Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_17 | Pages 9 - 9
11 Oct 2024
Zace P Maas Z McIntyre R Khan Z Bailey O
Full Access

Increasing the accuracy of information provided through X-Rays maximises pre-operative planning. Aim of this project is to determine the necessity of calibration probes that would improve the accuracy of pre-operative templating. This is a retrospective study involving leg length and pelvis X-Rays performed across the NHS Lanarkshire from 01/03/2023 until 31/04/2024. A total of 87 leg length X-Rays were identified, 18 had a calibration probe present. Leg length was measured on each and the X-Rays were calibrated against the existing probe. In 66.7% of cases there was a major leg length discrepancy of over 2cm between the pre-calibrated and post-calibrated X-Rays. Pelvic X-Rays of 80 patients that underwent total hip replacement were reviewed. Preoperative templating was compared to the implants inserted. An average of 1.94 discrepancy in the size of the acetabular implant was identified whilst in 30 cases the size of the femoral stem was incorrect by at least 1 size. Magnification of 119.7% on X-Rays was found to provide the most accurate templating. Seventy seven cases of pelvic X-Rays before and after hip hemiarthroplasty were also reviewed. The implant head was templated incorrectly in 74% of cases and the stem in 51%. It was identified that pelvic X-Ray magnification of 121.7% would provide the most accurate results. X-Rays with no calibration probes provide inaccurate measurements leading to faulty preoperative planning. Standardised use of a calibration sphere is strongly suggested and whenever that is not available, we suggest magnification of 121%


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 4 - 4
10 Oct 2023
Russell H Tinning C Raza A Duff S Preiss RA
Full Access

The Thompson hemiarthroplasty is a common treatment option for acute neck of femur fractures in the elderly population. Our department noted a significant number of patients returning with thigh pain, radiographic loosening and femoral osteolysis following cemented implantation of the titanium alloy version of the Thompson hemiarthroplasty. We are not aware of any previous reports documenting complications specific to the titanium Thompson implant and a retrospective cohort study was therefore initiated following clinical governance approval. 366 titanium alloy Thompson prostheses were implanted for hip fracture treatment between 2017 and 2020. As of February 2023, 6 of these have been revised at our hospital. 5 were revised for symptomatic femoral osteolysis and 1 presented with an acute periprosthetic fracture. All revised cases were determined to be aseptic. 32 living patients were excluded from recall on compassionate grounds due to permanent nursing home residence. 47 living patients were identified of which 33 attended for xray. 28 deceased and/or nursing home resident patients who had pelvis x-rays in the previous 12 months were also included in the analysis. Including the 6 index hips already revised, a total of 61 hip xrays were analysed, of which 19 hips (31.1%) showed radiographic evidence of femoral osteolysis or loosening. We conclude that there is a concerning incidence of femoral osteolysis and implant loosening associated with the titanium Thompson implant. We have discontinued use of the implant and reported our experience to the MHRA. We encourage other Scottish Health-Boards who use this implant to consider enhanced follow-up


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_14 | Pages 7 - 7
10 Oct 2023
Chambers M Madeley N
Full Access

Stable Weber B fractures are typically treated non-operatively without complications but require close monitoring due to concerns over potential medial deltoid ligament injuries and the risk of delayed talar shift. Following recent evidence suggesting this is unlikely, a functional protocol with early weight bearing was introduced at Glasgow Royal Infirmary (GRI) following a pilot audit. This study aims to evaluate the risk of delayed talar shift in isolated Weber B fractures managed with functional bracing and early weight-bearing, particularly if signs of medial ligament injury are present. We conducted a retrospective review of 148 patients with isolated Weber B fractures without talar shift at presentation that were reviewed at the virtual fracture clinic at our institution between July 2019 and June 2020. The primary outcome was the incidence of delayed talar shift. Secondary outcomes were other complications and adherence to protocol. 48 patients had medial signs present and of these 1 (2%) showed possible talar shift on X-rays at 4 weeks, and was kept under review. This patient had a normal medial clear space at 3 months. No patients with medial signs not documented (n=19) or not present (n=81) had delayed talar shift. 10% of patients (n=15) had at least 1 complication: delayed union (n=2); non-union (n=3); ongoing pain (n=14). Functional bracing with early weight-bearing is a safe, effective protocol for managing isolated Weber B fractures without initial talar shift. This study concludes that the risk of delayed talar shift is low in all patients, with or without medial signs


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_6 | Pages 11 - 11
1 Jun 2022
Oosthuysen W McQuarrie K Crane E Madeley N Kumar CS
Full Access

The surgical care of extra-articular distal tibial fractures remains controversial. This study looks at the radiological outcomes of distal tibial fractures treated with either a direct medial or anterolateral plate, with or without plating of the fibula, to assess the outcome and complications associated with these 2 approaches. This is a retrospective review of 80 patients with distal tibial extra-articular fractures, treated with an open reduction and plating, between 2008 and 2019 at Glasgow Royal Infirmary. Case notes and x-rays were reviewed. Of those tibial fractures fixed with only a medial plate, 78% united (28/36), 5% (2/36) had a non-union and 17% (6/36) a malunion. In the group treated with a combination of medial tibial and fibular plating, the figures were; 71% (15/21), 19% (4/21) and 10% (2/21). However, in the group treated with anterolateral plating of the tibia alone, only 53% (8/15) united, with a 20% (3/15) non-union and 13% (2/15) malunion rate. Additionally in this group, there were 2 patients (13%) with loss of fracture reduction within the first two months of fracture fixation, requiring revision surgery. Interestingly, of the 8 patients treated with anterolateral tibial and fibular plating, 88% (7/8) showed full union and only one (12%) had a non-union, with no malunions is this group. It would appear that medial tibial and a combination of medial tibial and fibular plating, have superior outcomes compared to anterolateral plating. Results suggest, if anterolateral plating is done, this should be augmented by fixation of the fibular fracture as well


Bone & Joint Open
Vol. 5, Issue 2 | Pages 117 - 122
9 Feb 2024
Chaturvedi A Russell H Farrugia M Roger M Putti A Jenkins PJ Feltbower S

Aims

Occult (clinical) injuries represent 15% of all scaphoid fractures, posing significant challenges to the clinician. MRI has been suggested as the gold standard for diagnosis, but remains expensive, time-consuming, and is in high demand. Conventional management with immobilization and serial radiography typically results in multiple follow-up attendances to clinic, radiation exposure, and delays return to work. Suboptimal management can result in significant disability and, frequently, litigation.

Methods

We present a service evaluation report following the introduction of a quality-improvement themed, streamlined, clinical scaphoid pathway. Patients are offered a removable wrist splint with verbal and written instructions to remove it two weeks following injury, for self-assessment. The persistence of pain is the patient’s guide to ‘opt-in’ and to self-refer for a follow-up appointment with a senior emergency physician. On confirmation of ongoing signs of clinical scaphoid injury, an urgent outpatient ‘fast’-wrist protocol MRI scan is ordered, with instructions to maintain wrist immobilization. Patients with positive scan results are referred for specialist orthopaedic assessment via a virtual fracture clinic.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 8 - 8
1 Feb 2020
Sciberras NC Rowland DJ
Full Access

Elevated fat pads on a paediatric elbow radiograph may represent an intraarticular fracture. If no obvious fracture is visible, the injury may be treated with a collar and cuff until discomfort resolves. In some centres these patients are discharged directly from A&E, easing the load on fracture clinics and reducing the number of visits required by the patient. A retrospective study was carried out to review patient journey for children referred to clinic with elevated fat pads only and to investigate whether such a protocol could be established locally. Notes for all children attending fracture clinic in May 2018 were reviewed. X-rays for patients with any elbow injury were then reviewed. Patients with raised fat pads only were included in the study. Outcome following clinic review was recorded. 818 patients (315 new referrals) attended 15 clinics. 31 were referred with raised fat pads only. Mean age was 7.7 years with mean time to clinic of 4 days. 74.2% required no further treatment and were discharged at first clinic appointment. 8 patients were kept in cast for another 1–2 weeks due to parental apprehension, patient apprehension or patient being uncomfortable without cast. None of our patients required surgical intervention or re-attended following discharge. This study showed that patients with raised fat pads only can be treated with collar and cuff, analgesia and discharged from A&E with an advice leaflet. This would reduce the number of patients unnecessarily attending clinics thereby reducing patient distress and enabling more efficient use of clinic appointments


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 477 - 477
1 Sep 2012
Kantak A Patnaik S Lal M Nadjafi J
Full Access

Objective. Delayed radiographs are routinely done to help in diagnosis of occult scaphoid fractures. Our aim was to determine the diagnostic value of these late x-rays. Methods. This is a radio-diagnostic study. We prospectively reviewed radiographs of 67 patients with injury to their wrists who presented with anatomical snuff box to the accident and emergency department.5 patients showed up a fracture of the scaphoid on trauma x-rays and they were excluded from the study. All patients had a radiograph on day of presentation as well as a delayed radiograph at a later date. The radiographs were standardized to include 4 scaphoid views. All the radiographs were reported independently by a consultant radiologist (JN) and a consultant orthopaedic surgeon (ML). Results. 62 radiographs of 42 males and 20 females with an average age of 25.91 were examined. The two sequential radiographs were taken at an average delay of 10.23 days. There was no difference of opinion between the radiologist and the orthopaedic surgeon with regards to reporting. Only one of the late radiographs showed up a fracture of the proximal pole. Rest of the x-rays failed to detect any bony injury. Conclusion. If a fracture is not visible on first day it is difficult to visualize the fracture in delayed x-rays and a strong clinical suspicion should be supplemented with a more specific investigation like a bone scan or MRI scan. We present our data with an up to date review of literature


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 8 - 8
1 May 2019
Moriarty P Wong L Kearney D Harty J
Full Access

Revision hip arthroplasty presents a challenge in the setting of femoral bone loss. Tapered stems are susceptible to subsidence which leads to leg length inequality, hip instability and may necessitate repeat femoral revision surgery. The purpose of this study was to compare radiographic outcomes in two modular tapered revision systems with different distal stem geometries. We sought to establish the minimum postoperative stem bi-cortical contact length that predicts subsidence for tapered stems. This study examined revision total hip arthroplasties between 2009 and 2016 in a European university affiliated major trauma center. Modular stem A has a taper of 3 degrees whereas modular stem B has a taper of 2 degrees. Radiologic assessment compared x-rays at two time points: immediately post-surgery and most recent x-ray available at a minimum follow up of two years. Leg length discrepancy, subsidence and postoperative bi cortical contact was assessed. Descriptive summary statistics calculated clinical factors (i.e. age, gender, Paprosky classification). 122 arthroplasties were completed. Complete data was available for 112. Revisions were carried out for Paprovski grade 3a/ 3b femoral deficits. Post-operative bi-cortical contact of the proximal stem < 20mm was associated with higher subsidence rates (P = 0.047). Subsidence rates for implant A and B system were 4.27mm (0.12–25.62mm) and 3.43 mm (0.3–11.1 mm) respectively. Significant subsidence was noted in 9.8% (n=8) in implant A and 5.2%(n=2) in implant B. We conclude that immediate postoperative bi-cortical stem contact of <20mm was associated with significantly higher subsidence rates in this study


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 82 - 82
1 Sep 2012
Benjamin G Zadegan F Hannouche D Nizard R
Full Access

Limb length disparity is a frequent complication after hip surgery inducing many surgeon-patients conflicts. To date no study has been able to precisely quantify such limb length disparity. EOS® system, currently validated to measure lower limb parameters, allows from two bi-dimensional numerical orthogonal radiographies in standing position to obtain a tri-dimensional reconstruction of lower limbs. A computerized system achieves the parameters calculation. The aim of this study is to precisely measure the limb length disparities and the other hip parameters following total hip arthroplasty surgical procedure, by using a standard X-rays and using EOS® three-dimensional reconstructions. Twenty-eight patients programmed for total hip arthroplasty have been included (i.e. thirty lower limbs). Two independent performers have carried out twice the measures either on standard X-rays and using three-dimensional reconstructions of the lower limb disparities prior and after the surgical procedure. The inter and intra-observer reproducibility for the measure of the lower limb disparities have been of the EOS® measures have been respectively of 0.854 and 0.865 and for the standard X-rays of 0.717 and 0.726. Mean length disparity observed was before Total Hip Arthroplasty of −0.328 cm (0.705; −1.266/0.530) and was of 0.088 mm (1.326; −1.635/0.632) after. We are able to decrease the lower limbs disparity in 69.1% and for the average of 0,416cm. Using EOS® system has allowed assessing with greater precision the possibility to restore equal lower limb length. This assessment has permitted introducing a new planning procedure including EOS® imaging associated to the fusion of the prosthetic tri-dimensional image in order to achieve adequate lower limb length


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_1 | Pages 3 - 3
1 Jan 2019
Hughes LD Chamberlain KA Sloan A Choudry Q Robinson H
Full Access

MHRA guidance for patients with metal on metal hip replacements (MOM) was provided in 2012 and updated in 2017 to assist in the early detection of soft tissue reactions due to metal wear debris. A large number of metal on metal hip replacements were undertaken at our trust. A program of recall for all patients with metal on metal hip replacements was undertaken and MHRA guidelines implemented. Identification and recall of all patients from 2001 with MOM hip replacements using theatre logs, patient records and consultant log books. Two consultant review of X-rays and patient records. Postal questionnaires and GP requests for cobalt & chromium blood tests. Two consultant led MOM review clinics undertaken with metal artefact reduction scans (MARS) performed following consultation in 2017. 674 patients, 297 available for review. 59 refused follow up. 87 moved out of area, 36 untraceable, 26 not MOM, 147 RIP, 22 already revised. From 297 patients 126 female, 171 male, age range 39 – 95 yrs. 126 resurfacing, 171 MOM THR. 26 patients with elevated metal ions, MARS performed of which 17 positive, 9 negative. Of 17 positive scans 10 patients asymptomatic, 7 waiting revision. A time consuming effort and additional resource was needed and supported by the trust. From 297 hips 17 positive MARs were identified (5.7%). A new database registry has been developed to track MOM patients, clinics set up for ongoing follow up with radiological protocols for imaging. An arthroplasty advanced nurse practitioner (ANP) is now trained reviewing patients independently


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 322 - 322
1 Sep 2012
Bock P Pittermann M
Full Access

Background. Acquired flatfoot deformity goes ahead with a partial or complete rupture and thus insufficiency of the tibialis posterior tendon. We present the results of flexor digitorum longus transfer and medial displacement calcaneal osteotomy to reconstruct the acquired deformity. Material & Methods. Twenty two patients (24 feet) with an average age of 58 (36–75) years were operated on for acquired flexible flatfoot deformity. Two patients had a bilateral procedure. Patients were seen pre-and postoperatively in order to evaluate following parameters: AOFAS hindfoot score, visual analogue scale for pain (0–10), the tarsometatarsal angle on lateral and ap standing x-rays, the cuneiform heights and talocalcaneal angle on lateral standing x-rays and subjective postoperative satisfaction score (1-worst to 5-best). Average time of follow-up was 24.7 months (12–48). Results. The AOFAS hindfoot score could be increased from 46.4 to 89.5 points, the visual analogue scale for pain decreased from 6.6 to 1.1. The average satisfaction score was 4.5 points with one patient scoring 2 and another one scoring 3. All the other patients scored either 4 or 5. All radiological parameters could be improved. Following complications were seen: one recurrence, two patients with irritation of the sural nerve, one patient with hypesthesia of the big toe. The calcaneal screws had to be removed in 3 patients. Conclusion. Flexor digitorum longus transfer together with medial displacement calcaneal osteotomy gave satisfactory results for the treatment of acquired flatfoot deformity. All radiologic parameters were improved


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 162 - 162
1 Sep 2012
Kralinger F Voigt C Platz A Schaser K Leung F Babst R Majewski M Stöckle U Käch K
Full Access

Introduction. A review of the literature showed a discrepancy between biomechanical and clinical studies on fracture fixation failure in patients with poor bone quality. The objective of the present study is to assess the influence of local bone status on complications after surgical treatment of proximal humerus fractures. Methods. A prospective cohort study was initiated in 2007. The inclusion criteria were closed displaced fractures of the proximal humerus, primary fracture treatment with a Philos plate, patients aged 50 to 90, normal pre-trauma function of both shoulders in accordance to age, and monotrauma. There was active follow-up for one year with radiological assessment at clinical centers from four countries. Bone quality at the proximal humerus was determined preoperatively for the contralateral side of the fracture by CT scan, and at the contralateral radius within six weeks post-surgery by DXA. The occurrence of complications was monitored up to one year post-surgery. Independent x-ray evaluation and final classification of all complications will be performed at the end by a study review board using anonymous data and x-rays. Preliminary Results. 157 patients, 127 female (79%) met the inclusion criteria. Their mean age at time of surgery is 69 (range 50–89). 119 patients (100%) attended the 1-year follow-up assessment, 64 (96%) the one at 3 months, and 148 (99%) the 6 week follow-up examination. According to the WHO criteria, 107 patients (71%) suffered from either osteopenia or osteoporosis, while 43 patients (29%) had a normal T-score. The overall reported complication rate was 39%. However, the number of intraoperative complications was 0.6%, bone/fracture complications 19.1%, implant complications 15.3%, and general complications 14.6%. Discussion. Fixation of proximal humerus fractures with Philos plates in elderly people with osteoporotic bone is associated with a high rate of fixation failure. Final results will be reported after x-rays, local BMD (CT- based) and complications assessment have been conducted


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 19 - 19
1 May 2015
Penn-Barwell J Bennett P Mortiboy D Fries C Groom A Sargeant I
Full Access

The aim of this study was to characterise severe open tibial shaft fractures sustained by UK military personnel over 10-years of combat and to determine the infection rate and factors that influence it. The UK military Joint Theatre Trauma Registry was searched and X-rays, clinical notes and microbiological records were reviewed for all patients. One hundred GA III open tibia fractures in 89 patients were identified. Three fractures were not followed up for 12-months and were therefore excluded. Twenty-two (23%) of the remaining 97 tibial fractures were complicated by infection requiring surgical treatment, with S. aureus being the causative agent in 13/22 infected fractures (59%). Neither injury severity, mechanism, the use of an external fixator, the need for vascularised tissue transfer or smoking status were significantly associated with infection. Bone loss was significantly associated with subsequent infection (p<0.0001). Most infection in combat open tibia fractures is caused by familiar organisms i.e. S. aureus. The use of external fixators to temporarily stabilise fractures is not associated with an increased risk of subsequent infection. While the overall severity of a casualty's injuries was not associated with infection, the degree of bone loss from the fracture was


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 48 - 48
1 Apr 2013
Chiarello E Tedesco G Cadossi M Capra P Hoque M Luciani D Giannini S
Full Access

Introduction. In elderly patients, the incidence of a second fracture in the contralateral hip within 2 years of a femoral neck fracture (FNF), ranges from 7 to 12%. Hypothesis. We want to evaluate the safety and efficacy of the Prevention Nail System (PNS), a titanium screw with a hydroxyapatite-coated thread, developed to prevent contralateral FNFs in severe osteoporotic patients. Materials and methods. From September 2008 to May 2012, 80 osteoporotic FNF patients (Tscore<;−2.5) were recruited. Patients received standard care for the fractured hip and were randomized to receive either the PNS (Group A), or nothing (Group B) in the contralateral hip. DXA, CT and X-rays of the reinforced hip were scheduled at 3, 12 and 24 months postoperative. Results. Average follow-up was 26 months. Twenty-one patients reported secondary falls. Group A: 13 patients with 9 osteoporotic fractures (3 contralateral subtrochanteric); Group B: 6 patients with a second osteoporotic fracture (3 contralateral FNF). CT scans showed no radiolucencies or PNS loosenings. Discussion and Conclusion. In Group A the hip fractures had a spiroid rime beginning from the lateral cortical entry hole; FNFs were fixed with the PNS plate. The secondary fracture occurred, in Group A patients, within a month of hospital discharge; this could be due to the implantation device drill which is wider than the body of the screw. PNS is well tolerated but subtrochanteric fractures may occur in case of difficult insertion of the device


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 275 - 275
1 Sep 2012
Dawoodi A Perera A
Full Access

Background. Metatarsus adductus is the most common forefoot deformity. Variable prevalence values were reported in literature using different techniques in different populations. Numerous radiological measurements have been proposed to assess this deformity with a paucity of studies reporting the reliability of these methods. The metatarsus adductus angle was shown to correlate with the severity of hallux abductovalgus in normal feet and preselected populations of juvenile hallux valgus. Materials & Methods. Weight bearing dorsoplantar radiographs of 150 feet were examined for 5 angles commonly used in assessing metatarsus adductus: angle between the second metatarsus and the longitudinal axis of the lesser tarsus (using the 4th or 5th metatarso-cuboid joint as a reference), Engel's angle and modified angle's angle. The prevalence of metatarsus adductus was assessed according to published criteria for different techniques. Inter and intra-observer reliabilities of these angles were evaluated on 50 X-rays. Linear regression tests were used to assess the correlation between hallux valgus and different angles used in assessing metatarsus adductus. Results. Intraclass correlation coefficients were high for intra- as well as inter-observer reliability for the 5 angles tested. Prevalence of metatarsus adductus ranged (45–70%) depending on the angle used in the same population. Only the metatarsus adductus angle using the 4th metatasro-cuboid joint as a reference demonstrated significant correlation between metatarsus adductus and hallux abductovalgus angles. Conclusions. Five techniques commonly used in assessing metatarsus adductus demonstrated high inter and intra-observer reliability values. Prevalence of metatarsus adductus and the correlation between the severity of this deformity and hallux valgus angle is sensitive to the assessment method


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 198 - 198
1 Sep 2012
Kon E Vannini F Marcacci M Buda R Filardo G Cavallo M Ruffilli A Giannini S
Full Access

Osteocondritis dissecans (OCD) is a relatively common cause of knee pain. Ideal treatment is still controversial. Aim of this exhibit is to describe the outcomes of 5 different surgical techniques in a series of 63 patients. 63patients (age 22.5±7.4 years) affected by OCD of the femoral condyle (45 medial and 17 lateral) were treated by either osteochondral autologous transplantation, autologous chondrocyte implantation with bone graft, biomimetic nanostructured osteochondral scaffold (Maioregen) implantation, bone-cartilage paste graft or bone marrow derived cells transplantation “one-step” technique. Patient evaluation included IKDC score, eq-vas score, X-Rays and MRI preoperatively and at follow-up. Global mean IKDC improved from pre-operative 40.1±14.6 to 77.2±21.3 (p<0.0005) at mean 5.3±4.7 years follow-up, while eq-vas improved from 51.7±17.0 to 83.5±18.3(p<0.0005). No influence of age, size of the lesion, length of follow-up and associated surgeries on the result was found. No differences were found between the results obtained with different surgeries except a slight tendency of better improvement in the result following autologous chondrocyte implantation (p<0.01). Control MRI evidenced a satisfactory repair of cartilaginous layer and subchondral bone. The techniques described were effective in providing good clinical and radiographic results in the treatment of OCD and confirmed the validity of autologous chondrocyte implantation over time. Newer techniques such as Maioregen implantation and “one-step” base on different rationales, the first relying on the characteristics of the scaffold and the second on the regenerative potential of mesenchymal cells. Both of them have the advantages to be minimally invasive surgeries and to require a single operation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 543 - 543
1 Sep 2012
Mounsey E Dawe E Golhar A Hockings M
Full Access

Introduction. High Tibial Osteotomy has become an increasingly popular management option for patients with painful medial compartment osteoarthritis. The Fujisawa method used to calculate the angle of correction is well-documented but there have been no studies to look at the reliability and accuracy of web-based systems to calculate this angle. Patients and Methods. Patients undergoing valgus high tibial osteotomy between October 2004 and February 2010 who had full-length lower-limb views on the Picture Archiving and Communications System (PACS). The Fujisawa angle and length of osteotomy were calculated by the surgeon and two Orthopaedic registrars who had been appropriately trained. Results. Thirty X-rays were reviewed in 28 patients. Mean difference between measurements was 0.43 mm (SD 2.45) There was a statistically significant correlation between all three raters (P < 0.001). The greatest correlation was between the Consultant and the more senior trainee (r=0.86) with the lowest correlation between the Consultant and the more junior trainee (r=0.70). Concordance correlation coefficient between raters varied from 0.81 to 0.63. Bland-Altman plot of agreement between the Consultant and senior trainee was excellent showing only two values lying outside 1.96 SD. Discussion. Comparison of measurements between raters showed increased accuracy with greater experience of the measurement technique. Despite this we show high correlation between raters with measurement accuracy of all raters found within clinically acceptable limits (< 1mm). Conclusion. Measurement of tibial osteotomy using the fujisawa method on a web-based X-ray interpretation system is accurate and reliable


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 255 - 255
1 Sep 2012
Moroni A Hoque M Micera G Sinapi F Calbucci L Maccagnan E Giannini S
Full Access

Introduction. Metal-on-metal hip resurfacing (MOMHR) is a good surgical indication for young active patients. However, it cannot be used in patients with an excessively short femoral head/neck. To address these cases, a new surgical technique has been developed comprising femoral head augmentation using impacted morcellized bone grafts. Methods. 32 osteoarthritis patients who had severe congenital insufficiency of the femoral head/neck were treated with MOMHR combined with femoral head augmentation. Mean patient age was 49 ± 9 years (18–66). The required amount of augmentation was calculated on preoperative X-rays and confirmed during surgery. Using specially designed instrumentation, bone chips produced while reaming the socket and trimming the head were impacted onto the head to achieve the desired reconstruction and lengthening. Finally, the femoral component was cemented. Results. Mean head lengthening was 12 ± 2mm. Mean follow-up was 4.2 years (3–6). Mean preoperative Harris hip score was 58, increasing to 95 at follow-up (p<0.05). Mean leg lengthening was 2.2cm (p=0.001). In all Gruen zones, bone mineral density (BMD) decreased during the first 3 months. At 2 years, in zone 1, mean BMD increased to 96.8% (p=0.009) and to 102.1% in zone 7 (p=0.05). A correlation was found between valgus positioning of the femoral components and increased BMD (p=0.005). To date, only 1 patient has been revised due to socket loosening. Discussion and conclusions. This bone grafting technique expands the use of MOMHR to patients with severe deficiencies of the femoral head, thereby leading to a more anatomical reconstruction with a full recovery of function and BMD of the proximal femur


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 556 - 556
1 Sep 2012
Heikenfeld R Listringhaus R Godolias G
Full Access

Aim. The purpose of this study was to evaluate the results after arthroscopic reconstruction of isolated SSP lesions. Does double row repair in smaller lesions lead to better results and a lower retear rate?. Method. 80 patients with an isolated full thickness SSP tear were divided into 2 groups. Group 1 (27 men, 13 Frauen, average age 57 y.) was repaired using a single row technique with 2 anchors (Mitek Fastin) with arthroscopic Mason-Allen stiches. Group 2 was repaired using a double row technique using 1 medial anchor (Mitek Fastin) and 2 lateral anchors (Versalok). PreOP an ultrasound and MRI was obtained as well as standard x-rays (a.p., outlet-view, transaxial). Included to this study were only patients matching the following criteria: intraoperative cartilage lesions ≤ Outerbridge Grade2, fatty degeneration ≤ Goutallier Grade 2, ap extent of the tear < 2,5 cm. Prospective follow up after 6, 12 and 24 months using UCLA and Constant Score as well as MRI at last follow up. Results. 37 patients in group 1 and 36 patients in group 2 were completely evaluated. Both groups showed improvement in Constant Score from 49,3 to 89,4 in group 1 (single row) compared to 47,6 and 90,7 in group 2 (Double Row). MRI at last follow up showed 4 retears in the single row group and 3 retears in the double row group. 1 shoulder in the double row group needed revision due to a loose anchor. Discussion. We could not find any significant difference between clinical results and retear rate using a single or double row suture anchor configuration in isolated full thickness SSP tears


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 262 - 262
1 Sep 2012
Buchanan J Fletcher R Linsley P
Full Access

Aims. Will Hydroxyapatite hip (HA) arthroplasty associated with ceramic bearings produce uncomplicated function in younger, active patients’ The incidence of aseptic loosening, dislocation and broken implants has been particularly investigated. Debris disease from plastic debris contributes to aseptic loosening. Hard-Hard bearings should obviate this problem. Metal-metal will release ions which might be deleterious. Experience with metal-metal resurfacing has high lighted problems including pseudo-tumours. Ceramic bearings may fracture but otherwise appear free of complications. Methods. This is a study extending over 19 years of 626 HA hip arthroplasties with ceramic bearings. Annual review using Harris Hip Score to assess pain and function and X-rays to check osseointegration has been performed. Alumina ceramic was inserted in 467 hips. The newer Zirconia Toughened Alumina (ZTA) has been inserted in 169 hips. There are 118 hips still under review at 10 or more years. Results. Aseptic loosening is unusual (one stem, two acetabulae (3 of 1252 components, 0.24%) Failure from mal-orientation with repeated dislocation occurred in six hips (0.96%). Three alumina heads (0.48%) and two alumina liners (0.32%) broke. There has been no failure of ZTA ceramic. No patients have thigh pain. Osteolysis and debris disease have not arisen. Harris Hip Scores show 91.2% scoring over 90 or 100. Lower scores mostly relate to other joint and medical problems. Conclusions. Assessments confirm that patients remain well. Aseptic loosening of HA hips is rare at 0.24%. Failure from broken alumina components is unusual. Alumina has now been superseded by ZTA for implantation. Ceramic on ceramic is a reliable selection for bearing surfaces in patients of any age and either sex