Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Bone & Joint Open
Vol. 4, Issue 9 | Pages 659 - 667
1 Sep 2023
Nasser AAHH Osman K Chauhan GS Prakash R Handford C Nandra RS Mahmood A

Aims

Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade.

Methods

Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 330 - 330
1 Sep 2012
London N Hayes D Waller C Smith J Williams R
Full Access

Introduction. Osteoarthritis (OA) represents a leading cause of disability and a growing burden on healthcare budgets. OA is particularly vexing for young, active patients who have failed less invasive therapies but are not yet candidates for arthroplasty. Often, patients suffering in this wide therapeutic gap face a debilitating spiral of disease progression, increasing pain, and decreasing activity until they become suitable arthroplasty patients. An implantable load absorber was evaluated for the treatment of medial knee OA in this patient population. Joint overload has been cited as a contributor to OA onset or progression. In response, the KineSpring® System (Moximed, Inc, USA) has been designed to reduce the load acting on the knee. The absorber is implanted in the subcutaneous tissue without violating the joint capsule, thus preserving the option of future arthroplasty. The implant is particularly useful for young, active patients, given the reversibility of the procedure and the preservation of normal flexibility and range of motion. Methods and Results. The KineSpring System was implanted in 55 patients, with the longest duration exceeding two years. The treated group had medial knee OA, included younger OA sufferers (range 31–68 years), with a mean BMI > 30kg/m2. Acute implant success, adverse events, and clinical outcomes using validated patient reported outcomes tools were recorded at baseline, post-op, 2 and 6 weeks, and 3, 6, 12 and 24 months post-op. All patients were successfully implanted with a mean procedure time of 76.4 min (range 54–153 minutes). Mean hospital length of stay was 1.7 days (range 1–3 days), and patients recovered rapidly, achieving full weight bearing within 1–2 wks and normal range of motion by 6 weeks. Most patients experienced pain relief and functional improvement with 85% (35/41) reporting none or mild pain on the WOMAC pain subscale and 90% (37/41) reporting functional impairment as none on mild on the WOMAC function subscale at the latest follow-up visit (mean 9.3 ± 3.5 months). Clinically meaningful and statistically significant pain reduction and functional improvement were noted with baseline WOMAC pain scores (0–100 scale) improving from 42.4 to 16.1 (p<0.001) and WOMAC function (0–100 scale) improving from 42.0 to 14.7 (p<0.001) at latest follow-up. Patients reported satisfaction with the implant and its appearance. Conclusions. The KineSpring System preserves natural knee anatomy and kinematics while providing pain reduction and resumption of high activity levels that have proven durable. This device, with these excellent results, fills a major gap in treatment options for young and active OA patients


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 406 - 412
1 Mar 2010
Leonardsson O Sernbo I Carlsson Å åkesson K Rogmark C

In a series of 450 patients over 70 years of age with displaced fractures of the femoral neck sustained between 1995 and 1997 treatment was randomised either to internal fixation or replacement. Depending on age and level of activity the latter was either a total hip replacement or a hemiarthroplasty. Patients who were confused or bed-ridden were excluded, as were those with rheumatoid arthritis. At ten years there were 99 failures (45.6%) after internal fixation compared with 17 (8.8%) after replacement. The rate of mortality was high at 75% at ten years, and was the same in both groups at all times. Patient-reported pain and function were similar in both groups at five and ten years. Those with successfully healed fractures had more hip pain and reduction of mobility at four months compared with patients with an uncomplicated replacement, and they never attained a better outcome than the latter patients regarding pain or function.

Primary replacement gave reliable long-term results in patients with a displaced fracture of the femoral neck.