The surgical helmet system (SHS) was developed to reduce the risk of periprosthetic joint infection (PJI), but the evidence is contradictory, with some studies suggesting an increased risk of PJI due to potential leakage through the glove-gown interface (GGI) caused by its positive pressure. We assumed that SHS and glove exchange had an impact on the leakage via GGI. There were 404 arthroplasty simulations with fluorescent gel, in which SHS was used (H+) or not (H-), and GGI was sealed (S+) or not (S-), divided into four groups: H+S+, H+S-, H-S+, and H-S-, varying by exposure duration (15 to 60 minutes) and frequency of glove exchanges (0 to 6 times). The intensity of fluorescent leakage through GGI was quantified automatically with an image analysis software. The effect of the above factors on fluorescent leakage via GGI were compared and analyzed.Aims
Methods
Aims. The aim of this study was to estimate time to arthroplasty among patients with hip and knee osteoarthritis (OA), and to identify factors at enrolment to first-line intervention that are prognostic for progression to surgery. Methods. In this longitudinal register-based observational study, we identified 72,069 patients with hip and knee OA in the Better Management of Patients with Osteoarthritis Register (BOA), who were referred for first-line OA intervention, between May 2008 and December 2016. Patients were followed until the first primary
Extended patient waiting lists for assessment and treatment are widely reported for planned elective joint replacement surgery. The development of regionally based Elective Orthopaedic Centres, separate from units that provide acute, urgent or trauma care has been suggested as one solution to provide protected capacity and patient pathways. These centres will adopt protocolised care to allow high volume activity and increased day-case care. We report the plan to establish a new elective orthopaedic centre serving a population of 2.4 million people. A census conducted in 2022 identified that 15000 patients were awaiting joint replacement surgery with predictions for further increases in waiting times. The principle of care will be to offer routine primary
Aims. This study aimed to investigate the estimated change in primary and revision arthroplasty rate in the Netherlands and Denmark for hips, knees, and shoulders during the COVID-19 pandemic in 2020 (COVID-period). Additional points of focus included the comparison of patient characteristics and hospital type (2019 vs COVID-period), and the estimated loss of quality-adjusted life years (QALYs) and impact on waiting lists. Methods. All hip, knee, and shoulder arthroplasties (2014 to 2020) from the Dutch Arthroplasty Register, and hip and knee arthroplasties from the Danish Hip and Knee Arthroplasty Registries, were included. The expected number of arthroplasties per month in 2020 was estimated using Poisson regression, taking into account changes in age and sex distribution of the general Dutch/Danish population over time, calculating observed/expected (O/E) ratios. Country-specific proportions of patient characteristics and hospital type were calculated per indication category (osteoarthritis/other elective/acute). Waiting list outcomes including QALYs were estimated by modelling virtual waiting lists including 0%, 5% and 10% extra capacity. Results. During COVID-period, fewer arthroplasties were performed than expected (Netherlands: 20%; Denmark: 5%), with the lowest O/E in April. In the Netherlands, more acute indications were prioritized, resulting in more American Society of Anesthesiologists grade III to IV patients receiving surgery. In both countries, no other patient prioritization was present. Relatively more arthroplasties were performed in private hospitals. There were no clinically relevant differences in revision arthroplasties between pre-COVID and COVID-period. Estimated total health loss depending on extra capacity ranged from: 19,800 to 29,400 QALYs (Netherlands): 1,700 to 2,400 QALYs (Denmark). With no extra capacity it will take > 30 years to deplete the waiting lists. Conclusion. The COVID-19 pandemic had an enormous negative effect on arthroplasty rates, but more in the Netherlands than Denmark. In the Netherlands, hip and shoulder patients with acute indications were prioritized. Private hospitals filled in part of the capacity gap. QALY loss due to postponed
There is an increasing incidence of revision for periprosthetic joint infection. The addition of vancomycin to beta-lactam antimicrobial prophylaxis in joint arthroplasty may reduce surgical site infections, however, the efficacy and safety have not been established. This was a multicenter, double-blind, superiority, placebo-controlled trial. We randomized 4239 adult patients undergoing
Total hip and knee arthroplasty (THA, TKA) are largely successful procedures; however, both have variable outcomes, resulting in some patients being dissatisfied with the outcome. Surgeons are turning to technologies such as robotic-assisted surgery in an attempt to improve outcomes. Robust studies are needed to find out if these innovations are really benefitting patients. The Robotic Arthroplasty Clinical and Cost Effectiveness Randomised Controlled Trials (RACER) trials are multicentre, patient-blinded randomized controlled trials. The patients have primary osteoarthritis of the hip or knee. The operation is Mako-assisted THA or TKA and the control groups have operations using conventional instruments. The primary clinical outcome is the Forgotten Joint Score at 12 months, and there is a built-in analysis of cost-effectiveness. Secondary outcomes include early pain, the alignment of the components, and medium- to long-term outcomes. This annotation outlines the need to assess these technologies and discusses the design and challenges when conducting such trials, including surgical workflows, isolating the effect of the operation, blinding, and assessing the learning curve. Finally, the future of robotic surgery is discussed, including the need to contemporaneously introduce and evaluate such technologies. Cite this article:
We aim to explore the potential technologies for monitoring and assessment of patients undergoing arthroplasty by examining selected literature focusing on the technology currently available and reflecting on possible future development and application. The reviewed literature indicates a large variety of different hardware and software, widely available and used in a limited manner, to assess patients’ performance. There are extensive opportunities to enhance and integrate the systems which are already in existence to develop patient-specific pathways for rehabilitation. Cite this article:
This study aimed to assess the carbon footprint associated with total hip arthroplasty (THA) in a UK hospital setting, considering various components within the operating theatre. The primary objective was to identify actionable areas for reducing carbon emissions and promoting sustainable orthopaedic practices. Using a life-cycle assessment approach, we conducted a prospective study on ten cemented and ten hybrid THA cases, evaluating carbon emissions from anaesthetic room to recovery. Scope 1 and scope 2 emissions were considered, focusing on direct emissions and energy consumption. Data included detailed assessments of consumables, waste generation, and energy use during surgeries.Aims
Methods
Healthcare associated infections (HAI) pose a major threat to patients admitted to hospitals, and infection rates following orthopaedic
Objectives: To compare the results of various surgical approaches to the knee in primary
Introduction. Oral factor Xa inhibitors have recently been licensed for use as thromboprophylaxis in
Deep infection was identified as a serious complication in the earliest days of total hip arthroplasty. It was identified that airborne contamination in conventional operating theatres was the major contributing factor. As progress was made in improving the engineering of operating theatres, airborne contamination was reduced. Detailed studies were carried out relating airborne contamination to deep infection rates. In a trial conducted by the United Kingdom Medical Research Council (MRC), it was found that the use of ultra-clean air (UCA) operating theatres was associated with a significant reduction in deep infection rates. Deep infection rates were further reduced by the use of a body exhaust system. The MRC trial also included a detailed microbiology study, which confirmed the relationship between airborne contamination and deep infection rates. Recent observational evidence from joint registries has shown that in contemporary practice, infection rates remain a problem, and may be getting worse. Registry observations have also called into question the value of “laminar flow” operating theatres. Observational evidence from joint registries provides very limited evidence on the efficacy of UCA operating theatres. Although there have been some changes in surgical practice in recent years, the conclusions of the MRC trial remain valid, and the use of UCA is essential in preventing deep infection. There is evidence that if UCA operating theatres are not used correctly, they may have poor microbiological performance. Current UCA operating theatres have limitations, and further research is required to update them and improve their microbiological performance in contemporary practice. Cite this article:
Our aim was to examine the Elixhauser and Charlson comorbidity indices, based on administrative data available before surgery, and to establish their predictive value for mortality for patients who underwent hip arthroplasty in the management of a femoral neck fracture. We analyzed data from 42 354 patients from the Swedish Hip Arthroplasty Register between 2005 and 2012. Only the first operated hip was included for patients with bilateral arthroplasty. We obtained comorbidity data by linkage from the Swedish National Patient Register, as well as death dates from the national population register. We used univariable Cox regression models to predict mortality based on the comorbidity indices, as well as multivariable regression with age and gender. Predictive power was evaluated by a concordance index, ranging from 0.5 to 1 (with the higher value being the better predictive power). A concordance index less than 0.7 was considered poor. We used bootstrapping for internal validation of the results.Aims
Patients and Methods
There have been no complications or skin reactions related to this method of skin preparation. There has been no significant difference in the incidence of early post operative wound infection.
Osteolysis and subsequent mechanical loosening often occurs in hip arthroplasties using polyethylene-on-ceramic (POC) bearings. This has prompted an ongoing search for alternative bearing surfaces. Ceramic-on-ceramic (COC) and metal-on-metal (MOM) prostheses are widely used, with good clinical results. Using hip simulator studies, we compared ceramic-on-metal (COM) and MOM prostheses. We found COM pairings had 100-fold lower wear rates than MOM. The wear particles from both articulations were oval to round in shape and in the nanometer size range, with the COM producing smaller particles than the MOM. In both pairings, particle size decreased as the bearings bedded in. The volumetric particle loads were far smaller with COM bearing-surfaces than in currently-used MOM prostheses. These findings have encouraged us to investigate the use of these novel bearing surfaces. Ethical approval has been obtained, and a prospective randomised clinical trial comparing POC, MOM, COC and COM bearing surfaces has started.
We have come up with a 4-part stratification based on the patient’s primary condition and comorbidities and have evaluated this for a single-surgeon cohort of TKR patients and a multi-surgeon group of THR patients. We present the results and the implications of the findings and highlight the usability of the system.
The introduction of the laminar flow theatre was responsible for a decrease in wound infection four and a half fold. Further research has found that total body exhaust suits were also responsible for a reduction in infection rate. These exhaust suits include a toga hood, also supplied sterile and attached to the gown. There is no information from the manufacturers regarding microbial penetration of these hoods. Therefore we have performed an experiment to examine the potential for microbial penetration of these toga hoods, both when wet and dry.
Both wet and dry toga circles were applied to the previously prepared lawns of Staphylococcus epidermidis NCTC 11047, with the internal surface in contact with the lawn. Swabbings were taken from the external surface of both wet and dry toga circles at regular intervals. The timing of the swabbings were: 1 min, 5 mins, 20 mins, and 60 mins. The swabs were then used to inoculate blood agar plates, which were incubated overnight at 37°C, after which they were examined for growth of Staphylococcus epidermidis.