Total knee replacement (TKA) is one of the most successful procedures in orthopaedic surgery. Although originally limited to more elderly and less active individuals, the inclusion criteria for TKA have changed, with ever younger, more active and heavier patients receiving TKA. This broadening of indications coincided with the widespread adoption of modular cemented and cementless TKA systems in the 1980's, and soon thereafter wear debris related osteolysis and associated prosthetic loosening became major modes of failure for TKA implants of all designs. Initially, tibial components were cemented all polyethylene monoblock constructs. Subsequent long-term follow-up studies of some of these implant designs have demonstrated excellent durability in survivorship studies out to twenty years. While aseptic loosening of these all polyethylene tibial components was a leading cause of failure in these implants, major polyethylene wear-related osteolysis around well-fixed implants was rarely (if ever) observed. Cemented metal-backed nonmodular tibial components were first introduced to allow for improved tibial load distribution and protection of the underlying (often osteoporotic) bone. Eventually, modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-80s mainly to facilitate screw fixation for cementless implants. These designs also provided intraoperative versatility by allowing interchange of various polyethylene thicknesses, and also aided the addition of stems and wedges. Modular vs. All Polyethylene Tibial Components in Primary TKA: Kremers et al. reviewed 10,601 adult (>18 years) patients with 14,524 condylar type primary TKA procedures performed at our institution between 1/1/1988 and 12/31/2005 and examined factors effecting outcome. The mean age was 68.7 years and 55% were female. Over an average 9 years follow-up, a total of 865 revisions, including 252 tibia revisions were performed, corresponding to overall survival of 89% (Confidence intervals (CI): 88%, 90%) at 15 years. In comparison to metal modular designs, risk of tibial revision was significantly lower with all polyethylene tibias (HR 0.3, 95% CI: 0.2, 0.5). With any revision as the endpoint, there were no significant differences across the 18 designs examined. Similarly, there were no significant differences across the 18 designs when we considered revisions for aseptic loosening, wear, osteolysis. Among patient characteristics, male gender, younger
Two big problems exist with the all polyethylene cemented tibial component; the polyethylene and the cement. The polyethylene is too weak and flexible to bear high tibial load, so it deforms and loosens. The interface stresses are too high when two flexible structures are poorly bonded and heavily loaded. Modularity between the polyethylene tibial component and the metal-backed tray was introduced in the mid-80's for versatility and to facilitate screw fixation for cementless implants. These designs allow exchange of various polyethylene thicknesses, and aids the addition of stems and wedges. Other advantages include the reduction of inventory, and the potential for isolated tibial polyethylene exchanges as a simpler revision procedure. Several studies have documented the high failure rate of isolated polyethylene exchange procedures, because technical problems related to the original components are left uncorrected. However, revision for wear is the simplest revision ever! Since the late 1980's the phenomena of polyethylene wear and osteolysis have been observed much more frequently when compared with earlier eras. The reasons for this increased prevalence of synovitis, progressive osteolysis, and severe polyethylene wear remain unclear. There is some association with the widespread use of both cementless and cemented modular tibial designs. Improved polyethylene attachment is the answer even if a screw, a wire, or a pin is needed. Do not abandon the modular tibia.
Abstract. Introduction. Medial fix bearing unicompartmental knee replacement (UKR) designs are consider safe and effective implants with many registries data and big cohort series showing excellent survivorship and clinical outcome comparable to that reported for the most expensive and surgically challenging medial UKR mobile bearing designs. However, whether all polyethylene tibial components (all-poly) provided comparable results to metal-backed modular components during medial fix bearing UKR remains unclear. There have been previous suggestions that all-poly tibia UKR implants might show unacceptable higher rates of early failure due to tibial component early loosening especially in high body max index (BMI) patients. This study aims to find out the short and long-term survival rate of all-poly tibia UKR and its relationship with implant thickness and patient demographics including sex,
Management of the pathologic long-head biceps tendon remains controversial. Biceps tenotomy is a simple intervention but may result in visible deformity and subjective cramping. Comparatively, biceps tenodesis is technically challenging, and has increased operative times, and a more prolonged recovery. The purpose of this study was to determine the incidence of popeye deformity following biceps tenotomy versus tenodesis, identify predictors for developing a deformity, and compare subjective and objective outcomes between those that have one and those that do not. Data for this study were collected as part of a randomized clinical trial comparing tenodesis versus tenotomy in the treatment of lesions of the long head of biceps tendon. Patients 18 years of age or older with an arthroscopy confirmed biceps lesion were randomized to one of these two techniques. The primary outcome measure for this sub-study was the rate of a popeye deformity at 24-months post-operative as determined by an evaluator blinded to group allocation. Secondary outcomes were patient reported presence/absence of a popeye deformity, satisfaction with the appearance of their arm, as well as pain and cramping on a VAS. Isometric elbow flexion and supination strength were also measured. Interrater reliability (Cohen's kappa) was calculated between patient and evaluator on the presence of a deformity, and logistic regression was used to identify predictors of its occurrence. Linear regression was performed to identify if
There is mixed evidence in the literature regarding increasing
It is probable that both genetic and environmental
factors play some part in the aetiology of most cases of degenerative
hip disease. Geneticists have identified some single gene disorders
of the hip, but have had difficulty in identifying the genetics
of many of the common causes of degenerative hip disease. The heterogeneity
of the phenotypes studied is part of the problem. A detailed classification
of phenotypes is proposed. This study is based on careful documentation
of 2003 consecutive total hip replacements performed by a single
surgeon between 1972 and 2000. The concept that developmental problems
may initiate degenerative hip disease is supported. The influences
of gender, age and body mass index are outlined. Biomechanical explanations
for some of the radiological appearances encountered are suggested.
The body weight lever, which is larger than the abductor lever, causes
the abductor power to be more important than body weight. The possibility
that a deficiency in joint lubrication is a cause of degenerative
hip disease is discussed. Identifying the phenotypes may help geneticists
to identify genes responsible for degenerative hip disease, and
eventually lead to a definitive classification.
Tibial shaft fractures require surgical stabilization preferably by intramedullary nailing. However, patients often report functional limitations even years after the injury. This study investigates the influence of the surgical approach (transpatellar vs. parapatellar) on gait performance and patient reported outcome six months after surgery. Twenty-two patients with tibial shaft fractures treated by intramedullary nailing through a transpatellar approach (TP: n=15,
Proponents of the direct anterior approach (DAA) for hip arthroplasty (THA) claim lower postoperative pain compared to the posterolateral approach (PA); however, whether that theoretical advantage results in lower opioid consumption is unclear. We sought to investigate the relationship between the DAA and PA on total 90-day predicted opioid consumption in a large cohort. Retrospective analysis identified 2,304 DAA and 6,288 PA primary THAs in patients >18 years old from February 2019 to April 2022. Ninety-day postoperative total morphine milligram equivalent (MME); in-hospital administration, discharge prescriptions, and refills within 90 days were compared between DAA and PA cohorts. Nearest-neighbor matching was performed controlling for
We sought to evaluate the early post-operative active range-of-motion (AROM) between robotic-assisted total knee arthroplasty (raTKA) and conventional TKA (cTKA). A secondary data analysis on a global prospective cohort study was performed. A propensity score method was used to select a matched control of cTKA from the same database using 1:1 ratio, based on
For all the research into arthroplasty, provision of total knee arthroplasty (TKR) services based on gender in the Australian context is yet to be explored. International literature points toward a heavily gender biased provision of TKA services, skewed away from female patients. This research has aimed to assess the current experience of Australian female patients and to explore better assessment techniques that could provide more equitable services. A retrospective cohort analysis has been conducted using pre-op PROMs data, where available, from the Australian National Joint Replacement Registry (AOANJRR), between 7 August 2018 and 31 December 2021, including: EQ VAS Health; Oxford Knee Score; joint pain; and KOOS-12. Data was adjusted for
Aims. Transfusion after primary total hip arthroplasty (THA) has become rare, and identification of causative factors allows preventive measures. The aim of this study was to determine patient-specific factors that increase the risk of needing a blood transfusion. Methods. All patients who underwent elective THA were analyzed retrospectively in this single-centre study from 2020 to 2021. A total of 2,892 patients were included. Transfusion-related parameters were evaluated. A multiple logistic regression was performed to determine whether
Obesity is associated with worse outcomes following total knee/hip arthroplasty (TKA/TKA). This study aimed to determine the feasibility of a dietitian-led low-inflammatory weight-loss program for people with obesity awaiting arthroplasty. Quasi-experimental pilot study enrolled people with obesity waitlisted for primary TKA/THA into ‘usual care’ (UC) or weight-loss (low-inflammatory diet) program (Diet). Recruitment occurred between July 2019 and February 2020 at Fairfield and Campbelltown Hospitals. Assessments at baseline, pre-surgery, time of surgery and 90-days following surgery included anthropometric measurements, patient-reported outcomes, serum biomarkers and 90-day postoperative complication rate. 97 people consented to the study (UC, n=47, mean
The aim of this study was to examine the incidence of obesity in patients undergoing primary total shoulder replacement (TSR) (stemmed and reverse) for osteoarthritis (OA) in Australia compared to the incidence of obesity in the general population. A 2017–18 cohort of 2,621 patients from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) who underwent TSR, were compared with matched controls from the Australian Bureau of Statistics (ABS) National Health Survey from the same period. The two groups were analysed according to BMI category, sex and age. According to the 2017–18 National Health Survey, 35.6% of Australian adults are overweight and 31.3% are obese. Of the primary TSR cases performed, 34.2% were overweight and 28.6% were obese. The relative risk of requiring TSR for OA increased with increasing BMI category. Class-3 obese females, aged 55–64, were 8.9 times more likely to require TSR compared to normal weight counterparts. Males in the same
Total hip arthroplasty (THA) has high rates of patient satisfaction; however patient expectations for recreational and sporting activities are not always met. Our study aimed to identify preoperative factors that predict whether patient expectations for sporting or recreational activity are met 12 months following THA. Patient reported outcome measures (PROMs) were collected prospectively from 2015-2018 at one private hospital in Sydney. Age, gender, postcode, weight, and height were recorded preoperatively. Included participants underwent primary THA by one of the investigating surgeons. Univariable and multivariable analyses were performed with an expectation fulfilment score used as the primary outcome variable. Preoperative predictor variables included:
Total hip arthroplasty (THA) is performed under general anesthesia (GA) or spinal anesthesia (SA). The first objective of this study was to determine which patient factors are associated with receiving SA versus GA. The second objective was to discern the effect of anesthesia type on short-term postoperative complications and readmission. The third objective was to elucidate factors that impact the effect of anesthesia type on outcome following arthroplasty. This retrospective cohort study included 108,905 patients (median age, 66 years; IQR 60-73 years; 56.0% females) who underwent primary THA for treatment of primary osteoarthritis in the American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database during the period of 2013-2018. Multivariable logistic regression analysis was performed to evaluate variables associated with anesthesia type and outcomes following arthroplasty. Anesthesia type administered during THA was significantly associated with race. Specifically, Black and Hispanic patients were less likely to receive SA compared to White patients (White: OR 1.00; Black: OR 0.73; 95% confidence interval [CI] 0.71-0.75; Hispanic: OR 0.81; CI, 0.75-0.88), while Asian patients were more likely to receive SA (OR 1.44, CI 1.31-1.59). Spinal anesthesia was associated with increased age (OR 1.01; CI 1.00-1.01). Patients with less frailty and lower comorbidity were more likely to receive SA based on the modified frailty index ([mFI-5]=0: OR 1.00; mFI-5=1: OR 0.90, CI 0.88-0.93; mFI-5=2 or greater: OR 0.86, CI 0.83-0.90) and American Society of Anesthesiologists (ASA) class (ASA=1: OR 1.00; ASA=2: OR 0.85, CI 0.79-0.91; ASA=3: OR 0.64, CI 0.59-0.69; ASA=4-5: OR 0.47; CI 0.41-0.53). With increased BMI, patients were less likely to be treated with SA (OR 0.99; CI 0.98-0.99). Patients treated with SA had less post-operative complications than GA (OR 0.74; CI 0.67-0.81) and a lower risk of readmission than GA (OR 0.88; CI 0.82-0.95) following THA. Race,
Aims. The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to
Our objective was to examine revision rates and patient reported outcome scores (PROMS) for cemented and uncemented primary total knee joint replacement (TKJR) at six months, one year and five years post-operatively. Patients and Methods: This matched cohort study involved secondary analyses of data collected as part of a large prospective observational study monitoring outcomes following knee replacement in Christchurch, New Zealand. Cemented and uncemented TKJR participants (n = 1526) were matched on age (± 5 years), sex and body mass index (BMI). From this larger sample, PROMS data, Oxford Knee Score and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), out to five years post-operatively were analysed for a matched subset of participants (n = 252). The average age of participants was 67.9 years (SD 9.4, range 38-94). There were no differences between cemented and uncemented cohorts on the basis of
It is anecdotally thought that a good outcome from the first of staged total hip arthroplasties (THAs) is predictive of benefit on the contralateral side. The objective was to determine whether outcome from the first THA could be used to predict outcome from the second, contralateral THA. A retrospective cohort study of consecutive patients undergoing staged THAs at a UK arthroplasty centre over 25-years (1995–2020). A control THA group was identified and matched for
Aims. This multicentre retrospective observational study’s aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following total knee arthroplasty (TKA) between the conventional Attune baseplate and its successor, the novel Attune S+, independent from other potentially influencing factors; and whether tibial baseplate design and presence of RLLs are associated with differing risk of revision. Methods. A total of 780 patients (39% male; median age 70.7 years (IQR 62.0 to 77.2)) underwent cemented TKA using the Attune Knee System) at five centres, and with the latest radiograph available for the evaluation of RLL at between six and 36 months from surgery. Univariate and multivariate logistic regression models were performed to assess associations between patient and implant-associated factors on the presence of tibial and femoral RLLs. Differences in revision risk depending on RLLs and tibial baseplate design were investigated with the log-rank test. Results. The conventional and novel Attune baseplates were used in 349 (45%) and 431 (55%) patients, respectively. At a median follow-up of 14 months (IQR 11 to 25), RLLs were present in 29% (n = 228/777) and 15% (n = 116/776) of the tibial and femoral components, respectively, and were more common in the conventional compared to the novel baseplate. The novel baseplate was independently associated with a lower incidence of tibial and femoral RLLs (both regardless of
Aims. Femoral component anteversion is an important factor in the success of total hip arthroplasty (THA). This retrospective study aimed to investigate the accuracy of femoral component anteversion with the Mako THA system and software using the Exeter cemented femoral component, compared to the Accolade II cementless femoral component. Methods. We reviewed the data of 30 hips from 24 patients who underwent THA using the posterior approach with Exeter femoral components, and 30 hips from 24 patients with Accolade II components. Both groups did not differ significantly in