Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 8 - 8
1 Sep 2021
Abdalla M Nyanzu M Fenner C Fragkakis E Ajayi B Lupu C Bishop T Bernard J Willis F Reyal Y Pereira E Papadopoulos M Crocker M Lui D
Full Access

Introduction. Spine is a common site for haematological malignancies. Multiple myeloma affects the spine in 70% of cases. New guidelines were published in 2015 to help manage spinal haematological malignancies. Despite neural compression or spinal instability, instrumentation of the spine should be avoided. Surgery carries significant risks of wound complications and more importantly delaying the definitive chemotherapy and radiotherapy. Cement augmentation and bracing for pain and prevention of deformity is key to the new strategies. We aimed to evaluate the different treatment modalities adopted in the spine unit at St George's hospital for spinal haematological malignancies. We compared our practice to the current guidelines published in 2015. Methods. Retrospective review of all spinal haematological malignancy patients who were discussed in the spinal MDT and managed through the spine unit at St George's hospital in the period between April 2019 and February 2021. We analysed the demographics of the patients treated in this period and compared the management modalities adopted in the unit to the current British haematological guidelines. Results. 139 patients were included in this study, 61.9% of them were male. 70 cases came through the MSCC pathway. 15 patients had their spinal involvement in the lumbar spine only below the conus. The Bilsky Grades of the other 124 cases were B0: 35.97 % 1a: 4.31%%, 1b: 7.19%, 1c: 3.59%, 2: 5.75% 3: 32.37%. 43 patients (30.9 %) had neurological deficits on presentation. 70 cases were treated conservatively (50.35%), 21 were treated with brace only (15.1%), 25 had BKP (17.98%) and 23 were treated with instrumentation (16.54%). The number of instrumented cases was small and trending down and cement augmentation and bracing were more frequently chosen for these patients. This comes in accordance to the British haematological guidelines. Conclusion. Utilising BJH 2015 guidelines we have reduced our instrumented operative case load. There is a higher percentage of BKP and Bracing in accordance to the algorithm


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_15 | Pages 10 - 10
1 Oct 2014
Cheung KMC Cheung JPY Kwan K Ferguson J Nnadi C Alanay A Yazici M Demirkiran G Helenius IJ Akbarnia B
Full Access

The magnetically controlled growing rod (MCGR) system allows growth maintenance without the risk of anaesthesia, implant and wound complications associated with repeated surgeries. This is a medium-term report of the complications of MCGR from a multicentre study. Twenty-six patients from 6 spine institutes that are part of a multicentre study with prospectively collected data of minimum 24 months follow-up were assessed. Pre-operative, immediate post-operative and most recent spine radiographs were reviewed to measure the Cobb angle and the rod lengthening distance. The causes and any associated risk factors for re-operations were examined. Eleven patients required re-operation within the follow-up period, with a mean time to re-operation of 17 months after the initial surgery. Five were due to failure of rod distractions; 3 were due to failure of proximal foundation implants; 2 were due to rod breakage; and one case of superficial wound infection with failure of proximal fixation. Proximal junctional kyphosis occurred in 5 patients. Three had proximal anchor dislodgement and all five constructs were revised. This is the largest series with the longest follow-up to date. Our series show that the perception that using MCGR may reduce the frequency of re-operations may not be entirely true. This is the first report to examine the need for re-operation after MCGR implantation, and highlights the inherent risks of any surgical treatment in this group of patients despite the advantages of this new implant. Longer-term studies and comparisons with traditional growing rods are required


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1375 - 1383
3 Oct 2020
Zhang T Sze KY Peng ZW Cheung KMC Lui YF Wong YW Kwan KYH Cheung JPY

Aims

To investigate metallosis in patients with magnetically controlled growing rods (MCGRs) and characterize the metal particle profile of the tissues surrounding the rod.

Methods

This was a prospective observational study of patients with early onset scoliosis (EOS) treated with MCGRs and undergoing rod exchange who were consecutively recruited between February 2019 and January 2020. Ten patients were recruited (mean age 12 years (SD 1.3); 2 M:8 F). The configurations of the MCGR were studied to reveal the distraction mechanisms, with crucial rod parts being the distractable piston rod and the magnetically driven rotor inside the barrel of the MCGR. Metal-on-metal contact in the form of ring-like wear marks on the piston was found on the distracted portion of the piston immediately outside the barrel opening (BO) through which the piston rod distracts. Biopsies of paraspinal muscles and control tissue samples were taken over and away from the wear marks, respectively. Spectral analyses of the rod alloy and biopsies were performed to reveal the metal constituents and concentrations. Histological analyses of the biopsies were performed with haematoxylin and eosin staining.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 519 - 523
1 Apr 2020
Kwan KYH Koh HY Blanke KM Cheung KMC

Aims

The purpose of this study was to evaluate the incidence and analyze the trends of surgeon-reported complications following surgery for adolescent idiopathic scoliosis (AIS) over a 13-year period from the Scoliosis Research Society (SRS) Morbidity and Mortality database.

Methods

All patients with AIS between ten and 18 years of age, entered into the SRS Morbidity and Mortality database between 2004 and 2016, were analyzed. All perioperative complications were evaluated for correlations with associated factors. Complication trends were analyzed by comparing the cohorts between 2004 to 2007 and 2013 to 2016.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1187 - 1200
1 Sep 2018
Subramanian T Ahmad A Mardare DM Kieser DC Mayers D Nnadi C

Aims

Magnetically controlled growing rod (MCGR) systems use non-invasive spinal lengthening for the surgical treatment of early-onset scoliosis (EOS). The primary aim of this study was to evaluate the performance of these devices in the prevention of progression of the deformity. A secondary aim was to record the rate of complications.

Patients and Methods

An observational study of 31 consecutive children with EOS, of whom 15 were male, who were treated between December 2011 and October 2017 was undertaken. Their mean age was 7.7 years (2 to 14). The mean follow-up was 47 months (24 to 69). Distractions were completed using the tailgating technique. The primary outcome measure was correction of the radiographic deformity. Secondary outcomes were growth, functional outcomes and complication rates.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1204 - 1209
1 Sep 2017
Fawi HMT Saba K Cunningham A Masud S Lewis M Hossain M Chopra I Ahuja S

Aims

To evaluate the incidence of primary venous thromboembolism (VTE), epidural haematoma, surgical site infection (SSI), and 90-day mortality after elective spinal surgery, and the effect of two protocols for prophylaxis.

Patients and Methods

A total of 2181 adults underwent 2366 elective spinal procedures between January 2007 and January 2012. All patients wore anti-embolic stockings, mobilised early and were kept adequately hydrated. In addition, 29% (689) of these were given low molecular weight heparin (LMWH) while in hospital. SSI surveillance was undertaken using the Centers for Disease Control and Prevention criteria.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 507 - 515
1 Apr 2018
Nnadi C Thakar C Wilson-MacDonald J Milner P Rao A Mayers D Fairbank J Subramanian T

Aims

The primary aim of this study was to evaluate the performance and safety of magnetically controlled growth rods in the treatment of early onset scoliosis. Secondary aims were to evaluate the clinical outcome, the rate of further surgery, the rate of complications, and the durability of correction.

Patients and Methods

We undertook an observational prospective cohort study of children with early onset scoliosis, who were recruited over a one-year period and followed up for a minimum of two years. Magnetically controlled rods were introduced in a standardized manner with distractions performed three-monthly thereafter. Adverse events which were both related and unrelated to the device were recorded. Ten children, for whom relevant key data points (such as demographic information, growth parameters, Cobb angles, and functional outcomes) were available, were recruited and followed up over the period of the study. There were five boys and five girls. Their mean age was 6.2 years (2.5 to 10).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 627 - 631
1 May 2009
Khurana A Guha AR Mohanty K Ahuja S

We reviewed 15 consecutive patients, 11 women and four men, with a mean age of 48.7 years (37.3 to 62.6), who between July 2004 and August 2007 had undergone percutaneous sacroiliac fusion using hollow modular anchorage screws filled with demineralised bone matrix.

Each patient was carefully assessed to exclude other conditions and underwent pre-operative CT and MR scans. The diagnosis of symptomatic sacroiliac disease was confirmed by an injection of local anaesthetic and steroid under image intensifier control.

The short form-36 questionnaire and Majeed’s scoring system were used for pre- and post-operative functional evaluation. Post-operative radiological evaluation was performed using plain radiographs.

Intra-operative blood loss was minimal and there were no post-operative clinical or radiological complications. The mean follow-up was for 17 months (9 to 39). The mean short form-36 scores improved from 37 (23 to 51) to 80 (67 to 92) for physical function and from 53 (34 to 73) to 86 (70 to 98) for general health (p = 0.037). The mean Majeed’s score improved from 37 (18 to 54) pre-operatively to 79 (63 to 96) post-operatively (p = 0.014). There were 13 good to excellent results. The remaining two patients improved in short form-36 from a mean of 29 (26 to 35) to 48 (44 to 52). Their persistent pain was probably due to concurrent lumbar pathology.

We conclude that percutaneous hollow modular anchorage screws are a satisfactory method of achieving sacroiliac fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1248 - 1252
1 Sep 2005
Awad JN Kebaish KM Donigan J Cohen DB Kostuik JP

In order to identify the risk factors and the incidence of post-operative spinal epidural haematoma, we analysed the records of 14 932 patients undergoing spinal surgery between 1984 and 2002. Of these, 32 (0.2%) required re-operation within one week of the initial procedure and had an International Classification of Diseases (ICD)-9 code for haematoma complicating a procedure (998.12). As controls, we selected those who had undergone a procedure of equal complexity by the same surgeon but who had not developed this complication. Risks identified before operation were older than 60 years of age, the use of pre-operative non-steroidal anti-inflammatories and Rh-positive blood type. Those during the procedure were involvement of more than five operative levels, a haemoglobin < 10 g/dL, and blood loss > 1 L, and after operation an international normalised ratio > 2.0 within the first 48 hours. All these were identified as significant (p < 0.03). Well-controlled anticoagulation and the use of drains were not associated with an increased risk of post-operative spinal epidural haematoma.