitations, next steps and bigger picture. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 138 - 138
4 Apr 2023
Markel D Dietz P Wu B Bou-Akl T Ren W
Full Access

The efficacy of saline irrigation for the treatment of periprosthetic infection (PJI) is limited in the presence of infected implants. This study evaluated the efficacy of vancomycin/tobramycin-doped polyvinyl alcohol (PVA)/ceramic composites (PVA-VAN/TOB-P) after saline irrigation in a mouse pouch infection model. 3D printed porous titanium (Ti) cylinders (400, 700 and 100 µm in pore size) were implanted into mice pouches, then inoculated with S. aureus at the amounts of 1X10. 3. CFU and 1X10. 6. CFU per pouch, respectively. Mice were randomized into 4 groups (n=6 for each group): (1) no bacteria; (2) bacteria without saline wash; 3) saline wash only, and (4) saline wash+PVA-VAN/TOB-P. After seven days, pouches were washed out alone or with additional injection of 0.2 ml of PVA-VAN/TOB-P. Mice were sacrificed 14 days after pouch wash. Bacteria cultures of collected Ti cylinders and washout fluid and histology of pouch tissues were performed. The low-grade infection (1X10. 3. CFU) was more significant in 400 µm Ti cylinders than that in Ti cylinders with larger pore sizes (700 and 1000 µm (p<0.05). A similar pattern of high-grade infection (1X10. 6. CFU) was observed (p<0.05). For the end wash, the bacteria burden (0.49±0.02) in saline wash group was completely eradicated by the addition of PVA-VAN/TOB-P (0.005±0.001, p<0.05). We noticed that 400 µm Ti cylinders have the highest risk of implant infection. Our data supported that the effect of saline irrigation was very limited in the presence of contaminated porous Ti cylinders. PVA-VAN/TOB-P was biodegradable, biocompatible, and was effective in eradicating bacteria retention after saline irrigation in a mouse model of low grade and high-grade infection. We believe that PVA-VAN/TOB-P represents an alternative to reduce the risk of PJI by providing a sustained local delivery of antibiotics


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 40 - 40
14 Nov 2024
Siverino C Sun Q Yang D Solomon B Moriarty F Atkins G
Full Access

Introduction. Bone and joint infection (BJI) is often characterized by severe inflammation and progressive bone destruction. Osteocytes are the most numerous and long-lived bone cell type, and therefore represent a potentially important long-term reservoir of bacterial infection. Staphylococcus aureus is known to establish stable intracellular osteocytic infections, however, little is known about the less virulent yet second most prevalent BJI pathogen, S. epidermidis, associated with late-diagnosed, chronic BJI. Thus, this study sought to establish an in vitro model to study the infection characteristics of S. epidermidis in human osteocyte-like cells. Methods. SaOS2 cells (1 ×10. 4. cells/cm. 2. ) were grown to confluence either without differentiation, representing an osteoblast-like (OB) state (SaOS2-OB) or differentiated to an osteocyte-like stage (SaOS2-OY), using established methods. Four S. epidermidis strains used (ATCC-12228, ATCC-14990, ATCC-35984 and a clinical osteomyelitis strain RAH-SE1) were tested to be Lysostaphin-resistant, necessitating antibiotic (Levofloxacin) control of extracellular bacteria. Infection of host cells (OB or OY) was tested at three multiplicities of infection (MOI: 10, 100 and 1000). Extracellular bacteria were controlled by overnight incubation at a 10X minimum inhibitory concentration (MIC) of Levofloxacin and thereafter at 1XMIC. At each time point (days 1, 3, 5) viable intra- and extracellular bacteria were quantified. Result. All strains displayed similar intracellular infection and persistence capabilities in SaOS2-OB and SaOS2-OY. Independent of MOI, intracellular bacteria in SaOS2-OB decreased over time, becoming non-culturable by day 5. In contrast, SaOs2-OY displayed enhanced intracellular bacterial persistence at each time point. In the presence of increased Levofloxacin concentration (10XMIC), S. epidermidis could persist intracellularly for at least 14 days. Conclusion. This study showed for the first time that S. epidermidis can infect human osteocytes and persist intracellularly. Additionally, even a 10xMIC antibiotic concentration failed to eradicate intracellular bacteria, suggesting that persistence within osteocytes could contribute to treatment failure and establishment of chronic BJI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 21 - 21
4 Apr 2023
Meinshausen A Büssemaker H Viet Duc B Döring J Voropai V Müller A Martin A Berger T Schubert A Bertrand J
Full Access

Periprosthetic joint infections (PJI) are one of the most common reasons for orthopedic revision surgeries. In previous studies, it has been shown that silver modification of titanium (Ti-6Al-4V) surfaces by PMEDM (powder mixed electrical discharge machining) has an antibacterial effect on Staphylococcus aureus adhesion. Whether this method also influences the proliferation of bacteria has not been investigated so far. Furthermore, the effect is only limitedly investigated on the ossification processes. Therefore, the aim of this work is to investigate the antibacterial effect as well as the in vitro ossification process of PMEDM machined surfaces modified by integration of silver. In this study, we analyzed adhesion and proliferation of S. aureus in comparison to of surface roughness, silver content and layer thickness of the silver-integrated-PMEDM surfaces (N = 5). To test the in vitro ossification, human osteoblasts (SaOs-2) and osteoclasts (differentiated from murine-bone-marrow-macrophages) were cultured on the silver surfaces (N = 3). We showed that the attachment of S. aureus on the surfaces was significantly lower than on the comparative control surfaces of pure Ti-6Al-4V without incorporated silver, independently of the measured surface properties. Bacterial proliferation, however, was not affected by the silver content. No influence on the in vitro ossification was observed, whereas osteoclast formation was drastically reduced on the silver-modified surfaces. We showed that 1 to 3% of silver in the surface layer significantly reduced the adhesion of S. aureus, but not the proliferation of already attached bacteria. At the same time, no influence on the in vitro ossification was observed, while no osteoclasts were formed on the surface. Therefore, we state that PMEDM with simultaneous silver modification of the machined surfaces represents a promising technology for endoprostheses manufacturing to reduce infections while at the same time optimizing bone ingrowth


Prosthetic joint infection (PJI) is a serious complication following joint replacement. Antiseptic solutions are often used for intraoperative wound irrigation particularly in cases of revision for PJI. Antiseptic irrigation is intended to eradicate residual bacteria which may be either free floating or in residual biofilm although there is no clear clinical efficacy for its use. Also, reviewing the scientific literature there is discordance in in vitro results where some studies questions antiseptic efficacy whilst others suggest that even at low concentration antiseptic agents are effective at eradicating bacterial biofilms. The aim of this in vitro study was to establish the efficacy of undiluted antiseptic agents at eradication of a typical PJI forming biofilm and determine the importance of an antiseptic neutralisation step in this assessment. Mature Staphylococcus epidermidis biofilms grown on TiAl6V4 discs were submerged in chlorohexidine (CHL) gluconate 4%, povidone-iodine (PI) 10% or phosphate-buffered saline (PBS) control solution. The discs were then rinsed, the biofilm bacteria suspended in solution using sonication and vortexing, and the viable count (CFU/ml) of the bacterial suspensions determined. The rinse/suspension solution was either (a) PBS or (b) Dey-Engley neutralization broth (NB). When PBS was used to rinse/suspend the biofilm a highly significant, 7.5 and 4.1, mean log reduction in biofilm vitality was observed from the control, for CHL 4% and PI 10%, respectively. However, when NB was the rinse/suspension solution the apparent antiseptic biofilm eradication efficacy was replaced with a statistically significant but clinically irrelevant less the one log-reduction in biofilm vitality. Clinical antiseptic agents are ineffective at eradicating S. epidermidis biofilm in an in vitro PJI model and absence of a neutralisation step gives the false impression of efficacy. Antiseptics alone are an ineffective treatment for biofilm related PJI and no substitute for meticulous debridement


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 134 - 134
2 Jan 2024
Ghezzi D Sartori M Boi M Montesissa M Sassoni E Fini M Baldini N Cappelletti M Graziani G
Full Access

Prosthetic joint infections represent complications connected to the implantation of biomedical devices, they have high incidence, interfere with osseointegration, and lead to a high societal burden. The microbial biofilm, which is a complex structure of microbial cells firmly attached to a surface, is one of the main issues causing infections. Biofilm- forming bacteria are acquiring more and more resistances to common clinical treatments due to the abuse of antibiotics administration. Therefore, there is increasing need to develop alternative methods exerting antibacterial activities against multidrug-resistant biofilm-forming bacteria. In this context, metal-based coatings with antimicrobial activities have been investigated and are currently used in the clinical practice. However, traditional coatings exhibit some drawbacks related to the insufficient adhesion to the substrate, scarce uniformity and scarce control over the toxic metal release reducing their efficacy. Here, we propose the use of antimicrobial silver-based nanostructured thin films to discourage bacterial infections. Coatings are obtained by Ionized Jet Deposition, a plasma-assisted technique that permits to manufacture films of submicrometric thickness having a nanostructured surface texture, allow tuning silver release, and avoid delamination. To mitigate interference with osseointegration, here silver composites with bone apatite and hydroxyapatite were explored. The antibacterial efficacy of silver films was tested in vitro against gram- positive and gram-negative species to determine the optimal coatings characteristics by assessing reduction of bacterial viability, adhesion to substrate, and biofilm formation. Efficacy was tested in an in vivo rabbit model, using a multidrug-resistant strain of Staphylococcus aureus showing significant reduction of the bacterial load on the silver prosthesis both when coated with the metal only (>99% reduction) and when in combination with bone apatite (>86% reduction). These studies indicate that IJD films are highly tunable and can be a promising route to overcome the main challenges in orthopedic prostheses


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 106 - 106
11 Apr 2023
McIff T Funk G Horn E Hageman K Varner A Kilway K
Full Access

We developed a novel silorane-based biomaterial (SBB) for use as an orthopedic cement. SBB is comprised of non-toxic silicon-based monomers, undergoes non-exothermic polymerization, and has weight-bearing strength required of orthopedic cements. We sought to compare the antibiotic release kinetics of this new cement to that of commercially available PMMA bone cement. We also evaluated each material's inherent propensity to support the attachment of bacteria under both static and dynamic conditions. One gram of either rifampin or vancomycin was added to 40g batches of PMMA and SBB. Pellets were individually soaked in PBS. Eluate was collected and tested daily for 14 days using HPLC. Compressive strength and modulus were tested over 21 days. Bioassays were used to confirm the bioactivity of the antibiotics eluted. We measured the growth and maturation of staphylococcus aureus (SA) biofilm on the surface of both PMMA and SBB disks over the course of 72 hours in a static well plate and in a dynamic biofilm reactor (CDC Biofilm Reactor). N=4 at 24, 48, and 72 hours. A luminescent strain of SA (Xen 29) was employed allowing imaging of bacteria on the discs. SBB eluted higher concentrations of vancomycin than did PMMA over the course of 14 days (p<0.001). A significant 55.1% greater day 1 elution was observed from SBB. Silorane cement was able to deliver rifampin in clinically favorable concentrations over 14 days. On the contrary, PMMA was unable to deliver rifampin past day 1. The incorporation of rifampin into PMMA severely reduced its mechanical strength (p<0.001) and modulus (p<0.001). Surface bacterial radiance of PMMA specimens was significantly greater than that of SBB specimens at all time points (p<0.05). The novel silorane-based cement demonstrated superior antibiotic release and, even without antibiotic incorporation, demonstrated an innate inhabitation to bacterial attachment and biofilm


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 66 - 66
11 Apr 2023
Sebastian S Collin M Liu Y Raina D Tägil M Lidgren L
Full Access

There is a lack of carriers for the local delivery of rifampicin (RIF), one of the cornerstone second defence antibiotic for Staphylococcus aureus deep bone infections (DBIs). RIF is also associated with systemic side effects, and known for causing rapid development of antibiotic resistance when given as monotherapy. We evaluated a clinically usedbi-phasic calcium sulphate/hydroxyapatite (CaS/HA) biomaterial as a carrier for dual delivery of RIF with vancomycin (VAN) or gentamicin (GEN). It was hypothesized that this combined approach could provide improved biofilm eradication and prevent the development of RIF resistance. Methods: 1) Biofilm eradication: Using a modified crystal violet staining biofilm quantification method, the antibiotics released at different time points (Day 1, 3, 7, 14, 21, 28 and 35) from the hemispherical pellets of CaS/HA(500 mg)-VAN (24.57 mg) / GEN (10.35 mg) composites with or without RIF (8.11 mg) were tested for their ability to disrupt the preformed 48-h old biofilms of S. aureus ATCC 25923, and S. aureus clinical strain P-3 in 96-well microtitre plate. For each tested group of antibiotic fractions, five separate wells were used (n=5). 2) Testing for resistance development: Similar to the method mentioned above the 48-h biofilm embeded bacteria exposed to antibiotic fractions from different time points continuously for 7 days. The biofilms remained were then tested for RIF resistant strains of bacteria. Overall, there was clear antibiofilm biofilm activity observed with CaS/HA-VAN/GEN+RIF combinations compared with CaS/HA-VAN/GEN alone. The S. aureus strains developed resistance to RIF when biofilms were subjected to CaS/HA-RIF alone but not with combinations of CaS/HA-VAN/GEN+RIF. Enhanced antibiofilm effects without development of RIF resistance indicates that biphasic CaS/HA loaded with VAN or GEN could be used as a carrier for RIF for additional local delivery in clinically demanding DBIs. Acknowledgement: We deeply acknowledge the Royal Fysiographic Society of Lund, Landshövding Per Westlings Minnesfond and the Stina and Gunnar Wiberg fond for financial support


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 144 - 144
4 Apr 2023
Markel D Chatterji R Bou-Akl T Wu B Dietz P Ren W
Full Access

Irrigation with antiseptic agents, antibiotics, and surfactants are used for treatment and prevention of infections. Despite desirable microbicidal actions, studies have demonstrated cytotoxic effects on host tissue that may impair healing. This study investigated the extent of tissue damage caused by commonly used irrigation solutions in the presence or absence of infection. Air pouches created in 60 balb/c mice were divided into two groups (n=30): infected with Staphylococcus aureus and control. One week later the infected group was subdivided into 5 subgroups (n=6) based on irrigation solutions and by day 0 (immediately) and day7 after irrigation (n=3). Solutions included Saline, Bacitracin, Clorpactin, Irrisept and Bactisure. In infected group wash fluid was collected for quantitative analysis of bacterial growth. At the specified times mice were sacrificed, pouch tissue sent for histology, and sections analyzed for inflammation, necrosis, and edema. Inflammation decreased in infected vs sterile pouches for all solutions except Bacitracin day 0 and for all solutions day 7 with significance in all except Bacitracin (p<0.05). On day 0, necrosis increased in infected vs sterile pouches in Bacitracin (p=0.006), Irrisept (p=0.18), or Bactisure (p=0.07); however, on day 7, necrosis significantly decreased in infected pouches for all solutions (p<0.05) except for Clorpactin (p=0.18). Edema decreased in infected vs sterile pouches on day 0 for all solutions with significance in saline, Irrisept, and Bacitracin (p<0.05). On day 7, infected pouches had decreased edema in saline, Bacitracin, and Bactisure (p<0.05) and increased in Irrisept (p<0.05) and Clorpactin (p=0.069) compared to sterile pouches. Bacterial culture of washouts demonstrated that Clorpactin, Irrisept and Bactisure controlled the infection, whereas saline and Bacitracin showed bacterial multiplication 3.9 × 10^7 CFU/ml and 6.7 × 10^7 CFU/ml respectively. Bacitracin wash showed significantly more bacteria growth compared to Clorpactin (p=0.024), Irrisept (p=0.025) and Bactisure (p=0.025). Tissue damage varied with irrigation solutions and the presence or absence of infection. Presence of bacteria appeared to lead to less tissue inflammation and edema. Tissue necrosis varied over time with different solutions. Surgeons must weigh risks and benefits when selecting solutions and determining when to irrigate


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 21 - 21
1 Dec 2022
Montesissa M Farè S Draghi L Rau J Gualandi C Focarete M Boi M Baldini N Graziani G
Full Access

Favoring osseointegration and avoiding bacterial contamination are the key challenges in the design of implantable devices for orthopedic applications. To meet these goals, a promising route is to tune the biointerface of the devices, that can regulate interactions with the host cells and bacteria, by using nanostructured antibacterial and bioactive coatings. Indeed, the selection of adequate metal-based coatings permits to discourage infection while avoiding the development of bacterial resistance and nanostructuring permits to tune the release of the antimicrobial compounds, allowing high efficacy and decreasing possible cytotoxic effects. In addition, metal-doped calcium phosphates-based nanostructured coatings permit to tune both composition and morphology of the biointerfaces, allowing to regulate host cells and bacteria response. To tune the biointerfaces of implantable devices, nanostructured coatings can be used, but their use is challenging when the substrate is heat-sensitive and/or porous. Here, we propose the use of Ionized Jet Deposition (IJD) to deposit metallic and ion-doped calcium phosphates materials onto different polymeric substrates, without heating and damaging the substrate morphology. 3D printed scaffolds in polylactic acid (PLA) and polyurethane (PU), and electrospun matrices in polycaprolactone (PCL) and PLA were used as substrates. Biogenic apatite (HA), ion doped (zinc, copper and iron) tricalcium phosphate (TCP) and silver (Ag) coatings were obtained on porous and custom-made polymeric substrates. Chemical analyses confirmed that coatings composition matches that of the target materials, both in terms of main phase (HA or TCP) and ion doping (presence of Cu, Zn or Fe ion). Deposition parameters, and especially its duration time, influence the coating features (morphology and thickness) and substrate damage. Indeed, SEM/EDS observations show the presence of nanostructured agglomerates on substrates surface. The dimensions of the aggregates and the thickness of the coating films increase increasing the deposition time, without affecting the substrate morphology (no porosity alteration or fibers damaging). The possible substrate damage is influenced by target and substrate material, but it can be avoided modulating deposition time. Once the parameters are optimized, the models show suitable in vitro biological efficacy for applications in bone models, regenerative medicine and infection. Indeed, HA-based coatings favor cells adhesion on printed and electrospun fibers. For antibacterial applications, the ion doped TCP coatings can reduce the bacterial growth and adhesion (E.coli and S.aureus) on electrospun matrices. To conclude, it is possible achieve different properties applying nanostructured coatings with IJD technique on polymeric substrates, modulating deposition conditions to avoid substrate damage


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 13 - 13
1 Nov 2021
Dubus M Rammal H Scomazzon L Baldit A Braux J Mauprivez C Kerdjoudj H
Full Access

Introduction and Objective. Alveolar bone resorption following tooth extraction or periodontal disease compromises the bone volume required to ensure the stability of an implant. Guided bone regeneration (GBR) is one of the most attractive technique for restoring oral bone defects, where an occlusive membrane is positioned over the bone graft material, providing space maintenance required to seclude soft tissue infiltration and to promote bone regeneration. However, bone regeneration is in many cases impeded by a lack of an adequate tissue vascularization and/or by bacterial contamination. Using simultaneous spray coating of interacting species (SSCIS) process, a bone inspired coating made of calcium phosphate-chitosan-hyaluronic acid was built on one side of a nanofibrous GBR collagen membrane in order to improve its biological properties. Materials and Methods. First, the physicochemical characterizations of the resulting hybrid coating were performed by scanning electron microscopy, X-ray photoelectron, infrared spectroscopies and high-resolution transmission electron microscopy. Then human mesenchymal stem cells (MSCs) and human monocytes were cultured on those membranes. Biocompatibility and bioactivity of the hybrid coated membrane were respectively evaluated through MSCs proliferation (WST-1 and DNA quantification) and visualization; and cytokine release by MSCs and monocytes (ELISA and endothelial cells recruitment). Antibacterial properties of the hybrid coating were then tested against S. aureus and P. aeruginosa, and through MSCs/bacteria interactions. Finally, a preclinical in vivo study was conducted on rat calvaria bone defect. The newly formed bone was characterized 8 weeks post implantation through μCT reconstructions, histological characterizations (Masson's Trichrome and Von Kossa stain), immunohistochemistry analysis and second harmonic generation. Biomechanical features of newly formed bone were determined. Results. The resulting hybrid coating of about 1 μm in thickness is composed of amorphous calcium phosphate and carbonated poorly crystalline hydroxyapatite, wrapped within chitosan/hyaluronic acid polysaccharide complex. Hybrid coated membrane possesses excellent bioactivity and capability of inducing an overwhelmingly positive response of MSCs and monocytes in favor of bone regeneration. Furthermore, the antibacterial experiments showed that the hybrid coating provides contact-killing properties by disturbing the cell wall integrity of Gram-positive and Gram-negative bacteria. Its combination with MSCs, able to release antibacterial agents and mediators of the innate immune response, constitutes an excellent strategy for fighting bacteria. A preclinical in vivo study was therefore conducted in rat calvaria bone defect. μCT reconstructions showed that hybrid coated membrane favored bone regeneration, as we observed a two-fold increase in bone volume / total volume ratios vs. uncoated membrane. The histological characterizations revealed the presence of mineralized collagen (Masson's Trichrome and Von Kossa stain), and immunohistochemistry analysis highlighted a bone vascularization at 8 weeks post-implantation. However, second harmonic generation analysis showed that the newly formed collagen was not fully organized. Despite a significant increase in the elastic modulus of the newly formed bone with hybrid coated membrane (vs. uncoated membrane), the obtained values were lower than those for native bone (approximately 3 times less). Conclusions. These significant data shed light on the regenerative potential of such bioinspired hybrid coating, providing a suitable environment for bone regeneration and vascularization, as well as an ideal strategy to prevent bone implant-associated infections