Advertisement for orthosearch.org.uk
Results 1 - 20 of 1883
Results per page:
Bone & Joint Open
Vol. 5, Issue 9 | Pages 749 - 757
12 Sep 2024
Hajialiloo Sami S Kargar Shooroki K Ammar W Nahvizadeh S Mohammadi M Dehghani R Toloue B

Aims. The ulna is an extremely rare location for primary bone tumours of the elbow in paediatrics. Although several reconstruction options are available, the optimal reconstruction method is still unknown due to the rarity of proximal ulna tumours. In this study, we report the outcomes of osteoarticular ulna allograft for the reconstruction of proximal ulna tumours. Methods. Medical profiles of 13 patients, who between March 2004 and November 2021 underwent osteoarticular ulna allograft reconstruction after the resection of the proximal ulna tumour, were retrospectively reviewed. The outcomes were measured clinically by the assessment of elbow range of motion (ROM), stability, and function, and radiologically by the assessment of allograft-host junction union, recurrence, and joint degeneration. The elbow function was assessed objectively by the Musculoskeletal Tumor Society (MSTS) score and subjectively by the Toronto Extremity Salvage Score (TESS) and Mayo Elbow Performance Score (MEPS) questionnaire. Results. The mean follow-up of patients was 60.3 months (SD 28.5). The mean elbow flexion-extension ROM was 95.8° (SD 21). The mean MSTS of the patients was 84.4 (SD 8.2), the mean TESS was 83.8 (SD 6.7), and the mean MEPS was 79.2 (SD 11.5). All the patients had radiological union at the osteotomy site. Symptomatic osteoarthritic change was observed in three patients (23%), one of whom ended up with elbow joint fusion. Two patients (15.4%) had recurrence during the follow-up period. Surgical complications included two allograft fractures, two plate fractures, three medial instabilities, and two infections. Conclusion. Osteoarticular ulna allograft reconstruction provides acceptable functional outcomes. Despite a high rate of complications, it is still a valuable reconstruction method, particularly in skeletally immature patients who need their distal humerus physis for the rest of hand growth. Cite this article: Bone Jt Open 2024;5(9):749–757


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1174 - 1179
1 Oct 2022
Jamshidi K Bagherifard A Mirzaei A

Aims. Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children. Methods. A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score. Results. At final follow-up, the knee was unstable in 9/18 patients (50%) in the osteoarticular allograft group and 2/15 patients (13%) in the rAPC group (p = 0.026). The median range of motion (ROM) of the knee was 117° (IQR 115° to 120°) in the osteoarticular allograft group and 100° (IQR 95° to 105°) in the rAPC group (p < 0.001). The median MSTS score was 25 (IQR 23 to 26) in the osteoarticular allograft group and 28 (IQR 26 to 29) in the rAPC group (p = 0.007). Osteoarthritic change was detected in 11/18 patients (61%) in the osteoarticular allograft group and in 4/15 (26%) patients in the rAPC group (p = 0.048). Conclusion. In our series, a resurfaced allograft-prosthesis composite provided better knee stability and function, with a lower rate of osteoarthritis; an osteoarticular allograft was associated with better knee ROM. Cite this article: Bone Joint J 2022;104-B(10):1174–1179


Bone & Joint Open
Vol. 5, Issue 5 | Pages 385 - 393
13 May 2024
Jamshidi K Toloue Ghamari B Ammar W Mirzaei A

Aims. Ilium is the most common site of pelvic Ewing’s sarcoma (ES). Resection of the ilium and iliosacral joint causes pelvic disruption. However, the outcomes of resection and reconstruction are not well described. In this study, we report patients’ outcomes after resection of the ilium and iliosacral ES and reconstruction with a tibial strut allograft. Methods. Medical files of 43 patients with ilium and iliosacral ES who underwent surgical resection and reconstruction with a tibial strut allograft between January 2010 and October 2021 were reviewed. The lesions were classified into four resection zones: I. 1. , I. 2. , I. 3. , and I. 4. , based on the extent of resection. Functional outcomes, oncological outcomes, and surgical complications for each resection zone were of interest. Functional outcomes were assessed using a Musculoskeletal Tumor Society (MSTS) score and Toronto Extremity Salvage Score (TESS). Results. The mean age of the patients was 17 years (SD 9.1). At a mean follow-up of 70.8 months (SD 50), the mean functional outcomes were 24.2 points (SD 6.3) for MSTS and 81 points (SD 11) for TESS. The mean MSTS and TESS scores were associated with the iliac resection zone (< 0.001). Nine patients (20.9%) had local recurrence. The recurrence was not associated with the zone of iliac resection (p = 0.324). The two-year disease-free survival of the patients was 69.4%. The mean time to graft union was longer in patients with the I. 4. resection zone (p < 0.001). The complication rate was 34.9%, and nerve palsy (11.6%) was the most common. The rate of surgical complications was not associated with the resection zone. Conclusion. Reconstruction using tibial strut allograft is an efficient procedure after the resection of the ilium and iliosacral ES. Functional outcomes and complications of iliac ES depend on the resection zone, and inferior outcomes could be generally expected when more segments of the pelvic ring are resected, even if it is reconstructed. Cite this article: Bone Jt Open 2024;5(5):385–393


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 14 - 14
4 Apr 2023
Luk J
Full Access

In this study, we aimed to investigate tibiofemoral and allograft loading parameters after OCA transplantation using tibial plateau shell grafts to characterize the clinically relevant biomechanics that may influence joint kinematics and OCA osseointegration after transplantation. The study was designed to test the hypothesis that there are significant changes in joint loading after tibial plateau OCA transplantation that may require unique post-operative rehabilitation regimens in patients to restore balance in the knee joint. Fresh-frozen cadaveric knees (n=6) were thawed and mounted onto a 6 DOF KUKA robot. Specimens were size matched to +2 mm for the medial-to-lateral width of the medial tibial hemiplateaus. Three specimens served as allograft recipient knees and three served as donor knees. Recipient knees were first tested in their native state and then tested with size-matched medial tibial hemiplateau shell grafts (n=3) prepared from the donor knees using custom-cut tab-in-slot and subchondral drilling techniques. Tekscan sensors were placed in the joint spaces to evaluate the loading conditions under 90N biaxial loading at full extension of the knee before and after graft placement. The I-Scan system used in conjunction analyzed the total force, pressure distribution, peak pressure, and center of force within the joint space. Data demonstrated significant difference (p<0.05) in joint space loading after graft implantation compared to controls in both lateral and medial tibial plateaus. The I-Scan pressure mapping system displayed changes in femoral condylar contact points as well. The results demonstrated that joint space loading was significantly different (p<0.05) between all preoperative and postoperative cadaveric specimens. Despite the best efforts to size match grafts, slight differences in the host's joint geometry resulted in shifts of contact areas between the tibial plateau and femoral condyle therefore causing either an increase or decrease in pressure measured by the sensor. This concludes that accuracy in graft size matching is extremely important to restoring close to normal loading across the joint and this can be further ensured through postoperative care customized to the patient after OCA surgery


Bone & Joint Open
Vol. 5, Issue 7 | Pages 570 - 580
10 Jul 2024
Poursalehian M Ghaderpanah R Bagheri N Mortazavi SMJ

Aims. To systematically review the predominant complication rates and changes to patient-reported outcome measures (PROMs) following osteochondral allograft (OCA) transplantation for shoulder instability. Methods. This systematic review, following PRISMA guidelines and registered in PROSPERO, involved a comprehensive literature search using PubMed, Embase, Web of Science, and Scopus. Key search terms included “allograft”, “shoulder”, “humerus”, and “glenoid”. The review encompassed 37 studies with 456 patients, focusing on primary outcomes like failure rates and secondary outcomes such as PROMs and functional test results. Results. A meta-analysis of primary outcomes across 17 studies revealed a dislocation rate of 5.1% and an increase in reoperation rates from 9.3% to 13.7% post-publication bias adjustment. There was also a noted rise in conversion to total shoulder arthroplasty and incidence of osteoarthritis/osteonecrosis over longer follow-up periods. Patient-reported outcomes and functional tests generally showed improvement, albeit with notable variability across studies. A concerning observation was the consistent presence of allograft resorption, with rates ranging from 33% to 80%. Comparative studies highlighted similar efficacy between distal tibial allografts and Latarjet procedures in most respects, with some differences in specific tests. Conclusion. OCA transplantation presents a promising treatment option for shoulder instability, effectively addressing both glenoid and humeral head defects with favourable patient-reported outcomes. These findings advocate for the inclusion of OCA transplantation in treatment protocols for shoulder instability, while also emphasizing the need for further high-quality, long-term research to better understand the procedure’s efficacy profile. Cite this article: Bone Jt Open 2024;5(7):570–580


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims. To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia. Methods. We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure. Results. A total of 64 patients (76 hips) were included in this study. The median follow-up period was ten years (interquartile range (IQR) five to 14). The median mHHS improved from 67 (IQR 56 to 80) preoperatively to 96 (IQR 85 to 97) at the latest follow-up (p < 0.001). The radiological parameters improved postoperatively (p < 0.001), with the resulting parameters falling within the normal range in 42% to 95% of hips. The survival rate was 95% at ten years and 80% at 15 years. Preoperative Tönnis grade 2 was an independent risk factor for TOA failure. Conclusion. Our findings suggest that TOA with structural bone allografting is a viable surgical option for correcting severely dysplastic acetabulum in adolescents and young adults without advanced osteoarthritis, with favourable mid-term outcomes. Cite this article: Bone Joint J 2023;105-B(7):743–750


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 91 - 96
1 Jan 2022
Modi A Haque A Deore V Singh HP Pandey R

Aims. Long-term outcomes following the use of human dermal allografts in the treatment of symptomatic irreparable rotator cuff tears are not known. The aim of this study was to evaluate these outcomes, and to investigate whether this would be a good form of treatment in young patients in whom a reverse shoulder arthroplasty should ideally be avoided. Methods. This prospective study included 47 shoulders in 45 patients who underwent an open reconstruction of the rotator cuff using an interposition GraftJacket allograft to bridge irreparable cuff tears, between January 2007 and November 2011. The Oxford Shoulder Score (OSS), pain score, and range of motion (ROM) were recorded preoperatively and at one year and a mean of 9.1 years (7.0 to 12.5) postoperatively. Results. There was significant improvement in the mean OSS from 24.7 (SD 5.4) preoperatively to 42.0 (SD 6.3) at one year, and this improvement was maintained at 9.1 years (p < 0.001), with a score of 42.8 (SD 6.8). Similar significant improvements in the pain score were seen and maintained at the final follow-up from 6.1 (SD 1.6) to 2.1 (SD 2.3) (p < 0.001). There were also significant improvements in the ROM of the shoulder, and patient satisfaction was high. Conclusion. The use of an interposition human dermal allograft in patients with an irreparable rotator cuff tear leads to good outcomes that are maintained at a mean of nine years postoperatively. Cite this article: Bone Joint J 2022;104-B(1):91–96


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1078 - 1085
1 Oct 2023
Cance N Batailler C Shatrov J Canetti R Servien E Lustig S

Aims. Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure. Methods. Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m. 2. (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion. Results. The mean follow-up was 51 months (SD 26; 24 to 121). Bony union was confirmed in 95% of patients (128/135) at a mean of 3.4 months (SD 2.7). The complication rate was 15% (20/135), consisting of nine tibial tubercle fracture displacements (6.7%), seven nonunions (5%), two delayed unions, one tibial fracture, and one wound dehiscence. Seven patients (5%) required eight revision procedures (6%): three bone grafts, three osteosyntheses, one extensor mechanism allograft, and one wound revision. The functional scores and flexion were significantly improved after surgery: mean KSS knee, 48.8 (SD 17) vs 79.6 (SD 20; p < 0.001); mean KSS function, 37.6 (SD 21) vs 70.2 (SD 30; p < 0.001); mean flexion, 81.5° (SD 33°) vs 93° (SD 29°; p = 0.004). Overall, 98% of patients (n = 132) had no extension deficit. The use of hinge implants was a significant risk factor for tibial tubercle fracture (p = 0.011). Conclusion. TTO during rTKA was an efficient procedure to improve knee exposure with a high union rate, but had significant specific complications. Functional outcomes were improved at mid term. Cite this article: Bone Joint J 2023;105-B(10):1078–1085


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 39 - 39
1 Mar 2008
Frei H Mitchell P Masri B Duncan C Oxland T
Full Access

Impaction allografting is increasingly used for the treatment of failed total hip replacements. In six human cadaveric femurs the impaction allografting procedure was performed to comprehensively describe the postoperative morphology of impaction allografting. After the procedure, the specimens were sectioned and prepared for histomorphometric analysis. The graft porosity was lowest in Gruen zone four (52%) and highest in Gruen zone one (76%). At the level of Gruen zone six and two, virtually the entire cross-section was filled with bone cement. The presented data will serve as a baseline for future investigations of the impaction allografting. Impaction allografting is an attractive procedure for the treatment of failed total hip replacements. The purpose of this study was to comprehensively describe the morphology of impaction allografting post operatively to form a baseline for further investigations. Three experienced surgeons performed the impaction allografting procedure on six cadaveric femurs. After the procedure, the femurs were cut in 6mm thick transverse sections and processed for histomorphometric analysis. The porosity of the impacted graft was highest proximally in Gruen zone one (76%) and lowest in Gruen zone four (52%). Below the tip of the stem (Gruen zone four), the mean cement penetration was significantly lower compared to the proximal part of the femur. The averaged residual impacted graft layer in Gruen zone six and two was (0.5mm SD 0.4mm) significantly thinner compared with Gruen zone’s one, 7/1, and four. In the region of Gruen zone six and two the entire cross-section was penetrated with bone cement with almost no residual graft layer (Figure). Even the simulated lytic defects in this region were filled with the graft cement composite which may not be remodelled by the host bone. The graft porosity was found to be highest proximally and lowest distally. In the region of Gruen zone six and two the entire cross-section was penetrated with bone cement with almost no residual graft layer. This investigation will serve as a baseline for future studies of the mechanical and biological processes that make the impaction allografting a successful procedure. Funding: Stryker Howmedica and DePuy for provided implants and instruments. Please contact author for figures and/or diagrams


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 42 - 42
4 Apr 2023
Benca E van Knegsel K Zderic I Caspar J Strassl A Hirtler L Fuchssteiner C Gueorguiev B Windhager R Widhalm H Varga P
Full Access

Screw fixation is an established method for anterior cruciate ligament (ACL) reconstruction, although with a high rate of implant-related complications. An allograft system for implant fixation in ACL reconstruction, the Shark Screw ACL (surgebright GmbH) could overcome some of the shortcomings of bioabsorbable screws, such as foreign body reaction, need for implant removal and imaging artefacts. However, it needs to provide sufficient mechanical stability. Therefore, the aim of this study was to investigate the biomechanical stability, especially graft slippage, of the novel allograft system versus a conventional bioabsorbable interference screw (BioComposite Interference Screw; Arthrex Inc.) for tibial implant fixation in ACL reconstruction. Twenty-four paired human proximal tibiae (3 female, 9 male, 72.7 ± 5.6 years) underwent ACL reconstruction. The quadrupled semitendinosus and gracilis tendon graft were fixed in one specimen of each pair using the allograft fixation system Shak Screw ACL and the contralateral one using an interference screw. All specimens were cyclically loaded at 1 Hz with peak load levels monotonically increased from 50 N at a rate of 0.1 N/cycle until catastrophic failure. Relative movements of the graft versus the tibia were captured with a stereographic optical motion tracking system (Aramis SRX; GOM GmbH). The two fixation methods did not demonstrate any statistical difference in ultimate load at graft slippage (p = 0.24) or estimated survival at slippage (p = 0.06). Both, the ultimate load and estimated survival until failure were higher in the interference screw (p = 0.04, and p = 0.018, respectively). Graft displacement at ultimate load reached values of up to 7.2 mm (interference screw) and 11.3 mm (Shark Screw ACL). The allograft screw for implant fixation in ACL reconstruction showed similar behavior in terms of graft slippage compared to the conventional metal interference screw but underperformed in terms of ultimate load. However, the ultimate load may not be considered a direct indicator of clinical failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 15 - 15
4 Apr 2023
Luk J
Full Access

Many factors have been reported to affect the functional survival of OCA transplants, including chondrocyte viability at time of transplantation, rate and extent of allograft bone integration, transplantation techniques, and postoperative rehabilitation protocols and adherence. The objective of this study was to determine the optimal subchondral bone drilling technique by evaluating the effects of hole diameter on the material properties of OCAs while also considering total surface area for potential biologic benefits for cell and vascular ingrowth. Using allograft tissues that would be otherwise discarded in combination with deidentified diagnostic imaging (MRI and CT), a model of a large shell osteochondral allograft was recreated using LS-PrePost and FEBio based on clinically relevant elastic material properties for cortical bone, trabecular bone, cartilage, and hole ingrowth tissue. The 0.8 mesh size model consisted of 4 mm trabecular bone, 4 mm cortical bone, and 3 mm cartilage sections that summed to a cross-sectional area of 1600 mm2 (40 mm x 40 mm). Holes were modeled to be 4mm deep in relation to clinical practice where holes are drilled from the deep margin of subchondral trabecular bone to the cortical subchondral bone plate. To test the biomechanic variations between drill hole sizes, models with hole sizes pertinent to standard-of-care commercially available orthopaedic drill sizes of 1.1mm, 2.4 mm, or 4.0 mm holes were loaded across the top surface over a one second duration and evaluated for effective stress, effective strain, 1st principal strain, and 3rd principal strain in compressive conditions. Results measured effective stress and strain and 1st and 3rd principal strain increased with hole depth. The results of the present FEA modeling study indicate that the larger 4.0 mm diameter holes were associated with greater stresses and strains within OCA shell graft, which may render the allograft at higher risk for mechanical failure. Based on these initial results, the smaller diameter 2.4 mm and 1.1 mm holes will be further investigated to determine optimal number, configuration, and depth of subchondral drilling for OCA preparation for transplantation


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 297 - 301
1 Feb 2022
Jamshidi K Bagherifard A Mohaghegh MR Mirzaei A

Aims. Giant cell tumours (GCTs) of the proximal femur are rare, and there is no consensus about the best method of filling the defect left by curettage. In this study, we compared the outcome of using a fibular strut allograft and bone cement to reconstruct the bone defect after extended curettage of a GCT of the proximal femur. Methods. In a retrospective study, we reviewed 26 patients with a GCT of the proximal femur in whom the bone defect had been filled with either a fibular strut allograft (n = 12) or bone cement (n = 14). Their demographic details and oncological and nononcological complications were retrieved from their medical records. Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) score. Results. Mean follow-up was 116 months (SD 59.2; 48 to 240) for the fibular strut allograft group and 113 months (SD 43.7; 60 to 192) for the bone cement group (p = 0.391). The rate of recurrence was not significantly different between the two groups (25% vs 21.4%). The rate of nononcological complications was 16.7% in the strut allograft group and 42.8% in the bone cement group. Degenerative joint disease was the most frequent nononcological complication in the cement group. The mean MSTS score of the patients was 92.4% (SD 11.5%; 73.3% to 100.0%) in the fibular strut allograft group and 74.2% (SD 10.5%; 66.7% to 96.7%) in the bone cement group (p < 0.001). Conclusion. Given the similar rate of recurrence and a lower rate of nononcological complications, fibular strut grafting could be recommended as a method of reconstructing the bone defect left by curettage of a GCT of the proximal femur. Cite this article: Bone Joint J 2022;104-B(2):297–301


Bone & Joint 360
Vol. 13, Issue 4 | Pages 35 - 37
2 Aug 2024

The August 2024 Oncology Roundup. 360. looks at: What factors are associated with osteoarthritis after cementation for benign aggressive bone tumour of the knee joint: a systematic review and meta-analysis; Recycled bone grafts treated with extracorporeal irradiation or liquid nitrogen freezing after malignant tumour resection; Intercalary resection of the tibia for primary bone tumours: are vascularized fibula autografts with or without allografts a durable reconstruction?; 3D-printed modular prostheses for the reconstruction of intercalary bone defects after joint-sparing limb salvage surgery for femoral diaphyseal tumours; Factors influencing the outcome of patients with primary Ewing’s sarcoma of the sacrum; The significance of surveillance imaging in children with Ewing’s sarcoma and osteosarcoma; Resection margin and soft-tissue sarcomas of the extremities treated with limb-sparing surgery and postoperative radiotherapy


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 40 - 40
4 Apr 2023
Evrard R Maistriaux L Manon J Rafferty C Cornu O Gianello P Lengelé B Schubert T
Full Access

The purpose of this study is to enhance massive bone allografts osseointegration used to reconstruct large bone defects. These allografts show >50% complication rate requiring surgical revision in 20% cases. A new protocol for total bone decellularisation exploiting the vasculature can offer a reduction of postoperative complication by annihilating immune response and improving cellular colonization/ osseointegration. The nutrient artery of 18 porcine bones - humerus/femur/radius/ulna - was cannulated. The decellularization process involved immersion and sequential perfusion with specific solvents over a course of one week. Perfusion was realized by a peristaltic pump (mean flow rate: 6ml/min). The benefit of arterial perfusion was compared to a control group kept in immersion baths without perfusion. Bone samples were processed for histology (HE, Masson's trichrome and DAPI for cell detection), immunohistochemistry (IHC : Collagen IV/elastin for intraosseous vascular system evaluation, Swine Leukocyte Antigen – SLA for immunogenicity in addition to cellular clearance) and DNA quantification. Sterility and solvent residues in the graft were also evaluated with thioglycolate test and pH test respectively. Compared to native bones, no cells could be detected and residual DNA was <50ng/mg dry weight. Intramedullary spaces were completely cleaned. IHC showed the preservation of intracortical vasculature with channels bounded by Collagen IV and elastin within Haversian systems. IHC also showed a significant decrease in SLA signaling. All grafts were sterile at the last decellularization step and showed no solvent residue. The control group kept in immersion baths, paired with 6 perfused radii/ulnae, showed that the perfusion is mandatory to ensure complete decellularisation. Our results prove the effectiveness of a new concept of total bone decellularisation by perfusion. These promising results could lead to a new technique of Vascularized Composite Allograft transposable to pre-clinical and clinical models


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 8 - 8
2 Jan 2024
Koshanova A Tuleubayev B Saginova D Akhmetova S Tashmetov E
Full Access

Bone infections due to fractures or implants are a big medical problem. In experimental medicine, many experimental models have been created on different animal species to simulate the disease condition and to do experience treatments. The aim of this paper was to present an antibacterial efficacy of using a bone allograft developed according to the Marburg system of bone bank on a model of chronic osteomyelitis induced in rabbits. In research was used 54 rabbits. Osteomyelitis was induced in rabbits by a human strain of St. aureus ATCC 43300, in the rabbit femur. There have been created 3 groups of animals. In 1. st. group used antibiotic impregnated biodegradable material “PerOssal”. In 2. nd. group used antibiotic impregnated whole bone allograft. In 3. rd. group used antibiotic impregnated perforated bone allograft. Evaluation of installation and evolution of the disease was done by microbiological. A separate study of microbiological data is presented here. This study showed, in the 1. st. and 3. rd. groups there is a persistent decrease in CFU by 14 knocks to 120.4 in the 1. st. group and to 3.5 in the 3. rd. group, and in the 2. nd. group, on the contrary, there is an increase in CFU to 237.33. This shows the lack of effectiveness of using a whole bone allograft. The results showed, after 7 days there was no statistically significant difference between the groups. After 14 days the perforated bone allograft impregnated with antibiotic was better than the biodegradable material “PerOssal”


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1321 - 1326
1 Nov 2024
Sanchez-Sotelo J

Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty. Cite this article: Bone Joint J 2024;106-B(11):1321–1326


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 4 - 4
1 Dec 2020
Tashmetov E Tuleubaev B Saginova D Koshanova A Rustambek I
Full Access

Introduction. Cancellous and cortical bone used as a delivery vehicle for antibiotics. Recent studies with cancellous bone as an antibiotic carrier in vitro and in vivo showed high initial peak concentrations of antibiotics in the surrounding medium. However, high concentrations of antibiotics can substantially reduce osteoblast replication and even cause cell death. Objectives. To determine whether impregnation with gentamycine impair the incorporation of bone allografts, as compared to allografts without antibiotic. Materials and method. Seventy two healthy rabbits (24 rabbits in each group) were used for this study. Bone defects (3-mm diameter, 10-mm depth) were created in the femur. Human femoral head prepared according to the Marburg bone bank system was used as bone allograft. In the experimental groups, in 1 group - the defects were filled with bone allografts, in 2 group – Perforated Gentamycin-impregnated bone allografts. The control group did not receive any filling. The animals were killed after 14, 30 and 60 days. Evaluations consisted of X-ray plain radiography, histology at 14-, 30- and 60-days post-surgery. Results. Active osteoblast activity and active formation of new bones were detected around the defect area in all groups, but the amount of new bone formation was greater in the experimental groups than the control group. We found no statistically significant differences in the rate of bone formation between 1 and 2 groups at 14, 30 and 60 days in any of the parameters studied. X-ray results showed no significant difference in bony callus formation around allografts in 1 and 2 groups. In contrast, no significant callus formation was observed in the control group. Conclusion. The use of gentamycin-impregnated bone allografts may be of value in procedures performed at the site of osteomyelitis which require a second stage reconstruction with impacted bone grafting techniques


Bone & Joint Open
Vol. 3, Issue 9 | Pages 733 - 740
21 Sep 2022
Sacchetti F Aston W Pollock R Gikas P Cuomo P Gerrand C

Aims. The proximal tibia (PT) is the anatomical site most frequently affected by primary bone tumours after the distal femur. Reconstruction of the PT remains challenging because of the poor soft-tissue cover and the need to reconstruct the extensor mechanism. Reconstructive techniques include implantation of massive endoprosthesis (megaprosthesis), osteoarticular allografts (OAs), or allograft-prosthesis composites (APCs). Methods. This was a retrospective analysis of clinical data relating to patients who underwent proximal tibial arthroplasty in our regional bone tumour centre from 2010 to 2018. Results. A total of 76 patients fulfilled the inclusion criteria and were included in the study. Mean age at surgery was 43.2 years (12 to 86 (SD 21)). The mean follow-up period was 60.1 months (5.4 to 353). In total 21 failures were identified, giving an overall failure rate of 27.6%. Prosthesis survival at five years was 75.5%, and at ten years was 59%. At last follow-up, mean knee flexion was 89.8° (SD 36°) with a mean extensor lag of 18.1° (SD 24°). In univariate analysis, factors associated with better survival of the prosthesis were a malignant or metastatic cancer diagnosis (versus benign), with a five- and ten-year survival of 78.9% and 65.7% versus 37.5% (p = 0.045), while in-hospital length of stay longer than nine days was also associated with better prognosis with five- and ten-year survival rates at 84% and 84% versus 60% and 16% (p < 0.001). In multivariate analysis, only in-hospital length of stay was associated with longer survival (hazard ratio (HR) 0.23, 95% confidence interval (CI) 0.08 to 0.66). Conclusion. We have shown that proximal tibial arthroplasty with endoprosthesis is a safe and reliable method for reconstruction in patients treated for orthopaedic oncological conditions. Either modular or custom implants in this series performed well. Cite this article: Bone Jt Open 2022;3(9):733–740


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 5 - 5
1 Feb 2020
Jenny J Guillotin C Boeri C
Full Access

Introduction. Chronic ruptures of the quadriceps tendon after total knee arthroplasty (TKA) are rare but are a devastating complication. The objective of this study was to validate the use of fresh frozen total fresh quadriceps tendon allografts for quadriceps tendon reconstruction. The hypothesis of this work was that the graft was functional in more than 67% of cases, a higher percentage than the results of conventional treatments. Material – methods. We designed a continuous monocentric retrospective study of all patients operated on between 2009 and 2017 for a chronic rupture of the quadriceps tendon after TKA by quadriceps allograft reconstruction. The usual demographic and perioperative data and the rehabilitation protocols followed were collected. Initial and final radiographs were analyzed to measure patellar height variation. The main criterion was the possibility of achieving an active extension of the knee with a quadriceps contraction force greater than or equal to 3/5 or the possibility of lifting the heel off the ground in a sitting position. Results. 29 patients with 33 allografts were included; 3 iterative allografts were performed on ruptures of the initial transplant and 1 patient was grafted on both sides in one step. There were 21 women and 8 men with a mean age of 73 years, and a mean body mass index of 33 kg/m. 2. Ruptures occurred in 22 cases after chronic periprosthetic infection. Walking was allowed immediately in 29 cases, but free mobilization was delayed in 29 cases. Complications affected 22 cases, but the majority of complications were not related to allograft use (including infectious failures and periprosthetic fractures). After a mean follow-up of 52 months, 28 allografts were still in place, and 22 allografts were considered functional. The active quadriceps extension force was rated on average at 3.5/5. The average pre/post-operative patellar height differential was +2 mm. Discussion. This continuous series of 33 allografts is in line with recent publications on the subject. It confirms their negative impact on the functional outcome of the TKA. The complication rate is high but the specific complication rate is not prohibitive. Two thirds of transplants are functional in the long term. Early rehabilitation procedures can be used in these difficult patients with encouraging results. The management of chronic ruptures of the quadriceps tendon after TKA by quadriceps allograft must be part of the current therapeutic options


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 74 - 74
1 Dec 2022
Changoor A Suderman R Wood B Grynpas M Hurtig M Kuzyk P
Full Access

Large cartilage lesions in younger patients can be treated by fresh osteochondral allograft transplantation, a surgical technique that relies on stable initial fixation and a minimum chondrocyte viability of 70% in the donor tissue to be successful. The Missouri Osteochondral Allograft Preservation System (MOPS) may extend the time when stored osteochondral tissues remain viable. This study aimed to provide an independent evaluation of MOPS storage by evaluating chondrocyte viability, chondrocyte metabolism, and the cartilage extracellular matrix using an ovine model. Femoral condyles from twelve female Arcott sheep (6 years, 70 ± 15 kg) were assigned to storage times of 0 (control), 14, 28, or 56 days. Sheep were assigned to standard of care [SOC, Lactated Ringer's solution, cefazolin (1 g/L), bacitracin (50,000 U/L), 4°C storage] or MOPS [proprietary media, 22-25°C storage]. Samples underwent weekly media changes. Chondrocyte viability was assessed using Calcein AM/Ethidium Homodimer and reported as percent live cells and viable cell density (VCD). Metabolism was evaluated with the Alamar blue assay and reported as Relative Fluorescent Units (RFU)/mg. Electromechanical properties were measured with the Arthro-BST, a device used to non-destructively compress cartilage and calculate a quantitative parameter (QP) that is inversely proportional to stiffness. Proteoglycan content was quantified using the dimethylmethylene blue assay of digested cartilage and distribution visualized by Safranin-O/Fast Green staining of histological sections. A two-way ANOVA and Tukey's post hoc were performed. Compared to controls, MOPS samples had fewer live cells (p=0.0002) and lower VCD (p=0.0004) after 56 days of storage, while SOC samples had fewer live cells (p=0.0004, 28 days; p=0.0002, 56 days) and lower VCD (p=0.0002, 28 days; p=0.0001, 56 days) after both 28 and 56 days (Table 1). At 14 days, the percentage of viable cells in SOC samples were statistically the same as controls but VCD was lower (p=0.0197). Cell metabolism in MOPS samples remained the same over the study duration but SOC had lower RFU/mg after 28 (p=0.0005) and 56 (p=0.0001) days in storage compared to controls. These data show that MOPS maintained viability up to 28 days yet metabolism was sustained for 56 days, suggesting that the conditions provided by MOPS storage allowed fewer cells to achieve the same metabolic levels as fresh cartilage. Electromechanical QP measurements revealed no differences between storage methods at any individual time point. QP data could not be used to interpret changes over time because a mix of medial and lateral condyles were used and they have intrinsically different properties. Proteoglycan content in MOPS samples remained the same over time but SOC was significantly lower after 56 days (p=0.0086) compared to controls. Safranin-O/Fast Green showed proteoglycan diminished gradually beginning at the articular surface and progressing towards bone in SOC samples, while MOPS maintained proteoglycan over the study duration (Figure 1). MOPS exhibited superior viability, metabolic activity and proteoglycan retention compared to SOC, but did not maintain viability for 56 days. Elucidating the effects of prolonged MOPS storage on cartilage properties supports efforts to increase the supply of fresh osteochondral allografts for clinical use. For any figures or tables, please contact the authors directly