Malunion is the most common complication of the
distal radius with many modalities of treatment available for such
a problem. The use of bone grafting after an osteotomy is still
recommended by most authors. We hypothesised that bone grafting
is not required; fixing the corrected construct with a volar locked
plate helps maintain the alignment, while metaphyseal defect fills
by itself. Prospectively, we performed the procedure on 30 malunited
dorsally-angulated radii using fixed angle
Fractures of the distal radius are the most common bony injuries in the upper extremity, and many treatment Methods: have been described in the literature. External fixation remains a highly versatile method to treat many fracture types involving the distal radius. The primary indications for external fixation include reduction of unstable extra-articular fractures and most intra-articular fractures. The use of adjuvant pinning or mini open procedures can be used when external fixation inadequately reduces the joint line alone, especially with central depressions and highly comminuted injuries. The ease of use of the implants and successful track record make it an extremely versatile tool for treating complex fractures of the distal radius. Purpose: To compare 2 Methods: of surgical treatment for displaced intra-articular fractures of the distal radius: open reduction and internal fixation with dorsal plating (Pi Plate; Synthes, Paoli, PA) versus external fixation with o without K-wires. Methods: We compare a retrospective study about AO type C intra-articular distal radius fractures. The fist group (40 patients) is treated with open reduction and internal fixation with DVR plate ande the second group (65 pacients) is treated with external fixation and K-wires and mini-open reduction. Objective, subjective, and radiographic outcomes were assessed at 2 weeks, 4 to 6 weeks, 10 to 12 weeks, 6 months, and 1- and 2-year intervals. The minimum follow-up period was 6 months; the average follow-up period was 18 months. The principal outcome analyzed was Jakim store that included pain, grip strength, range of motion, complications, and radiographic parameters. The groups were equal with respect to age, gender and fracture subtype. Results: No significant difference was found in the Jakim store outcome. The
Aims. To synthesise the literature and perform a meta-analysis detailing
the longitudinal recovery in the first two years following a distal
radius fracture (DRF) managed with
Aims. Fixation of scaphoid nonunion with a
Purpose: Management of the unstable or comminuted displaced fractures of the distal radius is difficult. We report our experience treating these fractures with AO
Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54o of flexion and 60o of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and DASH scores between dorsal and
Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54 degrees of flexion and 60 degrees of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and Disabilities of Arm, Shoulder and Hand (DASH) scores between dorsal and
Introduction. The flexor carpi radialis (FCR) approach is widely used for
The ITS
Historically the management of distal radial fracture has been often inadequate. It can be difficult to internally fix complex distal radial fractures with conventional plates. The fracture often collapses with metalwork failure. Literature suggests that malunion may lead to painful wrist with loss of function. In recent years fixed angle locking plate has been advocated for treatment of complex distal radius fracture. Our aim was to assess to assess the effectiveness of the
Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials, including the lack of metal allergies, radiolucency, low artifacts on magnetic resonance imaging scans and the possibility of tailoring mechanical properties. The purpose of this study was to evaluate the clinical results at mean 24-month follow-up using a new plate made of carbon-fiber-reinforced polyetheretherketon (CFR-PEEK) for the treatment of distal radius fractures. We performed a prospective study including all patients who were treated for unstable distal radius fracture with a CFR-PEEK volar fixed angle plate. We included 70 consecutive fractures of AO types B and C that remained displaced after an initial attempt at reduction. The fractures were classified according to the AO classification: 35 fractures were type C1, 13 were type C2, 6 were type C3, 5 were type B1 and 11 were type B2.Background
Materials and methods
Aims. The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a
Aims of study. To assess and compare the functional, radiological and cosmetic results as well as patient satisfaction in patients treated with the IMN Device Vs
Objective. The aim of this retrospective study is to assess the functional and radiological outcome of a multi-planar corrective osteotomy, distraction and locking fixed angle
There is no consensus on the benefit of arthroscopically
assisted reduction of the articular surface combined with fixation
using a
Penetration of the dorsal screw when treating
distal radius fractures with
Purpose of the study: Defective reduction and secondary displacement after osteosynthesis of distal radius fractures can compromise wrist function.
Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius. Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm LCP Volar Column (VC) Distal Radius Plate (8-hole and 9-hole head). Plates were placed onto the distal radii models in a 3D visualization software by a fellowship-trained orthopaedic hand surgeon. The percent contact, volar cortical angle (VCA), border and overlap of the watershed line (WSL) were measured. Both sexes showed an increase in the average VCA measure from medial to lateral columns which was statistically significant. Female VCA ranged from 28 – 36 degrees, and 38 – 45 degrees for males. WSL overlap ranged from 0 – 34.7629% for all specimens without any statistical significance. The average border distance for females was 2.58571 mm, compared to 3.52411 mm for males, with EA plates having a larger border than VC plates. The border distances had statistically significant differences between the plate types, and was approaching significance between sexes. Lastly, a maximum percent contact of 21.966 % was observed in specimen F4 at a 0.3 mm threshold. No statistical significance between plate or sex populations was observed. This study investigated the incoherency between the volar cortical angle of the distal radius, and the pre-contoured angle of
The purpose of this study was to evaluate the
risk of late displacement after the treatment of distal radial fractures with
a locking
The treatment of unstable distal radius fractures remains controversial.